• Title/Summary/Keyword: system scale

Search Result 10,493, Processing Time 0.036 seconds

The Intelligent Monitoring System for a heavy weight scale (고 중량 측정 장치를 위한 지능형 모니터링 시스템)

  • 김영구;조현찬;정병우;김두용
    • Proceedings of the IEEK Conference
    • /
    • 2000.11c
    • /
    • pp.41-44
    • /
    • 2000
  • In this paper, we propose an Intelligent Monitoring Network System(IMNS) for The truck scale balance system. Truck scale balance system consis of three parts; Load cell part, Indicator part, and Junction box part. IMNS is attached to Junction box in truck scale balance system. Even if Load cell have been some problems, a truck scale balance system still has been run to determine, the values involved error. therefore prosed system is has concentrated on Load cell part. Other Parts have been changed a portion of circuit for monitoring system.

  • PDF

Analysis on Bus Voltage Sag in Power Distribution System with SFCL according to Interconnected Locations of Small DG (초전도 한류기 적용시 소형 분산전원시스템의 연계 위치에 따른 배전계통의 전압강하 분석)

  • Moon, Jong-Fil;Shon, Jin-Geun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.62 no.4
    • /
    • pp.210-215
    • /
    • 2013
  • This paper analyze the bus voltage sags in the power distribution system with a small scale cogeneration system when the superconducting fault current limiter was introduced. Among the solutions to decrease the short-circuit current considering the locations of the small scale cogeneration system, the superconducting fault current limiter (SFCL) has been announced as one of the promising methods to reduce the fault current because the installation of the small scale cogeneration system which increases the short-circuit current. According to the application locations of the small scale cogeneration system in a power distribution system, it has caused the variations of voltage sag and duration which depends on the change of the short-circuit current, which can make the operation of the protective device deviate from its original set value when the fault occurs. To investigate the voltage sag when a SFCL was applied into a power distribution system where the small scale cogeneration system was introduced into various locations, the SFCL, small scale cogeneration system, and power system are modeled using PSCAD/EMTDC. In this paper, the effects on voltage sags are assessed when the SFCL is installed in power distribution system with various locations of the small scale cogeneration system.

Design of sub-optimal regulators for the large-scale stochastic system with time-scale separation properties (여러 시간스케일로 분리 가능한 대규모 스토캐스틱 시스템의 준 최적 조정기의 설계)

  • 이종효;전기준
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1986.10a
    • /
    • pp.550-553
    • /
    • 1986
  • This paper presents a procedure for the time-scale separation and a design method for the sub-optimal composite regulator and Kalman filter of the large-scale discrete stochastic system with two time-scale properties. Provided that the fast sub-system is asymptotically stable, the reduced-order regulator and Kalman filter for the slow sub-system with dominant modes is designed as a sub-optimal regulator for the system.

  • PDF

The Configurations of the large scale UPS system (대규모 무정전 전원공급 시스템의 구성방안)

  • 송언빈;윤병도
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1991.10a
    • /
    • pp.80-83
    • /
    • 1991
  • The need of UPS (Uninterruptible Power Sup-ply) system is dramatically increasing with the increased use of computers, telecommunica-tion system, building automation system, and office automation system in office buildings. The consequence of the power failure is very disas trous in intelligent office buil-dings. Thus, the nucessity of large scale UPS system with generations of large scale UPS system with generator is increasing. In this study, the configurations of large scale UPS system are reviewed and analyzed. The design guide and technical considerations of high reliability system are presented.

  • PDF

Intelligent Monitoring Network System (지능형 모니터링 네트웍 시스템 구성에 관한 연구)

  • 김영구;조현찬;김두용;전홍태
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2000.11a
    • /
    • pp.393-398
    • /
    • 2000
  • In this paper, we propose an Intelligent Monitoring Network System(IMNS) for the truck scale balance system. Truck scale balance system consis of three parts; Load cell part, Indicator part, and Junction box part. IMNS is attached to Junction box in truck scale balance system. Even if Load cell have been some problems, a truck scale balance system still has been run to determine, the values involved error. Therefore prosed system is has concentrated on Load cell part. Other Parts have been changed a portion of circuit for monitoring system.

  • PDF

Small Scale Map Projection and Coordinate System Improvement in Consideration of Usability and Compatibility

  • Choi, Byoung Gil;Na, Young Woo;Jung, Jin Woo
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.34 no.2
    • /
    • pp.171-183
    • /
    • 2016
  • Small-scale maps currently used are made by scanning and editing printed maps and its shortcoming is accumulated errors at the time of editing and low accuracy. TM projection method is used but its accuracy varies. In addition, small-scale maps are made without consideration of usability and compatibility with other scale maps. Therefore, it is necessary to suggest projection and coordinates system improvement methods in consideration of usability and compatibility between data. The results of this study reveal that in order to make the optimum small-scale map, projection that fits the purpose of map usage in each scale, coordinate system and neat line composition should be selected in consideration of interrelation and compatibility with other maps. Conic projection should be used to accurately illustrate the entire country, but considering usability and compatibility with other maps, traversing cylindrical projection should be used instead of conic projection. For coordinates system of the small-scale map, Universal Transverse Mercator (UTM-K) based on the World Geodetic System should be used instead of conventional longitude and latitude coordinate system or Transverse Mercator.

A Study on the Ancient Scale of Measurement Unit Employed in Buildings and Their Sites -Focused on the East and West buildings and their sites of 'Kum-dang' in 'Mi-ruk Sa' temple- (고대(古代) 건물지(建物址)의 조영척도(造營尺度)에 관한 고찰(考察) -미륵사 동.서 금당지를 중심으로-)

  • Kim, Young-Phil;Lee, Sang-Sun;Lee, Bong-Soo;Chang, Dong-Kuk;Park, Kang-Chul
    • Journal of architectural history
    • /
    • v.16 no.4
    • /
    • pp.95-110
    • /
    • 2007
  • In spite of the increasing significance on a scale of building measurement unit and its system having been used in many areas of architecture, only a few researchers carried out the studies on a specific period. It is even harder to find a research results dealt in view of architecture. This research gives a focus on different types of scales employed in the ancient buildings and their sites, based on the research results of unit scale or scales found in recent excavations. After the review of literature on the scales widely used in the ancient times and of the various types of scales excavated archeologically, a kind of scale unit system that had been widely and extensively employed throughout the period of 'Three Kingdoms' could be revealed. The scale system is possibly able to be applied to estimate the exact scale of buildings and their sites as well in that era. The research results show that the scale and its system employed in the East and West buildings and their sites of 'Kum-dang' in 'Mi-ruk Sa' temple are different from 'Kokuryo' scale that was believed in to be used in the temple. Contrary to the suggestion by excavation report on the type of scale employed in the buildings their sites, a scale of 29 centimeters, similar to that of Tang, was employed. It was also found that one module consists of three 'Chuk's of 88.8 centimeters. Based on this scale system, we could conclude that three modules of the buildings on the front and two and half modules of them on the sides were explained by this scale and its system.

  • PDF

A study of facial nerve grading system (구안와사(口眼喎斜)의 평가방법(評價方法)에 대한 고찰(考察))

  • Kim, Jong-In;Koh, Hyung-Kyun;Kim, Chang-Hwan
    • Journal of Acupuncture Research
    • /
    • v.18 no.2
    • /
    • pp.1-17
    • /
    • 2001
  • Background and Objetive : Lack of uniformity in reporting facial nerve recovery in patients with facial nerve paralysis has been a major disadvantage in comparing treatment modalities. The objective evaluation of facial nerve function is a complex procedure. The House and Brackmann grading system, the Yanagihara grading system has been recommend as a universal standard for assessing the degree of facial nerve palsy. However, clinical studies for treatment of facial palsy have rarely used this universal standard in oriental medicine. That is the reason for analysing this facial nerve grading system. Material and Method : We choose 10 scales reported from 1955 till 1995. These facial nerve grading systems may be classified as Gross system, Regional system and Specific system. Result and Conculsion : The scales of Botmann and Jonkees, May, Peitersen, and House and Brackmann are the gross facial nerve grading systems with which we grossly assess the facial motor dysfunction and the secondary defect. Among these scales, H-B scale is the most widespred The scales of Yanagihara(若杉文吉), Smith, Adour and Swanson, Jassen, FEMA are the regional facial nerve grading system in which we weight, or unweight the facial motor dysfunction and the secondary defect. For example, the scales of Yanagihara(若杉文吉) and Smith are the unweighted regional scale, the scale of Adour and Swanson, Jassen, FEMA are the weighted regional grading system. The scale of Stennert is the Specific facial nerve grading system in which we respectively assess the grade of facial dysfunction at rest, in motion and the secondary defect. For the objective evaluation of the oriental medicine treatment for facial palsy, we must use the universal standard scale, i.e. the H-B scale, the Yanagihara scale.

  • PDF

Analysis on Recloser-Fuse Coordination in a Power Distribution System linked Small Scale Cogeneration System with Superconducting Fault Current Limiter (소형 열병합발전 시스템이 연계된 배전계통에 초전도 전류제한기 적용시 리클로져-퓨즈 협조 분석)

  • Kim, Myoung-Hoo;Kim, Jin-Seok;Moon, Jong-Fil;Lim, Sung-Hun;Kim, Jae-Chul;Lee, Joon-Kyu
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.3
    • /
    • pp.499-505
    • /
    • 2010
  • This paper analyzed that the coordination of recloser-fuse when a superconducting fault current limiter (SFCL) is installed to a power distribution system linked small scale cogeneration system. As a rule, the recloser to properly protect against both permanent and temporary fault is installed to upstream of fuse. Therefore, in a power distribution system linked small scale cogeneration system, the fault current is increased by adding fault current of small scale Cogeneration system when a permanent fault occurs, and the fuse could melt during the first fast operation of the recloser because of more sufficient heat from the increased current. However, when SFCLs are applied into a power distribution system linked small scale cogeneration system, the coordination of recloser-fuse could be accomplished due to decreased fault current as the effect of the impedance value of the SFCL. Therefore, to solve these problems, we analysed the operation of recloser-fuse coordination in a power distribution system linked small scale cogeneration system with SFCL using PSCAD/EMTDC.

A Study on Measurement System Accuracy of Theodolite System(IV) - A Measurement System Accuracy depending on a Distance of Scale Bar on the Distance 4m between two Theodolites (데오드라이트 시스템의 측정 정확도에 대한 연구(IV) - 시준거리 4m에서의 기준자 거리에 따른 측정 정도)

  • Yoon Yong-Sik;Lee Dong-Ju;Park Yo-Chang
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.14 no.3
    • /
    • pp.67-73
    • /
    • 2005
  • An accuracy of theodolite system may be affected by a measurement environment and a measurement distance change from theodolite to scale bar and/or targets. This study was performed for measuring an accuracy when the distance from thodolite system to scale bar was changed $2\~6m$ on the distance 4m between two theodolites. The results showed that an accuracy was ${\pm}0.025mm$ or better when the distance from theodolite system to targets was 3, 4 and 5m. According to the results, it was found that the best distance from theodolite system to scale bar was $3\~4m$ when the collimation distance was $3\~4m$.