• 제목/요약/키워드: tandem mass spectrometry coupled with liquid chromatography

검색결과 63건 처리시간 0.024초

Determination of Ceftiofur Residues by Simple Solid Phase Extraction Coupled with Liquid Chromatography-Tandem Mass Spectrometry in Eel, Flatfish, and Shrimp

  • Kim, Joohye;Shin, Dasom;Kang, Hui-Seung;Lee, Eunhye;Choi, Soo Yeon;Lee, Hee-Seok;Cho, Byung-Hoon;Lee, Kang-Bong;Jeong, Jiyoon
    • Mass Spectrometry Letters
    • /
    • 제10권2호
    • /
    • pp.43-49
    • /
    • 2019
  • The aim of this study was conducted to develop an analytical method to determine the concentration of ceftiofur residue in eel, flatfish, and shrimp. For derivatization and extraction, the sample was hydrolyzed with dithioerythritol to produce desfuroylceftiofur, which was then derivatized by iodoacetamide to obtain desfuroylceftiofur acetamide. For purification, the process of solid phase extraction (Oasis HLB) was used. The target analytes were confirmed and quantified in $C_{18}$ column using liquid chromatography-tandem mass spectrometry with 0.1% formic acid in water (A) and 0.1% formic acid in acetonitrile (B) as the mobile phase. The linearity of the standard calibration curve was confirmed by a correlation coefficient, $r^2>0.99$. The limit of quantification for ceftiofur was 0.002 mg/kg; the accuracy (expressed as the average recoveries) was 80.6-105%; the precision (expressed as the coefficient of variation) was below 6.3% at 0.015, 0.03, and 0.06 mg/kg. The validated method demonstrated high accuracy and acceptable sensitivity to meet the Codex guideline requirements. The developed method was tested using market samples. As a results, ceftiofur was detected in one sample. Therefore, it can be applied to the analysis of ceftiofur residues in fishery products.

High throughput automated 96-well solid-phase extraction and liquid chromatography-tandem mass spectrometric analysis of beraprost in human plasma

  • Chang, Kyu-Young;Kim, Ho-Hyun;Lee, Hee-Joo;Lee, Kyung-Ryul
    • 대한약학회:학술대회논문집
    • /
    • 대한약학회 2003년도 Proceedings of the Convention of the Pharmaceutical Society of Korea Vol.2-2
    • /
    • pp.224.1-224.1
    • /
    • 2003
  • A sensitive and selective liquid chromatographic method coupled with tandem mass spectrometry (LC-MS/MS) was developed for the determination of beraprost in human plasma. Plasma samples were transferred into 96-well OASIS HLB extraction plate using an automated sample handling system and the drugs were eluted with methanol. The eluents were then evaporated and reconstituted with water. All sample transfer and solid-phase extraction (SPE) was automated through the application of both the PerkinElmer MultiPROBE II HT and TOMTEC Quadra 96 workstation. (omitted)

  • PDF

Determination of S- and R-Amlodipine in Rat Plasma using LC-MS/MS After Oral Administration of S-Amlodipine and Racemic Amlodipine

  • Yoo, Hye-Hyun;Kim, Tae-Kon;Lee, Bong-Yong;Kim, Dong-Hyun
    • Mass Spectrometry Letters
    • /
    • 제2권4호
    • /
    • pp.88-91
    • /
    • 2011
  • The pharmacokinetic properties of S-amlodipine were studied using racemic amlodipine and single S-enantiomer (SK310) administration to rats. Plasma levels of the drug were determined using chiral liquid chromatography coupled with tandem mass spectrometry following solid phase extraction. The stereospecific analysis of amlodipine was performed on an ${\alpha}$-acid glycoprotein (AGP) column using a mobile phase comprising 10 mM ammonium acetate (pH 4.0) and propanol at a flow rate of 0.2 mL/min. This method was used to perform a comparative study of the pharmacokinetics of amlodipine and SK310. The results revealed that the pharmacokinetic profile of S-amlodipine after the administration of SK310 was comparable to that following the administration of the racemic mixture.

Development and Validation of an Analytical Method for Glucuronolactone in Energy Drinks by Hydrophilic Interaction Liquid Chromatography-electrospray Tandem Mass Spectrometry

  • Oh, Mi Hyune;Lim, Moo Song;Chai, Jeung Young;Kim, Eun Jung;Cho, Joong Hoon;Lim, Chul Joo;Choi, Sun Ok
    • 한국식품위생안전성학회지
    • /
    • 제32권2호
    • /
    • pp.89-95
    • /
    • 2017
  • 에너지 음료는 카페인을 주성분으로 타우린, 비타민 같은 다른 energy-enhancing 성분을 함유하고 있다. 미국과 유럽에서는 글루쿠로노락톤이 에너지 음료에 첨가될수 있으나, 국내에서 의약품으로는 허가되어 있다. 따라서 식품 첨가물로는 그 사용이 금지 되어 있어, 지속적으로 수입 및 유통 음료에서 시험검사를 하여 규제하고 있다. 현재 분석법으로 사용하는 LC-PDA 법은 복잡한 유도체화 과정을 거치고, 음료 중에 당류들이 위양성 결과를 나타내기도 한다. 이런 기존 방법의 단점을 개선하기 위해 HILIC-ESI-MS/MS(hydrophilic interaction liquid chromatography coupled to electrospray ionization tandem mass spectrometry)를 이용한 분석법을 개발하고, 선택성, 직선성, 검출한계, 정량한계, 정밀도, 정확성, 재현성에 대하여 분석법 유효성 검증을 수행했고, AOAC, EURACHEM 가이드라인에 부합되는 결과를 얻었다.

LC-MS/MS를 이용한 돼지 근육조직 중 dl-methylephedrine hydrochloride의 잔류 분석법 개발 (Development of an analytical method for the determination of dl-methylephedrine hydrochloride in porcine muscle using liquid chromatography-tandem mass spectrometry)

  • 최원석;김석;이후장
    • 대한수의학회지
    • /
    • 제60권4호
    • /
    • pp.209-213
    • /
    • 2020
  • This study examined the residue of dl-methylephedrine hydrochloride (MEP) on the muscle of pigs administered orally with MEP 12 g/ton feed for seven consecutive days. Twenty healthy cross swine were administered MEP. Four treated animals were selected arbitrarily to be sacrificed at 1, 2, 3, 4, and 5 days after treatment. MEP residue concentrations in the muscle were determined by liquid chromatography coupled with tandem mass spectrometry. The drug was extracted from muscle samples using 10 mM ammonium formate in acetonitrile followed by clean-up with n-hexane. The analyte was separated on an XBridgeTM hydrophilic interaction liquid chromatography column using 10 mM ammonium formate in deionized distilled water and acetonitrile. The correlation coefficient (R2) of the calibration curve was 0.9974, and the limits of detection and quantification were 0.05 and 0.15 ㎍/kg, respectively. The recoveries at three spiking levels were 94.5-101.2%, and the relative Standard Deviations was less than 4.06%. In the MEP-treated group, MEP residues on one day post-treatment were below the maximum residue limit in the muscle. The developed method is sensitive and reliable for the detection of MEP in porcine muscle tissues. Furthermore, it exhibits low quantification limits for animal-derived food products destined for human consumption.

Analysis of antibiotic residues in milk from healthy dairy cows treated with bovine mastitis ointment using ultra-performance liquid chromatography coupled with electrospray tandem mass spectrometry

  • Park, Eun-Kee;Ryu, Yong-Jae;Cha, Chun-Nam;Yoo, Chang-Yeul;Kim, Suk;Lee, Hu-Jang
    • 대한수의학회지
    • /
    • 제56권4호
    • /
    • pp.233-239
    • /
    • 2016
  • This study was conducted to analyze penicillin G (PEG), streptomycin (STR) and neomycin (NEO) residues in milk of healthy lactating cows. Milk samples were collected from all four quarters of 12 dairy cows 2−7 days after intramammary infusions of an ointment containing PEG, STR and NEO once (n = 4; group I) or twice (n = 4, group II) daily. Ultra-performance liquid chromatography coupled with electrospray tandem mass spectrometry was used to determine the antibiotic residues in the samples. The correlation coefficient ($r^2$) of the calibration curves for all antibiotics was > 0.999 and the limits of detection and quantification were $0.002-0.005{\mu}g/mL$ and $0.007-0.02{\mu}g/mL$, respectively. Recovery rates were ranged from 75.5 to 92.3%. In group I, PEG, STR and NEO residues were detected in milk at 2, 3 and 2 days post-treatment, respectively, which were below the maximum residue limit (MRL). In group II, PEG, STR and NEO residues were detected in milk at 2, 3 and 3 days post-treatment, respectively, which were bellow the MRL. These results suggest that a 3-day for milk withdrawal period after the ointment treatment might be sufficient for reduction of the antibiotic residues below the MRL.

LC/MS/MS를 이용한 수중의 카바릴·유기인계 농약 동시분석 (Simultaneous determination of carbaryl & organophosphorous pesticides in water by liquid chromatography-tandem mass spectrometry)

  • 박근영;신정철;표동진
    • 분석과학
    • /
    • 제31권1호
    • /
    • pp.39-46
    • /
    • 2018
  • 온라인 고체상 추출을 이용한 LC/MS/MS를 사용하여 carbaryl과 유기인계 농약 7 종을 동시에 분석하는 방법을 확립하였다. 분석 대상농약은 carbaryl, diazinon, methyl-demeton, fenitrothion, malathion, parathion, phenthoate, EPN 등 8 종이다. 본 연구에서는 온라인 고체상 추출과 LC/MS/MS의 ESI positive mode로 전처리 없이 물 시료 $500{\mu}L$를 직접 주입하여 10분안에 분석하였다. 농약 8 종의 회수율은 86.8~100 % 였고, 정확도는 90.6~98.8 %로 90 %이상이었고, 정밀도는 1.3~5.2 %로 나타났으며 검출한계 및 정량한계는 각각 $0.05{\sim}0.28{\mu}g/L$, $0.16{\sim}0.89{\mu}g/L$ 였다. $0.5{\mu}g/L$에서 $8.0{\mu}g/L$까지 다섯 개의 농도로 검량선을 작성한 결과 모든 물질의 상관계수(r2)가 0.99이상을 나타냈다. 방법의 유효성 평가를 한 결과 모든 내용에서 적합하므로확립한 분석방법으로 수질 시료에서 농약을 조사한 결과 모두 검출되지 않았다.

Capillary Size-exclusion Chromatography as a Gel-free Strategy in Plasma Proteomics

  • Cho, Man-Ho;Wishnok, John S.;Tannenbaum, Steven R.
    • Molecular & Cellular Toxicology
    • /
    • 제1권2호
    • /
    • pp.87-91
    • /
    • 2005
  • Although 2D-PAGE has been widely used as the primary method for protein separation, difficulties in displaying proteins with an extreme values of isoelectric paint (pI), molecular size and hydrophobicity limit the technique. In addition, time consuming steps involving protein transfer and extraction from the gel-pieces can result in sample loss. Here, we describe a novel protein separation technique with capillary size-exclusion chromatography (CSEC) for rapid protein identification from human plasma. The method includes protein fractionation along with molecular size followed by in-solution tryptic digestion and peptide analysis through reversed phase liquid chromatography (RPLC) coupled to nanoflow electrospray-tandem mass spectrometry (ESI-MS/MS). Tryptic peptides are applied an a $100\;{\mu}m\;i.d.{\times}10mm$ length pre-column and then separated on a $75\;{\mu}m{\times}200mm$ analytical column at -100 nL/min flaw rate. Proteins were identified over the wide ranges of pI (3.7-12.3) when this technique was applied to the analysis of $1-2\;{\mu}L$ of human plasma. This gel-free system provides fast fractionation and may be considered a complementary technique to SDS-PAGE in proteomics.

고속액체크로마토그래피 텐덤질량분석기법을 이용한 사람 혈장 내 소라페닙 농도분석법의 개발 및 검정 (Development and Validation of the Determination of Sorafenib in Human Plasma using Tandem Mass Spectrometry Coupled with Liquid Chromatography)

  • 박대진;이성곤;김우미
    • 생명과학회지
    • /
    • 제22권11호
    • /
    • pp.1456-1462
    • /
    • 2012
  • 소라페닙은 멀티카이네즈 억제제로서 신세포암, 전이성 간세포암 환자의 치료에 효과가 입증된 경구용 항암제이다. 이 연구의 목적은 고속액체크로마토그래피 텐덤질량분석기법(LC/MS/MS)을 이용하여 사람 혈장 내 소라페닙의 농도를 측정하는 효율적인 방법을 개발하고 한국식품의약품안전청(KFDA) 기준에 따라 분석법을 검정하는 것이다. 혈장시료($100{\mu}l$)에 내부표준물질인 chlorantraniliprole을 첨가한 후 이소프로필알콜과 에틸아세테이트로 구성(1:4, v/v)된 0.1% 포름산 함유 추출용액을 혼합하였다. 원심분리 후 상층액을 취하여 원심감압농축하였다. 잔사를 이동상에 재용해하고 Waters사의 역상 XTerra$^{TM}$ C18 칼럼(입자크기 $3.5{\mu}m$)을 장착한 고속액체크로마토그래피 장치에 주입하였다. 액체크로마토그래피는 0.1% 포름산과 10 mM 암모늄 포메이트를 함유한 버퍼용액과 메탄올, 아세토나이트릴을 각각 1:6:3으로 혼합한 용액을 이동상으로 사용하였으며 5분 내에 측정을 완료하였다. 분석대상 물질들은 텐덤질량분석기에서 electrospray 양이온 이온화($ES^+$) 검출방식으로 확인하였으며 소라페닙은 'm/z 465.2 ${\rightarrow}$ 252.5', chlorantraniliprole은 'm/z 484.4 ${\rightarrow}$ 286.2'으로 구성한 multiple reaction monitoring 방법을 사용하였다. 검정 결과, 2-5,000 ng/ml의 농도 구간에서 양호한 직선성($r^2$ > 0.99)과 정확도(90.7-103.9%), 정밀도(10% 이하)를 나타내었다. 새롭게 개발된 LC/MS/MS을 이용한 사람 혈장 내 소라페닙의 농도 측정법은 KFDA 기준을 만족하였으며, 기존의 방법에 비해 민감도가 높은 방법이었다.

Optimization of HPLC-tandem mass spectrometry for chlortetracycline using response surface analysis

  • Bae, Hyokwan;Jung, Hee-Suk;Jung, Jin-Young
    • Environmental Engineering Research
    • /
    • 제23권3호
    • /
    • pp.309-315
    • /
    • 2018
  • Chlortetracycline (CTC) is one of the most important compounds in antibiotic production, and its distribution has been widely investigated due to health and ecological concerns. This study presents systematic approach to optimize the high-performance liquid chromatography-tandem mass spectrometry for analyzing CTC in a multiple reaction monitoring mode ($479{\rightarrow}462m/z$). One-factor-at-a-time (OFAT) test with response surface analysis (RSA) was used as optimization strategy. In OFAT tests, the fragmentor voltage, collision energy, and ratio of acetonitrile in the mobile phase were selected as major factors for RSA. The experimental conditions were determined using a composite in cube design (CCD) to maximize the peak area. As a result, the partial cubic model precisely predicted the peak area response with high statistical significance. In the model, the (solvent composition) and (collision $energy^2$) terms were statistically significant at the 0.1 ${\alpha}$-level, while the two-way interactions of the independent variables were negligible. By analyzing the model equation, the optimum conditions were derived as 114.9 V, 15.7 eV, and 70.9% for the fragmentor voltage, collision energy, and solvent composition, respectively. The RSA, coupled with the CCD, offered a comprehensive understanding of the peak area that responds to changes in experimental conditions.