• Title/Summary/Keyword: target motion analysis

Search Result 238, Processing Time 0.022 seconds

Change of Lumbar Spine and Hip Joint Flexion Angles During Forward Bending of the Trunk Using Manual Facilitation and a Stick (도수 촉진과 막대를 이용한 몸통의 전방 굴곡 운동에 따른 요추와 고관절 굴곡 각도의 변화)

  • Choung, Sung-Dae;Park, Kyue-Nam;Hong, Ji-A;Cho, Min-Sue;Son, Dong-Hwi;Cynn, Heon-Seock
    • Physical Therapy Korea
    • /
    • v.18 no.1
    • /
    • pp.57-63
    • /
    • 2011
  • The purpose of this study was to identify the effects of manual facilitation and a stick on lumbar and hip joint flexion angles in subject with lumbar flexion syndrome during forward bending from a sitting position. Fifteen subjects with lumbar flexion syndrome were recruited for this study. As a pretest, all subjects performed three repetitions of bending the trunk forward until the tips of their fingers touched the target bar. After this pretest, the subjects practiced the forward bending of the trunk 10 times, using either manual facilitation or a stick. Then, as a posttest, all subjects repeated the pretest procedure. The flexion angles of lumbar spine and hip joint during forward bending in a sitting position were measured using a three-dimensional motion analysis system. A paired t-test was used to determine the statistical differences between pre-test and post-test flexion angles and pre- and post-test flexion angle differences between forward bending with manual facilitation and forward bending with a stick. The level of statistical significance was set at p=.05. The results of the study showed that the angle of the lumbar flexion decreased significantly and the bilateral hip flexion angle increased significantly when performing forward bending with stick and manual facilitation. Furthermore, the angle of lumbar flexion decreased significantly and the angle of bilateral hip flexion increased significantly in forward bending with a stick compared to forward bending with manual facilitation. The findings of this study indicate that both forward bending with manual facilitation and sticks could be used to prevent excessive lumbar flexion and increase hip flexion, and that forward bending with a stick is more effective than forward bending with manual facilitation for inducing lumbar spine and hip joint angle changes.

The Effect of MLC Leaf Motion Constraints on Plan Quality and Delivery Accuracy in VMAT (체적조절호형방사선치료 시 갠트리 회전과 다엽콜리메이터의 이동 속도에 따른 선량분포 평가)

  • Kim, Yon-Lae;Chung, Jin-Beom;Lee, Jeong-woo;Shin, Young-Joo;Kang, Dong-Jin;Jung, Jae-Yong
    • Journal of radiological science and technology
    • /
    • v.42 no.3
    • /
    • pp.217-222
    • /
    • 2019
  • The purpose of this study is to evaluate the dose distribution by gantry rotation and MLC moving speed on treatment planning system(TPS) and linear accelerator. The dose analyzer phantom(Delta 4) was scanned by CT simulator for treatment planning. The planning target volumes(PTVs) of prostate and pancreas was prescribed 6,500 cGy, 5,000 cGy on VMAT(Volumetric Modulated Arc Therapy) by TPS while MLC speed changed. The analyzer phantom was irradiated linear accelerator using by planned parameters. Dose distribution of PTVs were evaluated by the homogeneity index, conformity index, dose volume histogram of organ at risk(rectum, bladder, spinal cord, kidney). And irradiated dose analysis were evaluated dose distribution and conformity by gamma index. The PTV dose of pancreas was 4,993 cGy during 0.1 cm/deg leaf and gantry that was the most closest prescribed dose(5,000 cGy). The dose of spinal cord, left kidney, and right kidney were accessed the lowest during 0.1 cm/deg, 1.5 cm/deg, 0.3 cm/deg. The PTV dose of prostate was 6,466 cGy during 0.1 cm/deg leaf and gantry that was the most closest prescribed dose(6,500 cGy). The dose of bladder and rectum were accessed the lowest during 0.3 cm/deg, 2.0 cm/deg. For gamma index, pancreas and prostate were analyzed the lowest error 100% at 0.8, 1.0 cm/deg and 99.6% at 0.3, 0.5 cm/deg. We should used the optimal leaf speed according to the gantry rotation if the treatment cases are performed VMAT.

Evaluation of the Positional Uncertainty of a Liver Tumor using 4-Dimensional Computed Tomography and Gated Orthogonal Kilovolt Setup Images (사차원전산화단층촬영과 호흡연동 직각 Kilovolt 준비 영상을 이용한 간 종양의 움직임 분석)

  • Ju, Sang-Gyu;Hong, Chae-Seon;Park, Hee-Chul;Ahn, Jong-Ho;Shin, Eun-Hyuk;Shin, Jung-Suk;Kim, Jin-Sung;Han, Young-Yih;Lim, Do-Hoon;Choi, Doo-Ho
    • Radiation Oncology Journal
    • /
    • v.28 no.3
    • /
    • pp.155-165
    • /
    • 2010
  • Purpose: In order to evaluate the positional uncertainty of internal organs during radiation therapy for treatment of liver cancer, we measured differences in inter- and intra-fractional variation of the tumor position and tidal amplitude using 4-dimentional computed radiograph (DCT) images and gated orthogonal setup kilovolt (KV) images taken on every treatment using the on board imaging (OBI) and real time position management (RPM) system. Materials and Methods: Twenty consecutive patients who underwent 3-dimensional (3D) conformal radiation therapy for treatment of liver cancer participated in this study. All patients received a 4DCT simulation with an RT16 scanner and an RPM system. Lipiodol, which was updated near the target volume after transarterial chemoembolization or diaphragm was chosen as a surrogate for the evaluation of the position difference of internal organs. Two reference orthogonal (anterior and lateral) digital reconstructed radiograph (DRR) images were generated using CT image sets of 0% and 50% into the respiratory phases. The maximum tidal amplitude of the surrogate was measured from 3D conformal treatment planning. After setting the patient up with laser markings on the skin, orthogonal gated setup images at 50% into the respiratory phase were acquired at each treatment session with OBI and registered on reference DRR images by setting each beam center. Online inter-fractional variation was determined with the surrogate. After adjusting the patient setup error, orthogonal setup images at 0% and 50% into the respiratory phases were obtained and tidal amplitude of the surrogate was measured. Measured tidal amplitude was compared with data from 4DCT. For evaluation of intra-fractional variation, an orthogonal gated setup image at 50% into the respiratory phase was promptly acquired after treatment and compared with the same image taken just before treatment. In addition, a statistical analysis for the quantitative evaluation was performed. Results: Medians of inter-fractional variation for twenty patients were 0.00 cm (range, -0.50 to 0.90 cm), 0.00 cm (range, -2.40 to 1.60 cm), and 0.00 cm (range, -1.10 to 0.50 cm) in the X (transaxial), Y (superior-inferior), and Z (anterior-posterior) directions, respectively. Significant inter-fractional variations over 0.5 cm were observed in four patients. Min addition, the median tidal amplitude differences between 4DCTs and the gated orthogonal setup images were -0.05 cm (range, -0.83 to 0.60 cm), -0.15 cm (range, -2.58 to 1.18 cm), and -0.02 cm (range, -1.37 to 0.59 cm) in the X, Y, and Z directions, respectively. Large differences of over 1 cm were detected in 3 patients in the Y direction, while differences of more than 0.5 but less than 1 cm were observed in 5 patients in Y and Z directions. Median intra-fractional variation was 0.00 cm (range, -0.30 to 0.40 cm), -0.03 cm (range, -1.14 to 0.50 cm), 0.05 cm (range, -0.30 to 0.50 cm) in the X, Y, and Z directions, respectively. Significant intra-fractional variation of over 1 cm was observed in 2 patients in Y direction. Conclusion: Gated setup images provided a clear image quality for the detection of organ motion without a motion artifact. Significant intra- and inter-fractional variation and tidal amplitude differences between 4DCT and gated setup images were detected in some patients during the radiation treatment period, and therefore, should be considered when setting up the target margin. Monitoring of positional uncertainty and its adaptive feedback system can enhance the accuracy of treatments.

Trend and future prospect on the development of technology for electronic security system (기계경비시스템의 기술 변화추세와 개발전망)

  • Chung, Tae-Hwang;So, Sung-Young
    • Korean Security Journal
    • /
    • no.19
    • /
    • pp.225-244
    • /
    • 2009
  • Electronic security system is composed mainly of electronic-information-communication device, so system technology, configuration and management of the electronic security system could be affected by the change of information-communication environment. This study is to propose the future prospect on the development of technique for electronic security system through the analysis of the trend and the actual condition on the development of technique. This study is based on literature study and interview with user and provider of electronic security system, also survey was carried out by system provider and members of security integration company to come up with more practical result. Hybrid DVR technology that has multi-function such as motion detection, target tracking and image identification is expected to be developed. And 'Embedded IP camera' technology that internet server and image identification software are built in. Those technologies could change the configuration and management of CCTV system. Fingerprint identification technology and face identification technology are continually developed to get more reliability, but continual development of surveillance and three-dimension identification technology for more efficient face identification system is needed. As radio identification and tracking function of RFID is appreciated as very useful for access control system, hardware and software of RFID technology is expected to be developed, but government's support for market revitalization is necessary. Behavior pattern identification sensor technology is expected to be developed and could replace passive infrared sensor that cause system error, giving security guard firm confidence for response. The principle of behavior pattern identification is similar to image identification, so those two technology could be integrated with tracking technology and radio identification technology of RFID for total monitoring system. For more efficient electronic security system, middle-ware's role is very important to integrate the technology of electronic security system, this could make possible of installing the integrated security system.

  • PDF

An Analytical Study on the Seismic Behavior and Safety of Vertical Hydrogen Storage Vessels Under the Earthquakes (지진 시 수직형 수소 저장용기의 거동 특성 분석 및 안전성에 관한 해석적 연구)

  • Sang-Moon Lee;Young-Jun Bae;Woo-Young Jung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.6
    • /
    • pp.152-161
    • /
    • 2023
  • In general, large-capacity hydrogen storage vessels, typically in the form of vertical cylindrical vessels, are constructed using steel materials. These vessels are anchored to foundation slabs that are specially designed to suit the environmental conditions. This anchoring method involves pre-installed anchors on top of the concrete foundation slab. However, it's important to note that such a design can result in concentrated stresses at the anchoring points when external forces, such as seismic events, are at play. This may lead to potential structural damage due to anchor and concrete damage. For this reason, in this study, it selected an vertical hydrogen storage vessel based on site observations and created a 3D finite element model. Artificial seismic motions made following the procedures specified in ICC-ES AC 156, as well as domestic recorded earthquakes with a magnitude greater than 5.0, were applied to analyze the structural behavior and performance of the target structures. Conducting experiments on a structure built to actual scale would be ideal, but due to practical constraints, it proved challenging to execute. Therefore, it opted for an analytical approach to assess the safety of the target structure. Regarding the structural response characteristics, the acceleration induced by seismic motion was observed to amplify by approximately ten times compared to the input seismic motions. Additionally, there was a tendency for a decrease in amplification as the response acceleration was transmitted to the point where the centre of gravity is located. For the vulnerable components, specifically the sub-system (support columns and anchorages), the stress levels were found to satisfy the allowable stress criteria. However, the concrete's tensile strength exhibited only about a 5% margin of safety compared to the allowable stress. This indicates the need for mitigation strategies in addressing these concerns. Based on the research findings presented in this paper, it is anticipated that predictable load information for the design of storage vessels required for future shaking table tests will be provided.

Development of Empirical Fragility Function for High-speed Railway System Using 2004 Niigata Earthquake Case History (2004 니가타 지진 사례 분석을 통한 고속철도 시스템의 지진 취약도 곡선 개발)

  • Yang, Seunghoon;Kwak, Dongyoup
    • Journal of the Korean Geotechnical Society
    • /
    • v.35 no.11
    • /
    • pp.111-119
    • /
    • 2019
  • The high-speed railway system is mainly composed of tunnel, bridge, and viaduct to meet the straightness needed for keeping the high speed up to 400 km/s. Seismic fragility for the high-speed railway infrastructure can be assessed as two ways: one way is studying each element of infrastructure analytically or numerically, but it requires lots of research efforts due to wide range of railway system. On the other hand, empirical method can be used to access the fragility of an entire system efficiently, which requires case history data. In this study, we collect the 2004 MW 6.6 Niigata earthquake case history data to develop empirical seismic fragility function for a railway system. Five types of intensity measures (IMs) and damage levels are assigned to all segments of target system for which the unit length is 200 m. From statistical analysis, probability of exceedance for a certain damage level (DL) is calculated as a function of IM. For those probability data points, log-normal CDF is fitted using MLE method, which forms fragility function for each damage level of exceedance. Evaluating fragility functions calculated, we observe that T=3.0 spectral acceleration (SAT3.0) is superior to other IMs, which has lower standard deviation of log-normal CDF and low error of the fit. This indicates that long-period ground motion has more impacts on railway infrastructure system such as tunnel and bridge. It is observed that when SAT3.0 = 0.1 g, P(DL>1) = 2%, and SAT3.0 = 0.2 g, P(DL>1) = 23.9%.

Analysis of Binocular Abnormality by Eyeball Motion in Ametropia (비정시의 안구운동에 의한 양안시 이상 분석)

  • Seong, Jeong-Sub
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.3
    • /
    • pp.205-213
    • /
    • 2005
  • To evaluate the reliability of binocular vision measurements by phorometry. 90 students volunteered to participate in this study. 25 subjects were males, and 65 were females, they ranged in ages from 21 to 30 years. All subjects had normal ocular and systematic health, and all of them had at least 1.0 visual acuity with their best correction. At negative relative convergence(NRC) measurement in distance, the percentage of subjects is included in expected value(blur point/break point/recovery point) was 78%/61%/67%, divergence excess(DE) was 9%/31%/33%, and divergence insufficience(DI) was 13%/8%/9%, respectively. And positive relative convergence(PRC) measurement, includes expected value was 20%/46%/39%, convergence excess(CE) was 22%/14%/16%, and convergence insufficience(CI) was 35%/40%/45%. AC/A ratios of 42 subjects were normal. 38 were low, and the rest of them high. A low AC/A ratio is usually the result of a small vergence response in relation to accommodation. Negative relative convergence(NRC) at near, includes expected value was 26%/29%/44%, divergence excess(DE) was 61%/33%/24%, and divergence insufficience(DI) was 3%/38%/32%. And PRC at near, includes expected value was 33%/40%/31%, convergence excess(CE) was 61%/23%/42%, and convergence insufficience(CI) was 6%/37%/27%. For the near point of convergence(NPC) test, 58% of their subjects had a break of ${\leq}8cm$ with the accommodative target. In case of NRA(PRA) measurement, the expected value was 41%(33%). Accommodative insufficiency (AI) was 33%(43%), and accommodative excess(AE) was 26%(24%), respectively. AE was related to respectively low values of NRA. AI and CE are associated with high value of NRA, and the dysfunction of convergence excess combined with AE was related to a normal-high values of NRA. PRA in AI was related to a low value, wheres the dysfunction are associated with high values of PRA.

  • PDF

Objective Analysis of the Set-up Error and Tumor Movement in Lung Cancer Patients using Electronic Portal Imaging Device (폐암 환자에서 Electronic Portal Imaging Device를 이용한 자세 오차 및 종양 이동 거리의 객관적 측정)

  • Kim, Woo-Cheol;Chung, Eun-Ji;Lee, Chang-Geol;Chu, Sung-Sil;Kim, Gwi-Eon
    • Radiation Oncology Journal
    • /
    • v.14 no.1
    • /
    • pp.69-76
    • /
    • 1996
  • Purpose : The aim of this study is to investigate the random and systematic errors and tumor movement using electronic portal imaging device in lung cancer patients for the adequate margin in the treatment planning of 3-dimensional conformal therapy. Material and Methods : The electronic portal imaging device is matrix ion chamber type(Portal Vision, Varian). Ten patients of lung cancer treated with chest irradiation were selected for this study. Patients were treated in the supine position without immobilization device. All treatments were delivered by an 10 MV linear accelerator that had the portal imaging system mounted to its ganrty. AP or PA field Portal images were only analyzed. Radiation therapy field included the tumor, mediastinum and supraclavicular lymph nodes. A total of 103 portal images were analyzed for set-up deviation and 10 multiple images were analyzed for tumor movement because of respiration and cardiac motion. Result : The average values of setup displacements in the x, y direction was 1.41 mm, 1 78 mm, respectively. The standard deviation of systematic component was 4.63 mm, 4.11 mm along the x, y axis, respectively while the random component was 4.17 mm in the x direction and 3.31 mm in the y direction. The average displacement from respiratory movement was 12.2 mm with a standard deviation of 4.03 mm. Conclusion : The overall set-up displacement includes both random and systematic component and respiratory movement. About 10 mm, 25 mm margins along x, y axis which considered the set-up displacement and tumor movement were required for initial 3-dimensional conformal treatment planning in the lung cancer patients and portal images should be made and analyzed during first week of treatment, individually.

  • PDF