• Title/Summary/Keyword: temperature and humidity chamber

Search Result 241, Processing Time 0.024 seconds

Development of a curling pad performance test system to support Korea curling team (국가대표 컬링 대표팀 지원을 위한 컬링 패드 성능 시험 시스템 개발)

  • Kim, Taewhan;Lee, Sangcheol;Kil, Sekee
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.10
    • /
    • pp.25-30
    • /
    • 2020
  • In this study, a test system which can test performance of curling pad was developed to support Korea curling team. The developed system consists of a water tank, a mechanical pad driving system that can perform sweeping movement using a curling pad on surface of ice made by the water tank, and temperature sensors monitoring ice and air temperatures. To control the temperature of ice and humidity/temperature of air around the ice, all system are installed in a chamber that can isolate the developed system from external environment. Eight kinds of curling pads were tested using the developed system. Test result showed that each curling pad revealed different rate of ice temperature increasing. The pad with the highest rate of ice temperature rising was found to be the same as the most preferred pad by the athletes. Therefore, it was confirmed that the method of measuring change of ice temperature by the sweeping performed in this study is an effective method to test the performance of the pad.

A Study on Wearing Test of Protective Clothing against a Toxic Substance (유해물질 차단을 위한 방호복의 착용실험에 관한 연구)

  • Chung, Myung-Hee;Park, Soon-Ja;Shin, Jung-Sook;Koshiba, Tomoko;Tamura, Teruko
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.30 no.11 s.158
    • /
    • pp.1626-1635
    • /
    • 2006
  • The purpose of this study was to search for comfortable protective clothing for waste incinerator workers. The experimental protective clothing came in two types: one whose outer side made use of polypropylene film, and the inner side, a non-woven rayon fabric processed with charcoal with a 10% density (CF): and one whose outer side made use of polyolefine and polyamide films, and the inner side, a non-woven polypropylene fabric (NNCF). Experiments were conducted on five healthy adult women whose average age was 21. These experiments were conducted at a climate chamber, in which the temperature and relative humidity were set below $28{\pm}1^{\circ}C\;and\;50{\pm}10%$, respectively. Measured were the rectal temperature, the skin temperature, the sweating rate, the weight loss, the heart rate, the blood pressure, the temperature, and the relative humidity of a microclimate and subjective sensation. These were measured within a period of 60 min, consisting of a 20-min stable period, a 20-min exercise period (walking exercise for 2 miles/hr on a treadmill), and a 20-min recovery period. Through this experiment, the differences between the human body's physiological reactions to CF and NNCF clothing, and the human body's comfort levels when wearing these, were determined.

A Study on the Effect of Cotton, Polyester and Cotton/Polyester Blend Fabrics on Subjective Wear Sensations (면과 폴리에스테르의 혼방비율에 따른 착용감에 관한 연구)

  • Chung Chan Joo;Lee Soon Won
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.12 no.3 s.28
    • /
    • pp.285-294
    • /
    • 1988
  • The purpose of this study is to investigate the effect of cotten, polyester and cotton/polyester blend fabrics on subjective wear sensations and physiological responses at the environmental conditions. Experimental garments were round neckline T-shirts made of $100\%$ cotton, $50/50\%$ cotton/polyester, $35/65\%$ cotton/polyester and $100\%$ polyester, respectively. Four healthy young women wern chosen as subjects for the experiment and the subjects have taken intermittent exercise for 30-min, on bicycle ergometer. Conditions of experimental chamber were as follows Environment I; Temperature $30\pm1^{\circ}C$, Humidity $70\pm3\%$ R.H and Air Velocity 0.25 m/sec Envorpnment II; Temperature $22\pm1^{\circ}C$, Humidity $54\pm3\%$ R.H. and Air Velocity 0.25 m/sec The results are as follows; 1) At Environment I, skin temperatures of chest and back covered with experimental garments were not significantly different, but, at Environment II, $100\%$ polyester garment showed the higher skin temperature. 2) In both conditions, garment made of $50/50\%$ cotton/polyester were felt the best 'tactile sensation' and 'comfort' 3) The significance of subjetive wear sonsations among clothings are larger in Environment I than in Environment II.

  • PDF

Analysis of Temperature and Total Heat of Heated Glass through Experimental Measurement and Three-Dimensional Steady-State Heat Transfer Analysis (실측실험과 3차원 정상상태 열전달 해석을 통한 발열유리의 온도 및 전열량 분석)

  • Lee, Do-Hyung;Yoon, Jong-Ho;Oh, Myeong-Hwan
    • KIEAE Journal
    • /
    • v.15 no.1
    • /
    • pp.111-116
    • /
    • 2015
  • Heat loss from windows and condensation occuring on its surface due to its lower insulation value causes much discomfort to occupants. In this study, Heated glass was used to make a basic study on prevention of condensation on glass surface for its heating functionality through experimental measurement and simulation analysis of total heat flux on the interior and exterior surface of glass. Error between experimental results and three dimensional steady-state heat transfer analysis were caused firstly, beacuse in the experimental chambers, cold chamber and steady temperature and humidity chamber, air temperature setting was not constant but rather ON/OFF control, and secondly, due to error rate in heat flux meter due to heat flux direction even in stable conditions.

Electrical Properties of Outdoor Insulator with the Difference of Contaminated Condition (오손조건에 따른 옥외절연물의 전기적 특성)

  • 최남호;구경완;박강식;한상옥
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.467-470
    • /
    • 2000
  • This paper present the result of the investigation, electric properties of outdoor insulators with the difference of contaminated condition. In general, the humidity and the amount of soluble salts such as NaCl, MgCl$_2$are the most dominant factor. A mini-fog chamber with transparent acryl and the standard contamination solution with kaoline was used. The kaoline was applied with sprayer to get the specific ESDD and NSDD value, then the specimen was dried and installed horizontally. And to measure the leakage current and the ambient condition, such as relative humidity and temperature, a DAS system was developed with LabView. From the result, we could know the influence of contaminated condition. Contaminated area and pattern has a close relationship with the electrical properties of outdoor insulator.

  • PDF

Evaluation of Usability in Extreme Temperature Environments of Safeguards Equipment (안전조치 검증장비의 극한 온도환경 적용성 평가)

  • Heekyun Baek;Jinwon Lee;Jung-Ki Shin
    • Journal of Radiation Industry
    • /
    • v.18 no.1
    • /
    • pp.71-78
    • /
    • 2024
  • For most commercial radiation measurement equipment, manufacturers specify an operating temperature in the range of 0 to +40℃. However, in environments that exceed the quality assurance performance of the safeguards equipment, such as the winter environment in North Korea, the performance of the equipment deteriorates or normal use is impossible. In this study, safeguards equipment measurements were performed by creating an extreme temperature environment using a constant temperature and humidity test chamber. The safeguards equipment used in the evaluation was MIRION's Inspector-2000-based equipment, which evaluated the usability in extreme temperature environments using three types of detection units: NaI(Tl), CZT, and HPGe.

Deformation Analysis and Experimental Verification of DVD Optical Disc Holders (DVD 광 디스크 홀더의 변형 해석 및 실험적 검증)

  • 김진곤;박용국
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.5
    • /
    • pp.164-170
    • /
    • 2003
  • To ensure the reliability of DVDR-P and DVD-ROM, it is imperative to remedy the unrecoverable creep deformation and/or relaxation of the holding force of an optical disc holder. To predict the deformation of an optical disc holder, a deformation analysis of an 80 mm optical disc holder considering the creep characteristics of 3 plastic materials has been conducted. Subsequently, the results by this Finite Element Analysis (FEA) are experimentally verified. A disc holder inserted in a cartridge case is kept in a chamber of $60^{\circ}C$ with 90 % humidity for 24 hours. The arm span and the holding force of the disc holder are measured after being left for another 24 successive hours at a room temperature and under normal humidity. The predicted results by FEA are in good agreement with experimentally measured values.

Leakage Current Properties Analysis of Outdoor Insulator on Climatic.Environmental Factor (기후.환경 인자에 의한 옥외 절연물의 누설전류 특성 분석)

  • Lee, Won-Yeong;Shim, Kyu-Il;Han, Sang-Ok;Park, Gang-Sik
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05c
    • /
    • pp.27-30
    • /
    • 2002
  • In this paper, we were investigated leakage current properties of outdoor insulator on climatic environmental factor. Contamination is one of the most important factor to determine the performance of insulator. Thus, it is very important to exam the contamination degree on the outdoor insulator. There are many limits, such as reliability of data, interval of measurement and similarity of environmental conditions, in conventional method. So, we measured phase and leakage current of outdoor insulator using the temperature & humidity chamber. In this investigation, phase difference was measured to compare the variance of phase difference with the contamination degree and relative humidity.

  • PDF

The Effect of the Formaldehyde Removal of Fore Temperate Ground Cover Plants (4가지 온대성 지피식물의 실내 포름알데이드 제거효과)

  • Ju, Jin-Hee;Bang, Kwang-Ja;Lee, Jin-Hee
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.35 no.2 s.121
    • /
    • pp.49-54
    • /
    • 2007
  • This research was performed to investigate the effect of formaldehyde removal and confirm the utility of plants as indoor environment improvement systems. The plant materials used in this study were Fatsia japonica, Ardisia japonica, Ardisia pusilla and Davallia mariesii. Plants were placed in an airtight chamber under artificial formaldehyde. The initial formaldehyde concentration in the chamber was $500{\pm}30ppb$, and the conditions of $1,500{\sim}2,000lux$ light, $25{\pm}5^{\circ}C$ temperature and $80{\sim}90%$ humidity were maintained. Each chamber was treated as no plant, plant-only and Plant+soil. The total leaf number for Davallia mariesii, Ardisia japonica, Ardisia pusilla, and Fatsia japonica was 40.8, 48.6, 62.3, and 11.8 respectively. The total leaf space n of those plant materials were $2,385cm^2,\;1,252cm^2,\;2,468cm^2\;and\;1,262cm^2$ respectively. The formaldehyde concentration was reduced to $80{\sim}90%$ of the initial concentration in plant-only and Plant+Soil treatment chamber of all species in 12 hours. In the plant-only chamber, Fatsia japonica had removed formaldehyde density by 95% after 12 hours while Ardisia japonica had removed 90%. In the case of Ardisia pusilla, the early removal rate was higher in the plant-only treatment chamber than the Plant+Soil treatment chamber. The formaldehyde removal rate of Davallia mariesii was 98% after 12 hours. In the Plant+Soil treatment chamber, the amount of removal of formaldehyde per time of Davallia mariesii, Ardisia japonica, Ardisia pusilla, and Fatsia japonica was 20.42ppb/hr, 16.28ppb/hr, 2.5.42ppb/hr, 10.28ppb/hr respectively. In the plant-only, That was 22.50ppb/hr, 20.97ppb/hr, 20.83ppb/hr, 20.97ppb/hr respectively.

The Estimation of Harmful Air Pollutant Emission from Landfill Site - A Subject of Sulfide Compounds - (쓰레기매립장에서의 유해대기오염물질 배출특성에 관한 연구 - 황화합물을 대상으로-)

  • 노기환;전의찬
    • Journal of environmental and Sanitary engineering
    • /
    • v.16 no.1
    • /
    • pp.47-52
    • /
    • 2001
  • In this study, we focused on typically problematic sulfide compounds Gas samples were captured at Unjung-ding landfill site in Metropolitan Kwangju with flux chamber and floating chamber, and analyzed for the amount of hydrogen sulfide($H_2S$), dimethyl sulfide $((CH_3)_2S)$ and dimethyl disulfide$((CH_3)_2S_2)$. From the gas pipe, landfill surface and leachate treatment plant, estimated total amount of $H_2S$ emission are 12.6ton/yr, 0.01ton/yr and 1.04ton/yr; estimated total amount of $((CH_3)_2S)$ 30.7ton/yr, 0.08ton/yr and 1.72ton/yr; and estimated total amount of ($((CH_3)_2S_2)$ 2.2tom/yr, 0.02ton/yr and 1.03ton/yr, respectively. Further in-depth study on co-relation between age, packing characteristics, temperature and humidity of landfill site and gas emission characteristics is needed.

  • PDF