• Title/Summary/Keyword: swirling Flow

Search Result 217, Processing Time 0.021 seconds

Asymmetric flows of non-Newtonian fluids in symmetric stenosed artery

  • Hun Jung;Park, Jong-Wook;Park, Chan-Guk
    • Korea-Australia Rheology Journal
    • /
    • v.16 no.2
    • /
    • pp.101-108
    • /
    • 2004
  • The hemodynamics behavior of the blood flow is influenced by the presence of the arterial stenosis. If the stenosis is present in an artery, normal blood flow is disturbed. In the present study, the characteristics of pulsatile flow in the blood vessel with stenosis are investigated by the finite volume method. For the validation of numerical model, the computation results are compared with the experimental ones of Ojha et al. in the case of 45% stenosis with a trapezoidal profile. Comparisons between the measured and the computed velocity profiles are favorable to our solutions. Finally, the effects of stenosis severity and wall shear stress are discussed in the present computational analysis. It can be seen, where the non-dimensional peak velocity is displayed for all the stenosis models at a given severity of stenosis, that it is exponentially increased. Although the stenosis and the boundary conditions are all symmetric, the asymmetric flow can be detected in the more than 57% stenosis. The instability by a three-dimensional symmetry-breaking leads to the asymmetric separation and the intense swirling motion downstream of the stenosis.

A Numerical Study of the Turbulent Flow Characteristics in the Inlet Transition Square Duct Based on Roof Configuration (4각 안내덕트 루프형상에 의한 난류특성변화 수치해석)

  • Yoo, Geun-Jong;Choi, Hoon-Ki;Choi, Kee-Lim;Shin, Byeong-Ju
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.7
    • /
    • pp.541-551
    • /
    • 2009
  • Configuration of the inlet transition square duct (hereinafter referred to as "transition duct") for heat recovery steam generator (hereinafter referred to as "HRSG") in combined cycle power plant is limited by the construction type of HRSG and plant site condition. The main purpose of the present study is to analyze the effect of a variation in turbulent flow pattern by roof slop angle change of transition duct for horizontal HRSG, which is influencing heat flux in heat transfer structure to the finned tube bank. In this study, a computational fluid dynamics(CFD) is applied to predict turbulent flow pattern and comparisons are made to 1/12th scale cold model test data for verification. Re-normalization group theory (RNG) based k-$\epsilon$ turbulent model, which improves the accuracy for rapidly strained flow and swirling flow in comparison with standard k-$\epsilon$ model, is used for the results cited in this study. To reduce the amount of computer resources required for modeling the finned tube bank, a porous media model is used.

Numerical Analysis on the Flow Uniformity in a Pump Sump Model with Multi Pump Intake (다중 흡수정을 갖는 펌프장 모델의 유동균일성 해석)

  • Choi, Jong-Woong;Choi, Young-Do;Lim, Woo-Seop;Lee, Young-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.12 no.4
    • /
    • pp.14-22
    • /
    • 2009
  • The head-capacity curves for pumps developed by the pump manufacturer are based on tests of a single pump operating in a semi-infinite basin with no close walls or floors and with no stray currents. Therefore, flow into the pump intake is with no vortices or swirling. However, pump station designers relying on these curves to define the operating conditions for the pump selected sometimes meet the reductions of capacity and efficiency, as well as the increase of vibration and additional noise, which were caused by air-entered flow in the pump station. From this background, the authors are carrying out a systematic study on the flow characteristics of intakes within a sump of pump station model. Multi-intake sump model with anti-submerged vortex device basin is designed and the characteristics of submerged vortex is investigated in the flow field by numerical simulation. In this study, a commercial CFD code is used to predict the vortex generation in the pump station accurately. The analysed results by CFD show that the vortex structure and effect of anti-submerged vortex device are different at each pump intake channel.

A Study on the Flow Characteristics around Intakes within a Sump by PIV (PIV에 의한 흡입수조내 흡입관 주위의 유동특성에 관한 연구)

  • Choi, J. W.;Kim, J. H.;Kim, K. Y.;Kim, Y. T.;Lee, Y. H.
    • The KSFM Journal of Fluid Machinery
    • /
    • v.5 no.3 s.16
    • /
    • pp.33-39
    • /
    • 2002
  • The head-capacity corves for pumps developed by the pump manufacturer are based on tests of a single pump operating in a semi-infinite pool with no nearby walls or floors and with no stray currents. Hence, flow into the pump suction is symmetrical with no vortices or swirling. Pump station designers rely on these curves to define the operating conditions for the pump selected. However, various constraints such as size, cost, and limitations on storage time require walls, floors, and pump intakes to be close proximity to each other. From this background, the authors are carrying out a systematic study on the flow characteristics of intakes within a sump found in pump stations. Model pump intake basin is designed and PIV is adopted as a measuring tool to capture the instantaneous flow patterns. Special attention is paid to investigate the flow patterns near the free surface, side-wall, and back-wall due to different clearances from back-wall to vortical intake pipe. Moreover, the locations and patterns of the various types of vortices that were found in the examinations are discussed.

A study on the Flow Characteristics of a Vortex originated in the Free Surface within a Sump in a Pump Station by PIV (PIV에 의한 펌프장 흡입수조의 자유표면에서 발생하는 와의 운동특성에 관한 연구)

  • Choi, J. W.;Kim, B. S.;Lee, H.;Kim, Y. T.;Lee, Y. H.
    • 유체기계공업학회:학술대회논문집
    • /
    • 2002.12a
    • /
    • pp.95-101
    • /
    • 2002
  • The head-capacity curves for pumps developed by the pump manufacturer are based on tests of a sin91e pump operating in a semi-infinite pool with no nearby walls or floors and no stray currents. Hence, flow into the pump suction is symmetrical with no vortices or swirling. Pump station designers rely on these curves to define the operating conditions for the pump selected. But various constraints such as size, cost, and limitations on storage time require walls, floors, and pump intakes to be close proximity to each other. From this background, the authors are carrying out a systematic study on the flow characteristics of intakes within a sump found within a sump of pump stations. Model pump intake basin is designed and PIV is adopted as a measuring tool to capture the instantaneous flow patterns. Special attention is paid to investigate the flow patterns near the free surface due to different clearances from back-wall to vertical intake pipe with bell mouse and without. Moreover, the locations and vorticities of the various types of vortices that were found in the examinations are discussed.

  • PDF

LES Studies on Flow Structure and Flame Characteristic with Equivalence Ratios in a Swirling Premixed Combustor (선회 예혼합연소기에서 당량비 변화에 따른 유동구조 및 화염특성에 관한 LES 연구)

  • Hwang, Cheol-Hong;Kim, Se-Won;Lee, Chang-Eon
    • Journal of the Korean Society of Combustion
    • /
    • v.11 no.4
    • /
    • pp.27-35
    • /
    • 2006
  • The impacts of equivalence ratio on flow structure and flame dynamic in a model gas turbine combustor are investigated using large eddy simulation(LES). Dynamic k-equation model and G-equation flamelet model are employed as LES subgrid model for flow and combustion, respectively. As a result of mean flow field for each equivalence ratio, the increase of equivalence ratio brings about the decrease of swirl intensity through the modification of thermal effect and viscosity, although the same swirl intensity is imposed at inlet. The changes of vortical structure and turbulent intensity etc. near flame surface are occurred consequently. That is, the decrease of equivalence ratio can leads to the increase of heat release fluctuation by the more increased turbulent intensity and fluctuation of recirculation flow. In addition, the effect of inner vortex generated from vortex breakdown on the heat release fluctuation is increased gradually with the decrease of equivalence ratio. Finally, it can be identified that the variations of vortical structure play an important role in combustion instability, even though the small change of equivalence ratio is occurred.

  • PDF

A PIV Measurement on Flow Characteristics of Intakes within a Sump in a Pump Station (펌프장의 흡입수조내 흡입관의 유동특성에 관한 PIV 측정)

  • Lee, Yeong-Ho;Kim, Yu-Taek;Kim, Jeong-Hwan;Choe, Jong-Ung
    • 유체기계공업학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.209-215
    • /
    • 2001
  • The head-capacity curves for pumps developed by the pump manufacturer are based on tests of a single pump operating in a semi-infinite pool with no nearby walls or floors and no stray currents, Hence, flow into the Pump suction is symmetrical with no vortices or swirling. Pump station designers rely on these curves to define the operating conditions for the pump selected. But various constraints such as size, cost, and limitations on storage time require walls, floors, and pump intakes to be close proximity to each other. From this background, the authors are carrying out a systematic study on the flow characteristics of intakes within a sump found in pump stations. Model pump intake basin is designed and PIV is adopted as a measuring tool to capture the instantaneous flow patterns. Special attention is paid to investigate the flow patterns near the free surface, side-wall and back-wall due to different clearances from back-wall to vertical in take pipe. Moreover, the locations and vorticities of the various types of vortices that were found in the examinations are discussed.

  • PDF

Study on Flow Characteristics around Intakes within a Sump by PIV (PIV에 의한 흡입수조내 흡입관 주위의 유동특성에 관한 연구)

  • Choi, J.W.;Kim, J.H.;Nam, Cheong-Do;Kim, Y.T.;Lee, Y.H.
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.563-569
    • /
    • 2001
  • The head-capacity curves for pumps developed by the pump manufacturer are based on tests of a single pump operating in a semi-infinite pool with no nearby walls or floors and no stray currents, Hence, flow into the pump suction is symmetrical with no vortices or swirling. Pump station designers rely on these curves to define the operating conditions for the pump selected. But various constraints such as size, cost, and limitations on storage time require walls, floors, and pump intakes to be close proximity to each other. From this background, the authors are carrying out a systematic study on the flow characteristics of intakes within a sump found in pump stations. Model pump intake basin is designed and PIV is adopted as a measuring tool to capture the instantaneous flow patterns. Special attention is paid to investigate the flow patterns near the free surface, side-wall and back-wall due to different clearances from back-wall to vertical in take pipe. Moreover, the locations and vorticities of the various types of vortices that were found in the examinations are discussed.

  • PDF

Development of a Hybrid/Dual Swirl Jet Combustor for a Micro-Gas Turbine (Part I: Experimental Study on Geometric Optimization) (마이크로 가스터빈을 위한 하이브리드/이중 선회제트 연소기의 개발 (Part I: 형상 최적화를 위한 실험적 연구))

  • Park, Tae-Joon;Hwang, Cheol-Hong;Lee, Kee-Man
    • 한국연소학회:학술대회논문집
    • /
    • 2012.04a
    • /
    • pp.199-200
    • /
    • 2012
  • An experimental study on geometric optimization was conducted to develop a hybrid/dual swirl jet combustor for a micro-gas turbine. A hybrid concept indicating a combination of swirling jet partially premixed and premixed flames were adopted to achieve high flame stability as well as clean combustion. Location of pilot nozzle, angle and direction of swirl vane were varied as main parameters with a constant fuel flow rate for each nozzle. The results showed that the variation in location of pilot nozzle resulted in significant change in swirl intensity due to the change in flow area near burner exit, and thus, optimized nozzle location was determined on the basis of CO and NOx emissions under conditions of co-swirl flow and swirl $angle=30^{\circ}$. The increase in swirl angle (from $30^{\circ}$ to $45^{\circ}$) enhanced the emission performances, in particular, with a significant reduction of CO emission near lean-flammability limit. It was observed that the CO emission near lean-flammability limit was further reduced through the counter-swirl flow. However, there was not significant change in the NOx emission in the operating conditions (i.e. equivalence ratio of 0.6~0.7) between the co- and the counter-swirl flow.

  • PDF

A Multidimensional Simulation of Swirl Flow and Turbulent Combustion in a Cylinder of SI Engine (전기점화 기관의 선회 유동 및 연소에 관한 수치해석)

  • 정진은;김응서
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.9
    • /
    • pp.1744-1759
    • /
    • 1992
  • A multidimensional simulation of turbulent flow and combustion with swirl in the cylinder of SI engine is implemented to clarify the effects of swirl. present simulation employs the ICED-ALE numerical technique, the skew-upwind difference scheme, a modified k_.epsilon. turbulence model, a combustion model of Arrhenius type and turbulence-mixing-control type. First, the calculations for swirling flow in an axisymmetric cylinder are carried out. The results are compared with the experimental data to validate the numerical analysis. Second, the calculations for intake, compression and combustion processes in an axisymmetric cylinder are performed. The effects of swirl on turbulent flow and combustion are examined through the parametric study of swirl number 0.0, 0.6, 1.2 and 2.4. As a result, it is numerically shown that the turbulent kinetic energy and the swirl velocity, which are produced during the intake process, affect the combustion process.