• Title/Summary/Keyword: suspended time

Search Result 555, Processing Time 0.028 seconds

Removal of Total Suspended Solids by a Foam Fractionator in a Simulated Seawater Aquaculture System

  • Peng, Lei;Jo, Jae-Yoon
    • Journal of Aquaculture
    • /
    • v.16 no.4
    • /
    • pp.216-222
    • /
    • 2003
  • In a simulated seawater aquaculture system, effects of different operating factors like the superficial air velocity (SAY), hydraulic residence time (HRT), protein concentration and foam overflow height on the removal of total suspended solids (TSS) by a foam fractionator, with 20 cm diameter and 120 cm height, were investigated. This experiment was performed on batch and consecutive modes for different combinations of the tested factors, using synthetic wastewater. In 5 consecutive trials, TSS concentration in culture tank water decreased faster, when the foam fractionator was operated at higher SAV and lower HRT. In batch trials, with increasing SAV, TSS removal rate increased, but decreased with increasing HRT. Higher protein concentration in the bulk solution resulted in higher TSS removal rate. TSS concentration in the collected foam condensates increased but the foam overflow rate decreased with increasing foam overflow height. Foam fractionation was effective for removing TSS in seawater aquaculture systems and its performance largely depended on the operating parameters, especially superficial air velocity.

The Quantitative Characterization of the Dispersion State of Single-Walled Carbon Nanotubes (단일벽 탄소나노튜브의 분산도 정량적 평가)

  • Yoon, Do-Kyung;Choi, Jae-Boong;Kim, Young-Jin;Baik, Seung-Hyun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.31 no.4
    • /
    • pp.483-489
    • /
    • 2007
  • We have investigated quantitative measurement techniques of the degree of dispersion of single-walled carbon nanotubes (SWNTs). SWNTs were suspended in aqueous media using a sodium dodecyl sulfate (SDS) surfactant. SWNTs with different dispersion states were prepared by controlling the intensity and time of sonication and centrifugation. The laser spectroscopic techniques were employed to characterize the dispersion state; i.e., raman fluorescence and absorption spectroscopic techniques. Raman spectroscopy has been used to probe the dispersion and aggregation state of SWNTs in solution. Individually suspended SWNTs show increased fluorescence peaks and decreased roping peaks at a raman shift 267 $cm^{-1}$ compared with the samples containing bundles of SWNTs. The ultraviolet-visible-near infrared (UV-vis-NIR) absorption spectrum of decanted supernatant samples show sharp van Hove singularity peaks

Treatability Study on the SepticTAnk Sludges

  • Byung Soo Yang
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.17 no.1
    • /
    • pp.41-47
    • /
    • 1981
  • The characteristics of septic tank sludges were investigated and the kinetic coefficients in the aerobic biodegradation were evaluated from bach treatability tests. Using an unbiased statistical method, the estimated values, k (substrate removal rate coefficient) =0. 0175hr-1 at 17\ulcornerC, K. (Michaelis Menten constant) = 248mg/ e, a (cell yield coefficient)=0.625, and Kd (cell decay coefficient:' =0. 00192hr-1 were obtained based on biodegradable COD(mg/ \ulcorner) and volatile suspended solids(mg/\ulcorner). The relationship between COD and BOD, COD (mg/\ulcorner) =2. 1 BOD(mg/\ulcorner) +250, also was established for the septic tank sludges. Dilution was inevitable for the grit removal because of the high viscosity of the sludges. An aerobic activated sludge process rather than anaerobic processes was recommended for the removal of soluble organics after the removal of grit and suspended solids. A multi-stage activated sludge process was adapted for this highly concentrated and not easily-degradable waste. It was estimated that a four-stage activated sludge process would require 40 hours retention time compared to 92 hours for a single-stage process, 52 hours for a double-stage process, and 46 hours for a three stage process in order to achieve an effluent quality of 84mg/ e COD( 40mg/ e BOD) with about 4, OOOmg/ \ulcorner MLSS from an influent quality of I, 500mg/ t COD(714mg/.e BOD), while multi-stages beyond four stage would not save the required retention time significantly.

  • PDF

Feasibility Study of UV-Disinfection for Water Reuse of Effluent from Wastewater Treatment Plant (용수재이용을 위한 하수처리 유출수의 UV 소독 효율 연구)

  • 윤춘경;정광욱;함종화;전지홍
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.45 no.2
    • /
    • pp.126-137
    • /
    • 2003
  • The feasibility study of UV-disinfection system was performed for disinfection of effluent from wastewater treatment plant. Three low-pressure UV lamps of 17, 25, and 41 W were examined with various flow rates. Low-pressure UV lamps of 17W were examined with various turbidity, DOM (dissolved organic matter), and SS (suspended solid). The pilot plant was a flow-through type UV-disinfection system, and the range of exposure time varied from 5 to 40 seconds, turbidity from 0 to 40 NTU, DOM from 0 to 30 mg/L, and SS from 10 to 40 mg/L. The 41W lamp demonstrated complete disinfection showing no survival ratio in all the experimental conditions, and generally 17W and 25W lamps also showed high removal ratio over 97%. For the same UV dose (UV intensity times exposure time), high intensity-short exposure conditions showed better disinfection efficiency than low intensity-long exposure conditions. While the effects of turbidity and DOM were not apparent, the effects of SS was significant on the disinfection efficiency which indicates that SS control before UV-disinfection appears to be necessary to increase removal efficiency. Considering characteristics of effluent from existing wastewater treatment plants, cost-effectiveness, stable performance, and minimum maintenance, the flow-through type UV-disinfection system with high intensity and low-pressure lamps was thought to be a competitive disinfection system for wastewater reclamation.

The Evaluation of Water Quality in Coastal Sea of Kunsan Using Statistic Analysis (통계분석기법을 이용한 군산연안해역의 수질평가)

  • Lee, Nam-Do;Kim, Jong-Gu
    • Journal of Environmental Science International
    • /
    • v.16 no.3
    • /
    • pp.369-376
    • /
    • 2007
  • This study was conducted to evaluate water quality in coastal sea of Kunsan using multivariate analysis. The analysis data in Coastal Sea of Kunsan use of surveyed data by the NFRDI from April 2000 to November 2002. Twelve water Quality parameter were determined on each sample. The results was summarized as follow ; Water quality in coastal sea of Kunsan could be explained up to 62.782% by four factors which were included in loading of nitrogen-nutrients by Keum river(24.688%), suspended solids variation (12.180%), seasonal climate variation (18.367%) and variation of DIP (10.546%). To analyze spatially and monthly variation by factor score, it was divided by inner area and outer area spatially, and spring and summer monthly. The result of time series analysis by factor score, inner area of Kunsan coastal sea(St.1 and St. 2) was the most affected by nitrogen-nutrient and suspended solids due to runoff by Keum river. It could be suggested from these results that it is important to reduce tile pollution loads from Kuem river for the control of the water quality in coastal sea of Kunsan.

Fundamental Properties of Antiwashout Underwater Concrete Mixed with Mineral Admixtures

  • Han-Young, Moon;Kook-Jae, Shin;Yong-Kyu, Song
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.11a
    • /
    • pp.457-460
    • /
    • 2003
  • This paper discusses laboratory evaluations to assess the physical properties of antiwashout underwater concrete (AWC) containing pozzolanic materials such as fly ash (FA), blast furnace slag (SG) and metakaolin(MK). For the experiments, pH value, suspended solids, slump flow, efflux time and compressive strength were tested. According to the results from compressive strength test, MK10 showed the very high compressive strength characteristic during the entire curing days, but the rate of strength development was decreased as time goes by.

  • PDF

Prediction of Seabed Topography Change Due to Construction of Offshore Wind Power Structures in the West-Southern Sea of Korea (서남해에서 해상풍력구조물의 건설에 의한 해저지형의 변화예측)

  • Jeong, Seung Myung;Kwon, Kyung Hwan;Lee, Jong Sup;Park, Il Heum
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.31 no.6
    • /
    • pp.423-433
    • /
    • 2019
  • In order to predict the seabed topography change due to the construction of offshore wind power structures in the west-southern sea of Korea, field observations for tides, tidal currents, suspended sediment concentrations and seabed sediments were carried out at the same time. These data could be used for numerical simulation. In numerical experiments, the empirical constants for the suspended sediment flux were determined by the trial and error method. When a concentration distribution factor was 0.1 and a proportional constant was 0.05 in the suspended sediment equilibrium concentration formulae, the calculated suspended sediment concentrations were reasonably similar with the observed ones. Also, it was appropriate for the open boundary conditions of the suspended sediment when the south-east boundary corner was 11.0 times, the south-west was 0.5 times, the westnorth 1.0 times, the north-west was 1.0 times and the north-east was 1.0 times, respectively, using the time series of the observed suspended sediment concentrations. In this case, the depth change was smooth and not intermittent around the open boundaries. From these calibrations, the annual water depth change before and after construction of the offshore wind power structures was shown under 1 cm. The reason was that the used numerical model for the large scale grid could not reproduce a local scour phenomenon and they showed almost no significant velocity change over ± 2 cm/s because the jacket structures with small size diameter, about 1 m, were a water-permeable. Therefore, it was natural that there was a slight change on seabed topography in the study area.

Monitoring of the Suspended Sediments Concentration in Gyeonggi-bay Using COMS/GOCI and Landsat ETM+ Images (COMS/GOCI 및 Landsat ETM+ 영상을 활용한 경기만 지역의 부유퇴적물 농 도 변화 모니터링)

  • Eom, Jinah;Lee, Yoon-Kyung;Choi, Jong-Kuk;Moon, Jeong-Eon;Ryu, Joo-Hyung;Won, Joong-Sun
    • Economic and Environmental Geology
    • /
    • v.47 no.1
    • /
    • pp.39-48
    • /
    • 2014
  • In coastal region, estuaries have complex environments where dissolved and particulate matters are mixed with marine water and substances. Suspended sediment (SS) dynamics in coastal water, in particular, plays a major role in erosion/deposition processes, biomass primary production and the transport of nutrients, micropollutants, heavy metals, etc. Temporal variation in suspended sediment concentration (SSC) can be used to explain erosion/sedimentation patterns within coastal zones. Remotely sensed data can be an efficient tool for mapping SS in coastal waters. In this study, we analyzed the variation in SSC in coastal water using the Geostationary Ocean Color Imager (GOCI) and Landsat Enhanced Thematic Mapper Plus (ETM+) in Gyeonggi-bay. Daily variations in GOCI-derived SSC showed low values during ebb time. Current velocity and water level at 9 and 10 am is 37.6, 28.65 $cm{\cdot}s^{-1}$ and -1.23, -0.61 m respectively. Water level has increased to 1.18 m at flood time. In other words, strong current velocity and increased water level affected high SSC value before flood time but SSC decreased after flood time. Also, we compared seasonal SSC with the river discharge from the Han River and the Imjin River. In summer season, river discharge showed high amount, when SSC had high value near the inland. At this time SSC in open sea had low value. In contrast, river discharge amount from inland showed low value in winter season and, consequently, SSC in the open sea had high value because of northwest monsoon.

Characteristics of Proteins and Total Suspended Solids Removal by Counter Current Air Driven Type, High Speed Aeration Type and Venturi Type Foam Separator in Aquacultural Water (향류 공기 구동식, 고속 폭기식 및 벤튜리식 포말분리기에 의한 양어장수의 단백질 및 부유 고형물의 제거 특성)

  • SUH Kuen-Hack;KIM Byong-Jin;KIM Sung-Koo
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.33 no.3
    • /
    • pp.205-212
    • /
    • 2000
  • Experimental investigations on the removal of protein, total suspended solids and turbidity from aquacultural water were carried out by using three types of foam separator: counter current air driven type foam separator (CCADFS), high speed aeration type foam separator (HSAFS) and venturi type foam separator (VFS). The decrease of flow rate by CCADFS, HSAFS and VFS were $0.4,\;66.1,\;77.2 {\%}$ respectively. Protein removal rates by three types foam separator were decreased with the increased hydraulic residence time (HRT). Bellw 0.32 minute and 0.21 minute of hydraulic residence times, protein removal rate of HSAFS and YES was higher than that of CCADFS, respectively. Protein removal rate of VFS was lower than that of HSAFS at any HRT. As increasing the HRT, protein removal efficiency of CCADFS was increased, but that of HSAFS and VES were decreased. The changes of removal rates and efficiencies of total suspended solid and turbidity were similar to proteins.

  • PDF

Measurements of Vertical Profiles in Suspended-Load Concentration Using the ASM-IV (ASM-IV를 이용한 부유사농도 연직분포의 측정)

  • Lee, Jong-Seok;Myeng, Bong-Jae;Cha, Young-Kee
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.6 no.1 s.20
    • /
    • pp.83-95
    • /
    • 2006
  • This study aims to analysis of suspended-load concentration in related to those data by measuring vertical sediments distribution with rainfall using the ASM (Argus Surface Meter)- IV at the channel reach of a upstream and a downstream in small river. The watershed, small river basin where had taken for experimental study was selected, which is a drainage area lied at Walha in Yunkee-Gun, Chungnam Province. Measured data of suspended-load concentration consists of two groups with 2,145 data during 1hr 11min 30sec and 1,216 data during 40min 32sec for measuring time of 2 second in the study reaches at river, respectively. In order to analyze of the vertical concentration distribution, using the data sets are selected the measuring time 16 sets one of these data by random in the study reaches. As a results, the Rouse number of a measured and a calculated value show that a rang of $0.00129{\sim}0.02394$, averaged value of 0.01129 md, a rang of $0.00118{\sim}0.00822$, averaged value of 0.00436 in upstream reaches, and also a rang of $0.065115{\sim}0.065295$, averaged value of 0.06521, and a rang of $0.057315{\sim}0.059109$, averaged value of 0.05795 in downstream reaches, respectively. These difference show that measured Rouse number compared with downstream reach errors of less than in upstream reach, but between measured and calculated of the Rouse number compared with downstream reach errors of more than in upstream reach, respectively. It seems to will be included one of the occurrence errors of variable estimations when Rouse number of calculated value to be made computed by the fall velocity with a high temperature of water using equation of empirical kinematic viscosity was derived in this study.