• 제목/요약/키워드: temperature calibration

검색결과 516건 처리시간 0.026초

한강 수계에서의 다차원 시변화 수리.수온 모델 연구 (Multidimensional Hydrodynamic and Water Temperature Modeling of Han River System)

  • 김은정;박석순
    • 한국물환경학회지
    • /
    • 제28권6호
    • /
    • pp.866-881
    • /
    • 2012
  • Han River is a complex water system consisting of many lakes. The water quality of Lake Paldang is significantly affected by incoming flows, which are the South and North branches of the Han River, and the Kyungan Stream. In order to manage the water quality of the Lake Paldang, we should consider the entire water body where the incoming flows are included. The objectives of this study are to develop an integrated river and lake modeling system for Han River system using a multidimensional dynamic model and evaluate the model's performance against field measurement data. The integrated model was calibrated and verified using field measurement data obtained in 2007 and 2008. The model showed satisfactory performance in predicting temporal variations of water level, flow rate and temperature. The Root Mean Square Error (RMSE) for water temperature simulation were $0.88{\sim}2.13^{\circ}C$ (calibration period) and $1.05{\sim}2.00^{\circ}C$ (verification period) respectively. And Nash-Sutcliffe Efficiency (NSE) for water temperature simulation were 1089~0.98 (calibration period) and 0.90~0.98 (verification period). Utilizing the validated model, we analyzed the spatial and temporal distributions of temperature within Han River system. The variations of temperature along the river reaches and vertical thermal profiles for each lakes were effectively simulated with developed model. The suggested modeling system can be effectively used for integrated water quality management of water system consisting of many rivers and lakes.

LPG 충전기용 온도 보정 시스템 개발 (A Temperature Compensating System for LPG Dispenser)

  • 이상훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 G
    • /
    • pp.3162-3164
    • /
    • 1999
  • In this paper, a temperature compensating system(TCS) for LPG dispenser has been developed. A TCS includes a processor(80C196) with an AID converter. I/O port(82C55) and 6-digit vacuum fluorescent display. Based on encoding signals from the gas flow meter, different calibration values from each apparatus and temperature compensating values from the temperature sensor, the TCS controls the LPG dispensing quantity with switching on or off the solenoid valves. The temperature compensation is performed with analog-to-digital conversion of the temperature sensor. The resolution of temperature compensation is nearly $0.5^{\circ}C$ using 10-bit ADC. The field test of the TCS shows the exact temperature compensation.

  • PDF

Cellular CDMA용 배열 안테나 오차 보정 알고리듬 (An Online Calibration Algorithm for Cellular CDMA Antenna Arrays)

  • 석미경;조상우;전주환
    • 한국통신학회논문지
    • /
    • 제29권2C호
    • /
    • pp.306-314
    • /
    • 2004
  • 배열 안테나를 사용하고 있는 CDMA 기반의 이동 통신 기지국은 효율적인 빔 형성을 위해서 배열 안테나 시스템을 이루고 있는 송수신기 모듈의 정확한 성능을 필요로 하며 이를 위해 오차 보정이 반드시 필요하다. 일반적으로 오차 보정은 internal 오차 보정과 external 오차 보정으로 크게 구분 할 수 있다. 특히 internal 오차 보정은 수신기 모듈을 이루고 있는 RF/IF 회로 소자들의 특성이 변하기 때문에 정기적으로 오차 보정이 필요하다고 알려져 있다. 본 논문에서는 비동기 CDMA 시스템에서 안테나 배열 소자들 간의 진폭 이득과 위상 응답에 오차가 생길 때 온라인으로 보정 할 수 있는 알고리듬을 제안한다. 부공간(subspace) 기반의 알고리듬의 성능 평가와 분석 결과를 제시하기 위해 실험으로 측정한 데이터를 이용하였고, simulated annealing이라는 최적화 방법을 사용하여 부공간(subspace) 기반의 알고리듬에서 발생하는 초기값 문제를 해결하고 모의실험을 통해 확인하였다.

실내모형실험을 통한 TDR 함수량계의 현장 함수비 보정 (Water Content Calibration of Time-Domain Reflectometry Probe Using Laboratory Model Test)

  • 신은철;류병현;박정준
    • 한국지반신소재학회논문집
    • /
    • 제12권2호
    • /
    • pp.1-11
    • /
    • 2013
  • 지하매설구조물인 상수도관 주변 지반의 간극수 동결로 상수도관의 변형에 영향을 미칠 수 있다. 이에 최근에는 현장 계측을 통한 포장 하부구조체의 함수비를 주기적으로 측정하기 위해서 미국 Campbell사의 TDR(time domain reflectometry) CS616 함수량계와 독일의 IMKO사 제품의 TRIME FM를 이용한 수동 함수량계 TRIME P3, T3 Probe를 사용하고 있다. 일반적으로 TDR 함수량계와 TRIME 수동 함수량계는 흙의 종류, 입도, 다짐도, 온도 등에 의해 오차가 유발될 수 있기 때문에, 현장의 시료를 사용하여 TDR 함수량계의 실내보정실험을 반드시 수행해야 한다. 즉, TDR함수량계의 매뉴얼에서는 일반적인 흙의 보정방정식을 제안하고 있지만 현장 적용시에는 반드시 보정실험을 수행하도록 권고하고 있다. 본 연구에서는 상수관 등 지하매설구조물의 주변의 다양한 채움재료를 사용하여 실내 보정 실험을 수행하였으며, 이 결과로부터 TDR함수량계인 CS616, TRIME-T3, TRIME-P3의 보정모델식을 제안하였으며, 보정식에 대한 현장검증을 수행하였다.

Microwave Radiometry 원리를 이용한 생체 내부 온도 추정 (Subcutaneous Temperature Estimation By Microwave Radiometry)

  • 김경섭;이정환
    • 대한의용생체공학회:의공학회지
    • /
    • 제27권6호
    • /
    • pp.357-364
    • /
    • 2006
  • Microwave Radiometry is the spectral measurement of eleclromagnetic radiation at frequency bands in the microwave region. One particular application of Microwave Radiometry is for analyzing temperature difffrentials of inside of human body to detect and diagnose pathologic conditions in which the temperature differentials are related with the symptoms of certain diseases. To accomplish this aim, we propose a new calibration method for estimating subcutaneous temperature by Microwave Radiometer and we also suggest a tumor-imitator phantom structure for simulating heat diffusion propagated by tissues around tumors to evaluate the discernment of brighuless temperature difffrentials.

수평원통 관에서 감온액정을 이용한 난류유동의 온도 및 속도장에 관한 실험적 연구 (An Experimental Study on Temperature and Velocity Fields of the Turbulent Flows Horizontal Cylindrical Tube by Using Thermo-sensitive Liquid Crystal)

  • 장태현;도덕희
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제27권7호
    • /
    • pp.921-929
    • /
    • 2003
  • An experimental investigation was performed to study the characteristics of turbulent water flow in a horizontal circular tube by using liquid crystal. To determine some characteristics of the turbulent flow, 2D PIV technique is employed for velocity measurement and liquid crystal is used for heat transfer experiments in water. Temperature visualization was made quantitatively by calibrating the color of the liquid crystal versus temperature using various approaches (TLC technique: Thermochromic Liquid Crystal), and a neural-network algorithm was applied to the color-to-temperature calibration. This study shoud the temperature and time-mean velocity distribution for Re = 2,436, 2,500 and 2,724 along longitudinal sections and the results appear to be physically reasonable.

Simultaneous Temperature and Velocity Fields Measurements near the Boiling Point

  • Doh, Deog-Hee;Hwang, Tae-Gyu;Koo, Bon-Young;Kim, Seok-Ro
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제31권5호
    • /
    • pp.531-542
    • /
    • 2007
  • Simultaneous measurement technique for temperature and velocity fields near a heated solid body has been constructed. The measurement system consists of a 3-late CCD color camera, a color image grabber, a 1ighting system, a host computer and a software for the whole quantification process. Thermo Chromic Liquid Crystals (TCLC) was used as temperature sensors. A neural network was used to get a calibration curve between the temperature and the color change of the TCLC in order to enhance the dynamic range of temperature measurement. The velocity field measurement was attained by the use of the fray-level images taken for the flow field, and by introducing the cross-correlation technique. The temperature and the velocity fields of the forced and the natural convective flows neat the surface of a cartridge heater were measured simultaneously with the constructed measurement system.

TLC와 컬러화상처리를 이용한 Hele-Shaw Cell 내부 대류 온도장 측정 (Temperature field measurement of convective flow in a Hele-Shaw Cell with TLC and color image processing)

  • 윤정환;도덕희;이상준
    • 대한기계학회논문집B
    • /
    • 제20권3호
    • /
    • pp.1114-1122
    • /
    • 1996
  • Variation of temperature field in a Hele-Shaw convection cell was measured by using a HSI true color image processing system and TLC(Thermochromic Liquid Crystal) solution. The relationship between the hue value of TLC color image and real temperature was obtained and this calibration result was used to measure the true temperature. The temperature field in the Hele-Shaw convection cell shows periodic characteristics of 45 sec at Ra = 9.3 * 10$\^$6/. The temperature field measurement technique developed in this study was proved to be a useful and powerful tool for analyzing the unsteady thermal fluid flows.

프로그래머블한 온도 보상 기법의 스마트 센서 시스템 (A Smart Sensor System with a Programmable Temperature Compensation Technique)

  • 김주환;강유리;이우관;김수원
    • 대한전자공학회논문지SD
    • /
    • 제45권11호
    • /
    • pp.63-70
    • /
    • 2008
  • 본 논문에서는 MEMS 압력 센서의 스마트 센서 시스템을 구현하였다. 피에조 압력센서의 온도 드리프트 문제를 해결하기 위해 외부 환경에 맞춰 시스템이 스스로 발생 오차를 제거하는 보상 알고리즘과 이에 의해 제어되는 프로그래머블한 보정 회로를 제안하였다. 시스템은 신호처리부, 보정 회로, 온도 감지부, 그리고 마이크로프로세서 및 통신부가 SOC으로 구현되었으며, RS-232 인터페이스가 시스템의 모니터링 및 제어를 위해 사용되었다. 구현된 IC의 면적은 $4.38{\times}3.78\;mm^2$이며 $0.35{\mu}m$ CMOS 공정으로 제작되었다. $-40^{\circ}C{\sim}150^{\circ}C$ 온도 범위에서 50 KPa급 MEMS 압력센서의 온도 드리프트 보상 오차는 ${\pm}0.48%$로 측정되었다. 구현된 시스템의 전력소모는 30.5mW로 측정되었다.

NaI(T1) 검출기 스펙트럼의 에너지-채널 관계 자동결정 (Automatic Determination of the Energy Pulse-height Relationship in NaI(TI) Spectra)

  • 이모성
    • Journal of Radiation Protection and Research
    • /
    • 제22권3호
    • /
    • pp.143-151
    • /
    • 1997
  • NaI(TI) 검출기의 파고는 용도에 따라 변하기 때문에, 온도 변화는 분광분석기의 에너지 교정에 영향을 미친다. 외부 선원을 사용하여 파고의 온도 의존성을 보상할 수 있으나 이것은 바람직하지 않은 콤프턴 영향을 야기한다. 이 연구에서는 환경중의 감마선 스펙트럼에서 뚜렸한 $^{212}Pb$로부터의 239 keV 피크, $^{214}Pb$로부터의 351 keV 피크, 40K로부터의 1460 keV 피크, $^{208}Tl$으로 부터의 2614 keV 피크를 에너지 교정의 기준 피크로 사용하였다. 이들 피크를 이용하는 방법은 마이크로소프트사의 Visual Basic으로 프로그램화하였다. 이렇게 개발된 프로그램은 신뢰성과 적용성을 검증하기 위해 $-20^{\circ}C$ 부터 $10^{\circ}C$까지 변하는 온도에서 30분 간격으로 측정한 환경 스펙트럼에 적용하였다. 그 결과로써 일상의 기온에서 측정한 $3'{\times}3'$ NaI(Tl) 검출기의 스펙트럼에 대해 이 방식의 에너지 교정은 효과적임이 입증되었다.

  • PDF