• Title/Summary/Keyword: tall steel structures

Search Result 98, Processing Time 0.019 seconds

Performance Based Fire Engineering in the UK

  • Plank, Roger
    • International Journal of High-Rise Buildings
    • /
    • v.2 no.1
    • /
    • pp.1-9
    • /
    • 2013
  • This paper reviews the recent developments in fire engineering and the design approaches which are being used in the UK, compared with traditional prescriptive solutions. The research background which has underpinned this is briefly summarised, and the benefits of these more advanced methods are discussed. The focus is on structural fire engineering, but some consideration of modelling fires is also included. Some of the more commonly used design tools are discussed, together with the relative benefits they offer. The use of these more advanced approaches is then outlined in the context of which building types might be most suitable, and a number of case studies are included to illustrate this. Likely future developments are also discussed.

A Study on the control force of HMD for vibration control of the tall building structure (고층 구조물의 진동제어를 위한 복합형 질량댐퍼의 제어력 설계에 관한 연구)

  • Park, Jin-Il;Park, Hae-Dong;Choi, Hyun;Kim, Doo-Hoon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.276-281
    • /
    • 2000
  • As the construction of the high-rise building increases worldwide, the effort has been exerted to improve the safety and serviceability if the structure against various types of external dynamic loads such as wind load, seismic load, etc. The mass damper, defined as dynamic absorber in mechanical engineering is known one of the effective methods to control the vibration of flexible large structures. The hybrid mass damper, HMD is known as the most appropriate type of the mass dampers. In this paper, the control force was designed for HMD by numerical simulations and the performance of HMD to control the flexible vibration of the steel tower induced by sinusoidal force excitation was evaluated, also TMD was designed for a 1-DOF lumped mass model.

  • PDF

Optimum location for the belt truss system for minimum roof displacement of steel buildings subjected to critical excitation

  • Kamgar, Reza;Rahgozar, Peyman
    • Steel and Composite Structures
    • /
    • v.37 no.4
    • /
    • pp.463-479
    • /
    • 2020
  • Currently, there are many lateral resisting systems utilized in resisting lateral loads being produced in an earthquake. Such systems can significantly reduce the roof's displacement when placed at an optimum location. Since in the design of tall buildings, the minimum distance between adjacent buildings is important. In this paper, the critical excitation method is used to determine the best location of the belt truss system while calculating the minimum required distance between two adjacent buildings. For this purpose, the belt truss system is placed at a specific story. Then the critical earthquakes are computed so that the considered constraints are satisfied, and the value of roof displacement is maximized. This procedure is repeated for all stories; i.e., for each, a critical acceleration is computed. From this set of computed roof displacement values, the story with the least displacement is selected as the best location for the belt truss system. Numerical studies demonstrate that absolute roof displacements induced through critical accelerations range between 5.36 to 1.95 times of the San Fernando earthquake for the first example and 7.67 to 1.22 times of the San Fernando earthquake for the second example. This method can also be used to determine the minimum required distance between two adjacent buildings to eliminate the pounding effects. For this purpose, this value is computed based on different standard codes and compared with the results of the critical excitation method to show the ability of the proposed method.

A robust multi-objective localized outrigger layout assessment model under variable connecting control node and space deposition

  • Lee, Dongkyu;Lee, Jaehong;Kang, Joowon
    • Steel and Composite Structures
    • /
    • v.33 no.6
    • /
    • pp.767-776
    • /
    • 2019
  • In this article, a simple and robust multi-objective assessment method to control design angles and node positions connected among steel outrigger truss members is proposed to approve both structural safety and economical cost. For given outrigger member layouts, the present method utilizes general-purpose prototypes of outrigger members, having resistance to withstand lateral load effects directly applied to tall buildings, which conform to variable connecting node and design space deposition. Outrigger layouts are set into several initial design conditions of height to width of an arbitrary given design space, i.e., variable design space. And then they are assessed in terms of a proposed multi-objective function optimizing both minimal total displacement and material quantity subjected to design impact factor indicating the importance of objectives. To evaluate the proposed multi-objective function, an analysis model uses a modified Maxwell-Mohr method, and an optimization model is defined by a ground structure assuming arbitrary discrete straight members. It provides a new robust assessment model from a local design point of view, as it may produce specific optimal prototypes of outrigger layouts corresponding to arbitrary height and width ratio of design space. Numerical examples verify the validity and robustness of the present assessment method for controlling prototypes of outrigger truss members considering a multi-objective optimization achieving structural safety and material cost.

Normalised rotation capacity for deformability evaluation of high-performance concrete beams

  • Zhou, K.J.H.;Ho, J.C.M.;Su, R.K.L.
    • Earthquakes and Structures
    • /
    • v.1 no.3
    • /
    • pp.269-287
    • /
    • 2010
  • High-strength concrete (HSC) is becoming more popular in the construction of beams and columns of tall buildings because of its higher stiffness and strength-to-weight ratio. However, as HSC is more brittle than normal-strength concrete (NSC), it may adversely affect the flexural ductility and deformability of concrete members. Extended from a series of theoretical study conducted on flexural ductility of concrete beams, the authors would in this paper investigate the effects of some critical factors including the degree of reinforcement, confining pressure, concrete and steel yield strength on the flexural deformability of NSC and HSC beams. The deformability, expressed herein in terms of normalised rotation capacity defined as the product of ultimate curvature and effective depth, is investigated by a parametric study using nonlinear moment-curvature analysis. From the results, it is evident that the deformability of concrete beams increases as the degree of reinforcement decreases and/or confining pressure increases. However, the effects of concrete and steel yield strength are more complicated and dependent on other factors. Quantitative analysis of all these effects on deformability of beams has been carried out and formulas for direct deformability evaluation are developed. Lastly, the proposed formulas are compared with available test results to verify its applicability.

Preliminary Modelling of Plasco Tower Collapse

  • Yarlagadda, Tejeswar;Hajiloo, Hamzeh;Jiang, Liming;Green, Mark;Usmani, Asif
    • International Journal of High-Rise Buildings
    • /
    • v.7 no.4
    • /
    • pp.397-408
    • /
    • 2018
  • In a recent tragic fire incident, the Plasco Tower collapsed after an intense outburst of fire lasting for three and a half hours and claiming the lives of 16 firefighters and 6 civilians. This paper will present continuing collaborative work between Hong Kong Polytechnic University and Queen's University in Canada to model the progressive collapse of the tower. The fire started at the 10th floor and was observed to have travelled along the floor horizontally and through the staircase and windows vertically. Plasco Tower was steel structure and all the steel sections were fabricated by welding standard European channel or angle profiles and no fire protection was applied. Four internal columns carried the loads transferred by the primary beams, and box columns were constructed along the perimeter of the building as a braced tube for resisting seismic loading. OpenSees fibre-based sections and displacement-based beam-column elements are used to model the frames, while shell elements are used for the reinforced concrete floor slabs. The thermal properties and elevated temperature mechanical properties are as recommended in the Eurocodes. The results in this preliminarily analysis are based on rough estimations of the structure's configuration. The ongoing work looks at modeling the Plasco Tower based on the most accurate findings from reviewing many photographs and collected data.

Column Shortening Prediction of Concrete Filled Tubes using Monte Carlo Method (몬테카를로 기법을 이용한 CFT 기둥축소량의 예측)

  • Jang, Sung-Woo;Song, Hwa-Cheol;Sho, Kwang-Ho
    • Journal of Korean Association for Spatial Structures
    • /
    • v.10 no.1
    • /
    • pp.75-84
    • /
    • 2010
  • According to the available study and experimental data about the long term behavior of CFT(Concrete Filled Tube) columns, the creep and of concrete in CFT columns are smaller than those of RC columns because of the confinement effect of outer steel columns. In this study, the uncertainties associated with assumed values for concrete properties such as strength, creep coefficients, and service load have been considered and analyzed for the prediction of time-dependent column shortening of CFT column. The CFT column shortening analysis using Monte Carlo method is proposed and an of a 37 story tall building with CFT columns is studied for illustration. According to the results obtained by the probability analysis with multi parameters, the effect of variation coefficient for 3 parameters is investigated considering confidence interval.

  • PDF

A Study for Damping Application to Response-controlled Structure

  • Shinozaki, Yozo;Mogi, Yoshihiro;Ota, Masaaki;Yoshikawa, Hiroaki
    • International Journal of High-Rise Buildings
    • /
    • v.10 no.2
    • /
    • pp.149-164
    • /
    • 2021
  • Most of high-rise buildings in Japan*1 are structure with damping systems recently. The design procedure is performance-based design (PBD), which is based on the nonlinear response history procedure (NRHP) using 2 or 3-dimentional frame model. In addition, hysteretic property of steel plates or velocity-dependent property of viscous dampers are common practice for the damping system. However, for the selection of damping system, the easy dynamic analysis of recent date may lead the most of engineers to focus attention on the maximum response only without thinking how it shakes. By nature, the seismic design shall be to figure out the action of inertia forces by complex & dynamic loads including periodic and pulse-like characteristics, what we call seismic ground motion. And it shall be done under the dynamic condition. On the contrary, we engineers engineers have constructed the easy-to-use static loads and devoted ourselves to handle them. The structures with damping system shall be designed considering how the stiffness & damping to be applied to the structures against the inertia forces with the viewpoint of dynamic aspect. In this paper we reconsider the role of damping in vibration and give much thought to the basic of shake with damping from a standpoint of structural design. Then, we present some design examples based on them.

Damage Detection of Building Structures Using Ambient Vibration Measuresent (자연진동을 이용한 건물의 건전도 평가)

  • Kim, Sang Yun;Kwon, Dae Hong;Yoo, Suk Hyeong;Noh, Sam Young;Shin, Sung Woo
    • KIEAE Journal
    • /
    • v.7 no.4
    • /
    • pp.147-152
    • /
    • 2007
  • Numerous non-destructive tests(NDT) to assess the safety of real structures have been developed. System identification(SI) techniques using dynamic responses and behaviors of structural systems become an outstanding issue of researchers. However the conventional SI techniques are identified to be non-practical to the complex and tall buildings, due to limitation of the availability of an accurate data that is magnitude or location of external loads. In most SI approaches, the information on input loading and output responses must be known. In many cases, measuring the input information may take most of the resources, and it is very difficult to accurately measure the input information during actual vibrations of practical importance, e.g., earthquakes, winds, micro seismic tremors, and mechanical vibration. However, the desirability and application potential of SI to real structures could be highly improved if an algorithm is available that can estimate structural parameters based on the response data alone without the input information. Thus a technique to estimate structural properties of building without input measurement data and using limited response is essential in structural health monitoring. In this study, shaking table tests on three-story plane frame steel structures were performed. Out-put only model analysis on the measured data was performed, and the dynamic properties were inverse analyzed using least square method in time domain. In results damage detection was performed in each member level, which was performed at story level in conventional SI techniques of frequency domain.

Earthquake Response of Mid-rise to High-rise Buildings with Friction Dampers

  • Kaur, Naveet;Matsagar, V.A.;Nagpal, A.K.
    • International Journal of High-Rise Buildings
    • /
    • v.1 no.4
    • /
    • pp.311-332
    • /
    • 2012
  • Earthquake response of mid-rise to high-rise buildings provided with friction dampers is investigated. The steel buildings are modelled as shear-type structures and the investigation involved modelling of the structures of varying heights ranging from five storeys to twenty storeys, in steps of five storeys, subjected to real earthquake ground motions. Three basic types of structures considered in the study are: moment resisting frame (MRF), braced frame (BF), and friction damper frame (FDF). Mathematical modelling of the friction dampers involved simulation of the two distinct phases namely, the stick phase and the slip phase. Dynamic time history analyses are carried out to study the variation of the top floor acceleration, top floor displacement, storey shear, and base-shear. Further, energy plots are obtained to investigate the energy dissipation by the friction dampers. It is seen that substantial earthquake response reduction is achieved with the provision of the friction dampers in the mid-rise and high-rise buildings. The provision of the friction dampers always reduces the base-shear. It is also seen from the fast Fourier transform (FFT) of the top floor acceleration that there is substantial reduction in the peak response; however, the higher frequency content in the response has increased. For the structures considered, the top floor displacements are lesser in the FDF than in the MRF; however, the top floor displacements are marginally larger in the FDF than in the BF.