• Title/Summary/Keyword: suture material

Search Result 101, Processing Time 0.024 seconds

A Case of Bladder Stone and Vesicovaginal Fistula after McDonald Operation (자궁경부봉축술 후 발생한 방광석 및 방광질루 1 예)

  • Yoon, Chang-Jun;Moon, Ki-Hak;Jung, Hee-Chang
    • Journal of Yeungnam Medical Science
    • /
    • v.23 no.1
    • /
    • pp.108-112
    • /
    • 2006
  • The frequency of a bladder foreign body in the female is lower than in the male, and bladder stones attached to foreign bodies such as non-absorbable suture material are not common. Moreover, vesicovaginal fistulas due to migration or puncture of suture materials into the bladder are rare. In this report, we present a case of bladder stone and vesicovaginal fistula formation in a 29-year-old female patient who had been treated with the McDonald operation for an incompetent internal os of the cervix (IIOC) during pregnancy. The patient was successfully treated by cystoscopic removal of the bladder stone with suture material and conservative treatment for the vesicovaginal fistula.

  • PDF

TISSUE HEALING RESPONSE OF INCISED WOUND SUTURED BY STAPLES AND VARIOUS SUTURE MATERIALS (Staple과 수종의 봉합물의 봉합부위 창상치유 조직반응)

  • Suh, Min-Jung;Lee, Jae-Hun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.18 no.3
    • /
    • pp.500-514
    • /
    • 1996
  • The purpose of this study was to observe the tissue response in applying staples and various suture materials to both scalp and buccal mucosa in rabbits. 18 rabbits were divided into 6 groups. The incised wounds of both scalp and buccal mucosa were sutured with staples, polyglactin 910, chromic catgut, mer silk and nylon. The experimental animals were sacrificed after 1, 3, 5, 7, 10, 14 days posto peratively 3 animals at one time. The tissue was stained with Hematoxylin and eosin, and Masson's Trichrom. In light microscopic examinations, the sutured sites were examined histologi cally according to 6 degrees about inflammation and collagen deposit. The results were obtained as follows, 1. The chromic catgut, an absorbable suture material, was absorbed by 7 days, whereas polyglactin 910 and mersilk began to get absorbed after 7 days. 2. Mersilk manifested a broad range of inflammation in the scalp, and both staple and nylon showed a severe inflammatory reaction in the buccal mucosa. 3. With polyglactin 910, both tissue samples showed only minor foreign body reaction, however in the scalp, the process of fibrosis took place compara tively slowly, whereas in the buccal mucosa, it occurred promptly and manifested active fibrosis by 7 days. 4. Mersilk showed widespread a matrix formation in both scalp and buccal mucosa, and showed the most severe inflammatory reaction by 3 days, which did not seem to decrease even after 7 days. 5. Both staple and nylon showed relatively a severe inflammatory reaction, however fibrosis took place rather promptly compared to the other groups. 6. Generally, in the buccal mucosa fibrosis occurred more promptly than in the scalp in both control and experimental groups. 7. Retention of the suture material and stability of the knot were the best with the staple, and better stability was manifested by the multi-stranded poly glactin 910 and mersilk than singlestranded chromic catgut and nylon. From above results, in the buccal mucosa absorbable suture materials especially polyglactin 910 showed better response in the aspect of inflammatory reaction, while in the scalp monofilament suture materials such as staple and nylon manifested a early fibrosis and collagen formation.

  • PDF

Pain and quality of life related to suture removal after 3 or 7 days at the extraction sites of impacted lower third molars

  • Rodanant, Pirasut;Wattanajitseree, Kannika;Shrestha, Binit;Wongsirichat, Natthamet
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.16 no.2
    • /
    • pp.131-136
    • /
    • 2016
  • Background: This study aimed to evaluate the patient's pain and quality of life after suture removal at either 3 or 7 days following the bilateral surgical extraction of impacted lower third molars. Methods: This study was a prospective, randomized controlled clinical trial carried out in 30 patients, who acted as their own control. Each patient required the bilaterally impacted mandibular third molars to be extracted. The impacted teeth were removed and the wound margins were approximated and sutured with black braided silk. The suture material was removed on day 3 on one side and on day 7 on the other. Each participant was asked to complete a questionnaire after the removal of the suture material on each designated day. Results: Regarding overall clinical symptoms, the mean VAS scores of male and female participants on day 3 were not significantly different from those on day 7. A significant difference was found in female participants, in that overall daily activity was better on day 7. There were significant differences in the ability to smile and laugh in both sexes and the ability to chew in the male participants was better on day 7. Conclusions: There were no significant differences in the patient's pain and quality of life between suture removal on day 3 or on day 7 following surgery to remove impacted lower third molars.

Treatment of Achilles Tendon Rupture with Absorbable Suture (흡수성 봉합사를 이용한 아킬레스건 파열의 치료)

  • Kang, Chan;Hwang, Deuk-Soo;Hwang, Jung-Mo;Song, Jae-Hwang;Shin, Byung-Kon;Park, Jong-Hwa
    • Journal of Korean Foot and Ankle Society
    • /
    • v.18 no.3
    • /
    • pp.115-118
    • /
    • 2014
  • Purpose: The purpose of this study is to report on the result of repairing Achilles tendon using absorbable suture under nerve block. Materials and Methods: We retrospectively reviewed 20 patients with acute Achilles tendon rupture who were followed up for at least six months after the operation. We repaired Achilles tendon using two absorbable sutures using the Krackow technique for the proximal stump and the Kessler technique for the distal stump. A programmed postoperative management including non-weight bearing with a short leg cast for four weeks after the operation was applied for all patients. We evaluated clinical results using American Orthopaedic Foot and Ankle Society (AOFAS) ankle-hindfoot score, visual analogue scale (VAS) for satisfaction, range of motion of ankle, functional recovery rate, and the starting time of single heel raise. Results: The mean VAS score for satisfaction and AOFAS score was 9.2 and 93.0, respectively. The affected ankle showed a mean dorsiflexion rate of 90% and plantar-flexion rate of 94% compared to the uninjured side. The single heel raise could start at a mean of 3.5 months after the operation. Conclusion: Treatment of Achilles tendon rupture with absorbable suture material using the hybrid suture technique of proximal Krackow and distal Kessler showed sufficient stability and minimal chronic inflammatory reaction.

In-vitro and in-vivo Behaviors of Poly(glycolide-caprolactone) Copolymer for Bioabsorbable Suture Materials

  • Yoo, Yeon-Chun;Kim, Hak-Yong;Jin, Fan-Long;Park, Soo-Jin
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.12
    • /
    • pp.4137-4140
    • /
    • 2012
  • A novel bioabsorbable suture material, poly(glycolide-caprolactone) (PGLCL) monofilament, was prepared by spinning of the PGLCL copolymer. The physical properties, strength retention, biocompatibility, and organism resolvability of the PGLCL monofilament were investigated. The results showed that the knot pull strength of the monofilament was higher than that stated in European Pharmacopoeia. The in vivo retention strength following implantation was 64%, 23%, 7%, and 0% after one, two, three, and four weeks, respectively. Mortality, clinical signs, validation, and sterility tests indicated that all items had passed. Organism resolvability tests showed that the PGLCL monofilament, as a suture, was absorbed within 91 days.

Barbed sutures versus conventional tenorrhaphy in flexor tendon repair: An ex vivo biomechanical analysis

  • Colak, Ozlem;Kankaya, Yuksel;Sungur, Nezih;Ozer, Kadri;Gursoy, Koray;Serbetci, Kemal;Kocer, Ugur
    • Archives of Plastic Surgery
    • /
    • v.46 no.3
    • /
    • pp.228-234
    • /
    • 2019
  • Background The management of flexor tendon injuries has evolved in recent years through industrial improvements in suture materials, refinements of repair methods, and early rehabilitation protocols. However, there is no consensus on the ideal suture material and technique. This study was conducted to compare the tensile strength, repair time, and characteristics of 4-strand cruciate, modified Kessler, and 4-strand horizontal intrafiber barbed sutures for flexor tenorrhaphy with a 12-mm suture purchase length in an animal model. Methods The right third deep flexors of 60 adult Leghorn chicken feet were isolated and repaired with a 12-mm suture purchase length. The tendons were randomly assigned to three groups of equal number (n=20 each). Groups 1 and 2 received 4-strand cruciate and modified Kessler repair with conventional suture materials, respectively. A 4-strand horizontal intrafiber barbed suture technique was used in group 3. The repaired tendons were biomechanically tested for tensile strength, 2-mm gap resistance, and mode of failure. Repair times were also recorded. Results The maximum tensile strength until failure was $44.6{\pm}4.3N$ in group 1, $35.7{\pm}5.2N$ in group 2, and $56.7{\pm}17.3N$ in group 3. The barbed sutures were superior to the other sutures in terms of the load needed for 2-mm gap formation (P<0.05). Furthermore, the barbed sutures showed the shortest repair time (P<0.05). Conclusions This study found that 4-strand horizontal intrafiber barbed suture repair with a 12-mm purchase length in a chicken flexor tendon injury model showed promising biomechanical properties and took less time to perform than other options.

Evaluation of tensile strength of surgical synthetic absorbable suture materials: an in vitro study

  • Khiste, Sujeet Vinayak;Ranganath, V.;Nichani, Ashish Sham
    • Journal of Periodontal and Implant Science
    • /
    • v.43 no.3
    • /
    • pp.130-135
    • /
    • 2013
  • Purpose: The purpose of this study was to evaluate the tensile strength of surgical synthetic absorbable sutures over a period of 14 days under simulated oral conditions. Methods: Three suture materials (polyglycolic acid [PGA], polyglactin [PG] 910, and poly (glycolide-co-${\epsilon}$-caprolactone) [PGC]) were used in 4-0 and 5-0 gauges. 210 suture samples (35 of each material and gauge) were used. All of the samples were tested preimmersion and 1 hour and 1, 3, 7, 10, and 14 days postimmersion. The tensile strength of each suture material and gauge was assessed. The point of breakage and the resorption pattern of the sutures were also assessed. Results: During the first 24 hours of immersion, all 4-0 and 5-0 samples of PGA, PG 910, and PGC maintained their initial tensile strength. At baseline (preimmersion), there was a statistically significant (P<0.001) difference in the tensile strengths between the 4-0 and 5-0 gauge of PGA, PG 910, and PGC. PGA 4-0 showed the highest tensile strength until day 10. At 7 days, all the 4-0 sutures of the three materials had maintained their tensile strength with PGA 4-0 having significantly greater (P=0.003) tensile strength compared to PG. Conclusions: 4-0 sutures are stronger and have greater tensile strength than 5-0 sutures. The PGA 4-0 suture showed the highest tensile strength at the end of day 10.

Reliability of Early Ambulation after Intradural Spine Surgery : Risk Factors and a Preventive Method for Cerebrospinal Fluid Leak Related Complications

  • Lee, Subum;Cho, Dae-Chul;Kim, Kyoung-Tae;Lee, Young-Seok;Rhim, Seung Chul;Park, Jin Hoon
    • Journal of Korean Neurosurgical Society
    • /
    • v.64 no.5
    • /
    • pp.799-807
    • /
    • 2021
  • Objective : Cerebrospinal fluid leakage related complications (CLC) occasionally occur after intradural spinal surgery. We sought to investigate the effectiveness of early ambulation after intradural spinal surgery and analyze the risk factors for CLC. Methods : For this retrospective cohort study, we enrolled 314 patients who underwent intradural spinal surgery at a single institution. The early group contained 79 patients who started ambulation after 1 day of bedrest without position restrictions, while the late group consisted of 235 patients who started ambulation after at least 3 days of bed rest and were limited to the prone position after surgery. In the early group, Prolene 6-0 was used as the dura suture material, while black silk 5-0 was used as the dura suture material in the late group. Results : The overall incidence rate of CLC was 10.8%. Significant differences between the early and late groups were identified in the rate of CLC (2.5% vs. 13.6%), surgical repair required (1.3% vs. 7.7%), and length of hospital stay (2.99 vs. 9.29 days) (p<0.05). Logistic regression analysis revealed that CLC was associated with practices specific to the late group (p=0.011) and the revision surgery (p=0.022). Conclusion : Using Prolene 6-0 as a dura suture material for intradural spinal surgery resulted in lower CLC rates compared to black silk 5-0 sutures despite a shorter bed rest period. Our findings revealed that suture - needle ratio related to dura defect was the most critical factor for CLC. One-day ambulation after primary dura closure using Prolene 6-0 sutures appears to be a costeffective and safe strategy for intradural spinal surgery.

Surgical Treatment of Achilles Tendon Rupture with Absorbable Suture Materials Only (흡수성 봉합사만를 이용한 아킬레스건 파열의 수술적 치료)

  • Bae, Su-Young;Park, Jae Gu;Jung, Eui Yub
    • Journal of Korean Foot and Ankle Society
    • /
    • v.17 no.3
    • /
    • pp.196-202
    • /
    • 2013
  • Purpose: To report the clinical results from using absorbable suture materials instead of nonabsorbable materials which have been used more commonly to repair Achilles tendon. Materials and Methods: We retrospectively reviewed 21 cases of acute Achilles tendon rupture, treated surgically from 2004 to 2011. Mean follow-up period is 6 months. We repaired Achilles tendon using size 1 Vicryl (Polyglactin 910, Ethicon) for core suture and size 3-0 Vicryl for epitendinous suture. At three months after surgery, we evaluated clinical results with single heel raise height by centimeters, differences of calf circumference and passive range of motion of ankle joint, compared to contralateral side. Also we recorded clinical results with subjective satisfaction grades. Results: At three months after surgery, 20 of 21 patients were able to perform single heel raise over 5 cm in height. Calf circumference differences were less than 1 cm in 12 cases, between 1 cm to 3 cm in 5 cases, more than 3 cm in 4 cases. There was no difference in range of passive motion in 19 cases. All patients satisfied with daily activity except 2 cases with mild discomfort. There was no complication such as rerupture, elongation or infection. Conclusion: We experienced excellent clinical results from repairing Achilles tendon with using absorbable suture materials in terms of functional outcomes and patient's satisfaction without any complication. So we may consider using absorbable suture materials instead of nonabsorbable materials to repair Achilles tendon.

AN EXPERIMENTAL STUDY OF TISSUE REACTION OF ABSORBABLE SUTURE MATERIALS (수종(數種)의 흡수성(吸收性) 봉합사(縫合絲)가 조직반응(組織反應)에 미치는 영향(影響)에 관(關)한 실험적(實驗的) 연구(硏究))

  • Song, Sun-Chul;Kim, Kyung-Wook
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.13 no.4
    • /
    • pp.381-390
    • /
    • 1991
  • The purpose of this study was to select the absorbable suture material with the lowest level of foreign body reaction in the extraoral field. The absorbable sutures tested were polyglactin 910(Vicryl), polyglycolic acid(Dexon), and chromic gut. Black silk served as to control suture. Eighteen domestic rabbits served as the animal model for testing purposes. After shaving the fur, A six centimeter incision was made in the hind quarter of all eighteen animals. Each wound was then closed wit two Vicryl, two Dexon, and two chromic gut sutures. All wounds were closed in the same manner. A similar wound was made on the oppsite side and closed with black silk suture. Three rabbits were then sacrificed on postoperative day one, three, seven fourteen, twenty-one, and twenty-eight. The surgical sites were then examined histologically. 1. On days one, three, and seven all suture materials as a similar severe level of inflammatory response. On the fourteenth day the inflammatory reaction of Vicryl was minimal, chromic gut was moderate, and Dexon was severe, Black silk control groups demosnstrated the most severe levels of inflammation of all sutures tested from day fourteen to twenty-eight. 2. On the fourteenth day all absorbable suture materials demonstrated similar minimal levels of resorption. At twenty-eight days Vicryl demonstrated a greater amount of resorption than Dexon or cromic gut suture. There was no resorption noted in the black silk control groups through day twenty-eight. 3. Due to its decreased level of inflammatory response in the animal model, Vicryl might be expected to as a decreased level of response in humans. It is felt that Vicryl is preferred to Dexon or chromic gut for extraoral suturing.

  • PDF