• 제목/요약/키워드: tank size

검색결과 418건 처리시간 0.025초

자원관리형 반구형 새우통발의 형상 변화에 따른 유체저항 특성과 수중안정성 (On the hydrodynamic resistance and stabilization of the coonstripe shrimp pot to reduce catch of a small size shrimp)

  • 김성훈;이경훈;김형석
    • 수산해양기술연구
    • /
    • 제48권1호
    • /
    • pp.1-9
    • /
    • 2012
  • For the optimal design of a shrimp pot to control the catch size and to reduce catch the small size shrimp, tank experiments were carried out to study the pot stability under water. Tank experiments were carried out to measure the drag with 4 kinds of model pots that have 50% selection on the individual of 25mm carapace length. The drag of each pot was measured every 10 times with changing the current speeds from 0.1m/s to 0.7m/s in 0.1m/s intervals and the pot attack angle from $0^{\circ}$ to $90^{\circ}$ in $15^{\circ}$ interval in a flume tank. The relation between the current speed and drag was presented. The stability of pot was estimated using the drag data and the friction data of Kim et al. (2008b). The results showed that, the drag was shown lower as small as the projected area of pot depending on the current speeds and angles. The model pots were showed to slide on the seabed in case of rock at the current speeds 0.35-0.38m/s and the possibility of turn over at the current speeds 0.77-0.89m/s. In conclusion, the stability of a shrimp pot showed more stable as the pot of the lower the height and the smaller projected area on current.

제과공장의 폐수처리장에서 발생하는 악취 저감 (Reduction of the Offensive Odor from Confectionery Wastewater Plant)

  • 김영식;손병현;조상원;정종현
    • 한국환경보건학회지
    • /
    • 제24권1호
    • /
    • pp.62-69
    • /
    • 1998
  • It has been studied that the measurement of odor component emission at confectionery manufacture. The objects of this study were to investigate reduction of offensive odor. The survey effects of odorous materials are presented as follows. The countermeasure of operating process is to minimize sludge sediment in each unit facility. Especially, in summer, we have to clean the sludge frequently, because anaerobic decomposing is likely to occur easily. The sludge or scum from sedimentation tank pond, and floating tank should be treated quickly. We should avoid overloading operation. In the case of overloading, dissolved oxygen should be increased, the quality of wastewater input should be decreased. When dried cakes from condense tank or floating tank are left in treatment plant, we should cover, to prevent diffusion of smell with masking materials. The seasonal condition of operating should be fixed and the kind of coagulants should be changed because the wastewater in each season have different loading rates and organic materials. Odorous materials are very sensitive to the seasonal temperature variation. Especially, when the amount of rainfall is small and the high temperature of maintenance in long periods, air diffusion rate is large, so odorous materials can make great effect on surroundings comparision with other periods. To reduce odorous gas, as short term method, we had better take ceramic addition method. Especially, in summer we should take ceramic addition method. Also, as long term method, the size of wastewater treatment facility is the most important in the normal operating of wastewater treatment facility. But wastewater treatment facilities in this factory are too old, treatment process is old fashion, and the size is too small. So, large wastewater quantity to treat in summer. As results, the expansion of wastewater treatment facility and the process of improvement are required. Restriction level of odor was exceed. As it is overloaded in summer, the basis cause of odor is that the size of wastewater treatment facility is small. The prediction of air quality equilibrium density variation show that the odorous materials from working place are Amine materials whose smell strength is about 2.5(a little strong degree). We can suppose that in summer is sensitive to temperature variation, smell strength is larger as to reduce the origin of odor. We must expand wastewater treatment facility and improve the process A.S.A.P.

  • PDF

정사각형 수조 진동대실험에 대한 상관해석 (Post-Correlation Analysis for Shake Table Test of Square Liquid Storage Tank)

  • 손일민;김재민;최형석;백은림
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제21권1호
    • /
    • pp.23-29
    • /
    • 2017
  • 이 연구에서는 유체저장탱크의 내진 설계 고도화에 활용하기 위하여 정사각형 수조의 슬러싱 진동대실험에 대한 상관해석을 수행하였다. 이를 위하여 CFD 프로그램인 ANSYS CFX를 이용하였다. CFD 해석 프로그램 검증을 위해 슬러싱 공진이 발생하는 운동에 대한 해석모델의 요소크기 및 난류모델에 대한 슬러싱응답의 민감도해석을 수행하였다. 그 결과, 수직방향 요소크기 뿐만 아니라 수평방향 요소크기에 따라 수위 예측에 민감한 영향을 미치는 것을 알 수 있었다. 또한, SST 난류모델을 사용한 CFD해석 결과가 실험 결과와 매우 잘 일치하는 것을 알 수 있었다. 이로부터 결정된 CFX 해석모델을 사용하여, 가진 주파수와 가진 진폭이 다른 3가지 실험 결과에 대하여 상관해석을 수행하였다. 그 결과, CFD해석모델을 사용하여 지진해석을 수행할 경우, 슬러싱응답이 실험 결과와 매우 잘 일치하는 것을 알 수 있었다.

일반 수조에서의 합성 얼음의 밀도변화에 따른 쇄빙선의 저항특성 연구 (Study on Resistance of Icebreaker by Density Variation of Synthetic Ice in General Towing Tank)

  • 임태욱;김문찬;전호환
    • 한국해양공학회지
    • /
    • 제22권5호
    • /
    • pp.83-86
    • /
    • 2008
  • This paper deals with the experimental works for the correlations of ice resistance for icebreaker with synthetic(model) ice in general towing tank and with refrigerated ice in ice tank. In order to find out the correlation, the density variation is mainly focused in the present study. The model of Terry-Fox ice breaker has been used for the present correlation study because many data are available to be compared. According to the increase of density, the correlation becomes better quantitatively as well as qualitatively. Other parametric studies such as an ice size, a friction coefficient, a bending moment, etc., are also expected to be carried out to have better correlation in a near future. This research could be the basis for the possibility of resistance test using a synthetic ice in a general towing tank instead of an expensive ice tank.

IMO C형 독립탱크의 설계치수 계산과정 및 평가방법에 대한 고찰 (Consideration for IMO Type C Independent Tank Rule Scantling Process and Evaluation Methods)

  • 허광현;강원식;박봉균
    • 대한조선학회 특별논문집
    • /
    • 대한조선학회 2017년도 특별논문집
    • /
    • pp.93-104
    • /
    • 2017
  • IMO type C independent tank is one of the cargo containment system specified on IGC code. It is normally adopted for small and medium size liquefied gas carrier's cargo containment system and it can be applied to fuel tank of LNG fueled vessel. This study focuses on rule scantling process and evaluation methods in early design stage of type C independent tank. Actual design results of 22K LPG/Ammonia/VCM carrier's No.2 cargo tank are demonstrated. This paper presents the calculation methods of design acceleration and liquid height for internal design pressure as defined on IGC code. And this paper shows the applied results of classification rules about shell thickness requirement and buckling strength. Additionally this paper deals with evaluation methods of structural strength and cumulative fatigue damage using FE analysis.

  • PDF

반응기촉매 교체작업시 최적 환기조건에 대한 수치해석적 연구 (A numerical Study on Optimum Ventilation Conditions for the Task of Exchange Catalyst)

  • 윤장근;임용순;신미수
    • 한국산업보건학회지
    • /
    • 제28권2호
    • /
    • pp.190-199
    • /
    • 2018
  • Objectives: The purpose of this case study is to assess the current airflow and find the ideal ventilation conditions in tank reactors for minimizing the possibility of exposure respiratory dusts(size of $2.5{\mu}m$, $10{\mu}m$) when workers exchange catalysts in the tank reactors. Methods: A Numerical study was performed to determine ideal ventilation conditions, We considered two sizes of airborne respiratory particles($2.5{\mu}m$, $10{\mu}m$) at 12points from the bottom of tank reactor. We changed input & output ventilation conditions and analyzed the particle motion in the tank reactor. The star-ccm+, computational fluid dynamics tool was used to predict air & particle flow patterns in the tank reactor and a numerical simulation was achieved by applying the realized ${\kappa}-{\varepsilon}$ turbulence model and the Lagrangian particle tracking method. Results: From the results, the increase of recirculation air had a significant impact on removing dusts because they are removed by HEPA filter. To the contrary, Increasing the clean air quantity or changing the input position of clean air is not good for workers because it causes the exit of respiratory dusts through workers' entrance or cause it to remail suspended in the air in the workplace tank.

진동대 실험을 통한 외부보강형 판넬조립식 물탱크의 내진성능평가 (Seismic Performance Evaluation of Externally Reinforced Panel Water Tank Using Shaking Table Tests)

  • 박세준;원성환;최문석;김상효;정진환
    • 한국지진공학회논문집
    • /
    • 제17권4호
    • /
    • pp.151-157
    • /
    • 2013
  • In this study, an externally reinforced structural system for SMC(Sheet Molding Compound) panel water tank, designed according to the Japanese design code, is experimented to evaluate its seismic performance. The test tank is 3m long, 2m wide and 3m high, considering the capacity and size of the shaking table. The measured hydrodynamic pressures are found to be approximately 70% of the Japanese design code values. It may be partially due to the convex shape effect of the unit panels. The analytical results of externally reinforced system based on the measured dynamic water pressures are found in good agreement with the test results. If the design hydrodynamic pressures are estimated properly, the proposed analytical model for the externally reinforced water tank becomes a useful design tool and the Japanese design code is found to provide a safe design for the external frames of SMC panel water tank.

Numerical analysis for behavior of outer concrete tank in emergency LNG spillage

  • Lee, Jeong Su;Park, Chan Kyu;Lee, Yun;Kim, Ji-Hoon;Kwon, Seung Hee
    • Computers and Concrete
    • /
    • 제14권4호
    • /
    • pp.369-385
    • /
    • 2014
  • In the existing method for analyzing the liquid tightness of the outer concrete tank in an emergency LNG spillage, the temperature variation over time inside the tank, and the concrete properties dependent on temperature and internal moisture content, have not been taken into account. In this study, the analyses for a typical LNG concrete tank subjected to thermal load due to spillage were performed with three different cases: the existing method was adopted in the first case, the transient temperature variation was considered in the second, and the temperature-moisture content dependent concrete properties were taken into account as well as the transient states of temperature in the third. The analysis results for deformation, compressive zone size, cracking, and stress of reinforcements were compared, and a discussion on the difference between the results obtained from the different analysis cases was made.

시판소녀용 브래지어 착용실험 (Wearing Test of Brassiere for Girls)

  • 이경화
    • 복식
    • /
    • 제50권3호
    • /
    • pp.73-86
    • /
    • 2000
  • This study is to develop the well-fit brassieres by wearing test of available brassieres for girls . The 11 elementary school girls aged 12 participated in the wearing test. The test procedure consisted of a rating on fit and performance according to brassiere types, a try on test of 3 types of brassiere and a sensory test on fit. The results of this study are as follows ; 1. The results of fit rating on different brassieres. Compared among brassiere types, tank top type proved the most effective, from a viewpoint of wearing effects. All types of brassiere performed well in bust up effect. Especially tank top type brassiere showed the best of them. 2. The results of the sensory test and comparative test. With regard to wear comfort, most of the subject assessed tank top brassiere to be the most comfortable . As for freedom of movement, it is disclosed that the subjects prefer tank top brassiere. As a result, brassiere for girls strongly require size adjustment, physical and psychological comfort through full overage of breast area.

  • PDF

A REVIEW FOR DEVELOPING THERMODYNAMIC MODEL OF COMS CPS

  • Chae, Jong-Won;Han, Cho-Young;Yang, Koon-Ho
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2007년도 Proceedings of ISRS 2007
    • /
    • pp.179-182
    • /
    • 2007
  • COMS (Communication, Ocean and Meteorological Satellite) is a geosynchronous satellite and has been developing by KARI and Astrium for Ka-band communication, ocean observation and meteorological observation. COMS Chemical Propulsion System (CPS) uses a bipropellant propulsion subsystem, which is applied for transferring COMS from GTO to GEO (mission orbit) and implementing station-keeping manoeuvres. In this paper COMS CPS is briefly introduced for understanding. A few of mathematical thermodynamic modelings of bipropellant propulsion system in literatures are reviewed and authors has studied those models for developing a computer program, which predicts variations of thermodynamic properties such as temperature and pressure histories in the helium pressurant tank, MMH propellant tank and NTO propellant tank during LAE firing and on-orbit manoeuvrings. The CPS thermodynamic model may be used to compute pressurant and propellant masses and to size tank volumes.

  • PDF