• Title/Summary/Keyword: suture techniques

Search Result 89, Processing Time 0.019 seconds

Experimental cardiac transplantation in the mongrel dogs (II) (한국산 잡견에서의 실험적 심장 이식술 (II))

  • 이정렬
    • Journal of Chest Surgery
    • /
    • v.23 no.5
    • /
    • pp.844-853
    • /
    • 1990
  • We have performed 27 cases of orthotopic homologous cardiac transplantation using Korean mongrel dogs and one case of sham operation for the evaluation of harmful effect of cardiopulmonary bypass itself on the dog from April, 1989 to June, 1990. Our previous reports have already demonstrated basal hemodynamic and hematologic data on the canine homologous heart transplantation and the fundamental principles of transplantation of the heart. The mean body weight of recipients was 13.2$\pm$1.2kg with a rage of 11 ~ 15kg, and the hemodynamic and hematologic pictures were almost same as the result of previous reports from our hospital, except marked decrease in postoperative platelet count[from 3.18 $\pm$0.80x106/mm3 to 1.41$\pm$0 37x 106/mm3]. Mean survival time was 24.82$\pm$49.40 hours with the longest survival of 264 hours. Donor cardiectomy included coronary vasodilatation with diltiazem, potassium arrest, and the rapid cooling of the heart suspending in the specially designed ice-bath. Median sternotomy provided excellent exposure of the surgical field. 6 \ulcorner0 prolene suture was used for the anastomosis of both atrial cuffs and the great arteries, and we found the fact that stenosis, bleeding, thrombus formation around the anastomotic site could be decreased with the use of everted horizontal mattress suture techniques. Immunosuppression was done with a combination of lower dose Cyclosporin-A, Azathioprine, methyl-prednisolone, but our cases still showed too short survival to worry about graft rejection. Still poor was our quality control of experimental animal, we had much difficulties in postmortem evaluation of the dogs. Low cardiac output due to biventricular failure, intractable supraventricular or ventricular tachyarrhythmia, postoperative massive bleeding, sepsis were most frequent findings that could be thought as a cause of death. A few cases showed subendocardial patch hemorrhage in both ventricular cavity or atrial septum at autopsy, suggesting acute subendocardial infarction. Although our team overcome most of the technical problems of orthotopic heart transplantation, we should pile up further knowledges about donor heart preservation, quality control of animal, infection, rejection, the effect of the cardiopulmonary bypass to improve the results.

  • PDF

Preservation of keratinized mucosa around implants using a prefabricated implant-retained stent: a case-control study

  • Kim, Chang-Soon;Duong, Hieu Pham;Park, Jung-Chul;Shin, Hyun-Seung
    • Journal of Periodontal and Implant Science
    • /
    • v.46 no.5
    • /
    • pp.329-336
    • /
    • 2016
  • Purpose: The aim of this study was to clinically assess the impact of a prefabricated implant-retained stent clipped over healing abutments on the preservation of keratinized mucosa around implants after implant surgery, and to compare it with horizontal external mattress sutures. Methods: A total of 50 patients were enrolled in this study. In the test group, a prefabricated implant-retained stent was clipped on the healing abutment after implant surgery to replace the keratinized tissue bucco-apically. In the control group, horizontal external mattress sutures were applied instead of using a stent. After the surgical procedure, the width of the buccal keratinized mucosa was measured at the mesial, middle, and distal aspects of the healing abutment. The change in the width of the buccal keratinized mucosa was assessed at 1 and 3 months. Results: Healing was uneventful in both groups. The difference of width between baseline and 1 month was $-0.26{\pm}0.85mm$ in the test group, without any statistical significance (P=0.137). Meanwhile, the corresponding difference in the control group was $-0.74{\pm}0.73mm$ and it showed statistical significance (P<0.001). The difference of width between baseline and 3 months was $-0.57{\pm}0.97mm$ in the test group and $-0.86{\pm}0.71mm$ in the control group. These reductions were statistically significant (P<0.05); however, there was no difference between the 2 groups. Conclusions: Using a prefabricated implant-retained stent was shown to be effective in the preservation of the keratinized mucosa around implants and it was simple and straightforward in comparison to the horizontal external mattress suture technique.

Modified Double-Eyelid Blepharoplasty Using the Single-Knot Continuous Buried Non-Incisional Technique

  • Moon, Kyung-Chul;Yoon, Eul-Sik;Lee, Jun-Mun
    • Archives of Plastic Surgery
    • /
    • v.40 no.4
    • /
    • pp.409-413
    • /
    • 2013
  • Background Buried non-incisional double-eyelid blepharoplasty is a popular aesthetic procedure. Although various modified continuous suture techniques have been used to create a more natural appearance and to reduce downtime, complications such as loosening of the double fold, asymmetry, and foreign body reactions have been observed. Methods This study included 250 patients who underwent double-eyelid blepharoplasty between March 1997 and November 2012 using a modified single-knot continuous buried non-incisional technique. With 4 stab incisions in the upper eyelids, one of two needles loaded with double-armed 7-0 nylon was passed in one direction alternately through the dermis and the conjunctiva, while the other needle was passed subconjunctivally in the opposite direction. Both ends of the sutures were knotted within a lateral stab incision of the upper eyelids and were buried in the orbicularis oculi muscle. Results Most patients displayed satisfactory aesthetic results, and no significant complications occurred. There was no obvious regression of the double fold; however, 3 patients required reoperation to correct loosening of the fold on one side during the follow-up period. One patient presented with the suture knot subcutaneously, and the knot was removed in the clinic. Conclusions The modified single-knot continuous buried non-incisional technique is a simple and less time-consuming method for a durable double fold and provides satisfactory aesthetic results.

Feasibility of the AtriClip Pro Left Atrium Appendage Elimination Device via the Transverse Sinus in Minimally Invasive Mitral Valve Surgery

  • Shirasaka, Tomonori;Kunioka, Shingo;Narita, Masahiko;Ushioda, Ryohei;Shibagaki, Keisuke;Kikuchi, Yuta;Wakabayashi, Naohiro;Ishikawa, Natsuya;Kamiya, Hiroyuki
    • Journal of Chest Surgery
    • /
    • v.54 no.5
    • /
    • pp.383-388
    • /
    • 2021
  • Background: Achieving external access to and manual occlusion of the left atrial appendage (LAA) during minimally invasive mitral valve surgery (MIMVS) through a small right thoracotomy is difficult. Occlusion of the LAA using an epicardial closure device seems quite useful compared to other surgical techniques. Methods: Fourteen patients with atrial fibrillation underwent MIMVS with concomitant surgical occlusion of the LAA using double-layered endocardial closure stitches (n=6, endocardial suture group) or the AtriClip Pro closure device (n=8, AtriClip group) at our institution. The primary safety endpoint was any device-related adverse event, and the primary efficacy endpoint was successful complete occlusion of blood flow into the LAA as assessed by transthoracic echocardiography at hospital discharge. The primary efficacy endpoint for stroke reduction was the occurrence of ischemic or hemorrhagic neurologic events. Results: All patients underwent LAA occlusion as scheduled. The cardiopulmonary bypass and aortic cross-clamp times in the endocardial suture group and the AtriClip group were 202±39 and 128±41 minutes, and 213±53 and 136±44 minutes, respectively (p=0.68, p=0.73). No patients in either group experienced any device-related serious adverse events, incomplete LAA occlusion, early postoperative stroke, or neurologic complication. Conclusion: Epicardial LAA occlusion using the AtriClip Pro during MIMVS in patients with mitral valve disease and atrial fibrillation is a simple, safe, and effective adjunctive procedure.

Current Concepts in Arthroscopic Treatment of Anterior Shoulder Instability (견관절 전방 불안정에 대한 관절경적 최신 치료 경향)

  • Seo, Jae-Sung
    • Journal of Yeungnam Medical Science
    • /
    • v.20 no.1
    • /
    • pp.13-27
    • /
    • 2003
  • In the past, the report of shoulder instability undergoing open shoulder stabilization had satisfactory outcomes of greater than 90%. However, the functional loss of open procedure is severe in abduction and external rotation especially. Current arthroscopic techniques for shoulder instability result in success rate equal to open surgical procedure when the labrum is properly fixed to the glenoid rim using suture anchors, the capsule is tightened, and associated bony and soft tissue pathology is addressed. The arthroscopic surgery facilitates the view within shoulder joint for more accurate diagnosis, reduces operating time, minimises postoperative pain, reduces operative morbidity, improves shoulder function, and provides the possibility to perform other procedure simultaneously. However, to accomplish a successful arthroscopic stabilization procedure and to prevent complications, numerous advanced arthroscopic skill must be mastered. Although the arthroscope provides means to visualize new lesions, the pathomechanism and biomechanical explanation is not clear yet. Further studies are necessary to develop for shoulder reconstruction.

  • PDF

Free jejunal graft for replacement of cervical esophagus (유리 장 이식편을 이용한 식도 재건)

  • Lee, Hong-Seop;Lee, In-Seong;Kim, Chang-Ho
    • Journal of Chest Surgery
    • /
    • v.17 no.4
    • /
    • pp.775-779
    • /
    • 1984
  • Reconstruction of the pharynx and cervical esophagus is a difficult surgical problem. A successful case of reconstruction of cervical esophagus by free jejunal graft upon a 23-year-old female who had stricture in the pharynx and cervical esophagus after ingestion of hydrochloric acid is presented. This procedure was done after the primary traditional reconstruction with right sided colon had resulted in restenosis due to necrosis of the cervical portion of the graft. A proximal jejunal segment, about 12 cm in length was isolated for free graft preserving its vascular arcade. Both superior thyroid artery and vein were anastomosed to the graft vessels in end to end by continuous suture of 8-0 monophil. Nylon. The postoperative course was uneventful. The patient has been followed for 4 months after operation and she can eat every kind of food without dysphagia. We think free jejunal graft offers an excellent and safe method of reconstructing cervical esophagus and pharynx with definitive advantages over other traditional techniques.

  • PDF

Modified drainage of submasseteric space abscess

  • Choi, Moon-Gi
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.43 no.3
    • /
    • pp.197-203
    • /
    • 2017
  • Once a submasseteric space infection is diagnosed, the key to resolving the infection is via surgical intervention to evacuate the pus. Although it is possible and occasionally practical to drain the submasseteric space via an intraoral approach, an extraoral approach may sometimes be required. Surgeons have encountered complications such as facial nerve damage during extraoral incision and drainage procedures, and they have felt that extraoral dissection was very difficult. As such, an easier and simpler technique is needed. Our department recently modified various drainage techniques for submasseteric space abscesses. Damage to the marginal branch of the facial nerve did not occur, and this technique was very simple and rapid, such that a novice physician could perform this procedure. This modified technique was possible with trismus and under local anesthesia. After intraorally checking the position of the drain, the intraoral wound is closed with an absorbable suture and the drain is fixed to the extraoral skin. When a masseteric space infection is diagnosed, multiple space involvement is ruled out, and dependent drainage is required, this modified drainage technique can be useful.

Left Atrium Rupture after Left Pneumonectiomy Using Autostapler -A Case Report- (자동봉합기를 이용한 전폐절제술후 발생한 좌심방 파열)

  • 배기만
    • Journal of Chest Surgery
    • /
    • v.27 no.5
    • /
    • pp.418-421
    • /
    • 1994
  • The usage of autosuture instruments and techniques in resection of bronchovascular structures gained increasing acceptance amongst surgeons in the recent years. The manipulation of these devices are simple, safe, and shortens operating time by avoiding numerous ties and sutures. We have been using autosuture instruments in most of pulmonary resections in Yongdong Severance hospital, and had a satisfactory results. However, we recently have experienced post-pneumonectomy rupture of left pulmonary vein on postoperative one day where the rupture site was in the border of left atrium and left pulmonary vein where the stapler was fired. The patient underwent emergency operation to control massive bleeding and successfully managed by left atrial suture.

  • PDF

Simple Interrupted Suturing for Aortic Valve Replacement in Patients with Severe Aortic Stenosis

  • Lee, Jun Oh;Lee, Chee-hoon;Kim, Ho Jin;Kim, Joon Bum;Jung, Sung-Ho;Joo, Suk Jung;Chung, Cheol Hyun;Lee, Jae Won
    • Journal of Chest Surgery
    • /
    • v.53 no.6
    • /
    • pp.332-338
    • /
    • 2020
  • Background: Attaining an adequate effective orifice area (EOA) is definitive goal in aortic valve replacement (AVR). The simple interrupted suture (SIS) technique could be a solution to achieve this goal, but limited data are available in the literature. This study aimed to compare hemodynamic differences between the SIS and non-everting mattress suture (NMS) techniques. Methods: From our database, 215 patients who underwent AVR for severe aortic stenosis were extracted to form the overall cohort. From March 2015 to November 2016, the SIS technique was used in 79 patients, while the NMS technique was used in 136 patients. Hemodynamic outcomes were evaluated, as detected by transthoracic echocardiography and computed tomography. Results: There were no significant differences in baseline characteristics between the 2 groups. On immediate postoperative echocardiography, the SIS group showed a significantly wider EOA (1.6±0.4 vs. 1.4±0.5 ㎠, p=0.007) and a lower mean pressure gradient (PG) (13.3±5.4 vs. 17.0±6.0 mm Hg, p<0.001) than the NMS group. On follow-up echocardiography, the SIS group continued to have a wider EOA (1.6±0.4 vs. 1.4±0.3 ㎠, p<0.001) and a lower mean PG (11.0±5.1 vs. 14.1±5.5 mm Hg, p<0.001). There was no significant difference in paravalvular leakage. Conclusion: The SIS technique for AVR was associated with a wider EOA and a lower mean PG. The SIS technique could be a reasonable option for AVR.

Effect of Sternal Closure Method on Sternal Dehiscence With or Without Infection (흉골 봉합 방법이 흉골 열개 및 감염에 미치는 영향)

  • 이삼윤;박권재;고광표;최종범
    • Journal of Chest Surgery
    • /
    • v.34 no.6
    • /
    • pp.485-489
    • /
    • 2001
  • Background: The most important factor in preventing sternal complications is stable sternal approximation. We have tried to find the most effective sternal closure method by examining the incidence of sternal dehiscence with or without infection in patients with cardiac surgery through median sternotomy. Material and Method: This study was performed in 489 patients over 45 years of age with median sternotomy for open cardiac surgery. Simple closure with interrupted 6 wires was performed in 159 patients, figure-of-8 closure technique in 119, overlapping interrupted closure using 10 wires in 150, and combined closure technique of interrupted simple closure and figure-of-8 suture closure in 61. Two hundred thirty-four patients underwent valve and aortic operations and 213 patients coronary artery bypass surgery. Result: Sternal dehiscence with or without infection occurred in 12 (2.5 %) patients. The complication developed in 5 of 159 patients (3.1%) with six interrupted simple closure, in 4 of 119 patients (3.4%) with figure-of-8 closure, and in 3 of 150 patients (2.0%) with overlapping interrupted closure using 10 wires, but there was no complication in 61 patients with combined closure technique (relative risk for other closure techniques, p<0.05). There was no significant difference in the incidence of the sternal complication between valve and aortic operation group and coronary artery bypass group (3.0% vs 2.3%, not significant), but diabetes mellitus was a significant independent risk factor (odds ratio and multivariate analysis, p<0.05). Conclusion: The sternal closure technique that combines simple interrupted suture closure and figure-of-8 suture closure may be a more useful technique to enhance sternal stabilization compared to other closure techniques, such as simple interrupted closure, 8-figure closure, and overlapping interrupted closure.

  • PDF