• 제목/요약/키워드: synthetic high polymers

검색결과 49건 처리시간 0.027초

Quantum-chemical Study of Effects of Alkoxy Substitution on the Conformations and Electronic Properties of Poly(p-phenylenevinylenes)

  • Hong, Sung Y.
    • Bulletin of the Korean Chemical Society
    • /
    • 제20권1호
    • /
    • pp.42-48
    • /
    • 1999
  • We have performed a quantum-chemical investigation on the conformations and electronic properties of a variety of methoxy-substituted poly(p-phenylenevinylenes) (PPVs) to elucidate the effects of alkoxy substitution. Geometrical parameters for the polymers were fully optimized through Austin Model I (AM I) semi-empirical Hartree-Fock (HF) band calculations. Electronic properties of the polymers were obtained by applying the AM I optimized structures to the modified extended Huckel method. To confirm validity of the AM I conformational results, we also carried out ab initio HF calculations with the 6-31G (d) basis set for a variety of methoxy-substituted divinylbenzenes. It is found that the potential energy surfaces of alkoxy-substituted PPVs are quite shallow around the planar conformations, suggesting that the prepared films possess a variety of conformations with different torsion angle in the solid state, depending on the synthetic conditions. When two alkoxy groups are concurrently substituted at the adjacent sites in the phenylene ring, these groups are subject to rotating around the C(sp2)-O bonds by 70-80° to avoid the strong steric repulsion between them. Consequently, the overlap between the π-type p orbital of oxygen and the π molecular orbitals of the polymer decreases. This leads to a wide gap and a high oxidation potential for tetramethoxy-substituted PPV, compared to those of dialkoxy-substituted PPV.

Characterization of jute fibre reinforced pine rosin modified soy protein isolate green composites

  • Sakhare, Karishma M.;Borkar, Shashikant P.
    • Advances in materials Research
    • /
    • 제11권3호
    • /
    • pp.191-209
    • /
    • 2022
  • Very slow degradation of synthetic based polymers has created a severe environmental issue that increased awareness towards research in polymers of biodegradable property. Soy protein isolate (SPI) is a natural biopolymer used as matrix in green composites but it has limitations of low mechanical properties and high water sensitivity. To enhance mechanical properties and reduce water sensitivity of Jute-SPI composites, SPI was modified with pine rosin which is also a natural cross-linking agent. 30% glycerol on the weight basis of a matrix was used as a plasticizer. The fibre volume fraction was kept constant at 0.2 whereas the pine rosin in SPI ranged from 5% to 30% of the matrix. The effects of pine rosin on mechanical, thermal, water sensitivity and surface morphology have been characterized using various techniques. The mechanical properties and water absorbency were found to be optimum for 15% pine rosin in Jute-SPI composite. Therefore, Jute-SPI composite without pine rosin and with 15% pine rosin were chosen for investigation through characterization by Fourier transforms infrared spectroscopy (FTIR), Thermo-gravimetric analysis (TGA), X-Ray diffraction (XRD) and Scanning electron microscope (SEM). The surface morphology of the composite was influenced by pine rosin which is shown in the SEM image. TGA measurement showed that the thermal properties improved due to the addition of pine rosin. Antimicrobial test showed antimicrobial property in the composite occurring 15% pine rosin. The research paper concludes that the modification of SPI resin with an optimum percentage of pine rosin enhanced mechanical, thermal as well as water-resistant properties of jute fibre reinforced composites.

keV and MeV Ion Beam Modification of Polyimide Films

  • Lee, Yeonhee;Seunghee Han;Song, Jong-Han;Hyuneui Lim;Moojin Suh
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2000년도 제18회 학술발표회 논문개요집
    • /
    • pp.170-170
    • /
    • 2000
  • Synthetic polymers such as polyimide, polycarbonate, and poly(methyl methacrylate) are long chain molecules which consist of carbon, hydrogen, and heteroatom linked together chemically. Recently, polymer surface can be modified by using a high energy ion beam process. High energy ions are introduced into polymer structure with high velocity and provide a high degree of chemical bonding between molecular chains. In high energy beam process the modified polymers have the highly crosslinked three-dimensionally connected rigid network structure and they showed significant improvements in electrical conductivity, in hardness and in resistance to wear and chemicals. Polyimide films (Kapton, types HN) with thickness of 50~100${\mu}{\textrm}{m}$ were used for investigations. They were treated with two different surface modification techniques: Plasma Source Ion Implantation (PSII) and conventional Ion Implantation. Polyimide films were implanted with different ion species such as Ar+, N+, C+, He+, and O+ with dose from 1 x 1015 to 1 x 1017 ions/cm2. Ion energy was varied from 10keV to 60keV for PSII experiment. Polyimide samples were also implanted with 1 MeV hydrogen, oxygen, nitrogen ions with a dose of 1x1015ions/cm2. This work provides the possibility for inducing conductivity in polyimide films by ion beam bombardment in the keloelectronvolt to megaelectronvolt energy range. The electrical properties of implanted polyimide were determined by four-point probe measurement. Depending on ion energy, doses, and ion type, the surface resistivity of the film is reduced by several orders of magnitude. Ion bombarded layers were characterized by Time-of-Flight Secondary Ion Mass Spectrometry (TOF-SIMS), XPS, and SEM.

  • PDF

삼투압을 이용한 중공사막 흐름장 흐름 분획법에 의한 콜로이드 입자의 분리 (Separation of Colloidal Particles by Holow Fiber Flow Field Flow Fractionation Using Osmotic Sink)

  • 신세종;이원주;전용한;이경현;민병렬
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 1998년도 춘계 총회 및 학술발표회
    • /
    • pp.110-112
    • /
    • 1998
  • 1. 서론 : 분석화학의 중요한 과제중 하나 고효율(high efficiency)과 고해상도(high resolution)를 가지고서 혼합물에서 분자나 입자의 분리능을 개선하는 것과 낮은 수준의 농도에서 이런 분획들(fractions)을 정량화 하는 것이다. 현재의 추세는 분리하고자 하는 분자의 상한선을 증가시키는 것이 순수과학과 산업에서 중요하게 되었다. 이런 분리 기술의 응용은 거대분자(macromolecules)와 입자들(particles)인 cell fragments, plasmides, chromosomes, liposomes, synthetic polymers 등에 적용되고 있는데, 고전적인 분석방법으로는 한외여과, 원심분리, 크기배제 크로마토그래피 등이 있지만 시간이 걸리고 해상도와 효율에 제한이 있다.

  • PDF

Local Drug Delivery System Using Biodegradable Polymers

  • Khang, Gil-Son;Rhee, John M.;Jeong, Je-Kyo;Lee, Jeong-Sik;Kim, Moon-Suk;Cho, Sun-Hang;Lee, Hai-Bang
    • Macromolecular Research
    • /
    • 제11권4호
    • /
    • pp.207-223
    • /
    • 2003
  • For last five years, we are developing the novel local drug delivery devices using biodegradable polymers, especially polylactide (PLA) and poly(D,L-lactide-co-glycolide) (PLGA) due to its relatively good biocompatibility, easily controlled biodegradability, good processability and only FDA approved synthetic degradable polymers. The relationship between various kinds of drug [water soluble small molecule drugs: gentamicin sulfate (GS), fentanyl citrate (FC), BCNU, azidothymidine (AZT), pamidronate (ADP), $1,25(OH)_2$ vitamin $D_3$, water insoluble small molecule drugs: fentanyl, ipriflavone (IP) and nifedipine, and water soluble large peptide molecule drug: nerve growth factor (NGF), and Japanese encephalitis virus (JEV)], different types of geometrical devices [microspheres (MSs), microcapsule, nanoparticle, wafers, pellet, beads, multiple-layered beads, implants, fiber, scaffolds, and films], and pharmacological activity are proposed and discussed for the application of pharmaceutics and tissue engineering. Also, local drug delivery devices proposed in this work are introduced in view of preparation method, drug release behavior, biocompatibility, pharmacological effect, and animal studies. In conclusion, we can control the drug release profiles varying with the preparation, formulation and geometrical parameters. Moreover, any types of drug were successfully applicable to achieve linear sustained release from short period ($1{\sim}3$ days) to long period (over 2 months). It is very important to design a suitable formulation for the wanting period of bioactive molecules loaded in biodegradable polymers for the local delivery of drug. The drug release is affected by many factors such as hydrophilicity of drug, electric charge of drug, drug loading amount, polymer molecular weight, the monomer composition, the size of implants, the applied fabrication techniques, and so on. It is well known that the commercialization of new drug needs a lot of cost of money (average: over 10 million US dollar per one drug) and time (average: above 9 years) whereas the development of DDS and high effective generic drug might be need relatively low investment with a short time period. Also, one core technology of DDS can be applicable to many drugs for the market needs. From these reasons, the DDS research on potent generic drugs might be suitable for less risk and high return.

이산화티탄 나노입자 필러가 PET와 PLA 나노복합체의 특성에 미치는 영향 (Influence of TiO2 Nanoparticle Filler on the Properties of PET and PLA Nanocomposites)

  • Farhoodi, Mehdi;Dadashi, Saeed;Mousavi, Seyed Mohammad Ali;Sotudeh-Gharebagh, Rahmat;Emam-Djomeh, Zahra;Oromiehie, Abdolrasul;Hemmati, Farkhondeh
    • 폴리머
    • /
    • 제36권6호
    • /
    • pp.745-755
    • /
    • 2012
  • Two types of polymers were tested in this study; poly(ethylene terephthalate) (PET) as a synthetic example and poly(lactic acid) (PLA) as a natural polymer. DSC analyses showed that the use of nanofiller increased the degree of crystallinity ($X_c$) of both PET and PLA polymers, but the effect was more noticeable on PET nanocomposites. The crystallization of PLA and PET nanocomposites occurred at higher temperatures in comparison to neat polymers. According to dynamic mechanical-thermal analysis (DMTA), the damping factor of PET/$TiO_2$ nanoparticles decreased compared to the neat matrix, but for PLA nanocomposites the opposite trend was observed. Results of the mechanical test showed that for both PET and PLA nanocomposites, the most successful toughening effect was observed at 3 wt% loading of $TiO_2$ nanoparticles. SEM micrographs revealed uniform distribution of $TiO_2$ nanoparticles at 1 and 3 wt% loading levels. The results of WAXD spectra explained that the polymorphs of PLA and PET was not affected by $TiO_2$ nanoparticles. UV-visible spectra showed that $TiO_2$ nanocomposite films had high ultraviolet shielding compared to neat polymer, but there was significant reduction in transparency.

Preparation of the activated carbon for the canister form cokes

  • In-Ki, Kim;Han-Jun, Oh;Jang, Jin-Seok;Youm, Hee-Nam;Young-Shin, Ko
    • 한국결정성장학회:학술대회논문집
    • /
    • 한국결정성장학회 1997년도 Proceedings of the 12th KACG Technical Meeting and the 4th Korea-Japan EMGS (Electronic Materials Growth Symposium)
    • /
    • pp.67-71
    • /
    • 1997
  • Activated carbons are the microporous carbonaceous adsorbents which are prepared from carbon-containing source materials such as wood, coal, lignite, peteroleum and sometimes synthetic high polymers. [1-2] Activated carbons shows an ability to adsorbe hydrocarbons of the gas phase. Activated carbons are used in the purification of many kinds of gas phases like hexane, benzene, toluene, gasoline, phenol etc.[3] In this study, cokes from bitminous coal were activated for the purpose of preparing the activated carbons by steam activation. The effect of the activation temperature, time, steam concentration and flow rate on the n-butane adsorption, burn off, surface area and average pore size of the activated carbons, were investigated. The adsorption characteristics of the activated carbons for gasoline are indirectly estimated by n-butane adsorption.

  • PDF

Membranes for the Guided Bone Regeneration

  • Lee, Sang-Woon;Kim, Seong-Gon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제36권6호
    • /
    • pp.239-246
    • /
    • 2014
  • Many kinds of membrane have been used for the guided bone regeneration (GBR) technique. However, most membranes do not fulfill all requirements for the ideal membrane for the GBR technique. Among them, collagen membrane has been most widely used. However, its high price and weak tensile strength in wet condition are limitations for wide clinical application. Synthetic polymers have also been used for the GBR technique. Recently, silk based membrane has been considered as a membrane for the GBR technique. Despite many promising preclinical data for use of a silk membrane, clinical data regarding the silk membrane has been limited. However, silk based material has been used clinically as vessel-tie material and an electrospun silk membrane was applied successfully to patients. No adverse effect related to the silk suture has been reported. Considering that silk membrane can be provided to patients at a cheap price, its clinical application should be encouraged.

Biodistribution and Hemolysis Study of Terplex Gene Delivery System in Mice

  • Oh, Eun-Jung;Shim, Jin-young;Kim, Jin-Seok
    • Macromolecular Research
    • /
    • 제11권1호
    • /
    • pp.19-24
    • /
    • 2003
  • Polymeric gene delivery system attracts profound attention as it shows less toxicity, versatility, and reasonable gene expression efficiency. Terplex system, a synthetic biopolymeric gene delivery system consisting of stearyl poly-L-lysine (stearyl-PLL) and low density lipoprotein (LDL) was evaluated for its body distribution of gene expression of exogenously administered pDNA after tail-vein injection in mice. Kidney and spleen are two major organs with highest gene expression, whereas liver and heart showed marginal gene expression among the organs examined. Hemolytic effect of the terplex system was evaluated using human red blood cells, where terplex system did not cause significant hemolysis at the concentrations above the experimental ranges, although unmodified PLL or stearyl-PLL without LDL did. Serum stability of terplex system against enzymatic degradation was also significantly enhanced, presumably due to the steric stabilization from the polymers. Based on these findings and along with its high in vitro transfection efficiency, terplex system could serve as a safe and efficient polymeric gene delivery system with many applications for the in vivo gene therapy.

식품포장재내 비휘발성 잠재 이행물질들의 스크리닝을 위한 이차원크로마토 그래피와 범용검출기의 이용 (The Use of the Online Two-dimensional Liquid Chromatography Coupled with a Universal Detector for the Screening of Non-volatile Potential Migrants in Food Packaging Materials)

  • 윤찬석;이근택
    • 한국포장학회지
    • /
    • 제16권1호
    • /
    • pp.9-18
    • /
    • 2010
  • For screening test of the non-volatile compounds which migrate from food packaging materials into foodstuffs, the traditional high performance liquid chromatography (HPLC) systems suffer from the lack of universal detector with high sensitivity and universality and high efficiency HPLC separation column which provides complete separation of complex mixtures into all individual substances. In this work, the use possibility of online two-dimensional liquid chromatography (2D-LC) system coupled with a charged aerosol detector (CAD), a universal detector, was reviewed. 2D-LC system permits to improve peak capacity and resolving power for complex mixtures. Charged aerosol detector (CAD) offers a new feasibility for detection of any non-volatile compounds with high sensitivity and constant response factor in a calibration range. The combination of size exclusion chromatography (SEC) and normal phase HPLC (NP-HPLC) is most frequently used for the separation of the natural and synthetic polymers which are mainly used as raw materials for the manufacture of food packaging materials. However, there is no commercial software available for data acquisition and handling and therefore the quantification in 2D-LC analysis is still rare.

  • PDF