• Title/Summary/Keyword: switching power supply

Search Result 598, Processing Time 0.026 seconds

Development of the Power Supply with Reduced Conduction Loss and Switching Stress on the Full-Bridge DC-DC Converter (풀브리지 DC-DC 컨버터의 도전손실과 스위칭 스트레스를 저감한 전원장치 개발)

  • Ra Byung-Hun;Song Dae-Hyun;Kim Kwang-Tae;Lee Hyun-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.608-611
    • /
    • 2001
  • This paper is indicating the problems, which are the conduction loss on the high frequency transformer, the protection of rectification diode as the snubber loss and the stress of switching main devices, as be made high current and high speed in the phase-shift switching full-bridge DC-DC converter is used the power supply's main circuit of high capacity. In this paper, to improve those problems, it is proposed that is the resonant circuit auxiliary can be reduced conduction losses and stabilized output control. And, it is constructed prototype of the power supply as the result of computer simulations.

  • PDF

Operating Analysis of Power Factor Compensation Condenser and Series Reactor in the Induction Generator (유도발전기 역률 보상 콘덴서와 직렬 리액터의 동작 분석)

  • Kim, Jong-Gyeum;Park, Young-Jeen
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.3
    • /
    • pp.593-598
    • /
    • 2017
  • Induction generator is always required reactive power in order to generate a rotating magnetic field as an inductive load. The reactive power must be continuously supplied to the induction generator as well as load of distribution system from the power supply side. So the power factor of the power supply side during the induction generation operation is low. Condenser is installed in order to raise the low power factor of the induction generator. Switching transients occurs when the power supply of the capacitor is turned on in order to ensure the low power factor. When using the reactor in series with the capacitor in order to reduce the influence of switching transient, it can affect the reactive power by the condenser voltage rises. In this study, we analyzed the operating characteristics for power and power factor of induction generator in accordance with the presence or absence of the application of the serial reactors for switching transients reduction of the condenser and the condenser for power factor correction.

A study on the operation efficiency protection circuit of the power supply (전원장치의 동작효율 보호회로에 관한 연구)

  • Jeong, Seong-Yun;Choi, Hyun-Su;Baek, Jong-Ok;Ahn, Tae-Young
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.93-94
    • /
    • 2014
  • Recently, According to increase of power demand, it was increased a demand that switching power supply have characteristic of low-loss and high-efficiency. So increase of using device, the failure rate increases and service life problem arises. Even though normal circuit protection is applied in designing stage, it is often hard to identify the cause of malfunction in certain cases such as fatigued power supply due to over-running, malfunctions of main elements or over heating. This report will cover experimental results with the prototype we made, that monitors the efficiency of switching power supply and that protects a circuit when it drops below the standard value.

  • PDF

A Study on the Auxiliary Power Supply for the Railway Vehicle by Using Wide Band Gap Device (Wide Band Gap 소자를 적용한 철도차량용 보조전원장치에 관한 연구)

  • Choi, Yeon-Woo;Lee, Byoung-Hee
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.23 no.3
    • /
    • pp.168-173
    • /
    • 2018
  • In this paper, an auxiliary power supply (APS) for railroad cars is proposed. The APS can reduce the number of devices required to supply power through structural modification and operates at a high switching frequency by application of a SiC device. The voltage stress on the device in the proposed circuit can be reduced to less than half of the input voltage of the system; thus, a device with low breakdown voltage can be designed. By adapting a SiC device instead of an IGBT device, the proposed circuit can reduce switching and conduction losses and operate at a high switching frequency, thereby reducing output voltage and inductor current ripples in the proposed circuit. The theoretical analysis results of the proposed APS are verified with a 40 kW computer-based simulation and a 2 kW experiment.

A Study on Reactor Capacitance Estimation Algorithm and 5kW Plasma Power Supply Design for Linear Output Control of Wide Range (넓은 범위의 선형 출력 제어를 위한 5kW 플라즈마 전원장치 설계 및 반응기 커패시턴스 추정 알고리즘의 관한 연구)

  • Noh, Hyun-Kyu;Lee, Jun-Young;Kim, Min-Jea
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.21 no.6
    • /
    • pp.514-524
    • /
    • 2016
  • This work suggests a study on 5 kW plasma power supply design and reactor capacitance estimation algorithm for a wide range of linear output control to operate a plasma reactor. The suggested study is designed to use a two-stage circuit and control the full-bridge circuit of the two-stage circuit using the buck converter output voltage of the single-stage circuit. The switching frequency of the full-bridge circuit is designed to operate through high-frequency switching and obtain maximum output using LC parallel resonance. Soft switching technique(ZVS) is used to reduce the loss caused by high-frequency switching, and duty control of the buck converter is applied to control a wide range of linear output. The internal capacitance of the reactor cannot easily be extracted, and thus, the reactor cannot be operated in an optimized resonant state. To address this issue, this work designs the internal capacitance of the reactor such that estimations can be performed with the developed reactor capacitance estimation algorithm applied to the internal capacitance of the reactor. A 5 kW plasma power supply is designed for a wide range of linear output control, and the validity of the study on the reactor capacitance estimation algorithm is verified.

A Study on the Power Supply using Soft-switching Dual TTFC Pre-regulator (소프트 스위칭 Dual TTFC Pre-regulator를 사용한 전원장치에 관한 연구)

  • Lee, Dong-Hyun;Kim, Yong;Eom, Tae-Min;Lee, Kyu-Hoon;Baek, Soo-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1009_1010
    • /
    • 2009
  • This paper presents a power supply system with pre-regulator using zero voltage switching (ZVS) interleaving two-transistor forward converter for high input voltage and high power application. A SMPS has a advantage that a good efficiency, small size and light weight but has a noise problem. A linear power supply system has a advantage that a good stability, low ripple and noise but has a disadvantage that a big size, low efficiency and heat problem. To alleviate these problems, we propose an power supply system using dual ZVS interleaving two-transistor forward pre-regulator. The proposed converter is verified on a 1kW, 50kHz experimental prototype.

  • PDF

Study on the energy savings in the mobile communication repeater using a power factor correction circuit (역률보상회로를 이용한 이동통신 중계기의 에너지 절감에 관한 연구)

  • Lim, Byoung-Chul;Yoon, Wonsik
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.8
    • /
    • pp.1854-1860
    • /
    • 2014
  • In this paper, the energy saving on mobile communication repeater is studied. DB(Dual Band) small repeater, which is currently used in the field for indoor coverage, is adopted as a test unit. For reducing the power consumption, PFC (Power Factor Correction) is included on SMPS (Switching Mode Power Supply) of the DB small repeater. The test results show that approximately 38.9% of the power consumption is reduced comparing with the repeater without PFC. It means that approximately 230.43kWh per unit can be saved annually.

Dual Utility AC Line Voltage Operated Voltage Source and Soft Switching PWM DC-DC Converter with High Frequency Transformer Link for Arc Welding Equipment

  • Morimoto Keiki;Ahmed NabilA.;Lee Hyun-Woo;Nakaoka Mutsuo
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.5B no.4
    • /
    • pp.366-373
    • /
    • 2005
  • This paper presents two new circuit topologies of the dc busline side active resonant snubber assisted voltage source high frequency link soft switching PWM full-bridge dc-dc power converters acceptable for either utility ac 200V-rms or ac 400V-rms input grid. These high frequency switching dc-dc converters proposed in this paper are composed of a typical voltage source-fed full-bridge PWM inverter, high frequency transformer with center tap, high frequency diode rectifier with inductor input filter and dc busline side series switches with the aid of a dc busline parallel capacitive lossless snubber. All the active switches in the full-bridge arms as well as dc busline snubber can achieve ZCS turn-on and ZVS turn-off transition commutation with the aid of a transformer leakage inductive component and consequently the total switching power losses can be effectively reduced. So that, a high switching frequency operation of IGBTs in the voltage source full bridge inverter can be actually designed more than about 20 kHz. It is confirmed that the more the switching frequency of full-bridge soft switching inverter increases, the more soft switching PWM dc-dc converter with a high frequency transformer link has remarkable advantages for its power conversion efficiency and power density implementations as compared with the conventional hard switching PWM inverter type dc-dc power converter. The effectiveness of these new dc-dc power converter topologies can be proved to be more suitable for low voltage and large current dc-dc power supply as arc welding equipment from a practical point of view.

Design and Fabrication of Heater-triggered Switching System for the Charging of Bi-2223 Pancake Load (Bi-2223 팬케익부하 충전용 히터-트리거 스위칭 장치의 설계 및 제작)

  • 김영식;윤용수;배덕권;안민철;임대준;김호민;고태국
    • Progress in Superconductivity and Cryogenics
    • /
    • v.6 no.1
    • /
    • pp.43-48
    • /
    • 2004
  • This paper deals with design and fabrication of heater-triggered switching system for the high-Tc superconducting (HTS) power supply with series-connected double-pancake load. Amongst all components, heater triggering is the most important element for the performance of HTS power supply. To fabricate the optimal heater-triggered system, its characteristics have been analysed through the simulation and expriment. The thermal analysis of switching parts of the Bi-2223 solenoid according to the heater input was carried out. Based upon the analysis, 8A electromagnet current and 1.5A DC Heater current were optimally derived, and 8s and 20s for the pumping period were selected in this experiment. In the experiment. the maximum pumping current reached about 24A with Bi-2223 pancake load of 6mH.

A Study on High Precision and High Stability Digital Magnet Power Supply Using Second Order Delta-Sigma modulation (2차 델타 시그마 변조기법을 이용한 고 정밀 및 고 안정 디지털 전자석 전원 장치에 관한 연구)

  • Kim, Kum-Su;Jang, Kil-Jin;Kim, Dong-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.3
    • /
    • pp.69-80
    • /
    • 2015
  • This paper is writing about developing magnet power supply. It is very important for power supply to obtain output current in high precision and high stability. As a switching noise and a power noise are the cause of disrupting the stability of output current, to remove these at the front end, low pass filter with 300Hz cutoff frequency is designed and placed. And also to minimize switching noise of the current into magnet and to stop abrupt fluctuations, output filter should be designed, when doing this, we design it by considering load has high value inductance. As power supply demands the stability of less than 5ppm, high precision 24bit(300nV/bit) analog digital converter is needed. As resolving power of 24bit(300nV/bit) analog digital converter is high, it is also very important to design the input stage of analog digital converter. To remove input noise, 4th order low pass filter is composed. Due to the limitation of clock, to minimize quantization error between 15bit DPWM and output of ADC having 24bit resolving power, ${\Sigma}-{\Delta}$ modulation is used and bit contracted DPWM is constituted. And before implementing, to maximize efficiency, simulink is used.