Assessment guideline for the safe use of metalworking fluids - Focused on water-soluble metalworking fluids (기계가공 공정에서 금속가공유 관리에 대한 평가지침 -수용성 금속가공유를 중심으로-)

  • Park, Dong-Uk
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.20 no.2
    • /
    • pp.131-138
    • /
    • 2010
  • This technical report was developed to suggest the guideline to assess the safe use and handling metalworking fluids (MWFs) in machining operation. The basis of this method developed in this study was based on self assessment procedure recommended by Organization Resources Counselors (ORC) of the United States (US). In addition, various MWF management elements obtained from the review on various articles, reports and author's experience regarding MWF were newly added to the evaluation guideline. A total of four areas were finally selected in order to control exposure to MWF used in machining operations. They are all related to the presence and efficiency of the control measures, exposure assessment, management on tank and sump, and safe treatment of chips and metal fines generated during machining operations. Each area is consisted of several related elements. Several evaluation areas and elements used in this study could be revised, replaced, added and deleted according to the process environment, evaluation objectives and evaluator's (manager) criteria etc. This evaluation guide manual could be used for safe management of MWF in metalworking operation. In addition, industrial hygienists can use this evaluation method for auditing and evaluating the management status on MWF.

A Study on the safety measures for hydrogen cooling system of 500MW class thermal power plant (500MW급 화력발전소 수소냉각시스템의 안전대책)

  • Kim, Soon-Gi;Yuk, Hyun-Dai;Ka, Chool-Hyun
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.385-390
    • /
    • 2005
  • This paper provided a counter measures against the troubles and accidents that are likely to take place in the power plant using hydrogen gas as a coolant for the cooling system of the generator. Because of the extremely wide flammability limits of hydrogen in comparison to the other flammable gases, the safety measures against the hydrogen accidents is very important to ensure the normal operation of electric-power facility. This study's purpose was a presentation of standard model of safety management of hydrogen equipments in the coal firing power plant such as following items: 1) providing the technical prevention manual of the hydrogen explosions and hydrogen fires occurring in the cooling system of power generator; 2) the selection of explosion-proof equipments in terms of the risk level of operating environment; 3) the establishment of regulations and counter measures, such as the incorporation of gas leakage alarm device, for preventing the accidents from arising; 4) the establishment of safety management system to ensure the normal operation of the power plant.

  • PDF

Development of the Power Restoration Training Simulator for Jeju Network

  • Lee, Heung-Jae;Park, Seong-Min;Lee, Kyeong-Seob;Song, In-Jun;Lee, Nam-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.9
    • /
    • pp.18-23
    • /
    • 2006
  • This paper presents an operator training simulator for power system restoration against massive blackout. The system is designed especially focused on the generality and convenient setting up for initial condition of simulation. The former is accomplished by using power flow calculation methodology, and PSS/E data is used to set up the initial state for easy setting. The proposed simulator consists of three major components-a power flow(PF), a data conversion(CONV), and, a GUI module. The PF module calculates power flow, and then checks over-voltages of buses and overloads of lines. The CONV module composes a Y-Bus array and a database at each restoration action. The initial Y-Bus array is composed from PSS/E data. A user friendly GUI module is developed including a graphic editor and a built-in operation manual. The maximum processing time for one step operation is 15 seconds, which is adequate for training purpose.

Automatic Database Lecture Management System (데이터베이스 강의 관리 자동화 시스템)

  • Hur, Tai-Sung
    • Journal of the Korea Society of Computer and Information
    • /
    • v.19 no.12
    • /
    • pp.267-274
    • /
    • 2014
  • Even though computer based college lecture management system was developed long ago and has been used ever since, developing perfect lecture management is not simple. The main objective of this system is to develop appropriate online lecture supportive management program suitable for college lectures. This system [ADLEMS] mainly focuses on the management of college database lectures, exams, and grades. This system supports management and grading of attendance, reports, quizzes, mid-term, and final exams. Exam management categorizes into multiple choice questions, essay questions, short answer questions, and SQL. Especially for SQL, division analysis was applied when developing grading system for more effective grade management. For essay questions and short answer questions, manual [hand] grading method was used. Every student can verify the grading process in person to alleviate the problems occurring during the grading process.

The gene repertoire of Pythium porphyrae (Oomycota) suggests an adapted plant pathogen tackling red algae

  • Badis, Yacine;Han, Jong Won;Klochkova, Tatyana A.;Gachon, Claire M.M.;Kim, Gwang Hoon
    • ALGAE
    • /
    • v.35 no.2
    • /
    • pp.133-144
    • /
    • 2020
  • Pythium porphyrae is responsible for devastating outbreaks in seaweed farms of Pyropia, the most valuable cultivated seaweed worldwide. While the genus Pythium contains many well studied pathogens, the genome of P. porphyrae has yet to be sequenced. Here we report the first available gene repertoire of P. porphyrae and a preliminary analysis of pathogenicity-related genes. Using ab initio detection strategies, similarity based and manual annotation, we found that the P. porphyrae gene repertoire is similar to classical phytopathogenic Pythium species. This includes the absence of expanded RxLR effector family and the detection of classical pathogenicity-related genes like crinklers, glycoside hydrolases, cellulose-binding elicitor lectin-like proteins and elicitins. We additionally compared this dataset to the proteomes of 8 selected Pythium species. While 34% of the predicted proteome appeared specific to P. porphyrae, we could not attribute specific enzymes to the degradation of red algal biomass. Conversely, we detected several cellulases and a cutinase conserved with plant-pathogenic Pythium species. Together with the recent report of P. porphyrae triggering disease symptoms on several plant species in lab-controlled conditions, our findings add weight to the hypothesis that P. porphyrae is a reformed plant pathogen.

A Study on the Application of Runway Friction Measurements (활주로 마찰계수 측정 및 적용에 관한 연구)

  • Noh, Kun-Soo
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.24 no.3
    • /
    • pp.62-68
    • /
    • 2016
  • According to the accident/incident reports of aircraft runway overruns and excursions, it generally shows runway friction reduction and aircraft braking capability deterioration are the basic causes due to adverse weather. Although surface of paved runway gets wet, it also should give good friction capability. If runway surface is worn due to long time usage and friction capability is reduced due to rubber accumulation or weather conditions(snow, rain, ice etc.), airport authorities should rapidly measure friction coefficient and give them to relevant persons through aeronautical information system and support safe takeoff and landing. Operation wise, these information of friction coefficient reduction should be lead to aircraft performance adjustments, but the data from manufacturer(performance manual) are airplane braking coefficient and the data from airport authorities are vehicle measured braking coefficient. But these two data are considered as the same meaning although the definite relationship between them is not clarified yet. So I am trying to search for the technical background of these two data and suggest reasonable method to use them efficiently.

Developed Location Based Service System for Management of Underground Facilities' DB (지하시설물 DB의 유지관리를 위한 LBS 시스템 개발)

  • 이현직;황창섭;박기석;유지호
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2004.11a
    • /
    • pp.325-333
    • /
    • 2004
  • Since 1995, One of the NGIS(National Geographic Information System) projects, the underground utilities project has been finished in 2003. The 19 cities in korea for this project will use underground utilities management system using underground utilities database focusing on water and sewage system. However, special expert, technical and experience problem in computer environment has not been had in working department for water and sewage management and maintenance for each local government. The management and maintenance of underground utilities database by manual method is getting lowered a data quality of underground utilities database because of the data omitting, error in writing and securing of the lasted database. Therefore, in this study, Application test for field workers using a mobile tool and environment analysis of wireless communication in Korea and application test of GPS receiver for mobile tools had been processed and made a mobile working environment. The efficient management and maintenance method for underground utilities database has been developed an off- line method for modification and update of database about general work which has a high working frequency because of the limitation of wireless communication environment Also, the emergency working has been applied for on-line method.

  • PDF

Development of Equipment Operating Condition Diagnosis Model Using the Fuzzy Inference (퍼지추론을 이용한 설비가동상태진단 모델 연구)

  • Jeong, Young-Deuk;Park, Ju-Sik
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.28 no.4
    • /
    • pp.109-115
    • /
    • 2005
  • In the study, Methods for operating measures in equipment security to find out dangerousness timely in the system and to need for the prevention and measures. The method for analyzing and reconstructing the causes of accident of equipment in site, and try to save the information of site in real-time and to analyze the state of equipment to look for the factors of accidents. By this analysis, one plan for efficiency of production, Equipment Fault Diagnosis Management and security is integrating and building module of using the Fuzzy Inference based on fuzzy theory. The case study is applied to the industrial electric motors that are necessarily used to all manufacturing equipment. Using the sensor for temperature is attached to gain the site information in real time and to design the hardware module for signal processing. In software, realize the system supervising and automatically saving to management data base by the algorithm based in fuzzy theory from the existing manual input system

The anti-corrosion study on the corrosion-sensitive areas of unpainted weathering steel bridges with closed box girder(II) (밀폐 박스거더형 무도장 내후성강 교량의 부식취약부에 대한 방식대책 연구(II))

  • Song, Chang-Young;Lee, Eui-Ho;Lee, Jea-Hyun;Park, Hyun-Chul;Choi, Jae-Suk;Noh, Young-Tae
    • Corrosion Science and Technology
    • /
    • v.12 no.4
    • /
    • pp.191-197
    • /
    • 2013
  • This study is the second stage of developing the corrosion control technical manual about unpainted weathering steel bridge with closed box girder structures. This paper contains selection of corrosive sealant to apply into crevice of upper flange, injecting test of sealant at mock-up equipment with various condition, evaluation of experiment result. Through the experiment of injection of sealants into crevice of mock-up equipment, it is proved that the tar sealant injecting corrosion control method is useful to protect corrosion at box girder upper flange corroded by remaning rain water with calcium chloride.

The Development of LED Lighting Controller based on the PAN (PAN 기반의 LED 조명 제어 장치 개발)

  • Ohm, Woo-Yong
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.1
    • /
    • pp.145-152
    • /
    • 2016
  • The usage of LED(Light Emitting Diode) has been rapidly increased and energy efficient management of LED light system is regarded as an important technology to enhance the energy efficiency. In this paper, we design and implementation of LED lighting controller which can control the LED lighting by using the wire and wireless communication technology based on the LAN(Local Area Network) and PAN(Personal Area Network). The implemented system can reduce the cost of LED lighting installing and avoids complicated wiring problem. And it is possible to minimize power consumption through automatic or manual LED control that they wished. In experimental results, the implemented LED lighting controller was satisfactory for all of the desired functions.