• Title/Summary/Keyword: switching sequence

Search Result 146, Processing Time 0.027 seconds

A Generalized Space Vector Modulation Scheme Based on a Switch Matrix for Cascaded H-Bridge Multilevel Inverters

  • K.J., Pratheesh;G., Jagadanand;Ramchand, Rijil
    • Journal of Power Electronics
    • /
    • v.18 no.2
    • /
    • pp.522-532
    • /
    • 2018
  • The cascaded H Bridge (CHB) multilevel inverter (MLI) is popular among the classical MLI topologies due to its modularity and reliability. Although space vector modulation (SVM) is the most suitable modulation scheme for MLIs, it has not been used widely in industry due to the higher complexity involved in its implementation. In this paper, a simple and novel generalized SVM algorithm is proposed, which has both reduced time and space complexity. The proposed SVM involves the generalization of both the duty cycle calculation and switching sequence generation for any n-level inverter. In order to generate the gate pulses for an inverter, a generalized switch matrix (SM) for the CHB inverter is also introduced, which further simplifies the algorithm. The algorithm is tested and verified for three-phase, three-level and five-level CHB inverters in simulations and hardware implementation. A comparison of the proposed method with existing SVM schemes shows the superiority of the proposed scheme.

Development of a Half-Duplex Communication Device for Use via Human Skin (인체 임피던스를 이용한 양방향 통신 시스템의 설계)

  • Kim, Won-Jun;Song, Kyo-Yong;Kim, Young-Pil;Ko, Dong-Young;Kim, Jung-Han
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.24 no.5
    • /
    • pp.583-587
    • /
    • 2015
  • In this study, a half-duplex mutual communication device via human skin was developed. Frequency-shift keying (FSK) digital modulation and demodulation control were used to transmit and receive data. Data communication through the human body is an effective communication technique and has high-grade security characteristics. In addition, making contact is a natural instinct of humans. Transmitting data through the human body is currently a highly conspicuous technology, because recently a lot of commercial sensors for humans have been developed. A body area network (BAN) can be easily constructed by this communication method on human skin. In this study, a half-duplex FSK mutual communication device was developed using a commercial FSK modulator and demodulator. A special control switching circuit and communication sequence were developed for mutual communication through human skin.

Development of Propulsion System for Korean High Speed Railway (한국형 고속전철용 추진제어장치 개발)

  • Lee K.J.;Cho S.J.;Woo M.H.;Jang S.Y.;Kim D.S.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.872-875
    • /
    • 2003
  • This paper introduces the propulsion system for Korean High Speed Railway(HSR). The developed propulsion system consists of PWM AC/DC converter and inverter. Compared with TGV-K, converters can improve input harmonics characteristics by the interlaced PW switching methods. And several merits such as unity power factor and simple regenerative operations can be also made. As a main power component, IGCT stack with suitable structure for high speed train and environmentally friendly cooling heat pipe is designed. In this paper, overall configuration of controller and control scheme is briefly described. Finally running tests are made to verify the developed propulsion system. The presented test results shows fast torque response, balanced converter current sharing, and appropriate running sequence.

  • PDF

A CMOS 5.4/3.24-Gbps Dual-Rate CDR with Enhanced Quarter-Rate Linear Phase Detector

  • Yoo, Jae-Wook;Kim, Tae-Ho;Kim, Dong-Kyun;Kang, Jin-Ku
    • ETRI Journal
    • /
    • v.33 no.5
    • /
    • pp.752-758
    • /
    • 2011
  • This paper presents a clock and data recovery circuit that supports dual data rates of 5.4 Gbps and 3.24 Gbps for DisplayPort v1.2 sink device. A quarter-rate linear phase detector (PD) is used in order to mitigate high speed circuit design effort. The proposed linear PD results in better jitter performance by increasing up and down pulse widths of the PD and removes dead-zone problem of charge pump circuit. A voltage-controlled oscillator is designed with a 'Mode' switching control for frequency selection. The measured RMS jitter of recovered clock signal is 2.92 ps, and the peak-to-peak jitter is 24.89 ps under $2^{31}-1$ bit-long pseudo-random bit sequence at the bitrate of 5.4 Gbps. The chip area is 1.0 mm${\times}$1.3 mm, and the power consumption is 117 mW from a 1.8 V supply using 0.18 ${\mu}m$ CMOS process.

Space Vector PWM Technique for Two-Phase Inverter-Fed Two-Phase Induction Motors (2상 유도전동기의 구동을 위한 2상 인버터의 2상 공간전압벡터 PWM 방식)

  • 장도현;윤덕용
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.7 no.1
    • /
    • pp.1-10
    • /
    • 2002
  • In this paper the space voltage vector pulsewidth modulation(SVPWM) technique for two-phase inverter is proposed. The two-phase SVPWM technique is applicable to two-phase induction motor drives. The two-phase inverter using two-phase SVPWM technique cannot generate zero voltage vectors, but four space vectors. A reference voltage vector in the square locus is realized by adjusting four space vectors. The switching sequence "two-phase symmetrical modulation" used in two-phase SVPWM is proposed. Practical verification of theoretical predictions is presented to conform the capabilities of the new technique.technique.

A Restoration Automation Algorithm on a Fault in Substation of SCADA-coordinated Distribution Automation System (SCADA가 통합된 배전자동화 시스템의 변전소 사고 시 복구 자동화 알고리즘)

  • Hong, Jun-Ho;Lim, Il-Hyung;Lee, Seung-Jae;Kim, Tae-Wan;Choi, Myeon-Song;Ha, Bok-Nam;Lee, Sung-Woo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.11
    • /
    • pp.2107-2114
    • /
    • 2009
  • It is impossible to take the instant action in the distribution system When fault occures in a substation because operation of the substation and the distribution system are separated. However the power system automation has been studying about unity operation and co-operation between SCADA and DAS(Distribution Automation System). In this paper proposes a new algorithm of efficiency restoration using a outage load switching to a healthy MTR a fault occurrence at a MTR in united system between DAS and SCADA. In addtion, proposed algorithm includes a outage restoration method which keeps MTR optimal capacity with reorganization of distribution network in case it can not restore outage state loads caused by shortage of healthy MTR remain capacity. In case that proposed sequence still can not complete restoration, this paper suggests a efficiency outage restoration with objective function included priority in outage loads. In the case studies, the proposed algorithm have been verified in 2 MTR and 3 MTR substation

Transient-Performance-Oriented Discrete-Time Design of Resonant Controller for Three-Phase Grid-Connected Converters

  • Song, Zhanfeng;Yu, Yun;Wang, Yaqi;Ma, Xiaohui
    • Journal of Power Electronics
    • /
    • v.19 no.4
    • /
    • pp.1000-1010
    • /
    • 2019
  • The use of internal-model-based linear controller, such as resonant controller, is a well-established technique for the current control of grid-connected systems. Attractive properties for resonant controllers include their two-sequence tracking ability, the simple control structure, and the reduced computational burden. However, in the case of continuous-designed resonant controller, the transient performance is inevitably degraded at a low switching frequency. Moreover, available design methods for resonant controller is not able to realize the direct design of transient performances, and the anticipated transient performance is mainly achieved through trial and error. To address these problems, the zero-order-hold (ZOH) characteristic and inherent time delay in digital control systems are considered comprehensively in the design, and a corresponding hold-equivalent discrete model of the grid-connected converter is then established. The relationship between the placement of closed-loop poles and the corresponding transient performance is comprehensively investigated to realize the direct mapping relationship between the control gain and the transient response time. For the benefit of automatic tuning and real-time adaption, analytical expressions for controller gains are derived in detail using the required transient response time and system parameters. Simulation and experimental results demonstrate the validity of the proposed method.

Optimal Two Degrees-of-Freedom Based Neutral Point Potential Control for Three-Level Neutral Point Clamped Converters

  • Guan, Bo;Doki, Shinji
    • Journal of Power Electronics
    • /
    • v.19 no.1
    • /
    • pp.119-133
    • /
    • 2019
  • Although the dual modulation wave method can solve the low-frequency neutral point potential (NPP) fluctuation problem for three-level neutral point clamped converters, it also increases the switching frequency and limits the zero-sequence voltage. That makes it harmful when dealing with the NPP drift problem if the converter suffers from a long dead time or asymmetric loads. By introducing two degrees of freedom (2-DOF), an NPP control based on a search optimization method can demonstrate its ability to cope with the above mentioned two types of NPP problems. However, the amount of calculations for obtaining an optimal 2-DOF is so large that the method cannot be applied to certain industrial applications with an inexpensive digital signal processor. In this paper, a novel optimal 2-DOF-based NPP control is proposed. The relationships between the NPP and the 2-DOF are analyzed and a method for directly determining the optimal 2-DOF is also discussed. Using a direct calculation method, the amount of calculations is significantly reduced. In addition, the proposed method is able to maintain the strongest control ability for the two types of NPP problems. Finally, some experimental results are given to confirm the validity and feasibility of the proposed method.

Highly ordered TiO2 nanotubes; Synthesis and applications (고도로 정렬된 TiO2 나노튜브의 제조와 활용)

  • Yoo, JeongEun;Lee, Kiyoung
    • Journal of the Korean institute of surface engineering
    • /
    • v.55 no.1
    • /
    • pp.1-8
    • /
    • 2022
  • Titanium dioxide (TiO2) is one of the most intensively investigated materials in materials science. Mostly, TiO2 has been used in the form of nanoparticles, but recently new highly ordered TiO2 nanotubes (U-tube) has been introduced and applied to various applications due to their one-dimensional charge path way. In the present paper, we described the formation process and physical properties of U-tube then, gave examples of applications in sequence. Firstly, in photocatalysis, U-tube was used with Au/Pt co-catalysts and showed enhanced photogenerated H2 efficiency compared to bare TiO2. Secondly, photoelectrochemical performance of U-tube was evaluated with different heat-treatment temperatures. As a further application, two different types of electrical cell (Ti-TiO2-Pt and Ti-TiO2-PtNP) was configurated to observe memristive behavior of U-tube. Both cells behaved as switching electrodes and follow a memristive movement in the high and low resistance state extremely well with high reproducibility.

Bioequivalence of Stapin ER Tablet to Splendil ER Tablet (Felodipine 5 mg) (스프렌딜 지속정(펠로디핀 5 mg)에 대한 스타핀 지속정의 생물학적동등성)

  • Cho, Hea-Young;Kang, Hyun-Ah;Lee, Suk;Baek, Seung-Hee;Park, Eun-Ja;Choi, Hoo-Kyun;Moon, Jai-Dong;Lee, Yong-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • v.33 no.4
    • /
    • pp.311-317
    • /
    • 2003
  • Felodipine is a calcium antagonist that lowers blood pressure by reducing peripheral resistance by meas of a direct, selective action on smooth muscle in arterial resistance vessels. Futhermore, it have been approved for the effective in angina pectoris and cardiac failure. The purpose of the present study was to evaluate the bioequivalence of two felodipine extended release (ER) tablets, Splendil (YuHan Corporation) and Stapin (Hana Pharmaceutial Co., Ltd.), according to the guidelines of Korea Food and Drug Administration (KFDA). The felodipine release from the two felodipine formulations in vitro was tested using KP VIII Apparatus II method at pH 6.5 buffer solution. Twenty six healthy male subjects, $22.73{\pm}1.78$ years in age and $66.66{\pm}7.28\;kg$ in body weight, were divided into two groups and a radomized $2{\times}2$ cross-over study was employed. After two tablets containing 5 mg as felodipine were orally administered, blood sample was taken at predetermined time intervals and the concentrations of felodipine in serum were determined using column-switching HPLC method with UV detector. The dissolution profiles of two formulations were similar at pH 6.5 buffer solution. Besides, the pharmacokinetic parameters such as $AUC_t,\;C_{max}\;and\;T_{max}$ were calculated and ANOVA test was utilized for the statistical analysis of the parameters using logarithmically transformed $AUC_t\;and\;C_{max}$ and untransformed $T_{max}$. The results showed that the differences between two formulations based on the Splendil were 2.53%, 1.32% and 18.32% for $AUC_t,\;C_{max}\;and\;T_{max}$, respectively. There were no sequence effects between two formulations in these parameters. The 90% confidence intervals using logarithmically transformed data were within the acceptance rage of log(0.86) to log(1.25) $(e.g.,\;log(0.86){\sim}log(1.20)\;and\;log(0.89){\sim}log(1.23)\;for\;AUC_t,\;C_{max},\;respectively)$. Thus, the criteria of the KFDA guidelines for the bioequivalence was satisfied, indicating Stapin ER tablet and Splendil ER tablet are bioequivalent.