• Title/Summary/Keyword: technetium-99m labeling

Search Result 13, Processing Time 0.023 seconds

Migration of $^{99m}Tc$-Hexamethylpropylene Amino Oxime (HMPAO) Labeled Immature and Mature Dendritic Cells in the Mouse (마우스에서 Tc-99m HMPAO 표지 미성숙 및 성숙 수지상세포의 이동에 관한 연구)

  • Li, Ming-Hao;Lee, Je-Jung;Min, Jung-Joon;Heo, Young-Jun;Song, Ho-Chun;Park, Young-Kyu;Park, An-Na;Bom, Hee-Seung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.1
    • /
    • pp.26-33
    • /
    • 2005
  • Purpose: The purpose of this study is to evaluate migration of technetium-99m hexamethylpropylene amine oxime ($^{99m}Tc$-HMPAO) labeled immature and mature dendritic cells (DC) in the mouse. Methods: DC were collected from bone marrow (BM) of tibiae and femurs of mice. Immature and mature DC from BM cells were radiolabeled with $^{99m}Tc$-HMPAO. To evaluate the functional and phenotypic changes of DC from radiolabeling, the allogeneic mixed lymphocyte reaction (MLR) and fluorescence-activated cell sorting (FACS) analysis were performed before and after labeling with $^{99m}Tc$-HMPAO. Migration of intravenously injected DC (iv-DC) was assessed by serial gamma camera images of mice with or without subcutaneous tumor. Percent injected dose per gram (%ID/g) was calculated in lungs, liver, spleen, kidneys, and tumor through dissection of each mice after 24 hours of injection. Results: Labeling efficiency of immature and mature DC were $60.4{\pm}5.4%\;and\;61.8{\pm}6.7%$, respectively. Iv-DC initially appeared in the lungs, then redistributed mainly to liver and spleen. Migration of mature DC to spleen was significantly higher than that of immature DC ($38.3{\pm}4.0%\;vs.\;32.2{\pm}4.1%$ in control group, $40.4{\pm}4.1%\;vs.\;35.9{\pm}3.8%$ in tumor group; p<0.05). Migration to tumor was also significantly higher in mature DC than in immature DC ($2.4{\pm}0.3%\;vs\;1.7{\pm}0.2%$; p=0.034). Conclusion: Assessment of migration pattern of DC in mice was possible using $^{99m}Tc$-HMPAO labeled immature and mature DC. Migration of mature DC to spleen and tumor was higher than that of immature DC when they were i.v. injected.

Evaluation of Biocompatibility of Extracorporeal Circuit - Development of a Quantification Technique using in-vivo Injection of Tc99m Radioactive Platelets - (체외순환도관의 혈액적합성 평가 - 방사선 동위원소(Tc99m) 활성화 혈소판의 생체 내 주입을 이용한 정량분석법의 개발 -)

  • Lee, Sung-Ho;Sun, Kyung;Choi, Jai-Geol;Son, Ho-Sung;Jung, Jae-Seung;Ahn, Sang-Soo;Oh, Hye-Jung;Lee, Whan-Sung;Lee, Hye-Won;Kim, Kwang-Taik;Jeong, Yoon-Seop;Kim, Young-Ha;Kim, Hyoung-Mook
    • Journal of Chest Surgery
    • /
    • v.35 no.3
    • /
    • pp.171-176
    • /
    • 2002
  • Background: Blood-foreign interaction cause activation of coagulation and inflammatory process that may lead to multiorgan dysfunction and determine the surgical outcomes. Of the methods for assessing the biocompatibility, the platelet adhesion study is considered as the most valuable evaluation step in blood-foreign interaction. As the most studies have used in-vitro or ex-vivo conditions, we have developed a technique of quantification for platelet adhesion on the blood contact surface by using in-vivo injection of radioactive platelets. Material and Method: A coupled bypass circuit was designed to connect the proximal and descending thoracic aorta in 6 piglets(20∼25 Kg). One side of the circuit tube was consisted of a heparin coated PVC tube(10mm in ID, n=6, Experimental group), and the other, a non-heparin coated PVC tube(10mm in ID, n=6, Control group). After cannulation, the blood was circulated through the circuit for 2 hours. Platelet concentrate was prepared from homologous pig blood 24 hours before the experiment. The platelet concentrate was incubated with Tc-99m-HMPAO for 30 min and then centrifuged for 10 min. The supernatant was discarded and the radio-labeling efficacy was measured. The radio-labeled platelet concentrate was mixed with the autologous plasma to make the volume 5 ml, and the mixture was injected intravenously into the experimental animal. After 2 hour circulation, 5 pieces of the specimen(10mm in length each) were obtained from each PVC tube. The radioisotopes were counted with a gamma counter(Cobra ll, Packard, USA), and the ratio of radioisotope count was compared between the control and experimental group. Result: The radioisotope count number was 537.3221.1 Ci/min in the control group and 311.1 184.5 Ci/min in the experimental group(p=0.0104). The ratio between the groups was 1 to 0.58 (p=0.004). Conclusion: In vivo quantification using technetium-99m-HMPAO labeled platelets is simple and reproducible in evaluating platelet adhesion on a foreign surface. We suggest this technique to be a useful tool for blood compatibility test.

Radiopharmceutical Factors in the Prepartion of $^{99m}Tc-HMPAO$ Images of the Brain (뇌스캔용 $^{99m}Tc-HM-PAO$의 방사성 동위원소표지에 영향을 미치는 인자에 대한 연구)

  • Yeom, Mi-Kyoung;Kim, Sang-Eun;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.25 no.1
    • /
    • pp.117-121
    • /
    • 1991
  • Technetium-99m-hexamethylpropyleneamine oxime $(^{99m}Tc-HM-PAO)$ is a neutral-lipophilic chelate which is used for scanning cerebral blood flow. The labeling efficiencies of $^{99m}Tc-HM-PAO$ is known to be sensitive to the amount of pertechnetate added and the quality of the pertechnetate. Because of these factors, the manufacture recommends that HM-PAO kits be reconstituted with a maximum of 30 mCi pertechnetate which was eluted <4 hr earlier from a generator which had been eluted < 24 hr previously. So we measured the labelling efficiencies and the decomposition rate constant according to the amount of pertechnetate added, the volume of pertechnette added, and generator in-growth time. We used the 3-system chromatographic methods (paper & ITLC-SG chromatography) which analyzed the labelling efficiencies of the $^{99m}Tc-HM-PAO$. There was no significant difference in labelling efficiencies between variable pertechnetate acitvities added. ($39.9{\pm}4.9\;mCi:\;87.8{\pm}5.1\;(%)$, $60.8{\pm}5.0\;mCi:\;90.7{\pm}2.2\;(%)$, $79.0{\pm}6.0\;mCi:\;86.8{\pm}3.9\;(%)$, $106.6{\pm}11.6\;mCi:\;87.7{\pm}1.2\;(%)$, p>0.05) No significant difference in labelling efficiencies were found between pertechnetate of 4ml and 5ml. (4ml : $89.1{\pm}3.2(%)$, 5ml: $87.3{\pm}4.0(%)$, p>0.05). There was no difference between 1-6 and 10-48 hr of generator in-growth time. (1-6 hr: $87.8{\pm}4.0(%)$, 10-48 hr: $89.6{\pm}1.6(%)$, p>0.05) The mean value of decomposition rate constant was $0.196{\pm}0.097\;(hr^{-1})$, and there were no difference according to the amount of pertecnetate added and the volume of pertecnetate added, ($39.9{\pm}4.9\;mCi:\;0.208{\pm}0.059\;(hr^{-1})$, $60.8{\pm}5.0\;mCi:\;0.191{\pm}0.100\;(hr^{-1})$ $79.0{\pm}6.0\;mCi:\;0.192{\pm}0.118\;(hr^{-1})$, $106.6{\pm}11.6\;mCi:\;0.212{\pm}0.030\;(hr^{-1})$, p>0.05, 4 ml: $0.200{\pm}0.074\;(hr^{-1})$, Sml: $0.193{\pm}0.115\;(hr^{-1})$, p>0.05). In the case of using the first eluate, the labelling efficiency of $^{99m}Tc-HM-PAO$ W3S 82.1%. These data suggest that there were no significant alteration in labelling efficiency of $^{99m}Tc-HM-PAO$ according to the considerable range of pertechnetate activities and volume added, and generator in-growth time. Also, it was shown that one vial of HM-PAO kit supplied the $^{99m}Tc-HM-PAO$ which was used for 3-4 patients.

  • PDF