• Title/Summary/Keyword: technique of design and construction

Search Result 705, Processing Time 0.026 seconds

GIS Technology for Environmental Gelolgic Mapping (환경 지질도 작성을 위한 GIS 응용연구)

  • 김윤종;유일현;김원영;신은선
    • The Journal of Engineering Geology
    • /
    • v.4 no.3
    • /
    • pp.321-331
    • /
    • 1994
  • Environmental geologic maps were produced on the cheong-Ju area using GIS technique. They are GIS maps on land management and regional land use planning. In the last year, the model of environmental geologic map was established, and the digital database was constructed by environmental and geotechnical data collected form various sources. The special maps for environmental geologic study were also pnoduced ; landslide hazard and risk map, cut & fill map, actual run-off map and engineering geological map. The maps are secondary models (sub-model) in order to create final environmental geologic map. Finally, Environmental Geologic Unit(EGU) was evaluated for regional land use planning and land management by EGIS(Environmental Geologic Inforafion System). This unit is very important in order to assess environmental geologic impact on large construction works and detailed road design etc.

  • PDF

A Study on the improvement for response manual of chemical terror incident using the service design analysis (서비스디자인 접근법을 활용한 화학테러현장 대응매뉴얼의 개선방안 연구)

  • Ham, Seung Hee;Park, Namkwun;Lee, Jun
    • Journal of the Society of Disaster Information
    • /
    • v.14 no.3
    • /
    • pp.325-333
    • /
    • 2018
  • Purpose: There have been terrorist attacks all over the world, causing massive damage. In Korea, there are few cases of terrorist damage, but the lack of the on-site response experience lead to constraints on the opportunity to verify capabilities against terrorism. Therefore, in this study, the chemical terrorism on-site countermeasures is considered as a concept of service, it was possible to draw up improvement alternatives for each element by reviewing at once the interactions between the concerned organizations and citizens in the field and the utilization of the equipment and facilities in the invisible area. Results: It had been evaluated the service process of the counterpart manager from the viewpoint of the victim citizen, who is the beneficiary of the final security service. It has found out the waiting point(W.P) between the victim's civilian incident management, and the element of failure(F.P). Conclusion: In this way, comparing chemical terror incident response manuals belonged to each related organization by fusion of service design approach and scenario technique, It is expected that it will be able to find out more specific problems and to find improvement alternatives.

A Study on the Nano-Plasma Rock Breaking Blasting Method Using Rapidly Expansive Metal Mixture (급팽창 금속혼합물을 이용한 나노프라즈마 바위 파쇄공법에 관한 연구)

  • Kim Sung-Kook;Ahn Myung-Seog;Cho Myung-Chan
    • Explosives and Blasting
    • /
    • v.23 no.3
    • /
    • pp.57-74
    • /
    • 2005
  • In the past, explosives like dynamite was used to blast rock. However, today it is difficult to use explosives in urban blastinglike excavation for subway, building, and housing land. According to Korea Department of Construction and Transportation's proposal for blasting design manual and test blasting, from TYPE I blasting to TYPE IV blasting are recommended when we determine 0.3cm/sec(centisec) as a maximum allowable ground vibration with a distance between $25m\~120m$ from structures. This article was written to introduce one of TYPE I (reck blasting within 25m from structures) blasting method, Nano-Plasma blasting method. When Nano-Plasma blasting method is applied in urban blasting job, ground vibration (15m away from blasting point) is expected 0.1cm/sec, which is only half of a ground vibration when low ground vibration blasting method is applied. By this unique characteristic, Nano-Plasma blasting method is epochal urban blasting technique.

Seismic Performance of Concrete-Filled Steel Piers Part I : Quasi-Static Cyclic Loading Test (강합성교각의 내진성능평가 Part I : 준정적 반복재하실험)

  • 조창빈;서진환;장승필
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.6 no.2
    • /
    • pp.9-19
    • /
    • 2002
  • Steel piers and concrete-filled steel(CFS) piers, in spite of reasonable strength, high ductility, small section, and fast construction, have not been considered as one of alternatives to RC piers even in the highly populated urban area where aseismic safety, limited space and fast construction are indispensably required. This paper, the first of two companion papers for the seismic performance of steel and CFS piers, tests steel and CFS piers under quasi-static cyclic loading to estimate their ductility and strength. Additional details such as rebars and base ribs are added to increase the ductility of a concrete-filled steel pier with minimum additional cost. Also, simplified numerical analyses using nonlinear spring and shell elements are examined for the estimation of the ductility and strength of concrete-filled steel piers and a steel pier. The result shows that concrete-filled steel peirs have higher energy absorption, i.e., ductility and strength than those of steel pier and increasing bonding between in-filled concrete and lower diaphragm, and the improved details of stress concentrated region would be important for the ductility and strength of a pier. Numerical results show that simplified modeling with nonlinear springs and shells has potential to be effective modeling technique to estimate the seismic performance of a concrete-filled steel pier.

A Study on the Quantitative Evaluation of the Load Distribution Factors Considering the Design Conditions of Tunnel Especially for the Ring-cut Excavation Method (터널 설계조건을 고려한 하중분배율의 정량적 산정에 관한 연구 -ring-cut 굴착공법을 중심으로-)

  • 장석부;문현구
    • Geotechnical Engineering
    • /
    • v.14 no.5
    • /
    • pp.5-16
    • /
    • 1998
  • 2-D numerical methods have been applied to analyze the stability of tunnels because of computation efficiency, though the ground around the tunnel under construction shows 3-D reformational behaviour due to the transverse and longitudinal arching effects. Load distribution factors are introduced to the 2-D analysis for the consideration of the effects of the tunnel advance in three dimensions. The load distribution factors influence significantly the ground deformation and the load of primary supports like shotcrete and rockbolts. According to the previous studies for 3-D numerical studies. it was shown that load distribution factors were heavily dependent on the ground deformational properties, tunnel size and the advance length of a tunnel. However, as the quantitative methods evaluating the factors have not been presented yet, constant values have been assigned to the factors for 2-D analysis even if the conditions for tunnel design are different. Accordingly, this paper presents the method to evaluate quantitatively the load distribution factors through the regression analysis of 3-D analysis data on 72 design cases. Also, new modification to the load distribution factors are suggested for the ring-cut excavation method because the conventional 2-D analysis is not able to consider the support effects of the core left on the tunnel face.

  • PDF

Refinement of damage identification capability of neural network techniques in application to a suspension bridge

  • Wang, J.Y.;Ni, Y.Q.
    • Structural Monitoring and Maintenance
    • /
    • v.2 no.1
    • /
    • pp.77-93
    • /
    • 2015
  • The idea of using measured dynamic characteristics for damage detection is attractive because it allows for a global evaluation of the structural health and condition. However, vibration-based damage detection for complex structures such as long-span cable-supported bridges still remains a challenge. As a suspension or cable-stayed bridge involves in general thousands of structural components, the conventional damage detection methods based on model updating and/or parameter identification might result in ill-conditioning and non-uniqueness in the solution of inverse problems. Alternatively, methods that utilize, to the utmost extent, information from forward problems and avoid direct solution to inverse problems would be more suitable for vibration-based damage detection of long-span cable-supported bridges. The auto-associative neural network (ANN) technique and the probabilistic neural network (PNN) technique, that both eschew inverse problems, have been proposed for identifying and locating damage in suspension and cable-stayed bridges. Without the help of a structural model, ANNs with appropriate configuration can be trained using only the measured modal frequencies from healthy structure under varying environmental conditions, and a new set of modal frequency data acquired from an unknown state of the structure is then fed into the trained ANNs for damage presence identification. With the help of a structural model, PNNs can be configured using the relative changes of modal frequencies before and after damage by assuming damage at different locations, and then the measured modal frequencies from the structure can be presented to locate the damage. However, such formulated ANNs and PNNs may still be incompetent to identify damage occurring at the deck members of a cable-supported bridge because of very low modal sensitivity to the damage. The present study endeavors to enhance the damage identification capability of ANNs and PNNs when being applied for identification of damage incurred at deck members. Effort is first made to construct combined modal parameters which are synthesized from measured modal frequencies and modal shape components to train ANNs for damage alarming. With the purpose of improving identification accuracy, effort is then made to configure PNNs for damage localization by adapting the smoothing parameter in the Bayesian classifier to different values for different pattern classes. The performance of the ANNs with their input being modal frequencies and the combined modal parameters respectively and the PNNs with constant and adaptive smoothing parameters respectively is evaluated through simulation studies of identifying damage inflicted on different deck members of the double-deck suspension Tsing Ma Bridge.

Behavior of Geotextile Tube Composite Structure by 2-D Limit Equilibrium and Plane Strain Analysis (2차원 한계평형 및 평면변형해석을 통한 지오텍스타일 튜브 복합구조물의 거동분석)

  • Shin, Eunchul
    • Journal of the Korean GEO-environmental Society
    • /
    • v.7 no.6
    • /
    • pp.13-22
    • /
    • 2006
  • The geotextile have been used in filtration and drainage for over 30 years in many applications of civil and environmental projects. Geotextile tube is compound technology of filtration and drainage property of geotextile. Geotextile have been used for various types of containers, such as small hand-filled sandbags, 3-dimensional fabric forms for concrete paste, large soil and aggregate filled geotextile gabion, prefabricated hydraulically filled containers, and other innovative systems involving containment of soils using geotextile. They are hydraulically filled with dredged materials. It have been applied in coastal protection and scour protection, dewatering method of slurry, and isolation of contaminated material. Recently, geotextile tube technology is no longer alternative construction technique but suitable desired solution. This paper presents the behavior of geotextile tube composite structure by 2-D limit equilibrium and plane strain analysis. 2-D limit equilibrium analysis was performed to evaluate the stability of geotextile tube composite structure for the lateral load and also the plane strain analysis was conducted to determine the design and construction factors. Based on the results of this paper, the three types of geotextile tube composite structure is stable. And the optimum tensile strength of geotextile is 151kN/m and maximum pumping pressure is 22.7kN/m.

  • PDF

Classification of Fire Causes in Warehouses Using the TRIZ Technique and Analysis of Preventive Measures Accordingto 4M (TRIZ기법에 의한 물류창고의 화재원인 및 4M에 따른 예방대책 분석)

  • Han, Sang-Hun;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.6 no.3
    • /
    • pp.401-412
    • /
    • 2020
  • This study analyzed the causes of warehouse fires using a creative problem-solving technique called TRIZ. It identified preventive measures by applying 4M. The results are as follows. First, this study examined the inconsistency among the causes of warehouse fires using TRIZ. Second, it analyzed human factors and fire prevention measures in warehouses such as safety standards for managers, and methods for the promotion of safety consciousness among workers, and for the reinforcement of construction technology for sandwich panel workers. Third, it identified the mechanical and facility factors and fire prevention measures in warehouses such as safety facilities, the expanded installation of safety devices, the adoption and development of fire suppression equipment, and the deployment of methods to improve the fire resistance of sandwich panels. Fourth, it presented working and environmental factors and fire prevention measures in warehouses such as the tightening of safety precautions and the supervision of working methods, and setting fire partitions both in loading places and based on performance-based design. Finally, it proposed managerial factors and fire prevention measures in warehouses such as specific targeting for firefighting with low fire hazards, reviewing the material quality regulations of non-combustible or higher for sandwich panels in the specific target of firefighting that cannot apply fire safety standards, installing sprinklers in cold storage, and mandating the installation of automated facilities with retroactive application regardless of the floor area in the warehouse with a sandwich panel structure.

A Study on the Sale Estimate Model of a Large-Scale Store in Korea (국내 대형점의 매출추정모델 설정 방안 연구)

  • Youn, Myoung-Kil;Kim, Jong-Jin;Park, Chul-Ju;Shim, Kyu-Yeol
    • Journal of Distribution Science
    • /
    • v.11 no.12
    • /
    • pp.5-11
    • /
    • 2013
  • Purpose - The purpose of this study was to construct a turnover estimation model by investigating research by Park et al. (2006) on the market area of domestic distribution. The study investigated distribution by using a new tool for the turnover estimation technique. This study developed and discussed the turnover estimation technique of Park et al. (2006), applying it to a large-scale retailer in "D"city that was suitable for on-the-spot distribution. It constructed the new model in accordance with test procedures keeping to this retail business location, to apply its procedures to a specific situation and improve the turn over estimation process. Further, it investigated the analysis and procedures of existing turnover estimation cases to provide problems and alternatives for turnover estimation for a large-scale retailer in "D"city. Finally, it also discussed problems and scope for further research. Research design, data, and methodology - This study was conducted on the basis of "virtue" studies. In other words, it took into account the special quality of the structure of Korea's trade zones. The researcher sought to verify a sale estimate model for use in a distribution industry's location. The main purpose was to enable the sale estimate model (that is, the individual model's presentation) to be practically used in real situations in Korea by supplementing processes and variables. Results - The sale estimate model is constructed, first, by conducting a data survey of the general trading area. Second, staying within the city's census of company operating areas, the city's total consumption expenditure is derived by applying the large-scale store index. Third, the probability of shopping is investigated. Fourth, the scale of sales is estimated using the process of singularity. The correct details need to be verified for the model construction and the new model will need to be a distinct sale estimate model, with this being a special quality for business conditions. This will need to be a subsequent research task. Conclusions - The study investigated, tested, and supplemented the turnover estimation model of Park et al. (2006) in a market area in South Korea. Supplementation of some procedures and variables could provide a turnover estimation model in South Korea that would be an independent model. The turnover estimation model is applied, first, by undertaking an investigation of the market area. Second, a census of the intercity market area is carried out to estimate the total consumption of the specific city. Consumption is estimated by applying indexes of large-scale retailers. Third, an investigation is undertaken on the probability of shopping. Fourth, the scale of turnover is estimated. Further studies should investigate each department as well as direct and indirect variables. The turnover estimation model should be tested to construct new models depending on the type of region and business. In-depth and careful discussion by researchers is also needed. An upgraded turnover estimation model could be developed for Korea's on-the-spot distribution.

Pullout Resistance of Pressurized Soil-Nailing by Cavity Expansion Theory (공팽창이론에 의한 압력식 쏘일네일링의 인발저항력 산정)

  • Seo, Hyung-Joon;Park, Sung-Won;Jeong, Kyeong-Han;Choi, Hang-Seok;Lee, In-Mo
    • Journal of the Korean Geotechnical Society
    • /
    • v.25 no.7
    • /
    • pp.35-46
    • /
    • 2009
  • Pressure grouting is a common technique in geotechnical engineering to increase the stiffness and strength of the ground mass and to fill boreholes or void space in a tunnel lining and so on. Recently, the pressure grouting has been applied to a soil-nailing system which is widely used to improve slope stability. The soil-nailing design has been empirically performed in most geotechnical applications because the interaction between pressurized grouting paste and the adjacent ground mass is complicated and difficult to analyze. The purpose of this study is to analyze the increase of pullout resistance induced by pressurized grouting with the aid of performing laboratory model tests and field tests. In this paper, two main causes of pullout resistance increases induced by pressurized grouting were verified: the increase of mean normal stress and the increase of coefficient of pullout friction. From laboratory tests, it was found that dilatancy angle could be estimated by modified cavity expansion theory using the measured wall displacements. The radial displacement increases with dilatancy angle decrease and the dilatancy angle increases with injection pressure increase. The measured pullout resistance obtained from field tests is in good agreement with the estimated one from the modified cavity expansion theory.