• 제목/요약/키워드: tank size

검색결과 418건 처리시간 0.02초

스프링그물통발의 입구 크기에 따른 붕장어 어획성능과 혼획 (Fishing capacity and bycatch on spring net pot for conger eel by entrance size)

  • 송대호;조삼광;차봉진
    • 수산해양기술연구
    • /
    • 제52권1호
    • /
    • pp.9-16
    • /
    • 2016
  • This study was conducted to analyze fishing capacity and bycatch by mesh size and entrance size of spring net pot conducted by water tank and field experiment. The water tank experiments were conducted by using traps with mesh size of 22 mm and entrance size of 120 mm and 140 mm, respectively in the water tank of NIFS. The field experiment was conducted using 5 kinds of spring net pot with mesh sizes of 20 mm, 22 mm, 35 mm and entrance size of 120 mm, 130 mm, 140 mm, 360 mm by coastal trap fishery vessel operating around the area of Geoje island. In the result of water tank experiments, the catch of conger eel was 1.5 times higher when using trap with entrance size of 140 mm than that of 120 mm. In the field experiment, when using same mesh size, the larger the entrance size, the higher amount of conger eel catch, bycatch and number of bycatch species. When using the same entrance size, the larger the mesh size, the lower amount of conger eel catch and number of bycatch species, whereas the amount of bycatch showed increasing trend.

군대 전차포 훈련장에서의 소음노출 특성 (Characterization of Noise Exposure in the Tank Gun Drill Ranges)

  • 황성호;박재범
    • 한국산업보건학회지
    • /
    • 제24권1호
    • /
    • pp.74-78
    • /
    • 2014
  • Objectives: Purpose of this study was to evaluate the noise level exposures at the different cannonball type and locations in the tank gun drill ranges. Methods: We visited the tank gun drill ranges and measured with a sound level meter(3M Quest SoundPro$^{TM}$) with the value of Peak(dB(A)). Results: The highest peak value of impulse noise level averaged 166.3 dB(A) at the site of loading solider. The highest peak value of impulse noise level by size of cannonball averaged 165.9 dB(A) at the 120 mm size cannonball of the tank. This result was significantly different from the other size of cannonballs such as 7.62 mm, 90 mm, and 105 mm(p < 0.001). Among the four types of soldier site on the tank, average noise levels of loading soldier, 156.6 dB(A), were higher than the other three types of soldier site (p > 0.05). Conclusions: This study confirmed that there were needed for a proper control to reduce the amount of impulse noise exposure at the tank gun drill ranges.

건축물 지붕과 연결된 빗물저류조의 적정 규모 결정에 관한 고찰: 수원지역을 중심으로 (A Discussion on Determination of Suitable Size of Rain Tank Connected to Building Roof in Suwon District)

  • 노희성;안태진
    • 한국습지학회지
    • /
    • 제24권3호
    • /
    • pp.161-169
    • /
    • 2022
  • 본 연구에서는 수원지방에서 효율적이고 타당한 빗물저류조의 용량을 평가하기 위하여 수원강우관측소의 월평균강수량, 일강수량변동곡선 및 일강우일수를 분석하였다. 빗물저류조 용량별 연평균빗물사용량 및 일평균저수량은 빗물저류조내 유입되는 일강수량, 일수요량, 빗물저류조의 용량 등을 일단위 연속방정식에 적용하여 산정하였다. 빗물저류조 용량별 연평균빗물사용량, 이용효율, 저류조 사용일수, 저류조의 일평균저수량, 일별수요량 등을 감안하여 빗물저류조의 용량을 평가하면 물의 재이용 관련 법령에서 제시한 활용강우량 50.0mm 이상은 과다한 빗물저류조의 용량인 것으로 판단된다. 따라서 지역별로 타당하게 제시될 일별 수요량, 빗물사용량에 따른 빗물저류조 용량별 편익, 빗물저류조 용량별 설치비용 등을 감안하여 빗물 저류조의 활용강우량 즉 빗물저류조의 용량을 결정하는 것이 합리적임을 보여주었다.

장방형 침전지에서 길이에 따른 슬러지 floc의 형태에 관한 연구 (Morphological Parameters of the Sludge Flocs in a Long Rectangular Secondary Settling Tank)

  • 김영철;이진우;강민기
    • 한국물환경학회지
    • /
    • 제22권3호
    • /
    • pp.468-474
    • /
    • 2006
  • In the secondary settling tanks, three different types of settling phenomena occurs; i.e., zone settling for sludge thickening in the bottom part of settling tank, and discrete and flocculent settling for clarification in the upper part. In this paper, morphological parameters of the floc in sludge blanket layers along the length of a long rectangular tank were investigated. The plant used for this study had a serious bulking problem caused by Microthrix parvicella. Floc size decreased as the surface area of settling tank increases, which indicates that in the secondary settling tank where zone settling believed to be predominant, free or flocculent type of settling contributes to floc size distributions. Large floc particles deposit in the front zone of settling tank, but small and loose flocs mostly in the zone near its outlet. On the other hand, filament length contained in one gram of sludge blanket solid increases along the flow direction. Large flocs with less filaments settle faster, but small flocs having more filaments result in poor settling. These results support function of microorganism selection occurring in secondary settling tank. In addition, designing a long rectangluar settling tank with double hoppers might be one of the ways of bulking control, but this idea has to be verified with a further study.

송수펌프용량 및 배수지규모에 따른 송·배수시스템의 운영비용 및 체류시간 분석 (Sensitivity analysis of pump and tank sizes on water network operation and water age)

  • 김강민;최정욱;정동휘;강두선
    • 한국수자원학회논문집
    • /
    • 제50권12호
    • /
    • pp.803-813
    • /
    • 2017
  • 최근 송 배수시스템의 최적 펌프운영과 펌프 및 배수지의 적정용량 산정을 위한 다양한 연구가 진행되고 있다. 시설물의 적정 용량을 선정하기에 앞서 송수펌프 용량 및 배수지규모에 따른 시스템 비용(건설 및 운영비용) 과 시스템 내 수질 변화를 분석하는 과정이 필요하다. 본 연구에서는 민감도 분석을 통해 송수펌프 용량과 배수지의 크기가 실제 시스템의 건설 및 운영비용, 그리고 시스템 전반의 수질에 미치는 영향을 분석하였다. 국내 대규모 지방상수도 시스템을 대상으로 분석을 실시하여 시설물 규모가 비용 및 수질에 미치는 영향을 명확히 파악하였다. 적용 네트워크의 경우, 시설물의 용량이 증가할수록 운영비용은 감소하지만, 설계비용은 증가하는 것으로 나타났으며, 이를 통해 비용최소화와 수질안정화를 동시에 만족하는 시설물의 적정용량 범위를 파악할 수 있을 것으로 판단된다.

Mass-balance 및 경제성 분석에 의한 빗물저류시설 적정 규모 산정 (Estimation of Optimum Capacity for Rainwater Storage Facilities based on Mass Balance and Economic Analysis)

  • 김영민;이상호;이정훈;김이호
    • 상하수도학회지
    • /
    • 제22권2호
    • /
    • pp.233-238
    • /
    • 2008
  • Recently, rainwater harvesting facilities have increasingly constructed mainly in elementary schools and government buildings. Nevertheless, few methods are available for efficient planning and design of rainwater harvesting facilities by considering the weather conditions and purpose of rainwater management in each site, which may lead to a construction of uneconomic facilities. The current method estimates the size of rainwater storage tank by multiplying the size of building or plottage with a certain ratio and has many limitations. In this study, we first developed a method for planning and design of rainwater storage facilities using $Rainstock^{TM}$ model, which is based on mass balance, and economic analysis. Then, the model was applied for the design of a rainwater harvesting facility in a building with the catchment area of $1,000m^2$. The model calculation indicated that the economic feasibility of rainwater harvesting depends on not only the size of storage tank but also the water usage rate. When the water usage rate is $1m^3/day$, the rainwater harvesting facility is not cost-effective regardless of the size of the storage tank. With increasing the water usage rate, the economical efficiency of the facility was improved for a specific size of the storage tank. Based on the model calculation, the optimum tank sizes for $5m^3/day$ and $10m^3/day$ of water usage rates were $24m^3$ and $57m^3$, respectively. It is expected that the model is useful for optimization of rainwater storage facilities in planning and designing steps.

염산 운송차량의 누출공 크기와 누출률 및 영향범위간 상관관계 연구 (A Study on the Correlation between Leak Hole Size, Leak Rate, and the Influence Range for Hydrochloric Acid Transport Vehicles)

  • 전병한;김현섭
    • 한국환경보건학회지
    • /
    • 제47권2호
    • /
    • pp.175-181
    • /
    • 2021
  • Objectives: The correlation between the size of a leak hole, the volume of the leakage, and the range of influence was investigated for a hydrochloric acid tank-lorry. Methods: For the case of a tank-lorry chemical accident, KORA (Korea Off-site Risk Assessment Supporting Tool) was used to predict the leak rate and the range of influence according to the size of the leak hole. The correlation was studied using R. Results: As a result of analyzing the leak rate change according to the leak hole size in a 35% hydrochloric acid tank-lorry, as the size of the leak hole increased from 1 to 100 mm, the leak rate increased from 0.008 to 83.94 kg/sec, following the power function. As a result of calculating the range of influence under conditions ranging from 1 to 100 mm in size and 10 to 60 minutes of leakage time, it was found that the range spanned from a minimum of 5.4 m to a maximum of 307.9 m. As a result of multiple regression analysis using R, the quadratic function model best explained the correlation between the size of the leak hole, the leak time, and the range of influence with an adjected coefficient of determination of 0.97 and a root mean square error of 22.33. Conclusion: If a correlation database for the size of a leak hole is accumulated for various substances and under various conditions, the amount of leakage and the range of influence can easily be calculated, facilitating field response activities.

날개형 및 격막형 배플을 이용한 유체저장탱크 내부의 슬로싱 저감 연구 (A Study on the Reduction of the Sloshing of Storage Tank Using Wing and Diaphragm Baffle)

  • 이영신;김현수;이재형;김영완;고성호
    • 대한기계학회논문집A
    • /
    • 제27권12호
    • /
    • pp.2039-2046
    • /
    • 2003
  • Storage tank filled with fluid has unique dynamic characteristics compared to general structures, due to the interaction between fluid and structure. The oscillation of the fluid surface caused by external forces is called sloshing, which occurs in moving vehicles with contained liquid masses, such as trucks, railroad cars, aircrafts, and liquid missles. In this study, the evaluation method for the reduction of sloshing, the optimized size and location of wing and diaphragm baffles are suggested based on the experimental results. The experimental device can simulate the translation motion. A rectangular tank and various baffles are fabricated to study on the sloshing characteristics. The forces measured using the load cell at tank wall and those are compared with each other through the Fourier transformation for various conditions. The study of the sloshing of the rectangular tank equipped with baffles is conducted under the same conditions with non-baffled rectangular tank experiment. From the experimental results, the sloshing reduction effect by the baffles is observed. In conclusion in case of diaphragm baffles, the optimized size ratio of the width of baffle to the water height is 0.44 and the installation location has no effect to the damping of sloshing. In case of wing baffles, the optimized size ratio of the width of baffle to the length of a rectangular tank is 0.1 and the optimized location ratio of the baffle to the water height is 0.9.

내부재가 설치된 직육면체 화물창 내의 Sloshing 고유주기 산정 (An Analytic Solution to Sloshing Natural Periods for a Prismatic Liquid Cargo Tank with Baffles)

  • 신장룡;최경식;강신영
    • 한국해양공학회지
    • /
    • 제19권6호통권67호
    • /
    • pp.16-21
    • /
    • 2005
  • In the design of super tankers or LNG carriers, which transport a large amount of liquid in the cargo tanks, the structural d11mage due to liquid sloshing is an important problem. The impact pressure from sloshing is most violent when the liquid motion of a partially filled tank is in resonance with the motion of a ship. In this study, the sloshing natural periods of a baffled tank, often installed to reduce liquid motion, is analyzed. A variational method is adopted to estimate the sloshing natural periods for a prismatic cargo tank with baffles of arbitrary filling depth of liquid; the results are compared with Lloyd's Register regulations on sloshing periods. In this study, using an effective liquid-fill-depth concept, sloshing periods for a baffled tank can be expressed by the same form as rectangular prismatic tanks without baffles. In contrast to Lloyd's Register regulations, which can be applicable only to cargo tanks with constant baffle size and distribution, the present results can be applicable to cases of variable baffle size and distribution.

빙축열시스템의 실질적인 최대 축열 가능량 예측 (Prediction of practically chargeable cold energy in an ice storage system)

  • 이대영;강병하;김민수
    • 설비공학논문집
    • /
    • 제11권1호
    • /
    • pp.133-146
    • /
    • 1999
  • The charge operation of an ice storage system has been analyzed in this paper. The thermal characteristics of major components of the ice storage system. i.e., the refrigerator and the ice storage tank are evaluated from performance tests on an existing ice storage system. Based on the measured data for thermal characteristics, a simulation is carried out for the charge operation and the effect of the refrigerator size on the system performance is investigated. The results indicate that the larger the refrigerator size for a given storage capacity, the lower the inlet temperature of the ice storage tank so that the lower the efficiency of charge operation. It is also found that there exists an optimal size of the refrigerator with which the ice storage at the end of the charge operation is maximized, but the complete charge is not possible even with the optimally sized refrigerator. This leads to the result that the design capacity of the storage tank should be larger than the required amount of cold energy for the daytime cooling considering the practically chargeable amount of cold energy during the nighttime. Where the cooling load sharing of the storage is 40%, the nominal capacity of an ice storage tank needs to be larger than the required storage amount by 30%.

  • PDF