• 제목/요약/키워드: suspended building structure

검색결과 14건 처리시간 0.02초

Seismic behavior of suspended building structures with semi-rigid connections

  • Liu, Yuxin;Lu, Zhitao
    • Earthquakes and Structures
    • /
    • 제7권4호
    • /
    • pp.415-448
    • /
    • 2014
  • A method is presented in this paper to analyze the dynamic response behavior of suspended building structures. The effect of semi-rigid connections that link suspended floors with their supporting structure on structural performance is investigated. The connections, like the restrains in non-structural suspended components, are designed as semi-rigid to avoid pounding and as energy dissipation components to reduce structural response. Parametric study is conducted to assess the dynamic characteristics of suspended building structures with varying connection stiffness and suspended mass ratios. Modal analysis is applied to identify the two distinct sets of vibration modes, pendulum and bearing, of a suspended building structure. The cumulative modal mass is discussed to ensure the accuracy in applying the method of response spectrum analysis by SRSS or CQC modal combination. Case studies indicate that a suspended building having semi-rigid connections and proper suspended mass ratios can avoid local pounding failure and reduce seismic response.

자율주행차량과 건축의 결합을 위한 고층 구조 시스템 제안 및 설계 적용 (Proposal and Design Application of High-Rise Structural System for Combining Autonomous Vehicles and Architecture)

  • 박상우;윤성원
    • 한국공간구조학회논문집
    • /
    • 제20권1호
    • /
    • pp.31-40
    • /
    • 2020
  • The purpose of this study is to propose future-oriented high-rise buildings where the vehicle is parked at the top of the building. At the same time, the vehicle is used as a part of the building along with the advent of the era of autonomous driving. The suspended structure is proposed as a suitable structural system for architectural planning. This system is free to design because there are no limitations on column planning compared to conventional designs. In particular, the low-floor plan can be used as an open space because colums are not arranged in the lower-floors. Thereby opened low-floor plan has advantages that visual perception of the space is improved, noise problems along the side of the street is solved and planning underground parking spaces are easier. These advantages can solve the problem of overlapping columns with vehicle traffic in the building. However, there are some problems that the suspension structure is mainly a formal form and the usable area is small compared to the core area because it is a core-oriented structural system. In this regard, a new structural system was proposed by combining the concept of suspended structure and cable stayed column. Therefore, this paper analyzes the existing style of high-rise housing suspended Structure and proposes a new structural system and the concept of design for autonomous vehicles.

Suspended Columns for Seismic Isolation in Structures (SCSI): A preliminary analytical study

  • Shahabi, Ali Beirami;Ahari, Gholamreza Zamani;Barghian, Majid
    • Earthquakes and Structures
    • /
    • 제16권6호
    • /
    • pp.743-755
    • /
    • 2019
  • In this paper, a new system of seismic isolation for buildings - called suspended columns - is introduced. In this method, the building columns are placed on the hinged cradle seats instead of direct connection to the foundation. In this system, each of the columns is put on a seat hung from its surrounding area by a number of cables, for which cavities are created inside the foundation around the columns. Inside these cavities, the tensile cables are hung. Because of the flexibility of the cables, the suspended seats vibrate during an earthquake and as a result, there is less acceleration in the structure than the foundation. A Matlab code was written to analyze and investigate the response of the system against the earthquake excitations. The findings showed that if this system is used in a building, it results in a significant reduction in the acceleration applied to the structure. A shear key system was used to control the structure for service and lateral weak loads. Moreover, the effect of vertical acceleration on the seismic behavior of the system was also investigated. Effect of the earthquake characteristic period on the system performance was studied and the optimum length of the suspension cables for a variety of the period ranges was suggested. In addition, measures have been taken for long-term functioning of the system and some practical feasibility features were also discussed. Finally, the advantages and limitations of the system were discussed and compared with the other common methods of seismic isolation.

진자슬래브에 의한 진동제어시스템의 적용성 평가 (Study on the Application of Tuned Pendulum Slab Damper system (TPSD) to Building structure)

  • 김양중;서근배
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2012년도 추계 학술논문 발표대회
    • /
    • pp.181-184
    • /
    • 2012
  • The Tuned Pendulum Slab Damper(TPSD)system is mainly composed of suspended pendulum slab which was hanging with cable wire from the top floor of building without any extra loads structurally, and can be helpful to reduce vibration with effect of tuned mass damper function by the principle of pendulum movement. The experiment was performed with miniatures of the 30stories of steel structure building by the forced vibration test using shaking table, and the result was reduced about 42% of vibration. The purpose of this study was to make analysis of application of the TPSD system to new building and exist building against strong wind or seismic wave. The result of this study was that the TPSD system shall be satisfactory in field of execution, process control, safety and economical efficiency with saving up to 70% of construction cost.

  • PDF

Optimum topology design of geometrically nonlinear suspended domes using ECBO

  • Kaveh, A.;Rezaei, M.
    • Structural Engineering and Mechanics
    • /
    • 제56권4호
    • /
    • pp.667-694
    • /
    • 2015
  • The suspended dome system is a new structural form that has become popular in the construction of long-span roof structures. Suspended dome is a kind of new pre-stressed space grid structure that has complex mechanical characteristics. In this paper, an optimum topology design algorithm is performed using the enhanced colliding bodies optimization (ECBO) method. The length of the strut, the cable initial strain, the cross-sectional area of the cables and the cross-sectional size of steel elements are adopted as design variables and the minimum volume of each dome is taken as the objective function. The topology optimization on lamella dome is performed by considering the type of the joint connections to determine the optimum number of rings, the optimum number of joints in each ring, the optimum height of crown and tubular sections of these domes. A simple procedure is provided to determine the configuration of the dome. This procedure includes calculating the joint coordinates and steel elements and cables constructions. The design constraints are implemented according to the provision of LRFD-AISC (Load and Resistance Factor Design-American Institute of Steel Constitution). This paper explores the efficiency of lamella dome with pin-joint and rigid-joint connections and compares them to investigate the performance of these domes under wind (according to the ASCE 7-05), dead and snow loading conditions. Then, a suspended dome with pin-joint single-layer reticulated shell and a suspended dome with rigid-joint single-layer reticulated shell are discussed. Optimization is performed via ECBO algorithm to demonstrate the effectiveness and robustness of the ECBO in creating optimal design for suspended domes.

제주도내 공사중단 장기방치 건축물 현황과 문제점 (Status and Problems of Buildings Neglected for Long Period after Discontinuance of Construction in Jeju)

  • 김두성;한인덕;장명훈
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 봄 학술논문 발표대회
    • /
    • pp.153-154
    • /
    • 2023
  • Neglected buildings for long period can seriously reduce the durability of the building due to rust in rebars and deterioration in concrete quality due to exposure to outside air, and the seriousness of suspended buildings such as safety accidents and social crimes is emerging due to poor management. In this study, various problems such as the occurrence of safety accidents were analyzed through a fact-finding survey of buildings that have not been maintained due to long-term neglect in all areas of Jeju. In order to reuse a building that has been discontinued, the safety of the building structure itself must be checked. After securing safety through durability investigation, construction should be resumed or converted into a normal building through re-purposing, dismantling, remodeling, etc.

  • PDF

Wind load parameters and performance of an integral steel platform scaffold system

  • Zhenyu Yang;Qiang Xie;Yue Li;Chang He
    • Wind and Structures
    • /
    • 제36권4호
    • /
    • pp.263-275
    • /
    • 2023
  • As a new kind of construction facility for high rise buildings, the integral steel platform scaffold system (ISPS) consisting of the steel skeleton and suspended scaffold faces high wind during the construction procedure. The lattice structure type and existence of core tubes both make it difficult to estimate the wind load and calculate the wind-induced responses. In this study, an aeroelastic model with a geometry scale ratio of 1:25 based on the ISPS for Shanghai Tower, with the representative square profile, is manufactured and then tested in a wind tunnel. The first mode of the prototype ISPS is a torsional one with a frequency of only 0.68 Hz, and the model survives under extreme wind speed up to 50 m/s. The static wind load and wind vibration factors are derived based on the test result and supplementary finite element analysis, offering a reference for the following ISPS design. The spacer at the bottom of the suspended scaffold is suggested to be long enough to touch the core tube in the initial status to prevent the collision. Besides, aerodynamic wind loads and cross-wind loads are suggested to be included in the structural design of the ISPS.

제주지역 공사중단 건축물의 현황조사 및 내구성 분석 (Current Status and Analysis of Durability for Buildings Long Neglected after Construction Discontinuation in Jeju)

  • 한인덕;김두성;장명훈
    • 한국건축시공학회지
    • /
    • 제23권4호
    • /
    • pp.441-452
    • /
    • 2023
  • 장기방치된 공사중단 건축물들은 외기의 노출로 인한 철근의 녹 발생, 콘크리트의 품질 저하 등으로 건축물의 내구성이 심각하게 저하될 수 있으며, 관리부실로 안전사고, 사회적 범죄 발생, 환경오염 등 공사중단 건축물에 대한 심각성이 커지고 있다. 본 연구는 제주 지역의 공사중단 건축물의 현황을 조사하고 문제점을 파악하고, 1곳에 대해 구조체의 내구성을 조사분석하여 사용가능성을 진단하였다. 내구성 조사를 위해 외관조사(육안조사, 기울기조사)와 비파괴검사(압축강도시험, 탄산화조사시험, 철근탐사시험)이 진행되었으며, 구조체가 내구성을 갖추고 있으며 건축물의 상태는 경과년수에 비하여 양호한 것으로 분석되었다.

남조류 제거를 위한 선회식 가압부상장치 현장 적용에 관한 연구 (A Study on Pilot Scale Cyclonic-DAF Reactor for Cyanobacteria Removal)

  • 오홍석;강선홍;남숙현;김은주;구재욱;황태문
    • 한국환경복원기술학회지
    • /
    • 제21권5호
    • /
    • pp.17-28
    • /
    • 2018
  • Cyclonic-dissolved air flotation(Cyclonic-DAF), an advanced form of pressure flotation, applies a structure that enables the forming of twirling flows. This in turn allows for suspended matter to adhere to microbubbles and float to the surface of a treatment tank during the process of intake water flowing through a float separation tank. This study conducted a lab-scale test and pursued geometrical modeling using computational fluid dynamics(CFD) to establish a pilot scale design. Based on the design parameters found through the above process, a pilot cyclonic-DAF system($10m^3/hr$) for removing algae was created. Upon developing the pilot-scale cyclonic-DAF system, a type of algae coagulant(R-119) was applied as the coagulant to the system for field testing through which the removal rates of chlorophyll-a and cyanobacteria were evaluated. The chlorophyll-a and harmful cyanobacteria of the raw water at region B, the field-test site, were found to be $177.9mg/m^3$ and 652,500cells/mL respectively. Treated waters applied with 60mg/L and 100mg/L of algae coagulant presented removal efficiencies of approximately 95% and 97%, respectively. The cyanobacteria cell number of the treated waters applied with 60mg/L and 100mg/L of algae coagulant both that were equal to or less than 1,000cells/mL and were below attention level criteria for the issuance of algae boundary.

실규모 현장 실험 기반 H-ADCP 초음파 산란도 활용 소하천용 하천 부유사 농도 측정 기법 개발 (Estimation of Suspended Sediment Concentration in Small Stream with Acoustic Backscatter from Horizontal ADCP based on Real-Scale Field Experiment)

  • 서강현;김동수;손근수
    • 대한토목학회논문집
    • /
    • 제36권6호
    • /
    • pp.1023-1035
    • /
    • 2016
  • 부유사 농도는 유사이송해석, 하천 및 구조물의 안정성 평가 등에 있어서 매우 중요한 자료라 할 수 있다. 그러나, 국내의 경우 주로 재래식 채집방식으로 유사량을 관측하고 있어 유사량 자료가 현저히 부족한 실정이다. 이에 본 연구에서는 수평초음파도플러유속계(H-ADCP)에서 제공하는 신호대잡음비(SNR)와 레이저부유사측정기(LISST-100X)를 활용한 실측 부유사농도와의 상관관계를 구축하여 H-ADCP를 활용하여 공간 시간적으로 정밀한 유사량을 지속적으로 추정할 수 있는 기법을 개발하고자 한다. 이를 위해 H-ADCP의 신호대잡음비 보정식을 개발하였으며, 실규모 하천에서 유사를 인위적으로 공급하며 H-ADCP와 LISST를 활용하여 신호대잡음비와 부유사농도 자료를 계측하고, 개발된 보정식이 적용된 신호대잡음비-부유사농도(SNR-SSC) 관계식을 시범적으로 구축해 보았다. 구축한 SNR-SSC 관계로부터 상관계수 0.85~0.88의 상대적으로 높은 상관도를 가진 선형회귀식을 구성할 수 있었으며, 본 연구 결과는 자동유량측정장치로 사용되고 있는 H-ADCP를 적절히 활용할 경우 실시간 유사량 관측이 가능하다는 점을 시사한다.