• Title/Summary/Keyword: suture material

Search Result 101, Processing Time 0.02 seconds

Comparison of Tracheal Anastomosis by Interrupted and Continuous Technique of Absorbable polydioxanone (PDS) Suture Material in Rabbit (가토에서 흡수성 PDS 봉합사의 단속봉합술식과 연속봉합술식에 따른 기관문합의 비교)

  • 이석열;양성린;이길노
    • Korean Journal of Bronchoesophagology
    • /
    • v.7 no.1
    • /
    • pp.9-13
    • /
    • 2001
  • Background: Tracheal resection and end-to-end anastomosis are the preferred treatment for tracheal tumor or tracheal stenosis. Absorbable suture material has been commonly used in case of tracheal anastomosis. But anastomosis technique is controversial. This experimental study compared between interrupted suture and continuous suture using Polydioxanone (PDS) absorbable suture material after tracheal resection and end-to-end anastomosis in rabbits. Methods : Twenty-four rabbits were used, divided into two groups of 12 animals each. The trachea was resected and then anastomosed with continuous 6-0 polydioxanone (PDS) (group 1), and intermittent 6-0 polydioxanone (PDS) (group 2). The animals were followed up for 6 months. Stenosis of the trachea was assessed at the time of death. Results : In two groups, anteroposterior diameter, transverse diameter, cross sectional area, and perimeter were greater in group 2 than in group 1 but, not significantly different. In addition, histologic findings were not different in two groups. Conclusions : This study suggest that stenosis after tracheal resection and end-to-end anastomosis using absorbable polydioxanone (PDS) suture material be not significantly different in both groups.

  • PDF

Surgical Treatment of Ahilles Tendon Rupture Using Modified Lynn Method (변형 Lynn씨 방법에 의한 아킬레스건 파열의 수술적 치료)

  • Kang, Jae-Do;Kim, Kwang-Yul;Kim, Hyung-Chun;Kim, Jin-Hyung;Choi, Shin-Kwon
    • Journal of Korean Foot and Ankle Society
    • /
    • v.7 no.2
    • /
    • pp.223-231
    • /
    • 2003
  • Purpose: Achilles tendon rupture has become more common in the recent years. As suture with foreign material has been blamed for impaired healing, better results should be expected from the use of autogenous material such as plantaris tendon. We have evaluated the surgical results of end-to-end anastomosis using the plantaris tendon as suture material. Materials and Methods: Between Jan 1997 and Jan 2002, the 60 patients were included this study during one year follow-up. We performed the operations with end-to-end suture technique using modified Lynn's method. The plantaris tendon has been used as a autogenous suture material and can be utilized in the end-to-end anastomosis of ruptured Achilles tendon with modifed Bunnel suture technique. We used a clinical scoring system reported by Leppilahti to evaluate the results. Results: The overall results were excellent in thirty eight(63.3%), good in sixteen(26.6%), fair in five(8.3%) cases, and poor in only one (1.6%) case. Fifty four cases(90%) had the score more than good. We had no deep infection, rerupture, deep vein thrombosis, and skin necrosis as major complication. In just 2 cases, although there were superficial skin infection, the wounds did not proceed necrosis due to using antibiotics. Conclusion: End-to-end anastomosis using the plantaris tendon as suture material was good treatment option that had low infection rate and no foreign body reaction because of using autogenous material, and therefore we can get rapid healing of ruptured tendon due to early ragne of motion and accerlerated rehabilitation.

  • PDF

A Histopathological Study on Suture Granuloma in Neutralized Dogs (개에서 거세 후 발생한 봉합사 육아종의 병리조직학적인 연구)

  • Park, Chun-Ho;Kwon, Young-Sam;Isomura, Hiroshi
    • Korean Journal of Veterinary Research
    • /
    • v.42 no.3
    • /
    • pp.419-423
    • /
    • 2002
  • Postoperative suture granuloma have rarely been reported in animals. Eight biopsy masses from testes areas of neutralized dogs were diagnosed as suture granuloma. The suture granuloma occurred at any time from several weeks to a few years after surgery and appeared to be testicular tumors by macroscopic examination. The granulomas were classified into three types based on the histopathological findings. The first type of pyogranuloma was mainly composed of neutrophils, macrophages, and suture fragments. The second type was chronic necrotizing granuloma which was well demarcated by fibrous connective tissues and was composed of a few suture fragments, macrophages and central fibrinoid necrosis. The third type of granuloma had a poorly defined margin with scarcely observed suture fragments and central necrosis in the tissue. These histopathological findings suggested that various types of suture granuloma may be caused by suture material and could even appear long after surgery.

Fixation with Absorbable Suture Material in Akin Osteotomy (흡수성 봉합사를 이용한 무지외반증 Akin 절골술)

  • Song, Moo-Ho;Kim, Bu-Hwan;Ahn, Seong-Jun;Yoo, Seong-Ho;Lee, Doo-Jae
    • Journal of Korean Foot and Ankle Society
    • /
    • v.15 no.3
    • /
    • pp.149-152
    • /
    • 2011
  • Purpose: The Akin osteotomy which is a closing wedge osteotomy of the proximal phalanx widely used for the correction of hallux valgus has several methods of fixation. we tried to report the effects of the fixation using an absorbable suture material during the Akin osteotomy for the hallux valgus. Materials and Methods: This study was based on 448 cases of 346 patients who were able for follow-up more than 12 months among the patients who had an Akin osteotomy together with the surgery of hallux valgus between March of 2006 and May of 2010. Absorbable suture material had been used in all cases. Radiologically displacement and union of osteotomy site were observed after the surgery, and clinically postoperative complication such as skin irritation, pain and satisfaction were investigated. Results: Radiologically all cases had showed complete union and no case had the loss of an correction due to loss of fixation. Also, any case had no skin irritation due to a knot. Three cases had a medial cortical breakage due to a strong knot, and the initial one case among them had additionally fixed the osteotomy site for four weeks using K-wire, and the remaining two cases had fixed a suture on an articular surface without any fixation of an additional wire. If a medial cortical bone was lost by carrying out an ostectomy due to proximal protrusion of proximal phalanx, three cases could show union through the fixation of suture on an articular surface. Conclusion: This study considers that the fixation of the osteotomy site using an absorbable suture material in an Akin osteotomy was effective method and the advantage of this procedure was unnecessity of the material removal and no skin irritation.

Changes of Tracheal Anastomosis Site in Growing Rats (흰쥐에서 기관절제 단단 문합부의 성장에 따른 변화)

  • 박희철
    • Journal of Chest Surgery
    • /
    • v.26 no.5
    • /
    • pp.343-348
    • /
    • 1993
  • Growth of suture line and anastomosis is required for long-term success after the tracheal and bronchial surgery in infant and pediatric patient. We used various suture materials in these cases, but the results were differ. To select the adequate suture material in tracheal surgery, we tried next. Tracheal anastomoses were performed in 150 Sprague Dawley rats, aged 4 to 8 [mean 5.8] weeks and weight 62 to 106[mean 83.6] gram, to compare polydioxanone[PDS] 7-0, polyglactin 910[Vicryl]7-0, and polypropylene [prolene] 8-0 suture materials. In 150 rats, only 29[20%] were lived over 300 days, and the weight was 250 to 320[mean 289.5]gram. Cross sectional area of the anastomoses and two or three tracheal rings below anastomosis site were measured under microscope, and calculated and compared as Hsieh`s equition. Cross-sectional area,anastomosis site/normal site 100, were 89.4 $\pm$ 5.34% in PDS group[n=9], 75.7 $\pm$ 6.06% in Vicrylgroup [n = 10], and 80.8$\pm$ 4.06% in Prolene group[n = 10]. Histopathologic studies were done for all autopsies or put in death around 300 days postoperatively. PDS absorblion was not seen 16 weeks after suture but disappeared over 24 weeks slide. Vicryl absorbtion was noted postoperative 8 to 16 weeks, with marked tissue reaction. Prolene showed least tissue reaction, but the suture material was persisted with regional fibrotic capsule.Causes of death were respiratory failure in 76 cases, tracheal rupture in 22 cases, hemorrhage, biting, starvation and etc. in 23 cases. With the brief review of literatures, we report the results.

  • PDF

Retroperitoneal Suppurative Fistula Caused by Remnant Suture Material in a Poodle Dog

  • Kim, Keunyung;Lee, Chaeyeong;Kim, Minyeon;Choi, Hyeonjong;Hong, Jeongho;Kim, Hyoyeon;Park, Hyojin;Kim, Na-hyun;Lee, Dongbin;Lee, Jae-Hoon
    • Journal of Veterinary Clinics
    • /
    • v.38 no.6
    • /
    • pp.285-289
    • /
    • 2021
  • An eight-year-old, 3.4 kg, spayed female poodle dog was referred to Gyeongsang National University Animal Medical Center with obstinate bilateral retroperitoneal subcutaneous abscess. The medical history revealed ovariohysterectomy (OHE), lipoma, and mammary gland tumor excision performed two years ago. The dog presented with left retroperitoneal subcutaneous abscess discharge five months back and was treated by abscess drainage and antibiotics in a local veterinary hospital, but a relapse was reported on discontinuing antibiotics. On physical examination, the dog was febrile (40℃) and both retroperitoneal masses showed typical inflammatory reaction and purulent discharge. On serum chemistry analysis, hyperproteinemia, hyperglobulinemia, and elevated levels of C-reactive protein were observed. Cytologic examination showed degenerative neutrophils and phagocytic macrophages. Radiological examination revealed encapsulated hypoechoic subcutaneous masses in bilateral abdominal flank and the left flank mass was connected with the caudal pole of left kidney through fistula. Based on the diagnostic examination, exploratory celiotomy was recommended and left nephrectomy, and resection of bilateral masses were performed. During procedure, fistula between caudal pole of left kidney and left subcutaneous abscess was detected and suture material was identified. Resected tissue was histologically examined and diagnosed as suppurative abscess caused by the suture material. This case report describes chronic suppurative foreign body reaction including caudal pole of left kidney and bilateral retroperitoneal subcutaneous masses induced by the suture material used in OHE two years ago and the necessity of computed tomography examination to identify character of mass and extent of surgical resection.

Fixation with Suture Material in Akin Osteotomy (봉합사 고정을 이용한 Akin 절골술)

  • Young, Ki-Won;Lee, Kyung-Tai;Kim, Jae-Young;Cha, Seung-Do;Kim, Eung-Soo
    • Journal of Korean Foot and Ankle Society
    • /
    • v.8 no.2
    • /
    • pp.138-141
    • /
    • 2004
  • Purpose: The purpose of this study was to document the results of fixation with ethibond suture in akin osteotomy and its advantages. Materials and Methods: From May 2001 to January 2004, Akin osteotomy was performed in 218 patients. We reviewed 110 patients (114 feet) who were possible radiographic evaluation more than 6 months after operation. 110 feet had hallux valgus and 4 feet had hallux valgus interphalangeus. 105 patients were female and 5 were male. The average age was 43.8 years old (18 to 68 years old). The average follow up was 9 months (6 to 23 months). After performing the Akin osteotomy at 7 mm from the proximal articular surface of the proximal phalanx, one hole is made on either side of the osteotomy site with a K-wire. The passer was passed through the both holes and the ethibond was passed. And then, the ethibond was tied tightly. 2 sutures in 66 feet and 1 suture in 48 feet were made. Radiographic bone union at 6 months follow up was regarded as success and loss of the reduction, nonunion was regarded as failed. Results: In the radiographic evaluation, bony union were made at 6 months follow up in all feet. There was no difference between 2 sutures and 1 suture, and the knots were removed in 3 feet because of skin irritation. Conclusion: The fixation of the osteotomy site using suture material was an effective method in Akin osteotomy. The advantage of this procedure was unnecessity of the material removal.

  • PDF

The Effect of Indwelling Silk Suture Material Following Aspiration in the Treatment of Chronic Prepatellar Bursitis (흡인 후 견 봉합사 거치를 통한 만성 슬개골전 점액낭염의 치료)

  • Lee, Bong-Jin;Lee, Sung-Rak;Kim, Chung-Hyun;Kim, Seong-Tae
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.4 no.1
    • /
    • pp.55-59
    • /
    • 2005
  • Purpose: To evaluate the drainage effect of silk suture material following aspiration of the bursa as an early treatment of chronic prepatellar bursitis. Materials and Methods: Twelve cases, which have over two weeks of history and over one year of follow-up, were investigated. The average duration of follow-up was 18.3 months. The average symptom duration before introduction into this study was 2.2 months. With an aseptic technique, the aspiration of the bursa was done with spinal needle or injection needle and syringe and then the insertion of silk suture material through the aspiration needle was performed. Over one year follow-up, recurrence, infection, pain, and limitation of range of motion were investigated by telephone interview. Results: Redness around the insertion site of silk suture material was found in all cases, but there was no development of active infection in eleven cases. At five days after procedure, a supprative infection was developed in one case. The results were considered satisfactory in 92% of cases and the average duration of treatment is 14.5 days. Conclusion: The drainage with silk suture material following aspiration of the bursa is effective and less invasive method in the early treatment of chronic prepatellar bursitis.

  • PDF

The Mechanical Appearances and Microscopic Tissue Reactions of the Suture Materials in vivo (생체내 이식된 흡수성 봉합사들의 물리적 성질 변화와 조직 소견에 관한 연구)

  • 김남중;김명철
    • Journal of Veterinary Clinics
    • /
    • v.13 no.2
    • /
    • pp.184-194
    • /
    • 1996
  • A comparative study of three absorbable suture materials of chromic catgut, Dexon II (a polyglycolic acid suture with a polycaprolate coating system) and Coated Vicryl (a polyglactin 910 suture with a glycolide-lactide-calcium stearate coating system) was undertaken in terms of tensile strength, breaking elongation, appearances of the suture materials in the subcutaneous layer of rats and of tissue reaction in the intramuscular layer of rats. The initial tensile strength of chromic catgut and the tensile strength after 21 days were about 1.55 kg and 0.19 kg, respectively. Those of Dexon II were about 2.01 kg and 0. 20 kg, respectively. Those of Coated Vicryl were about 2.39 kg and 0.48 kg, respectively. Coated Vicryl showed the highest tensile strength among the three materials during the whole period. On the other hand, Dexon II showed the highest breaking elongation among the three materials during the first week. But the breaking elongation of Dexon II rapidly continuously decreased during the whole period. The appearances of the suture materials in the subcutaneous layer of rats showed that chromic catgut was the fastest among the three materials, whereas it formed comparatively much connective tissue. The intramuscular absorption rate and tissue reaction of Dexon II were similar to those of Coated Vicryl. The intramuscular absorption rate of these was fairly late when compared with chromic catgut. And the tissue reaction appearance of these showed the formation of a granuloma with foreign body giant cells, macrothages and epitheloid cells by the 28th day in the experimental period.

  • PDF