• Title/Summary/Keyword: target water level

Search Result 240, Processing Time 0.024 seconds

A Establishment of Mud Flat Restoration Plan in Gochang Using Abandoned Embanked Farms (축제식(築堤式) 폐양식장을 활용한 고창 갯벌 복원계획 수립)

  • Choi, Hee-Sun;Kim, Hyo-Chang
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.13 no.2
    • /
    • pp.124-137
    • /
    • 2010
  • This study was started with the objective of restoring abandoned embanked farms, which are recently increasing, to mud flat by putting in least amount of energy in the aspect of environmental restoration. For the direction and establishment of the proposal for the restoration of mud flat using embanked farms, a case of Maipo Wetland in Hongkong was analyzed, and a proposal was prepared considering the condition of mud flat in Gochang. The restoration of mud flat in Gochang is intended to create various wetland ecological spaces as well as to provide opportunities for experience, education, recreation, and tourism. Effort was made to development an environment closest to the local ecological environment considering the shape and topographical condition of existing abandoned farms. For construction of the habitat, a target species was chosen and the plan for selection, planting, and management of species of trees suitable for the target species was established. In addition, the water level will be controlled by water gates to conform to the resting, spawning, breeding, and migration period considering the behavioral pattern of waders, the target species. The research on the restoration of mud flat in Korea is in incipient stage and this study provided an opportunity to review the possibility of restoration of abandoned embanked farms to mud flat. For the success of mud flat restoration from a long-term perspective, development of acclimating design infrastructure, technology improvement for mud flat restoration, and basis of partnership for the maintenance should be prepared in a systematical way.

Analysis of Micropollutants Present in Raw Water Supplied for the Several Drinking Water Treatment Plants in Seoul (서울시 정수장 유입 원수내 미량유해물질의 조사)

  • Oh, Byung-Soo;Kim, Kyoung-Suk;Ju, Seul;Kang, Joon-Wun
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.3
    • /
    • pp.245-250
    • /
    • 2004
  • This study investigated the micropollutants present in raw water supplied for the several drinking water treatment plants in Seoul. The target sample waters were collected from the several sites, such as Jayang (JY), Kuui (KI), Paldang (PD) and Kangbuk (KB) at the Han-River stream. The analytical method used in this study enable us to detect about 300 kinds of chemicals commonly found in surface water at ppt level by GC-ion trap MS. In this study, the consideration on the analytic results focused on the four hazardous organics, such as benzenes, phenols, phthalates and pesticides. The numbers of each detected micropollutant were 1~8 kinds for benzenes, 1~7 kinds for phenols, 5~7 kinds for phthalates and 1~9 kinds for pesticides. For the pesticides, the higher concentration was detected in the water samples collected from PD and KB adjacent to the farming area, and at June and July, which is the busy farming season. The total concentrations of each micropollutants detected at all the sites were significantly lower than those of drinking water regulation in Korea as well as other advanced countries. However, the frequently detected micropollutants requires the steady and precise monitoring for the effective management of drinking water source.

Evaluation of Impaired Waterbody and Multivariate Analysis Using Time Series Load Curve -in Jiseok Stream Watershed- (시계열 부하 곡선을 이용한 수체손상 평가 및 다변량 분석 -지석천 유역을 대상으로-)

  • Park, Jinhwan;Kang, Taewoo;Han, Sungwook;Baek, Seunggwon;Kang, Taegu;Yoo, Jechul;Kim, Youngsuk
    • Journal of Korean Society on Water Environment
    • /
    • v.33 no.6
    • /
    • pp.650-660
    • /
    • 2017
  • In this study, pollutant emission characteristics by water damage period analyzed 11 items (water temperature, pH, DO, EC, BOD, COD, TOC, SS, T-N, T-P and flow) with load duration curve, time series load curve and factor analysis for three years (2014-2016). Load duration curve is applied to judge the level of impaired waterbody and estimate impaired level by pollutants such as BOD and T-P in this study depending on variation of stream flow. Water quality standard exceeded the flow of mid-range and low-range by flow condition evaluation using load duration curve. This watershed was influenced by point source more than non-point source. Cumulative excess rate of BOD and T-P kept water quality standard for all seasons (spring, summer, autumn and winter) except BOD 59% in spring. Water quality changes were influenced by pollutants of basic environmental treatment facilities and agricultural areas during spring and summer. Results of factor analysis were classified commonly first factor (BOD, COD, and TOC) and second factor (flow, water temperature and SS). Therefore, effects of artificial pollutants and maintenance water must be controlled seasonally and reduced relative to water damage caused by point pollution sources with effluent standard strengthened in the target watershed.

Effects of Pretreatment for Controlling Internal Water Transport Direction on Moisture Content Profile and Drying Defects in Large-Cross-Section Red Pine Round Timber during Kiln Drying

  • Bat-Uchral BATJARGAL;Taekyeong LEE;Myungsik CHO;Chang-Jin LEE;Hwanmyeong YEO
    • Journal of the Korean Wood Science and Technology
    • /
    • v.51 no.6
    • /
    • pp.493-508
    • /
    • 2023
  • Round timber materials of 600 mm length, cut from large-cross-section round timber of red pine (Pinus densiflora S. et Z.) of 450 mm width and 4.2 m length, were prepared as the target of kiln drying in this study. After treating the target materials through end sealing (ES), end sealing - kerfing (ES-K), lateral sealing - end sealing - boring (LS-ES-B), or lateral sealing - partial end sealing (LS-PES), the effects of the treatment on the incidence of drying defects were determined. The target materials with exposed lateral surface and sealed cross surface were steamed at the initial temperature of 65℃ above the official pest control temperature of 56℃, followed by kiln drying toward the final temperature of 75℃. The target materials with sealed lateral surfaces, on the other hand, were dried at the initial temperature of 90℃ at almost the maximum temperature of conventional kiln drying, as there is no risk of early check formation caused by surface moisture evaporation. The final temperature was set at approximately 100℃. The drying time, taken for the target materials with initial moisture content of 70%-80% to reach the target moisture content of 19%, varied across treatment conditions. The measured drying time was 1,146 hours (approximately 48 days) for the timber with sealed cross surface and 745 hours (approximately 31 days) for the timber with sealed lateral surface, until the moisture content reached the target level. The formation of surface checks could not be prevented in the control and ES groups, but a definite preventive effect was obtained for the LS-ES-B and LS-PES groups.

An Activation Analysis of Target("used H218O") for 18FDG Synthesis (18FDG 생산용 타겟("사용 후 H218O")의 방사화 분석)

  • Kang, Bo Sun
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.3
    • /
    • pp.213-219
    • /
    • 2013
  • Currently, about 35 cyclotrons have been operating in South Korea. Most of them are mainly used for the synthesis of radiopharmaceuticals such as $^{18}FDG$, which is a cancer tracer for nuclear medicine. Highly enriched $H_2{^{18}}O$ containing up to 98% of $^{18}O/O$ isotope ratio is used as the target for $^{18}F$ production. The price of the highly enriched $H_2{^{18}}O$ ranges 60~70 USD/g, and all of them have been imported from foreign country in spite of the very expensive price. The target (enriched $H_2{^{18}}O$) is non-radioactive before the proton beam irradiation. But, the post-irradiation target (used $H_2{^{18}}O$) must be managed following the National Radiation Safety Regulations, because it turns into radioactive by the radioactivation of the impurities within the target. Recently, nevertheless of the fast increasing amount of used $H_2{^{18}}O$ in accordance with the increasing number of nuclear medicine cases, any activation analysis on the used $H_2{^{18}}O$ have been conducted yet in Korea. In this research, activation analysis have been conducted to confirm the specific radioactivity(Bq/g) of each radioisotopes within the used $H_2{^{18}}O$. The analysis have been done on the 3 of 20g samples collected from the used $H_2{^{18}}O$ storages at different cyclotron centers. Based on the results, it was confirmed that the "used $H_2{^{18}}O$" contains gamma emitters such as $^{56}Co$, $^{57}Co$, $^{58}Co$, and $^{54}Mn$ as well as the considerable amount of beta emitter $^3H$. It was also confirmed that the only one sample contained over exemption level of gamma emitters while the specific activity of tritium was lower than the exemption level in all samples. The specific activity of radioisotopes were measured different levels in the samples depending on the elapsed time after irradiation. Further study on the activation of the "used $H_2{^{18}}O$" is definitely necessary, nevertheless the as-is results of this research must be useful in establishing a rational "used $H_2{^{18}}O$" management protocol.

Buffer Zones for Non-Target Organisms by Aerial Pesticide Application Around Rice Paddy (벼 재배지의 항공 방제시 비표적 생물에 대한 안전거리)

  • Park, Yeon-Ki;Jin, Yeoung-Duck;Kim, Byung-Seok;Park, Kyung-Hun;Lee, Jea-Bong;Shin, Jin-Sup;Bae, Chung-Han;Lee, Kyu-Seung
    • The Korean Journal of Pesticide Science
    • /
    • v.11 no.1
    • /
    • pp.32-37
    • /
    • 2007
  • The study was carried out to establish buffer zone for the protection of the non-target organisms by aerial pesticide application. The two pesticide combination of 3-way tank-mixing of three pesticides for aerial application, ferimzone tricyclazole SC + BPMC EC + validamycin-A SL and hexaconzole EC + isoprothiolane EC+phenthoate EC were selected for the simultaneous control of key pests on paddy rice as blast, sheath blight, brown planthopper and moth. Aquatic organisms including killifish and loach in the paddy field and nearby water reservoirs were not affected by aerial application of the pesticides. However, all the water flea were killed, when they were exposed 10 m from the aerially sprayed site, while the water flea exposed in 30 m away from the site were not affected. Honeybees within 50 m in the wind direction and 20 m in the opposite wind direction showed a mortality of $7{\sim}100%$. Residues concentration of the pesticides in paddy water were not detectable level after six days from aerial application. Drifting distance of aerially sprayed droplet from the target area was within 30 m in the wind direction and 20 m in the opposite direction. Consequently, it was the buffer zones in the aerial pesticides application for the protection of the non-target organisms should be at least 50 m for aquatic organisms and 100 m for honeybees.

In Vivo Effects of Lead on Erythrocytes Following Chronic Exposure through Drinking Water

  • Lee, Moo-Yeol;Shin, Jung-Hun;Han, Hee-Shim;Chung, Jin-Ho
    • Archives of Pharmacal Research
    • /
    • v.29 no.12
    • /
    • pp.1158-1163
    • /
    • 2006
  • More than 95% of lead, a environmental heavy metal, entering into blood accumulates in erythrocytes suggesting erythrocytes as an important target of lead toxicity. Recent studies reported that erythrocytes could contribute to blood coagulation via phosphatidylserine (PS) exposure in erythrocytes. However, in vivo effects of chronic lead exposure especially by drink-ing water on procoagulant activity of erythrocytes have not been studied yet. In the present study, we investigated the effects of chronic exposure of lead by drinking water on erythrocytes in rats. Groups of 40 male rats were provided with drinking water containing various concentrations of lead for 4 weeks and complete blood cell count, procoagulant activities of erythrocytes and platelets were evaluated with basic inspections on body weight and food/water consumption. The administration of lead containing drinking water increased the blood lead level (BLL) in a dose-dependent manner up to $22.39{\pm}2.26\;{\mu}g/dL$. Water consumption was significantly decreased while food consumption or body weight gain was not affected. In contrast to the previous findings with acute lead exposure, chronic lead exposure failed to increase PS exposure in erythrocytes with statistical significance although some trends of enhancement were observed. It implies that a certain adaptation might have happened in body during repeated exposure to lead, resulting in attenuation of PS exposure. With this study, we believe that a valuable information was provided for the study on the toxicological significance and the risk assessment of lead contaminated drinking water.

Efficiency Study of Measurement Method by Flow Duration (유황별 유속측정 방법에 따른 유효성 연구)

  • Ham, Sang In;Lee, Jeong Hwan;Kim, Dae Young;Ha, Don Woo;Kim, Yoon Soo;Jung, Kang-Young;Lee, Yeong Jae;Kim, Gyeong Hyeon;Kim, Young Suk
    • Journal of Korean Society on Water Environment
    • /
    • v.34 no.5
    • /
    • pp.462-469
    • /
    • 2018
  • There are differences in method and cycle of flow rate survey depending on purpose of the operating department. To verify and use results of flow data according to the purpose, flow data of the directly measured and tele monitoring system were compared to verify validity. Flow measurement in the Ministry of Environment is aimed at setting up a standard flow of target water quality for water quality management and securing flow data of low and normal water level seasons for water quality evaluation. In this study, correlation analysis result ($R^2$) of same time zone data by direct measurement and tele monitoring system (TMS) at Seombon D point, a unit watershed of Seomjin river, for six years ('10 ~ '15) according to implementation of Total Daily Maximum Load (TDML) was wading 0.716, boating 0.962 and on bridge 0.943, and effectiveness of measurement method was verified by characteristics of flow duration as a season of dry and low-water; normal and high water are appropriate for wading, boating, and on bridge respectively. Results revealed it is reasonable to use directly measured results using the wading and boating method for low water level and dry seasons, and TMS data for rainy seasons. It can be used important data for future policy decisions.

Development of Automatic Water Level Controlled Smart Filling Machine (수위 연동형 스마트 액체 충진 장치 개발)

  • Lee, Jun-Sik;Lee, Jun-Ho;Roh, Young-Hwa;Park, Jung Kyu
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.3
    • /
    • pp.507-513
    • /
    • 2020
  • Liquid filling machines are frequently used in packaging fields; however, there exists a problem in precisely measuring the quantity of the liquid. In the case where the liquid filling machine is not properly metered, there may be issues, such as the fluid exceeding the capacity or chemicals being exposed outside. In this paper, we propose a smart injection nozzle device that can solve the issues stated above. The proposed smart injection nozzle can raise the nozzle according to the water level to remove bubbles and inject the accurate amount of fluid. In addition, the efficiency of the logistics process is enhanced by the smart QR code. Through experiments using the developed smart injection nozzle device, we have noticed that the accuracy of injection capacity, nozzle position, reaction time and building data exceeded the target value. Therefore, it expected that this machine will give more production and save a lot of manpower for packaging industry.

A Study on Hydro Energy Development of Discharged Cooling Water at the Power Plant (발전소 온배수의 수력에너지 개발에 관한 연구)

  • Kang, K.S.;Lee, D.S.;Kim, J.Y.
    • 유체기계공업학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.813-818
    • /
    • 2005
  • Cooling seawater of thermal power plant which amounts about 5 cms per 100 MWe has hydro energy of about 3,000 kW at the thermal power plant complex, but this useful hydro energy has not been developed. Therefore, the feasibility study on hydro energy development of three power plants located in the southern and western coast of Korea was performed. Three target power plants are Samcheonpo, Boryeong and Hadong thermal power plant. The design head to discharge cooling water by gravity and the head caused by tidal level in the southwestern coastal area, could be used for the production of electric power. The various alternatives were studied and technical feasibility and economical efficiency were clearly proved.

  • PDF