• Title/Summary/Keyword: suspension insulator

Search Result 83, Processing Time 0.037 seconds

Development of Cleaning Robot System for Live-line Suspension Insulator Strings in 345kV Power Lines and Its Application (345kV 송전선로 활선 현수애자련 청소로봇 시스템의 개발 및 적용)

  • Park, Joon-Young;Cho, Byung-Hak;Byun, Seung-Hyun;Lee, Jae-Kyung;Park, Doo-Yong
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1769-1770
    • /
    • 2007
  • To prevent an insulator failure, an automatic cleaning robot was developed for suspension insulator strings. The robot autonomously moves along the insulator string using the clamps installed on its two moving frames, and adopts a dry cleaning method using rotating brushes and a circular motion guide. In addition, a mechanized brush bristles and a voltage-balancing contactor are devised to increase cleaning efficiency and to prevent arc generation under live-line conditions, respectively. Moreover, a manual tool for its installation and removal is presented. We confirmed its effectiveness through experiments.

  • PDF

Tracking Property of Polymer Suspension Insulator for Transmission line with secular variation (경년변화에 따른 송전용 폴리머 현수애자의 트래킹 성능평가)

  • Cho, Han-Goo;Lee, Un-Yong;Lee, You-Jung;Lim, Kee-Joe;Choi, In-Hyuk
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.558-559
    • /
    • 2005
  • Recently, polymer insulators that are used for high voltage applications have some advantages such as light weight, small size, vandalism resistance, hydrophobicity and easy making process. During outdoor service of polymer insulators, the surface of the insulating material is frequently subjected to moisture and contamination that lead to dry band arcing. Their tracking resistance, erosion resistance, end sealing and shed design are very important because dry band arcing causes degradation of polymer surface. In this paper, the tracking property of polymer suspension insulator for power transmission is investigated with CEA tracking wheel test. The diagnosis of insulator sample in tracking test has been analyzed by leakage current, STRI Guide, SEM, FTIR and thermal image.

  • PDF

A Study on Mechanism about Contaminant Accumulation of Insulator Surface (애자표면의 오손물 누적에 관한 메커니즘 연구)

  • Park, Jae-Jun
    • The Journal of Information Technology
    • /
    • v.8 no.2
    • /
    • pp.85-91
    • /
    • 2005
  • We studied a pollution mechanism for simulation of contamination environment in industrial concentrated area of around a metropolitan that made to circulated flow in the chamber. In case of the virgin both side of EPDM or Silicon insulator, we confirmed that the pollution to much more than service insulator in the field. Also contamination of initial state of the virgin didn't falling in spite of physical outside factor easily. This study confirmed to that the silicon was too much accumulated pollution contrast to EPDM insulator from scatter(spray) point to regular interval position use the Kaolin contaminant in the chamber. There are effected to the hydrophobicity of polymer insulator due to the pollution. In ceramic insulator, we get to know that pollution is much more at the Post insulator with vertical than with horizontal setup insulator.

  • PDF

The Design Analysis of Distribution Polymer Suspension Insulator (배전용 폴리머 현수애자의 설계해석)

  • Lee, Un-Yong;Cho, Han-Goo;Han, Dong-Hee;Lim, Kee-Jo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.05c
    • /
    • pp.66-68
    • /
    • 2001
  • Recently polymer insulators are being used for outdoor high voltage applications. Polymer insulators for transmission and distribution line have significant advantages over porcelain and glass insulators, especially for ultra-high voltage(UHV) transmission lines. Their advantages are light weight, vandalism resistance and hydrophobicity. In this paper, distribution polymer suspension insulator has been designed and investigated electric field distribution by FEM.

  • PDF

Development of Extra High Voltage(400kN) Porcelain Insulator for Transmission Lines (765 kV용 400 kN 현수애자 개발)

  • 최인혁;최장현;이동일;최연규
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.8
    • /
    • pp.348-353
    • /
    • 2003
  • This paper was the research of high voltage suspension insulator (400 [kN]) including pottery stone, feldspar, clay and alumina of 17 [wt%]. The slurry was fabricated after ball milling mixed raw materials. Green compacts were made by the extrusion of jiggering method and were sintered at 1300[$^{\circ}C$] for 50 [min.] in the tunnel kiln. The sintered density was reached to 97% of theoretical density, and the bending strength was 1658 [k $g_{f}$/$\textrm{cm}^2$] and hardness and fracture toughness which was measured by ICL( indentation crack length ) method were 1658 (kgf/$\textrm{cm}^2$) and 27.5 [Gpa], respectively. In measurement of tana and insulation break voltage of 400 (kN) porcelain, tan$\delta$ took some numerical value between 17${\times}$10$_{-3}$ and 61${\times}$10$_{-3}$ and insulation break voltage value was 19.9$\pm$1.4 [㎸/mm]. The test was performed to research whether the shape of pin affect a overvoltage break load or not As a consequence, when a pin was designed a pin diameter 51 [mm] with the bottom form of two-step constructed with straight in the suspension insulator, Insulator showed overvoltage break load 52 [ton] of the highest value and reflected a fine characteristic in aged deterioration test which is one of the accelerated aging test. Also it could be confirmed a fine characteristic through performing the test that electrical property of insulator was established correctly in accordance with IEC 60383-1 standards.s.

Surface and Tracking Properties of Polymer Suspension Insulator for Power Transmission with secular variation (경년열화에 따른 송전용 폴리머 현수애자의 표면 및 트래킹 성능)

  • Cho, Han-Goo;Lee, Un-Yong;Han, Se-Won;Han, Dong-Hee;Huh, Jong-Chul;Choi, In-Hyuk
    • Proceedings of the KIEE Conference
    • /
    • 2004.11a
    • /
    • pp.233-236
    • /
    • 2004
  • Recently, the polymer insulators that are used for high voltage applications have some advantages such as light weight, small size, vandalism resistance, hydrophobicity and easy making process. During outdoor service of polymer insulators, the surface of the insulating material is frequently subjected to moisture and contamination that lead to dry band arcing. Their tracking resistance, erosion resistance, end sealing and shed design are very important because dry band arcing causes degradation of polymer surface. The shape design of porcelain insulator is formalized but design standard for polymer insulator is no standardized up to now, much research is necessary in real condition. In this paper, the surface and tracking properties of polymer suspension insulator for power transmission is investigated with ICP-AES, SEM, EDX, tracking wheel test and flashover voltage test. The diagnosis of insulator sample in tracking test hass been analyzed by leakage current STRI Guide and thermal image.

  • PDF

The design analysis of epoxy casting resins insulator for distribution line (에폭시 캐스팅수지 애자의 형상해석)

  • Song, I.K.;Kim, Y.L.;Park, G.P.;Kwak, H.R.;Jeon, S.J.;Kwon, D.J.;Kim, S.K.
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.411-413
    • /
    • 1995
  • Porcelain insulators have been used for the almost all of the suspension insulators in distribution line. However, Puncture breakdowns in porcelain insulators caused by westing cement between metal fitting and porcelain material. There is little puncture breakdown in Epoxy casting insulator. This paper presents a new design technique for the development of suspension insulator used Cycloaliphatic Epoxy resin. The design was performed on the basis of two conditions (weather conditions for the past 30 years and the existing installation conditions of KEPCO) and was proven of its adaptability by FEM method.

  • PDF

Simulation of interface ageing effect of suspension insulator using ANSYS (ANSYS를 이용한 현수애자의 계면팽창거동에 대한 해석)

  • Woo, B.C.;Han, S.W.;Cho, H.G.;Choi, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 2002.11a
    • /
    • pp.74-76
    • /
    • 2002
  • The suspension insulators are subjected to harsh environment in service for a long time. Long term reliability of the insulators is required for both mechanical and electrical performances. We studied an analysing method to find out a deformation of brittle porcelain with a thermal expansion of cement for suspension insulator. These simulation analysis and experimental results show that cement volume growths affect severely to be mechanical failure ageing.

  • PDF

Multi-Stress Aging Test Technology for Suspension Polymer Insulator (폴리머 현수애자의 복합가속열화 평가기술)

  • Park, Hoy-Yul;Kang, Dong-Pil;Kim, Ik-Soo;Shin, Young-Jun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07a
    • /
    • pp.481-484
    • /
    • 2003
  • Recently polymer insulators are being used for outdoor high voltage applications. Polymer insulators have significant advantages over porcelain and glass insulators. With the gradual improvement of their design and material, their reliability has also increased. It is however difficult to establish how they will perform after several years of service. Aging of the insulator weathershed may lead to damages such as excessive chalking and crazing, erosion and tracking which affect the insulator performance. In service insulator are subjected to aging stresses such as humidity, pollution and electrical field which act singly or in combination. There have been numerous accelerated laboratory tests developed with the intention of evaluating suitability of polymeric materials. Some of these are strictly material tests, where as, others evaluate full scale devices. Service experience plays a key role in the utility selection of polymer insulator, but is time consuming, and may not always be available. Hence there is a need for a meaningful and reliable accelerated aging test for polymer insulator. This paper describes multi-stress aging test for reliability of polymer insulator This paper presents the rule of multi-stress aging test and test chamber for polymer insulator in korea electrotechnology research institute.

  • PDF