• Title/Summary/Keyword: swell source

Search Result 34, Processing Time 0.026 seconds

Dynamic Voltage Restorer(DVR) with a Z-Source AC Converter Topology (Z-소스 교류 컨버터 토폴로지의 동적 전압 보상기)

  • Lim, Young-Cheol;Jung, Young-Gook
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.9
    • /
    • pp.36-43
    • /
    • 2010
  • This paper proposes a new type of voltage sag-swell compensator based on a Z-source AC-AC converter. The proposed topology employs a pulse width modulation (PWM) Z-source AC-AC converter along with a injection transformer. A safe commutation strategy is used to eliminate voltage spikes on switches without snubber circuit. During a voltage sag or swell, the proposed system controls the adding or missing voltage and maintains the rated voltage of sinusoidal waveform at the terminals of the critical loads. The proposed system is able to compensate 20[%] voltage swell and is also able to compensate 60[%] voltage sag. In order to control and detect the voltage sag and swell, the peak voltage detection method is applied. Also, the operating principles of the proposed system are described, and a circuit analysis is provided. Finally, PSIM simulation and experimental results are presented to verify the proposed concept and theoretical analysis.

Single-Phase Series Type Quasi Z-Source Voltage Sag-Swell Compensator for Voltage Compensation of Entire Region (전 영역의 전압보상을 위한 단상 직렬형 Quasi Z-소스 전압 Sag-Swell 보상기)

  • Eom, Jun-Hyun;Jung, Young-Gook;Lim, Young-Cheol
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.18 no.4
    • /
    • pp.322-332
    • /
    • 2013
  • Conventional single-phase series quasi Z-source voltage compensator can not compensate for voltage sag less than 50% that frequently occurs in the industrial field. In this study, single-phase series quasi Z-source voltage sag-swell compensator which can compensate the voltage variation of entire range is proposed. The proposed system is composed of two quasi Z-source AC-AC converters connected in series with output terminal stage. Voltage sag less than 50% could be compensated by the intersection switching control of the upper converter duty ratio and of the upper converter duty ratio. Also the compensation voltage and its flowchart for each compensation mode are presented for entire sag-swell region. To confirm the validity of the proposed system, a DSP(DSP28335) controlled experimental system was manufactured. As a result, the proposed system could compensate for the voltage sag/swell of 20% and 60%. Finally, voltage compensation factor and THD(Total Harmonic Distortion) according to voltage variation and load change were measured, and voltage quality shows a good results.

A Single-Phase Quasi Z-Source Dynamic Voltage Restorer(DVR) (단상 Quasi Z-소스 동적전압보상기(DVR))

  • Lee, Ki-Taeg;Jung, Young-Gook;Lim, Young-Cheol
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.15 no.4
    • /
    • pp.327-334
    • /
    • 2010
  • This paper deals with a single-phase dynamic voltage restorer(DVR) with a quasi Z-source topology. The proposed system based on a single-phase quasi Z-source PWM ac-ac converter which have features such as the input voltage and output voltage are sharing ground, and input current operates in continuous current mode(CCM). For the detection of voltage sag-swell, peak voltage detection method is applied. Also, the circuit principles of the proposed system are described. During the 60% severe voltage sag and 30% voltage swell, the proposed system controls the adding or missing voltage and maintains the rated voltage of sinusoidal waveform at the terminals of the critical loads. Finally, PSIM simulation and experimental results are presented to verify the proposed concept and theoretical analysis.

Stand-Alone Type Single-Phase Fuel Cells Micro-Source with ac Voltage Compensation Capability (교류전압 보상 기능을 갖는 독립형 단상 연료전지 마이크로 소스)

  • Jung, Young-Gook
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.1
    • /
    • pp.35-41
    • /
    • 2009
  • This paper proposes a stand alone type single-phase fuel cells micro-source with a voltage sag compensator for compensating the ac output voltage variations (sag or swell) of micro-source. The proposed micro-source is consist of a PEM(polymer electrolyte membrane) fuel cells simulator, a full bridge de converter, a 60Hz PWM(pulse width modulation) VSI(voltage source inverter), and a voltage sag compensator. Voltage sag compensator is similar to the configuration of hybrid series active power filter, and it is directly connected to micro-source through the injection transformer. Compensation algorithm of a voltage sag compensator adopts a single phase p-q theory. Effectiveness of the proposed the system is verified by the PSIM(power electronics simulation tool) simulation in the steady state and transient state which the proposed system is able to simultaneously compensate the harmonic current and source voltage sag or swell.

Three-Phase Z-Source Dynamic Voltage Restorer with a Fuel Cells Source (연료전지 전원을 갖는 3상 Z-소스 동적 전압 보상기)

  • Jung, Young-Gook
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.10
    • /
    • pp.41-48
    • /
    • 2008
  • This paper proposes a three-phase Z-source dynamic voltage restorer (Z-DVR) to mitigate the voltage sag for the critical loads. The proposed system is composed of passive filter and Z-source topology inverter. As an ESS(Energy Storage System) of the proposed system is employed the Proton Exchange Membrane Fuel Cells (PEMFC). To calculate and control the harmonics and compensation voltage, $i_{d}-i_{q}$ theory in dq rotating reference frame and PI controller are used. In case that three-phase voltage sags occurred, a PSIM simulation was done for the performance comparison of the conventional method employed battery stacks and proposed method. As a result, considering the voltage compensation performance, each method was nearly similar. Also, the compensation performance and the %THD(%Total Harmonic Distortion) result under the various source voltage conditions (sag or swell) were presented and discussed to show the performance of the proposed system.

Characteristics of Voltage Sag/Swell Compensator Utilizing Single-Phase Matrix Converter

  • Yamamoto, Kichiro;Ikeda, Keisuke;Tsurusaki, Yu;Ikeda, Minoru
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.2 no.4
    • /
    • pp.447-453
    • /
    • 2013
  • Compensating characteristics of a voltage sag/swell compensator utilizing single-phase matrix converter is examined. First, system configuration and operation for both voltage sag and swell are described. Next, in order to suppress pulsations of the source voltage, a countermeasure using low pass filter and all pass filter is introduced. Then, compensating characteristics of the compensator are investigated for R-L load by simulation. Finally, the validity of the simulated results is confirmed by the experimental results.

Single-Phase Impedance-Source Dynamic Voltage Restorer (단상 임피던스-소스 동적 전압 보상기)

  • Park, H.J.;Jung, Y.G.;Lim, Y.C.
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.458-461
    • /
    • 2008
  • This paper deals with a single-phase impedance-source dynamic voltage restorer (Impedance-DVR) to mitigate voltage sag/swell for the critical loads. The proposed system is composed of passive filter and impedance-source topology inverter. As an ESS(Energy Storage System) of the proposed system is employed the Proton Exchange Membrane Fuel Cells (PEMFC). To calculate and control the compensation voltage, single-phase $^id-^iq$ theory in dq rotating reference frame and PI controller are used. Simulation results under voltage sag and swell are presented to show the performance.

  • PDF

Z-source power quality conditioner with compensation capability of voltage sag-swell and harmonics (전압sag-swell과 고조파 보상기능을 갖는 Z-소스 전력품질보상시스템)

  • Park, Hee-Jae;Oh, Seung-Yeol;Jung, Young-Gook;Lim, Young-Cheol
    • Proceedings of the KIPE Conference
    • /
    • 2009.11a
    • /
    • pp.290-292
    • /
    • 2009
  • 본 연구에서는 배전계통의 전압 및 전류 품질을 통합적으로 개선할 수 있는 수동필터 연계형 Z-소스 전력품질 보상 시스템을 제안한다. 제안된 시스템의 주안점은 전압의 변동을 보상하는 직렬형 인버터와 고조파를 보상하는 병렬형 인버터에 각각 Z-소스 토폴로지를 적용하는 것이다. 전압 sag와 swell이 발생하는 과도상태에서 제안된 시스템의 성능을 검증하기 위하여 PSIM시뮬레이션을 하여 타당성을 입증하였다.

  • PDF

Quasi Z-Source Voltage Sag-Swell Compensator by Instantaneous Value Detection Algorithm (순시치 검출 기법을 이용한 Quasi Z-소스 순간전압 Sag-Swell 보상기)

  • Lee, Ki-Taeg;Jung, Young-Gook;Lim, Young-Choel
    • Proceedings of the KIPE Conference
    • /
    • 2009.11a
    • /
    • pp.146-148
    • /
    • 2009
  • 본 논문에서는 새로운 Quasi Z-소스 순간전압 Sag-Swell 보상기를 제안한다. 제안된 시스템은 Quasi Z-소스 교류-교류 컨버터를 기반으로 하며, 입력단과 출력단이 공통 접지이며, 연속적인 입력전류로 동작하는 특징을 가지고 있다. 또한 평균치 제어 기법의 단점을 보완하기 위한 방법으로 실시간 샘플링 검출기법을 이용한 알고리즘을 적용하여 샘플링 구간 동안 평균치 값을 계산해서 순간전압 변동을 검출해 내는 기법을 적용했다.

  • PDF

The Analysis of Characteristics of Swell in Korea using the Ubiquitous Measurement System (유비쿼터스 관측시스템을 이용한 국내 너울의 특성규명에 관한 연구)

  • Jang, Bok-Jin;Yeo, Woon-Kwang;Lee, Jong-Kook;Park, Kwang-Soon
    • Journal of Korea Water Resources Association
    • /
    • v.41 no.8
    • /
    • pp.785-795
    • /
    • 2008
  • The swell is a major cause of interruption for the activity in a port and the ship navigation in coastal waters, coastal geographical changes, and the disaster with a loss of lives. However, many researches about the observation and the prediction of swells have not been conducted actively due to the difficulties to collect and synthesize the massive amount of long term field data for waves and meteorological information. In this study, the internet-based realtime monitoring system(Fieldbox) was developed to collect the wave data. The characteristics and main components of swells occurred in Korea were analyzed using wave data observed through the Fieldbox and the meteorological data collected by the KMA(Korea Meteorological Administration) and NASA(National Aeronautics and Space Administration). The characteristics of the swell generation patterns were analyzed using the monthly data of the Kwangan Tower between 2004 and 2006 to estimate the specific features such as sources and locations of swells generated in Korea.