• Title/Summary/Keyword: tap water

Search Result 888, Processing Time 0.024 seconds

Hydration-Setting Property of Slaked Lime and Artificial Zeolite Synthesized with Top Water Sludge (정수슬러지로 합성한 인공제올라이트와 소석회의 수화응결특성)

  • La, Jung-Min;Choi, Duk-Jin;Kim, Min-Gil;Kim, Jin-Man
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.5 no.4
    • /
    • pp.122-128
    • /
    • 2010
  • On the international provision on prohibition of ocean dumping of waste, tap water sludge has been buried or recycled on th low value added product as landfill. Due to the tap water sludge having high inorganic content, differing from the sewage sludge, it is possible to use as a usable resource by suitable process. We have studied on hydro thermal processing of tap water sludge with phosphoric acid and finally synthesize a artificial zeolite having a deodorization property. To use it as a building material, it has to be solidification. This study is on the properties of artificial zeolite synthsized and solidification properties by various types of solidifier. It is showed that the slaked lime is the best on setting property and its optimum content is 30-60 weight proportion. Solid by solidified by slaked lime has low strength and excellent deodorization performance, so it is possible to use as a functional pannel as gypsum board.

  • PDF

Removal of Trihalomethanes from Tap Water using Activated Carbon Fiber (활성탄소섬유를 사용한 수돗물 내 트리할로메탄의 제거)

  • Yoo, Hwa In;Ryu, Seung Kon
    • Korean Chemical Engineering Research
    • /
    • v.50 no.1
    • /
    • pp.83-87
    • /
    • 2012
  • Activated carbon fiber (ACF) was used to remove four kinds of trihalomethanes(THMs) from tap water which were remained as by-products during the chlorination of water. Adsorption capacity was investigated as a function of THMs concentration and solution temperature, and adsorption mechanism was studied in relating to the surface characteristics of ACF. All the four kinds of THMs were rapidly adsorbed on the surface of ACF by physical adsorption due to the enormous surface micropores and chemical adsorption due to the hydrogen bonds, showing a Langmuir type adsorption isotherm. Langmuir type is especially profitable for the adsorption of low level adsorptives. ACF was very effective for the removal of THMs from tap water because the THMs concentration is below $30{\mu}g/L$ in tap water. The adsorption amount of THMs on ACF increased in order of the number of brom atom; chloroform, bromodichloromethane, dibromochloromethane, and bromoform. The adsorption capacity increased as increasing the number of brom atom due to the decrease of polarity in solution. The adsorption capacity of THMs on ACF can be enhanced by proper surface treatment of ACF.

Distribution and Risk Assessment of Bisphenol-A in Tap Water from Rehabilitated Indoor Water Service Pipe (갱생 옥내급수관 수돗물에서 비스페놀-A 분포 및 위해성 평가)

  • Jeong, Gwanjo;Son, Boyoung;Lee, Inja;Ahn, Chihwa;Kim, Junil;Moon, Boram;Lee, Suwon;Ahn, Jaechan;Kim, Bogsoon;Chung, Deukmo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.7
    • /
    • pp.371-376
    • /
    • 2016
  • In this study, the survey of bisphenol-A in indoor water service pipes rehabilitated with epoxy resin was conducted and the risk assessment was done to investigate the effect on the human health to drink tap water. Bisphenol-A in raw water was detected in a range of 50~118 ng/L in all samples, where the limit of quantification was 10 ng/L. This is caused by inflow of the sewage effluent or the tributaries of the surrounding area containing bisphenol-A. Bisphenol-A was not detected in finished water after the advanced water treatment process. It was achieved by its removal from the processes of flocculation-precipitation and oxidation of ozone and chlorine and by being changed to other by-product materials. For the indoor water service pipe, bisphenol-A was not detected in all cases which was not coated with epoxy resin. However, when epoxy resin is lined within the indoor water service pipe, bisphenol-A was identified at maximum level of 521 ng/L and was detected above the limit of quantitation at 68 percentages of all samples. The Hazard Quotient (HQ) at the maximum level (521 ng/L) of the detected bisphenol-A is 0.004, which is less than the reference value of 0.1 for the tap water intake. Therefore, it is considered that the detected levels of bisphenol-A in this study would be safe to drink tap water.

Analyses of Fouling Mechanism using Visualization Techniques in a Lab-scale Plate-Type Heat Exchanging System (실험실용 판형 열교환 시스템에서 가시화를 이용한 파울링 기구 해석)

  • 성순경;서상호;노형운
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.4
    • /
    • pp.349-354
    • /
    • 2004
  • Scale is formed when hard water is heated or cooled in heat transfer equipments such as heat exchangers, condensers, evaporators, cooling towers, boilers, and pipe walls. When the scale deposits in a heat exchanger surface, it is conventionally called fouling. The objective of the present study is to analyze the process of the fouling formation in a heat exchanger according to different types of water using visualization techniques. In order to experimentally investigate the formation of the fouling, this study built a lab-scaled heat exchanging system. Using the visualization techniques of Scanning Electron Microscopy (SEM) and X-Ray diffraction method, the three dimensional configurations of the fouling formation could be successfully obtained. Based on the experimental results, it was found that the configurations of the fouling formation were different when using tap water compared to river water.

Physico-chemical and Microbiological Analysis of Tap Water in the Apartment in Taegu City (대규모 음용수 저장시설의 수질평가)

  • Kim, Seck-Bhum;Kang, Pock-Soo;Chung, Jong-Hak
    • Journal of Yeungnam Medical Science
    • /
    • v.5 no.1
    • /
    • pp.69-75
    • /
    • 1988
  • The drinking water in the apartment is stored in reservior tank and thereafter supplied each household. In case the drinking water is stored too long or insanitary, tap water might change in quality. This study was carried out to evaluate the physico-chemical and microbiological conditions of 36 samples of tap water of apartments compared to 18 samples of tap water of independence houses in Taegu City from May to October, 1987. Main findings are summarized as follows : PH values were within normal range in all samples. Samples less than 0.2ppm in residual chlorine accounted for 16.7% in the appartment and 5.6% in the independence house. Nitrite nitrogen was detected 2.8% of apartment samples only. Among the total of 54 samples, 11.1% of the apartment and independence samples were over the normal value in standard plate count. Samples more than 1.8 of most probable number(MPN) accounted for 27.8% in the apartment and 33.3% in the independence house. In result of test for residual chlorine, nitrite nitrogen, standard plate count, and MPN, the proportion of the samples revealed inappropriated in respect of drinking water standards. In case of all sorts of tests was 2.7% in apartment and nothing in independence houses, in case of 3 sorts of tests was 2.7% in apartment and 5.6% in independence houses, in case of 2 sorts of tests was 8.3% in apartment and 5.6% in independence houses, and in case of only 1 test was 25.0% in apartment and 22.2% in independence houses. Correlation between residual chlorine and standard plate count, and between standard plate count and MPN were observed. It was found that the more years since construction of apartment were, the worse tap water was in quality.

  • PDF

Early Development of Loach Oocytes Activated by Parthenogenetic Agents (미꾸라지 난자의 활성화에 의한 처녀발생 유기)

  • 이재현;최석용;주와종;박홍양;이상호
    • Korean Journal of Animal Reproduction
    • /
    • v.18 no.3
    • /
    • pp.183-189
    • /
    • 1994
  • We examined early development in loach(Misgurnus mizolepis) embryos with parthenogenetic agents well-known in mammals. Female loach was superovulated with an intraperitoneal injection of 15 IU human chorionic gonadotrophin (hCG) per gram body weight. After 13 h of hCG injection, the oocytes were obtained from the abdomen. The oocytes were activated with 10% ethanol in tap water or fish Ringer's solution for 5, 10 and 15 minutes(eTW5, 10, 15 and eFRS5, 10, 15), respectively. The activation rates were 29% and 10% in eFRS10 and eFRS15, 5% and 6% in eTW10 and eTW15 by judging the cleaved blastomeres. Whereas, no parthenogenetic embryo was produced by tap water or fish Ringer's solution alone. The activation rate with the fish Ringer's solution was higher than that of tap water. No embryonic development was observed by calcium ionophore, A23187, at concentrations of 10, 20, 40 and 100$\mu$M when treated for 1, 2.5 and 5 minutes, respectively. The activation agents did not cause early development as in mammalian eggs. Therefore, the results suggest that fresh water fish may have a different egg activation pathway from that of mammals.

  • PDF

Improvement of Corrosion Resistance for Copper Tube by Electrochemical Passivation (전기화학적 부동태화에 의한 동관의 내식성 개선 연구)

  • Min, Sung-Ki;Kim, Kyung-Tae;Hwang, Woon-Suk
    • Corrosion Science and Technology
    • /
    • v.10 no.4
    • /
    • pp.125-130
    • /
    • 2011
  • This study was performed to improve the corrosion resistance and the stability of passive film on copper tube by potentiostatic polarization method in synthetic tap water. Formation of passive film was carried out by anodic potentiostatic polarization at various passivation potentials and passivation times in 0.1 M NaOH solution. Stability of passive film and corrosion resistance was evaluated by self-activation time, ${\tau}_0$ from passive state to active state on open-circuit state in 0.1 M NaOH solution. Addition of polyphosphate in NaOH solution prolonged the self-activation time and improved the corrosion resistance, and the addition of 5 ppm polyphosphate was most effective. It was also observed that better corrosion resistance was obtained by potentiostatic polarization at 1.0 V (vs. SCE) than at any other passivation potentials. Passivated copper tube showed perfect corrosion resistance for the immersion test in synthetic tap water showing that the anodic potentiostatic polarization treatment in 0.1 M NaOH with 5 ppm polyphosphate solution would be effective in improving the corrosion resistance and preventing the blue water problem.

Part-Per-Trillion Level Determination of Alkylphenols, Chlorophenols and Bisphenol A using GC/MS-SIM in Tap Water Samples (GC/MS-SIM 방법에 의한 수돗물 중 알킬페놀, 플로로페놀과 비스페놀 A의 ppt 정량)

  • Kim, Hyub
    • Environmental Analysis Health and Toxicology
    • /
    • v.18 no.3
    • /
    • pp.199-208
    • /
    • 2003
  • A new technique was proposed for the determination of alkylphenols, chlorophenols and bisphenol A in tap water samples. The sample preparation consists of a solid phase extraction (SPE) of alkylphenols, chlorophenols and bisphenol A from a water sample with XAD-4 and subsequent conversion to isobutyloxycarbonyl (isoBOC) derivatives or tert-butyldimethylsilyl (TBDMS) derivatives for sensitive analysis with the CC/MS SIM mode. The recoveries were 86.6 ∼ 105.2% (isoBOC derivatization) and 97.6∼484.5% (TBDMS derivatization), respectively. The limit of quantitation of alkylphenols, chlorophenols and bisphenol h for SIM were 0.001∼0.050 $\mu\textrm{g}$/1 (isoBOC derivatization) and 0.003∼0.050 $\mu\textrm{g}$/1 (TBDMS derivatization). The SIM responses were linear with the correlation coefficient varying 0.9755∼0.9981 (isoBOC derivatization), and 0.9908∼0.9996 (TBDMS derivatization). When these methods were applied to tap water samples, the range of concentrations were 22.8∼31.3 ng/1 in 2,4-dichlorophenol, 28.6∼70.3 ng/1 in pentachlorophenol, 15.2∼17.4 ng/1 in t-butylphenol, 10.8∼13.2 ng/1 in t-octylphenol and 17.6∼36.3 ng/l in bisphenol A, respectively.

Occurrence of Perchlorate in Drinking Water in Korea (국내 주요 정수장 수돗물의 퍼클로레이트 검출현황)

  • Kim, Hyun-koo;Kim, Joung-hwa;Lee, Youn-hee
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.6
    • /
    • pp.822-828
    • /
    • 2007
  • Perchlorate is an unregulated contaminant but recently many cases of perchlorate contamination have been reported in the US. In Japan, also, a couple of contamination incidents caused by perchlorate occurred. Against this backdrop, investigation on perchlorate was urgent for Korea. Accordingly, perchlorate investigation in tap water and river water was conducted one time a week for seven consecutive weeks at major water sources of Korea including Han River, Guem River, Yeong-san River, and Nak-dong River. Perchlorate was not found at Han River, Guem River, and Yeong-san River. However, all the 4 tap water samples in Nak-dong River recorded high level of perchlorate. Among others, NT1 located at Daegu posted the highest value of $22.3{\mu}g/L$. This level is lower than $24.5{\mu}g/L$, the threshold recommended by US EPA. Still, perchlorate contamination in drinking water can deal a heavy blow to nerve development of infants and children by causing iodine deficiency. At the 1st and 2nd investigations, perchlorate concentration reached $18.7{\sim}95.6{\mu}g/L$ and $4.0{\sim}25.6{\mu}g/L$ respectively, both of which are relatively higher. The high perchlorate concentration in Nak-dong River was possible because of the waste water discharged from LCD manufacturing factory which was located at NS3 in Gumi, Korea. Perchlorate concentration of waste water from the factory was $730{\sim}1,858{\mu}g/L$.

Characteristics of Chlorination Byproducts and Aldehyde Occurrence in Bottled Tap Water (수돗물 병입수 중 염소소독부산물 및 aldehyde의 발생 특성)

  • Lee, Youn-Hee;Park, Ju-Hyun;Kim, Hyun-Koo;Ahn, Kyung-Hee;Kim, Tae-Seung;Kim, Dong-Hoon;Kwon, Oh-Sang
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.5
    • /
    • pp.754-761
    • /
    • 2012
  • Several drinking water treatment plants (DWTPs) produce the bottled tap waters (BTWs) as pilot production and provide them for noncommercial use. In 2008, acetaldehyde and chloral hydrate were detected in some BTWs and the public worry over the safety of the water. In this study, the BTWs produced from 7 DWTPs were tested for 13 chemicals including disinfection byproducts (DBPs). The level of four trihalomethanes (THMs) were increased up to 15 days. The average concentration of them was 0.0075 mg/L at the time of bottling and it was increased to 0.0214 mg/L after 15 days. The average acetaldehyde concentration was 0.0406 mg/L at the time of bottling but it was went up to 0.2251 mg/L after 11 days and then decreased. Although the initial concentrations of DBPs were below the drinking water standard, we also traced them at different storage conditions. Temperature affected the formations of THMs and acetaldehyde concentrations significantly. While the average concentration of THMs ranged from 0.0113 to 0.0182 mg/L at $25^{\circ}C$, it was increased to 0.0132 ~ 0.0256 mg/L at $50^{\circ}C$. In case of acetaldehyde, concentration ranged from 0.0901 to 0.2251 mg/L at $25^{\circ}C$, it was increased to 0.3394 ~ 1.0591 mg/L at $50^{\circ}C$. Throughout the tests with 7 BTWs samples, none of the chemicals was exceeded the drinking water standard of Korea. Therefore, it is recommended to avoid the exposure of BTWs to sunlight or high temperature during distribution and storage.