• Title/Summary/Keyword: target water level

Search Result 240, Processing Time 0.035 seconds

Fundamental Characteristics the Concrete According to Mixing Methods and Unit Water Content of Ternary Blended Cement (3성분계 시멘트의 단위수량 및 혼합방식에 따른 콘크리트의 기초특성)

  • Lee, Il-Sun;Hong, Seak-Min;Baek, Dae-Hyun;Kim, ki-hoon;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2009.11a
    • /
    • pp.133-136
    • /
    • 2009
  • This study analyzes the mixing and basic characteristics of concrete according to the unit quantity and mixing method of ternary blended cement and the results of this study can be summarized as follows. In the case of the premixed cement (hereafter referred as POBF) of POBF135, it satisfies the target level of fluidity and air content in which it shows relatively small bleedings even though it represents the latest initial and final setting. Also, although the POBF135 represents small initial strength, it shows an increase in the strength according to the increase in aging. In addition, it shows the lowest temperature in the POBF135. As a result, it can be seen that the POBF135 indicates the most optimal mixing subject to considering the aspect of fluidity, compressive strength, and heat of hydration in general figures.

  • PDF

A 4-week Repeated Oral Dose Toxicity Study of CJ-10882 in Dogs

  • Cha, Shin-Woo;Kim, Jong-Choon;Kim, Dal-Hyun;Chung, Moon-Koo;Junghee Han
    • Toxicological Research
    • /
    • v.18 no.3
    • /
    • pp.241-248
    • /
    • 2002
  • The present study was conducted to investigate the potential subacute toxicity of CJ-10882 by a 4-week repeated oral dose in dogs. The test article was administered once dally by gavage to dogs at dose levels of 0, 2, 10, and 50 mg/kg/day for 4 weeks. During the test period, clinical signs, mortality, body weights, food consumption, ophthalmoscopy, urinalysis, hematology, serum biochemistry, gross finding, organ weight, and histopathology were evaluated. Several clinical sign were observed in treated dogs at 50 mg/kg, including salivation and vomiting. Increase in the serum level of ALT and albumin observed in the female 50 mg/kg group was considered as a toxic effect related to the test article since the histopathological change in Liver was accompanied. There were no treatment-related effects on mortality, food and water consumption, ophthalmoscopy, urinalysis, hematology, serum biochemistry, necropsy findings and organ weights in any treatment group. Based on these results, target organ was not observed and the no-observed-adverse-effect level (NOAEL) was 10 mg/kg/day and the absolute toxic dose was 50 mg/kg for both male and female dogs.

Evaluation of applicability of linkage modeling using PHABSIM and SWAT (PHABSIM과 SWAT을 이용한 연계모델링 적용성 평가)

  • Kim, Yongwon;Byeon, Sangdon;Park, Jinseok;Woo, Soyoung;Kim, Seongjoon
    • Journal of Korea Water Resources Association
    • /
    • v.54 no.10
    • /
    • pp.819-833
    • /
    • 2021
  • This study is to evaluate applicability of linkage modeling using PHABSIM (Physical Habitat Simulation System) and SWAT (Soil and Water Assessment Tool) and to estimate ecological flow for target fishes of Andong downstream (4,565.7 km2). The SWAT was established considering 2 multi purpose dam (ADD, IHD) and 1 streamflow gauging station (GD). The SWAT was calibrated and validated with 9 years (2012 ~ 2020) data of 1 stream (GD) and 2 multi-purpose dam (ADD, IHD). For streamflow and dam inflows (GD, ADD and IHD), R2, NSE and RMSE were 0.52 ~ 0.74, 0.48 ~ 0.71, and 0.92 ~ 2.51 mm/day respectively. As a result of flow duration analysis for 9 years (2012 ~ 2020) using calibrated streamflow, the average Q185 and Q275 were 36.5 m3/sec (-1.4%) and 23.8 m3/sec (0%) respectively compared with the observed flow duration and were applied to flow boundary condition of PHABSIM. The target stream was selected as the 410 m section where GD is located, and stream cross-section and hydraulic factors were constructed based on Nakdong River Basic Plan Report and HEC-RAS. The dominant species of the target stream was Zacco platypus and the sub-dominant species was Puntungia herzi Herzenstein, and the HSI (Habitat Suitability Index) of target species was collected through references research. As the result of PHABSIM water level and velocity simulation, error of Q185 and Q275 were analyzed -0.12 m, +0.00 m and +0.06 m/s, +0.09 m/s respectively. The average WUA (Weighted Usable Area) and ecological flow of Zacco platypus and Puntungia herzi Herzenstein were evaluated 76,817.0 m2/1000m, 20.0 m3/sec and 46,628.6 m2/1000m, 9.0 m3/sec. This results indicated Zacco platypus is more adaptable to target stream than Puntungia herzi Herzenstein.

An Importance and Satisfaction Analysis for Improvement Efficiency Use of Waterfront - A Focus on the Waterfront Analysis for Domestic and Foreign Dragon Boat Festival - (친수공간 이용효율성 개선을 위한 중요도·만족도 분석 - 국내·외 드래곤 보트 페스티벌을 위한 친수공간 사례로 -)

  • An, Byung-chul
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.44 no.4
    • /
    • pp.86-99
    • /
    • 2016
  • This study was for analyzing the external environment and internal space structure and improving the way of use efficiency in waterfront through the Dragon boat festival to utilize waterfront actively. Through from the four target area, Hongkong, Busan, Incheon and Daejeon, this study was for an importance and satisfaction analysis for users about the element effect on the waterfront use efficiency and the contribution to cultural contents revitalization of waterfront by giving basic data. The result is as follows. First, in the importance analysis about 12 items, modern cultural infra around the waterfront was ranked highest, 8.26 and waterfront landscape, square & openspaces, convenience facilities, transport, green area, quality of viewing space, historic resources, pedestrian, suitability of width, wave, depth, water quality, berth & mooring were ranked in descending order. Second, waterfront landscape was interpreted by rather the external environmental impact according to city size than the matter of spatial structure in target area and judged as an important factor effect on site selection for waterfront. In the analysis of waterfront landscape, the reason of the high satisfaction about domestic target area was that riverside parks were recently made considering their waterfront activities. Viewing space was major infra where people could experience the pleasant waterfront and watch dynamic water leisure sports like Dragon boat three dimensionally and was thought to be improved for the use efficiency. Third, tourism resources were very important element that affect the use efficiency of waterfront, so waterfront users react sensitively to modern tourism resources rather than to historic resources. This meant that tourism infrastructure for shopping and leisure of the young affected the use efficiency of waterfront, so Hongkong and Busan were in a better position in terms of using waterfront that was near the tourism infrastructure. Fourth, in the analysis of traffic accessibility, both Hongkong and Busan were high evaluated in terms of excellent traffic accessibility by subway. Daejeon was low rated in terms of the satisfaction of use efficiency, because of the relative lower place awareness compared with transportation infrastructure. In Hongkong, waterfront was connected with downtown and in Busan, housing complex and shopping centers were located in the place for users in an easily accessible on foot, so the satisfaction was high-pitched. Finally, in the importance of water surface width and the analysis of satisfaction, except Incheon, all the three were over 200m in width of water surface and this meant the surface width above certain level was interpreted to interrupt the concentration of enjoying the water leisure sports. In the analysis of surface condition such as water quality, water depth and wave, through a survey, Busan had a problem with water quality and Gapcheon in Daejeon had a problem with optimal water depth by the festival participants.

A Study on the Contamination of Solution with Suction used in Tracheostomy Patients (기관지절개술 환자의 흡인시 사용하는 용액의 오염수준 변화 연구)

  • Lim Yun-Hee;Yu Kwang Soo
    • Journal of Korean Public Health Nursing
    • /
    • v.12 no.2
    • /
    • pp.185-200
    • /
    • 1998
  • It has been contributed to public health that the hospital has multiplied in the aspect of number and has been a large size with development of modern medical science, meanwhile the problem of hospital infection is coming out seriously. Respiratory hospital infection among hospital infections develops, very commonly from patients having taken the operation of intubation or tracheostomy, which results from a big factor that the infection developed from medical appliances used for respiration aids, contamination of solution and infection of medical staff. This study is separated into four steps-the time to use normal saline and distillation water for storaging catheter which are the cause of the infection of solution to store distillation water and catheter, not to say the catheter used when the patient who should get tracheostomy operation takes suction. The purpose of this study is to offer the basic data which are needed to check contamination degree as time goes by and nurse intervention and grope for a new nursing intervention. The target of this study is hospitalized 1D an intensive care unit having 700 sickbeds which is located in IKSAN city and it targeted patients before 7 days passed after an operaion of a tracheostormy. Materials collected were analyzed by SPSS PC+ figures program. The result of this study were as follows ; 1. The gradual contamination levels of the normal saline used In suction are showing that colony increase in proportion to the length of time. 2. while colony increases in normal saline with the lapse of time. distillation water mixed with 5cc of potadine did not show any sign of the formation of colony from its preparation until it was used for 8 hours. 3. Such variables as the period of intubation insertion. the length of hospitalization in I.C.U. the age and the level of contamination of normal saline have no inter-relationship. Therefore. as the length of normal saline used In suction. the contamination level increases with the excelleration of the contamination speed. 4. Regarding the number of suction and the contamination level of the normal saline. We can observe correlation contamination level in the 3 step of suction(mean value:13.4) and the saline which was used for one hours(r=0.702. P=0.00l). four hours(r=0.694. P=0.00l). eight hours(r=0.488. P=0.029). Further we can observe contamination in the 4 step of suction (mean value: 17 .8) well as saline used for eight hours; [for one hours (r=0.64l. P=0.002). four hours (r=0.670. P=0.00l). eight hours (r=0.57 4. P=0.008)]. Thesedays clinics use normal saline by changing it. three times a day. however. the timing of saline change and the current suction methoed should be changed given the one hour used normal saline contamination number 79.850. Regarding the number of suction and the contamination lend of the normal saline.

  • PDF

Effects of the Open Level of the Side Window on the Control of the Temperature and Relative Humidity in the Fog Cooling Greenhouse (포그냉방 온실에서 측창개폐수준이 온습도 제어에 미치는 영향)

  • Kim, Young-Bok;Sung, Hyun-Soo;Yun, Nam-Kyu;Lee, Si-Young;Hwang, Seung-Jae;Kim, Hyeon-Tae;Lee, Jang-Pyung
    • Journal of agriculture & life science
    • /
    • v.45 no.6
    • /
    • pp.265-278
    • /
    • 2011
  • Effects of the open level of the side window were studied to control the temperature and relative humidity in the fog cooling greenhouse. The greenhouse was cooled by air atomizing spray nozzles of the air and water two-fluid process. The control process includes the measuring of environmental variables, setting and coding of the water balance equations and heat balance in greenhouse, calculating of the roof window open and spray water, and operating of the motor and pump. The target temperature and relative humidity were set at $28^{\circ}C$, 75%, respectively. The three modes of the side window open level were 0%, 50% and 100%. The average dry bulb temperatures of the inside air were 28.2, 27.2 and $26.3^{\circ}C$, respectively and their standard deviation was ranged from $0.4^{\circ}C$to $0.8^{\circ}C$. Also the relative humidity of the 0% mode was the best controlled one with the average of 76.3% and the standard deviation of 2.1%.

Sensitivity analysis of flood vulnerability index of levee according to climate change (기후변화에 따른 제방의 홍수취약성지수 민감도 분석)

  • Lee, Hoo Sang;Lee, Jae Joon
    • Journal of Korea Water Resources Association
    • /
    • v.51 no.spc
    • /
    • pp.1161-1169
    • /
    • 2018
  • In this study, a new methodology was proposed to evaluate the flood vulnerability of river levee and to investigate the effect on the levee where the water level changes according to climate change. The stability of levee against seepage was evaluated using SEEP/W model which is two-dimensional groundwater infiltration model. In addition to the infiltration behavior, it is necessary to analyze the vulnerability of the embankment considering the environmental conditions of the river due to climate change. In this study, the levee flood vulnerability index (LFVI) was newly developed by deriving the factors necessary for the analysis of the levee vulnerability. The size of river levee was investigated by selecting the target area. The selected levees were classified into upstream part, midstream part and downstream part at the nearside of Seoul in the Han river, and the safety factor of the levee was analyzed by applying the design flood level of the levee. The safety ratio of the levee was analyzed by applying the design flood level considering the current flood level and the scenario of climate change RCP8.5. The degree of change resulting from climate change was identified for each factor that forms the levee flood vulnerability index. By using the levee flood vulnerability index value utilizing these factors comprehensively, it was finally possible to estimate the vulnerability of levee due to climate change.

Wastewater Reuse in Textile Industry: Case of Bandung, Indonesia (섬유공장폐수 재이용 사례: 인도네시아 반둥을 대상으로)

  • Chung, Youngkun;Lee, Mi-Young;Yang, Shi Chun;Kang, Seoktae
    • Journal of Appropriate Technology
    • /
    • v.5 no.1
    • /
    • pp.18-24
    • /
    • 2019
  • Citarum river in West Java, Indonesia plays strategic roles for Jakarta metropolitan areas. Besides it provides major source of water supply such as domestics and drinking water including Jakarta, it also provides water for hundreds of industries through its cascade reservoirs. However, recently, Citarum river basin has been seriously suffering from water and groundwater pollution as well as the lowering-down of groundwater level due to the extreme use of water resources in dry season by domestic and industrial activities. This project objectives are design and installation of industrial wastewater treatment/recycle facilities to overcome the problem of water pollution and the lowering-down of groundwater level in Bandung. For these, cyclone type dissolved air flotation (DAF), CYFLOAT, was successfully installed as the appropriate technology for the target textile industry with 100 ton/day of capacity. The CYFLOAT system can remove the 96.8% of particulates, which are known as a critical factor to recycle the wastewater, within 40 min of residence time. Furthermore, The CYFLOAT system can reduce the operational cost and land use. The project was carried out in strong partnership with local institute including UNPAR, IBT, and PUSKIM for the sustainability of the technology to textile industry complex in Indonesia.

Polycyclic Aromatic Hydrocarbons in Agricultural Waterways in Gyeonggi and Gangwon Provinces, Korea (경기 및 강원지역 농업용수 중 PAHs의 모니터링 연구)

  • Kim, Leesun;Park, Byung-Jun;Lee, Sung-Eun
    • Korean Journal of Environmental Biology
    • /
    • v.34 no.3
    • /
    • pp.216-221
    • /
    • 2016
  • Level and distribution of fourteen polycyclic aromatic hydrocarbons (PAHs) in the agricultural water samples collected in the waterways located in Gyeonggi and Gangwon, Korea were determined for monitoring and risk assessment. A simplified, fast but effective extraction and clean-up methods combined with gas chromatography tandem mass spectrometry (GC-MS/MS) was employed to measure the concentration of the target compounds. The extraction of the analytes of interest in water sample (10 mL) was performed with acetonitrile (10 mL) and the salt. To purify the target PAHs, the clean-up procedure was employed with 2 mL tubes of dispersive solid phase extraction. The optimized method was validated with recoveries, method detection limit (MDL), accuracy and precision. Good recoveries for each PAHs at 10 and $25{\mu}g\;L^{-1}$ were achieved (60 to 110%, with RSD <20%) with linearity (>0.99). MDL for all the analytes was achieved with $0.2{\mu}g\;L^{-1}$. GC-MS/MS results showed that concentration of phenanthrene in the water samples from Gyeonggi (20 sites) ranged from 0.82 to $2.56{\mu}g\;L^{-1}$ and from Gangwon (15 sites) ranged from 0.83 to $1.62{\mu}g\;L^{-1}$. Other PAHs were not found in the water samples but the continuous monitoring for these areas were required.

A 4-week Repeated Oral Dose Toxicity Study of Plant Sterol Esters in Sprague-Dawley Rats

  • Kim, Jong-Choon;Yang, Byung-Chul;Lim, Kwang-Hyeon;Kang, Boo-Hyon;Kim, Choong-Yong;Kim, Kab-Sik;Chung, Dae-Won;Chung, Moon-Koo
    • Toxicological Research
    • /
    • v.18 no.1
    • /
    • pp.31-41
    • /
    • 2002
  • The present study was conducted to investigate the potential subacute toxicity of plant sterol esters by a 4-week repeated oral dose in Sprague-Dawley rats. The test article was administered once daily by gavage to rats at dose levels of 0, 1000, 3000, and 9000 mg/kg/day for 4 weeks. During the test period, clinical sign, mortality, body weights, food and water consumption, ophthalmoscopy, urinalysis, hematology, serum biochemistry, gross finding, organ weight, and histopathology were evaluated. A reduction in the body weight was observed in females of the 9000 mg/kg group on day 27 after the initiation of treatment, but not in males of the group. There were no treatment-related effects on mortality, clinical sign, food and water consumption, ophthalmoscopy, urinarlysis, hematology, serum biochemistry, necropsy findings, organ weights, and histopathology in any treatment group. Based on these results, it was concluded that the 4-week repeated oral dose of plant sterol esters resulted in suppressed body weight in female rats at a dose level of 9000 mg/kg/day. In the condition of this study, target organ was not observed and the no-observed-adverse-effect level (NOAEL) was considered to be 9000 mg/kg/day for males and 5000 mg/kg/day for females.