• Title/Summary/Keyword: switching

Search Result 9,575, Processing Time 0.038 seconds

Soft Switching Forward Converter Using Non-Dissipative Snubber (무손실 스너버 적용 소프트 스위칭 Forward 컨버터)

  • 김은수;김태진;최해영;조기연;김윤호
    • Proceedings of the KIPE Conference
    • /
    • 1997.07a
    • /
    • pp.256-260
    • /
    • 1997
  • To achieve high efficiency in high power and high frequency applications, reduction of switching losses and noise is very important. In this paper, an improved soft switching forward converter is proposed. The proposed converter is constructed by using non-dissipative snubbers in parallel with the main switch and output diode of the conventional forward converter. Due to the use of the non-dissipative snubbers in the primary and secondary, the proposed converter achieves zero-voltage and zero-current switching for all switching devices without switching losses and output diode recovery losses. The complete operating principles, theoritical analysis, experimental results will be presented.

  • PDF

High Frequency Inverter using Zero-Voltage-Switching (Zero-Voltage-Switching을 이용한 고주파 인버어터)

  • Sim, K.Y.;Moon, C.S.;Kim, D.H.;Kim, Y.H.;Yoo, D.W.
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.1133-1135
    • /
    • 1992
  • This paper describes high frequency inverter using zero voltage switching(ZVS). The ZVS operation is achieved to reduce the switching stress and switching loss under high speed switching. The proposed circuit configuration and performance are discussed. Its operation characteristics are evaluated through computer-aided simulation.

  • PDF

New Zero-Current-Switching PWM Converters with Soft-Switching Auxiliary Switch (소프트 스위칭방식의 보조스위치를 갖는 새로운 ZCS-PWM 컨버터)

  • Ma, Keun-Su;Kim, Yang-Mo
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.1002-1004
    • /
    • 2001
  • In conventional zero-current-switching(ZCS) PWM converters, the switching loss, stress and noise can't be minimized because they adopt auxiliary switches operated in hard-switching. In this paper, new ZCS-PWM converters of which auxiliary switches always operate with soft-switching are proposed. Therefore, the proposed ZCS-PWM converters are most suitable for systems requiring high-power density. The characteristics of these converters are verified by experimental results.

  • PDF

Switching current density for spin transfer torque magnetic random access memory with Dzaloshinskii-Moriya Interaction

  • Song, Kyungmi;Lee, Kyung-Jin
    • Proceedings of the Korean Magnestics Society Conference
    • /
    • 2015.05a
    • /
    • pp.78-79
    • /
    • 2015
  • We investigate the switching current for various cell diameters and DM interaction. We find that the current density for switching can depend strongly on the cell size when the switching is governed by the domain wall motion. Moreover the switching current density is also strongly influenced by DM interaction. In the presentation, we will discuss the effect of domain wall formation and more various DMI constant on the switching current desity in detail.

  • PDF

New Zero-Current-Switching PWM Converters with Low Switching Loss (손실을 최소화한 새로운 영전류 스위칭 방식의 PWM 컨버터)

  • Ma, Keun-Su;Kim, Yang-Mo
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1193-1195
    • /
    • 2000
  • In conventional zero-current-switching(ZCS) PWM converters, the switching loss, stress and noise can't be minimized because they adopt auxiliary switches operated in hard-switching. In this paper, new ZCS-PWM converters of which auxiliary switches always operate with soft-switching are proposed. Therefore, the proposed ZCS-PWM converters are most suitable for systems requiring high-power density. The characteristics of these converters are verified by results of simulation.

  • PDF

Effect of interactivity, stickiness, switching barrier on intention to use (패션몰 소비자의 상호작용성, 웹흡입력, 전환장벽이 이용의도에 미치는 영향)

  • Lee, Ok-Hee
    • Journal of Fashion Business
    • /
    • v.14 no.2
    • /
    • pp.166-178
    • /
    • 2010
  • The purposes of this study were to investigate the impacts of interactivity, site stickiness, and switching barrier on intention to use. For this purpose, the study tested covariance structural model which set relationships among independent variable(interactivity), meditated variables(site stickiness and switching barrier), and dependent variable(intention to use). The data were collected from a sample of 239 internet shopper of college female students. The covariance structural model and research hypothesis analyzed by using SPSS 16.0 and AMOS 5.0 program. The results are as follows: First, the structural model is accepted significantly. Second, interactivity had a positive influence on site stickiness, switching barrier, and intention to use. And it was found to have a indirect effect on intention to use through site stickiness and switching barrier. Third, site stickiness had a positive influence on switching barrier. Forth, site stickiness and switching barrier had a positive impact on intention to use.

Turn-on Loss Reduction for High Voltage Power Stack Using Active Gate Driving Method

  • Kim, Jin-Hong;Park, Joon Sung;Gu, Bon-Gwan;Won, Chung-Yuen
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.2
    • /
    • pp.632-642
    • /
    • 2017
  • This paper presents an improved approach towards reducing the switching loss of insulated gate bipolar transistors (IGBTs) for a medium-capacity-class power conditioning system (PCS). In order to improve the switching performance, the switching operation is analyzed, and based on this analysis, an improved switching method that reduces the switching time and switching loss is proposed. Compared to a conventional gate drive scheme, the switching loss, switching time, and delay are improved in the proposed gate driving method. The performance of the proposed gate driving method is verified through several experiments.

The effect of switching costs on resistance to change in the use of software

  • Perera, Nipuna;Kim, Hee-Woong
    • 한국경영정보학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.539-544
    • /
    • 2007
  • People tend to resist changing their software even alternatives are better then the current one. This study examines the resistance to change in the use of software from the switching costs perspective based on status quo bias theory. For this study, we select Web Browsers as software. Based on the classification of switching costs into three groups (psychological, procedural, and loss), this study identifies six types of switching costs (uncertainty, commitment, learning, setup, lost performance, and sunk costs). This study tests the effects of six switching costs on user resistance to change based on the survey of 204 web browser users. The results indicate that lost performance costs and emotional costs have significant effects on user resistance to change. This research contributes towards understanding of switching costs and the effects on user resistance to change. This study also offers suggestions to software vendors for retaining their users and to organizations for managing user resistance in switching and adopting software.

  • PDF

A Family of Zero Current and Zero Voltage Switching Bidirectional DC-DC Converter with Soft Switched Auxiliary Circuit (소프트 스위칭 방식의 보조 회로를 갖는 영전류 및 영전압 스위칭 양방향 DC-DC 컨버터)

  • Lee, Il-Ho;Kim, Jun-Gu;Kim, Jae-Hyung;Won, Chung-Yuen;Jung, Yong-Chae
    • Proceedings of the KIPE Conference
    • /
    • 2011.07a
    • /
    • pp.438-439
    • /
    • 2011
  • In this paper, soft switching bidirectional DC-DC converter is proposed. The proposed topology is added two auxiliary switches, two resonant capacitors and one resonant inductor to convectional bidirectional DC-DC converter. Therefore, this proposed topology can reduce switching loss of each power switch by ZVS (Zero Voltage Switching) and ZCS (Zero Current Switching). We have performed mode analysis, simulation and experiment for the proposed topology.

  • PDF