• Title/Summary/Keyword: suture

Search Result 1,068, Processing Time 0.037 seconds

Usefulness of an Additional Mattress Suture for the Extracranial Drainage Catheter

  • Eom, Dong Woong;Kim, Jung Soo;Jeon, Kyoung Dong;Kim, Hoon;Choi, Byeong Sam
    • Journal of Korean Neurosurgical Society
    • /
    • v.54 no.5
    • /
    • pp.444-447
    • /
    • 2013
  • In most intracranial surgery cases, a drain catheter is inserted to prevent the collection of the wound hematoma or seroma. A drain catheter is also inserted to drain the hematoma or the cerebrospinal fluid. The drain catheter itself does not cause complications; but many complications occur during its removal, such as hematoma, seroma, air collection and pseudomeningocele formation. To prevent these complications, neurosurgeons perform a suture on the catheter to remove the site. In this study, an additional horizontal mattress suture and an anchoring suture to the drainage catheter are proposed. This method maintains negative pressure in the catheter insertion site during the catheter removal, compresses the catheter tunnel site and attaches the external wounds strongly. The technique is easy and safe to perform, and does not require an additional suture to remove the catheter.

The Effect of Indwelling Silk Suture Following Aspiration in the Treatment of Chronic Olecranon Bursitis (흡입 후 견 봉합사 거치를 통한 만성 주두 점액낭염의 치료)

  • Lee Bong-Jin;Lee Sung-Rak;Kim Seong-Tae
    • Clinics in Shoulder and Elbow
    • /
    • v.8 no.1
    • /
    • pp.31-35
    • /
    • 2005
  • The purpose of this study was to evaluate the drainage effect of silk suture following aspiration of the bursa as an early treatment of chronic olecranon bursitis. Eleven cases, which have over two weeks of history and over one year of follow-up, were investigated. The average duration of follow-up was 17.5 months. The average symptom duration was 1.8 months. With an aseptic technique, the aspiration of the bursa was done with 18gauge needle and syringe and then the insertion of silk suture through the aspiration needle was performed. The amount of drainage was regularly checked $2{\sim}3$ days interval and stitch out was done at the cessation of drainage. At the follow-up, recurrence, infection, pain, and limitation of range of motion were investigated by telephone interview. Redness around the insertion site of silk suture was found in all cases, but there was no active infection or recurrence. The results were satisfactory in all cases and the average time for recovery was 10.5 days. The drainage with silk suture following aspiration of the bursa is less invasive and very effective method in the early treatment of chronic olecranon bursitis.

Treatment of a naso-orbito-ethmoid fracture using open reduction and suspension sutures: a case report

  • Youngsu, Na;Chaneol, Seo;Yongseok, Kwon;Jeenam, Kim;Hyungon, Choi;Donghyeok, Shin;Myungchul, Lee
    • Archives of Craniofacial Surgery
    • /
    • v.23 no.6
    • /
    • pp.269-273
    • /
    • 2022
  • Naso-orbito-ethmoidal (NOE) fractures are complicated fractures of the mid-face. The treatment of NOE fractures is challenging and a comprehensive treatment strategy is required. We introduce a case of NOE fracture treated with open reduction and suspension sutures. A 28-year-old woman presented with a unilateral NOE fracture. To reduce the frontal process of the maxilla, a suspension suture was made by pulling the fragment using a double arm suture via a transcaruncular incision. The suture thread was placed in the horizontal plane. Another suspension suture on the inferior orbital rim assisted reduction procedure, and they passed through the overlying skin. The reduction alignment could be finely adjusted by tightening the transcutaneous suture threads while checking the degree of bone alignment through the subciliary incision. The two suture threads were suspended using a thermoplastic nasal splint. An additional skin incision on the medial canthal area, which would have resulted in a scar, could be avoided. Four months postoperatively, computed tomography showed an accurate and stable reduction. The patient was satisfied with her aesthetic appearance, and functional deficits were not present.

Is the UU Stitch Really Alternative to Modified MA (Mason-Allen) Stitch for Rotator Cuff Repair? - Biomechanical Comparative Study of UU to Modified MA Stitch - (회전근 개 파열의 봉합에서 UU 봉합법은 변형된 MA(Mason-Allen) 봉합법을 대치할 수 있는가? - UU 봉합법과 변형된 MA 봉합법의 생역학적 비교-)

  • Friedman, Darren J;Ko, Sang-Hun;Park, Ki-Bong;Jun, Hyung-Min;Kim, Tae-Won;Lim, Hyun-Woo;Yum, Young-Jin
    • Clinics in Shoulder and Elbow
    • /
    • v.12 no.2
    • /
    • pp.207-214
    • /
    • 2009
  • Purpose: In arthroscopic rotator cuff repairs there are generally weak link in tendon suture interface, arthroscopic rotator cuff repairs can have higher retear rates than open repairs. The purpose of this study was to compare the strength of UU (Ulsan University) suture than open modified MA (Mason-Allen) suture when suture anchored into bone. Materials and Methods: The human supraspinatus tendons were harvested from the shoulder of the cadaver and split in 2 times, producing four tendons per one shoulder, for a total of 24 specimens. Two suture configurations (UU, MA) were randomized and checked on each set of tendons. Specimens were cyclically loaded under force control between 5 and 30 N at 0.25 Hz for fifty cycles. Each specimen was loaded to failure under displacement control at 1 mm/sec. Cyclic elongation, peak to peak displacement, stiffness, ultimate tensile load, mode of failure were checked. Results: No significant difference was found between two suture configuration with respect to peak to peak displacement, cyclic elongation, and stiffness. With regard to ultimate failure load, there were no significant difference statistically between the UU suture and modified MA suture (109.4 N, 110.6 N). The most common mode of failure between both sutures was suture pull-out through the tendon. Conclusion: The UU suture and modified MA suture produced similar biomechanical properties.

The Overlapping Running Suture Method Using Single Knotless Barbed Absorbable Suture Material for Abdominal Wall Closure after Single Incision Laparoscopic Appendectomy: Comparison with the Traditional Interrupted Closure Technique

  • Kim, Dong Hyun;Park, Jung Ho;Joo, Jung Il;Jeon, Jang Yong;Lim, Sang Woo
    • Journal of Minimally Invasive Surgery
    • /
    • v.21 no.4
    • /
    • pp.160-167
    • /
    • 2018
  • Purpose: The aim of our study was to present an abdominal wall closure technique using barbed suture $V-Loc^{TM}$ 90 after single incision laparoscopic appendectomy (SILA) and to compare perioperative outcomes with conventional layer by layer abdominal wall closure after SILA. Methods: From March 2014 to July 2016, a retrospective case-control study was conducted for a total of 269 consecutive patients who underwent SILA. According to abdominal wall closure methods, 129 patients were classified into the V-Loc closure group and 140 patients were assigned into the conventional layer by layer closure group. In the V-Loc group, abdominal wall closure was performed from the fascia to the skin with a single thread of unidirectional absorbable barbed suture $V-Loc^{TM}$ 90 2-0 using continuous running suture and reverse overlapping reinforced running technique. Subcutaneous closure and subcuticular suture were performed with the remaining portion of V-Loc. Results: The V-Loc closure group showed shorter total operation time ($40.0{\pm}15.4min$ vs. $44.9{\pm}16.3min$, p=0.013) and abdominal wall cusing continuous running suture and reverse overlapping reinforced running technique. Subcutaneous closure and subcuticular suture were performed with the remaining portion of V-Loc. Results: The V-Loc closure group showed shorter total operation time losure time ($5.5{\pm}0.9min$ vs. $6.5{\pm}0.8min$, p<0.001). Postoperative incision length was significantly shorter in the V-Loc closure group ($1.1{\pm}0.3cm$ vs. $1.8{\pm}0.4cm$, p<0.001). Postoperative wound pain, time to resume diet, postoperative hospital stay, complications including surgical site infection, or mean patient satisfaction score at one month after hospital discharge was not significantly different between the two groups. Conclusion: In conclusion, unidirectional knotless barbed suture is a safe alternative method for abdominal wall closure after SILA. It can save time while providing comparable cosmesis.

Locking horizontal mattress suture as the alternative closure method for scalp lacerations difficult to suture with staple (두피 봉합기로 봉합하기 어려운 두피 열상에 시행한 잠금 수평 매트리스 봉합법의 유용성 관찰 연구)

  • Sah, Seung Woo;Seol, Seunghwan;Lee, Woon Jeong;Woo, Seon Hee;Kim, Dae Hee;Lee, June Young;In, Sangkook;Kim, Bonggyeom
    • Journal of The Korean Society of Emergency Medicine
    • /
    • v.29 no.6
    • /
    • pp.649-655
    • /
    • 2018
  • Objective: This paper reports the possibility of using of a locking horizontal mattress suture technique in repairing lacerations that are difficult to suture with staples. Methods: Data were collected retrospectively over a 6-month period regarding the routine repair of scalp lacerations: those in areas injured by a high energy blunt mechanism, continued to bleed after pressure, nonlinear or damaged skin repaired with a locking horizontal mattress technique, and simple interrupted technique. The effects of the two techniques used to repair scalp lacerations on wound healing, complication rate, and patient satisfaction were examined. The categorical variables are expressed as the number and percent. A Mann-Whitney-Wilcoxon test was used for statistical analysis. A P-value less than 0.05 was considered significant. Results: Thirty-seven consecutive patients with scalp lacerations presented for care. Wound closure was accomplished with the locking horizontal mattress sutures in 40.5% (n=15) (median length, 5.0 cm; interquartile range [IQR], 4.0-7.0 cm). Simple interrupted sutures (median length, 4 cm; IQR, 3.0-5.0 cm) were used in 59.5% (n=22) (P=0.015). The frequency of additional bandage compression (P=0.008), frequency of exudative hemorrhage (P=0.018), and suture mark frequency at suture removal (P=0.047) were significantly lower in the locking horizontal mattress group. Conclusion: The locking horizontal mattress suture, which has the advantage of a horizontal mattress suture, may be one of the ways that can be used alternatively to treat scalp lacerations that difficult to suture with staples.

Surgical Treatment of Achilles Tendon Rupture with Absorbable Suture Materials Only (흡수성 봉합사만를 이용한 아킬레스건 파열의 수술적 치료)

  • Bae, Su-Young;Park, Jae Gu;Jung, Eui Yub
    • Journal of Korean Foot and Ankle Society
    • /
    • v.17 no.3
    • /
    • pp.196-202
    • /
    • 2013
  • Purpose: To report the clinical results from using absorbable suture materials instead of nonabsorbable materials which have been used more commonly to repair Achilles tendon. Materials and Methods: We retrospectively reviewed 21 cases of acute Achilles tendon rupture, treated surgically from 2004 to 2011. Mean follow-up period is 6 months. We repaired Achilles tendon using size 1 Vicryl (Polyglactin 910, Ethicon) for core suture and size 3-0 Vicryl for epitendinous suture. At three months after surgery, we evaluated clinical results with single heel raise height by centimeters, differences of calf circumference and passive range of motion of ankle joint, compared to contralateral side. Also we recorded clinical results with subjective satisfaction grades. Results: At three months after surgery, 20 of 21 patients were able to perform single heel raise over 5 cm in height. Calf circumference differences were less than 1 cm in 12 cases, between 1 cm to 3 cm in 5 cases, more than 3 cm in 4 cases. There was no difference in range of passive motion in 19 cases. All patients satisfied with daily activity except 2 cases with mild discomfort. There was no complication such as rerupture, elongation or infection. Conclusion: We experienced excellent clinical results from repairing Achilles tendon with using absorbable suture materials in terms of functional outcomes and patient's satisfaction without any complication. So we may consider using absorbable suture materials instead of nonabsorbable materials to repair Achilles tendon.

Microvascular Anastomosis Using 'Continuous Suture with Interrupted Knot' Technique (연속 봉합 단속 결찰법을 이용한 미세 혈관 문합법)

  • Choi, Moon-Su;Park, Sang-Hoon
    • Archives of Reconstructive Microsurgery
    • /
    • v.8 no.1
    • /
    • pp.22-27
    • /
    • 1999
  • While the conventional end-to-end anastomotic technique is accepted as 'the golden standard' for microvascular anastomosis, it is time-consuming and tedious. In an effort to offer faster and safer ways of performing microvascular anastomoses, numerous anastomotic techniques have been proposed, but further refinements in microvascular techniques are still necessary. A 'continuous suture with interrupted knot' technique was devised for faster and safer anastomosis. It has been successfully used in microanastomoses of both artery and vein for free tissue transfer. It is a combination of the interrupted suturing technique and the continuous suturing technique. First, a continuous suture is made with the size of loop decreasing in order, and then the sutures are tied individually from the first loop to the last one as in the conventional interrupted suturing technique. It was applied clinically to fourteen patients over the past ten months and found to be a highly efficient technique that satisfied our needs. This 'continuous suture with interrupted knot' technique has several advantages over other techniques : The operative time is reduced comparing conventional interrupted suture technique. By delaying the tie and with the vessel walls kept separated, the risk of through-stitch can be reduced. Tying all the sutures at one time not only speed up the procedures, but also reduced the surgeon's fatigue. In addition, it has no problem of anastomotic stenosis which is a disadvantage of continuous suture technique. This technique proved to be faster and safer, and has patency equal to that of the conventional end-to-end anastomosis. It is of great help to the surgeon in reducing operative time, especially in clinical situations when many anastomoses are required, or lengthy grafting procedures are undertaken.

  • PDF

Advantages of Scorpion Suture Passer and 70 Degrees Arthroscope in Arthroscopic Bankart Repair: Usefulness for Inferior Labral Repair

  • Hyun, Yoon-Suk;Shin, Woo-Jin
    • Clinics in Shoulder and Elbow
    • /
    • v.20 no.4
    • /
    • pp.201-207
    • /
    • 2017
  • Background: The blunted tip of a reusable with multiple uses can cause problems with the passing procedure in arthroscopic Bankart repair. This study assessed the advantage of Scorpion with a $70^{\circ}$ arthroscope in arthroscopic Bankart repair compared to hook typed suture passer. Methods: Scorpion in 19 patients, the hook type suture passer (conventional group) in 18 patients were used. All patients underwent the same procedure except for the type of suture passer used. Another different point of the procedure were telescopes and the number of portals used; three arthroscopic portals (posterior, anterorsuperiorlateral, and mid-anterior) and a $30^{\circ}$ arthroscope in the conventional group, but two portals and a $70^{\circ}$ arthroscope as well as the $30^{\circ}$ one in the Scorpion group. The surgery time and the surgical complications including an iatrogenic axillary nerve injury were recorded. Results: The Scorpion group showed a significant decrease in surgery time compared to the conventional group. In contrast to the conventional group, Scorpion provided an easy estimation of the exit of suture passing, no iatrogenic labral injury during the passing procedure with straight movement and the sharp tip of the knife installed. Iatrogenic supraspinatus injuries could be avoided when making an accessory anteosuperiorlateral portal due to the $70^{\circ}$ arthroscope. Conclusions: In arthroscopic Bankart repair, the use of the Scorpion suture passer and a $70^{\circ}$ arthroscope can reduce the surgery time, avoid unnecessary supraspinatus injury, and avoid iatrogenic axillary nerve damage through the relatively easy and precise suture passing and saving of the anterosuperior portal.

Interrupted Single-layer Suture Technique in Esophageal Anastomosis Using Monofilament Polypropylene Suture (Monofilament Polypropylene사를 이용한 단속단층 식도문합술)

  • 성시찬;편승환
    • Journal of Chest Surgery
    • /
    • v.31 no.7
    • /
    • pp.711-717
    • /
    • 1998
  • Background: Although various anastomotic techniques and suture materials have been used in esophageal anastomosis, anastomotic leakage and stenosis are still somewhat frequent and serious complications when compared to other intestinal anastomoses. We have used interrupted single-layer suture technique using monofilament polypropylene suture in various esophageal anastomoses, including repair of the esophageal atresia, since 1990. Methods and method: We retrospectively evaluated the efficacy of this technique on postoperative leakage and stenosis in several esophageal reconstructions. The esophageal reconstructions using this technique were performed in 90 patients at Dong-A University Hospital from April 1990 through December 1996. Results: Anastomotic leakage occurred in 5 patients(5.6%) with one operative death. Stenosis at the anastomotic site occurred in 15 patients(n=86, 17.4%), which was most common in esophagogastrostomy(22%) and least common in esophagocolostomy (5%). This result was comparable to other methods including the autosuture technique. Conclusions: We concluded that this suture technique in esophageal anastomosis can be used with reasonable results in various esophageal reconstructions including correction of the esophageal atresia.

  • PDF