• Title/Summary/Keyword: temperature and humidity variation

Search Result 304, Processing Time 0.028 seconds

Analysis of Environment Control Capability Wintering Beehouse in Young Area (용인지역 저온양봉사의 환경조절성능 분석(농업시설))

  • 이석건;김란숙;이현우;이종원
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2000.10a
    • /
    • pp.302-307
    • /
    • 2000
  • The wintering honey bee chambers were constructed and inside environment factors were analyzed to provide high technology for efficient wintering of honeybee colonies. As a result of this study, inside air temperature of yongin chamber under the wide range of outside temperature condition was found to be appropriated for wintering of bee, and inside temperature of beehive was about 2$^{\circ}C$ higher than the air temperature in the chamber. The fan operation schedule did not control the high temperature down properly in the chamber, It was necessary to find a new fan operation schedule to be able to provide the optimum temperature for wintering honey bee colonies. inside humidity variation of Yongin chamber was very much depended on outside humidity.

  • PDF

Control of Environments in Greenhouse Using Programmable Logic Controller (PLC를 이용한 온실의 환경제어)

  • 김동억;조한근;김형준
    • Journal of Biosystems Engineering
    • /
    • v.23 no.6
    • /
    • pp.599-606
    • /
    • 1998
  • This study was carried out to develop the control system with PLC and its operating software and to investigate its control ability of greenhouse environments. Two experimental greenhouses were controlled by PLC and ON/OFF controller, respectively. In greenhouse controlled by PLC, target values of air temperature, relative humidity and $CO_2$ concentration were automatically changed. In warm-water heating, the variation of air temperature was reduced to $\pm$ $0.6^{\circ}C$ by the method of proportional-integration(PI) control with an inverter. In ventilation, the variation of air temperature was reduced, since windows open and close with multistage by mutual relation formula among the target, indoor, and outdoor temperature. Relative humidity at daytime was maintained with range of 35% to 55% by PLC controlled fogger. $CO_2$ concentration was automatically controlled from 300 to 800 $\mu$molㆍ$mol^{-1}$ according to amount of solar radiation. The suppling amount and frequency of nutrient solution were controlled by total integrated solar radiation. Difference in the yield of cucumber in the greenhouse controlled by PLC and by ON/OFF controller was not significant at the 5% level.

  • PDF

On the Prediction and Variation of Air Pollutants Concentration in Relation to the Meteorological Condition in Pusan Area (기상조건에 따른 부산지역 대기오염물질 농도변화와 예측에 관한 연구)

  • 정영진;이동인
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.14 no.3
    • /
    • pp.177-190
    • /
    • 1998
  • The concentrations of air pollutants In large cities such as Pusan area have been increased every year due to the increasing of fuels consumption at factories and by vehicles as well as the gravitation of the population. In addition to the pollution sources, time and spatial variation of air pollutants concentration and meteorological factors have a great influence on the air pollution problem. Especially , its concentration is governed by wind direction, wind speed, precipitation, solar radiation, temperature, humidity and cloud amounts, etc. In this study, we have analyzed various data of meteorological factors using typical patterns of the air pressure to investigate how the concentration of air pollutants is varied with meteorological condition. Using the relationship between meteorological factors (air temperature, relative humidity, wind speed and solar radiation) and the concentration of air pollutants (SO2, O3) , experimental prediction formulas for their concentration were obtained. Therefore, these prediction formulas at each meteorological factor in a pressure pattern may be roughly used to predict the air pollutants concentration and contributed to estimate the variation of its value according to the weather condition in Pusan city.

  • PDF

Analyzing Change of Discomfort Index for Transpiration of Street Tree (도시 가로수의 증산 작용으로 인한 불쾌지수 변화 분석)

  • Yun, Seok-Hwan;Lee, Dong-Kun;Park, Chae-Yeon
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.23 no.5
    • /
    • pp.29-43
    • /
    • 2020
  • Thermal environment of city is getting worse due to severe urban heat island caused by climate change and urbanization. The cooling effect of street tree is regarded as a effective way to ameliorate the urban heat environment. The effect is largely made up of shadow formation and transpiration. This study aims to identify how the transpiration affects the discomfort index by analyzing comprehensive impact of the transpiration on the air temperature and relative humidity. The changes in the amount of transpiration, air temperature, and relative humidity were estimated for Seogyo-dong area which has a lot of floating population in Seoul, at 2 p.m. in dry day in July and August. On average, the transpiration of the street tree decreased the temperature 0.3℃ and increased the relative humidity 2.6% in an hour. As a result of these changes in temperature and humidity, the discomfort index rose mostly(0.036 on average). It was always get rise especially on the day when the discomfort index was above 80(0.05 on average). However, compared with the significant change in temperature and humidity, the variation of the discomfort index itself was very slight(up to 0.107). Therefore, the effect of transpiration by the street trees might not be effective in the planning to improve the thermal environment(especially on the day when the discomfort index is high). It is necessary to select the species of trees and planting location considering the cooling effect of shade formation synthetically.

Improvement of Gas Turbine Performance Using LNG Cold Energy (액화천연가스의 냉열을 이용한 가스터빈의 성능향상)

  • Kim, Tong Seop;Ro, Sung Tack;Lee, Woo Il;Choi, Mansoo;Kauh, Sang Ken
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.5
    • /
    • pp.653-660
    • /
    • 1999
  • This work describes analysis on the effect of inlet air cooling by the cold energy of liquefied natural gas(LNG) on the performance of gas turbines. Gas turbine off-design analysis program to simulate the influence of compressor inlet temperature variation is prepared and an inlet air cooler is modeled. It is shown that the degree of power augmentation is much affected by the humidity of inlet air. If the humidity is low enough, that is the water content of the air does not condense, the temperature drop amounts to $18^{\circ}C$, which corresponds to more than 12% power increase, in case of a $1350^{\circ}C$ class gas turbine with methane as the fuel. Even with 60% humidity, about 8% power increase is possible. It is found that even though the fuel contains as much as 20% ethane in addition to methane, the power improvement does not change considerably. It is observed that if the humidity is not too high, the current system is feasible oven with conceivable air pressure loss at the inlet air cooler.

Variation of Hydro-Meteorological Variables in Korea

  • Nkomozepi, Temba;Chung, Sang-Ok;Kim, Hyun-Ki
    • Current Research on Agriculture and Life Sciences
    • /
    • v.32 no.3
    • /
    • pp.135-143
    • /
    • 2014
  • The variability and temporal trends of the annual and seasonal minimum and maximum temperature, rainfall, relative humidity, wind speed, sunshine hours, and runoff were analyzed for 5 major rivers in Korea from 1960 to 2010. A simple regression and non-parametric methods (Mann-Kendall test and Sen's estimator) were used in this study. The analysis results show that the minimum temperature ($T_{min}$) had a higher increasing trend than the maximum temperature ($T_{max}$), and the average temperature increased by about $0.03^{\circ}C\;yr.^{-1}$. The relative humidity and wind speed decreased by $0.02%\;yr^{-1}$ and $0.01m\;s^{-1}yr^{-1}$, respectively. With the exception of the Han River basin, the regression analysis and Mann-Kendall and Sen results failed to detect trends for the runoff and rainfall over the study period. Rapid land use changes were linked to the increase in the runoff in the Han River basin. The sensitivity of the evapotranspiration and ultimately the runoff to the meteorological variables was in the order of relative humidity > sunshine duration > wind speed > $T_{max}$ > $T_{min}$. Future studies should investigate the interaction of the variables analyzed herein, and their relative contributions to the runoff trends.

Numerical Simulation of the Thermal Environment Inside an Opened Tomb (개방된 고분 내부의 열 환경 수치모사)

  • Youn, Young-Muk;Jun, Hee-Ho;Lee, Kum-Bae
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.1
    • /
    • pp.43-50
    • /
    • 2007
  • In recent years the importance of the preservation of cultural artifacts like ancient tombs has been widely accepted domestically and internationally with increasing value of cultural artifacts. However not much technical attention has been paid for the facilities and systems to preserve these artifacts. As a part of the present study, the temperature and relative humidity inside a selected artifact, Shinkwan-ri tomb, have been monitored for a year round to improve the understanding of the indoor thermal environment. In this study, using the Computational Fluid Dynamics calculated the velocity and temperature distribution and offered basic data which are necessary for the best fitted design of tomb air-conditioning device. Through the result of this study, the generation of temperature variation was identified by natural convection. It enables us to get the possibility of humidity variation

산림토양에서의 Phenanthrene, Pyrene, Benzo(a)pyrene의 휘발 속도: 토양온도와 대기습도의 영향

  • 이신향;김현숙;이동수
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2001.09a
    • /
    • pp.99-102
    • /
    • 2001
  • The soil-to-air fluxes of three PAHs(Phenanthrene, Pyrene, Benzo(a)pyrene) from a laboratory contaminated forest soil were investigated in experimental microcosms. The effects of soil temperature(45$^{\circ}C$, $25^{\circ}C$, 5$^{\circ}C$) and relative humidity(0%, 100%) were investigated according to existence of the humic layer(O layer) over the mineral layer(A layer). Volatilization flux experiments were carried out for a period of 96 hrs. The resulting PAHs volatilization fluxes from the different conditions were quantified and compared. In the mineral layer, highest volatilization flux among the individual PAHs was Phenanthrene >Pyrene> Benzo(a)pyrene on the conditions of 45 $^{\circ}C$, RH=100%. In the humic layer over the mineral layer, maximum volatilization flux was Phenanthrene on the condition of 45$^{\circ}C$, RH=0%. Results from flux experiments showed that volatilization fluxes of PAHs were dependent on soil temperature. Existance of humic layer over the mineral layer delayed transportation to the air of especially heaveir molecular PAHs. But, if humic layer is contained water sufficiently, it is possible that volatilization fluxes are enhanced by water convective flux according to variation of soil temperature and air relative humidity.

  • PDF

Study of Humidity Sensing Properties Related to Metal Content of Aerosol Deposited Ceramic/Metal Composite Films (에어로졸 증착한 세라믹/금속 복합막의 금속 함량에 따른 습도 감지 특성 연구)

  • Kim, Ik-Soo;Koo, Sang-Mo;Park, Chulhwan;Shin, Weon Ho;Lee, Dong-Won;Oh, Jong-Min
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.34 no.5
    • /
    • pp.314-320
    • /
    • 2021
  • Controlling ambient humid condition through high performance humidity sensors has become important for various fields, including industrial process, food storage, and the preservation of historic remains. Although aerosol deposited humidity sensors using ceramic BaTiO3 (BT) material have been widely studied because of their longtime stability, there remain critical disadvantages, such as low sensitivity, low linearity, and slow response/recovery time in case of the sensors fabricated at room temperature. To achieve superior humidity sensing properties even at room temperature condition, BT-Cu composite films utilizing aerosol deposition (AD) process have been proposed based on the percolation theory. The BT-Cu composite films showed gradually improved sensing properties until the Cu concentration reached 15 wt% in the composite film. However, the excessive Cu (above 30 wt%) containing BT-Cu composite films showed a rapid decrease of the sensing properties. The results of observed surface morphology of the AD fabricated composite films, to figure out the metal filler effect, showed correlation between surface topography as well as size and the amount of open pores according to the metal filler content. Overall, it is very important not only dielectric constant of the humidity sensing films but also microstructures, because they affect either the variation range of capacitance by ambient humidity or adsorption/desorption of ambient humidity onto/from the humidity sensing films.

Investigation on Adhesive Properties depending on the Environmental Variation of the Steel Plate Adhesive Strengthening Method by the Epoxy Resin (에폭시 수지 접착 강판보강공법의 환경 변화에 따른 부착 특성 검토)

  • Han, Cheon-Goo;Byun, Hang-Yong;Park, Yong-Kyu
    • Journal of the Korea Institute of Building Construction
    • /
    • v.7 no.3
    • /
    • pp.107-113
    • /
    • 2007
  • This study is to investigate adhesive properties depending on the temperature, humidity, and freeze-thraw of the Steel plate adhesive strengthening method by the epoxy resin. The results are summarized as following. For the temperature variation, the debonding failure appear only after 1 cycle of temperature varoation because the coefficient of thermal expansion of the epoxy resin is comparatively large, and the bonding strength is decreased. The deformation properties and ultrasonic pulse velocity on each materials are similar until 4 cycles on the dry and moisture test. As the freeze-thraw test, the epoxy resin is degraded easily subjected to freeze-thaw cycle, comparatively easy, so the debonding failure may occur in short term because of the freeze-thaw repeatition.p