• Title/Summary/Keyword: surgical procedure

Search Result 1,898, Processing Time 0.025 seconds

All-on-6 implant fixed prosthesis restoration with full-digital system on edentulous patient: A case report (무치악 환자에서 완전 디지털 시스템을 활용한 All-on-6 임플란트 고정성 보철물 수복 증례)

  • Lee, SeungJin;Jeong, Seung-Mi;Chung, Chae-Heon;Fang, YiQin;Choi, Byung-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.4
    • /
    • pp.497-507
    • /
    • 2021
  • All-on-six concept can be used as one of the treatment options to maximize the use of available residual alveolar bone for implant-supported fixed prosthesis on edentulous patients. But this process is complex and cumbersome. Digital system can be used at multiple steps, from implantation to prosthetic restoration, to overcome this shortcoming. In this case of a maxillary edentulous patient aged 76, digital system was used for restoration of 1-piece design, screw retained fixed prosthesis from diagnosis, implant surgery to fabrication of provisional and final prosthesis. For preoperative diagnosis and treatment planning stage, intra-oral information of a patient was digitalized by direct intra-oral scan. Surgical guide and immediate provisional prosthesis was designed based on this digitalized data. Patient's inconvenience was minimized by applying immediate provisional prosthesis, which was delicately fabricated according to the location data of six implants on most suitable residual alveolar bone. Then, final prosthesis was designed and fabricated going through new interim prosthesis which was newly designed and fabricated, considering patient's requests, stable vertical dimension and occlusion, and esthetic factors using digital system. We hereby report a case successfully applying digital system to multiple steps including implant surgery to fabricating prosthesis, to simplify existing complicated implant treatment procedure to an edentulous patient.

A Study on the Health Information Management Practice Program Model for EMR Certification System Education -Focus on Patient Information Management- (EMR 인증제 교육을 위한 보건의료정보관리 실습 프로그램 모델 연구 -환자정보관리 중심-)

  • Choi, Joon-Young
    • Journal of the Health Care and Life Science
    • /
    • v.9 no.1
    • /
    • pp.1-9
    • /
    • 2021
  • In this study, a model in which certification standards were added to the health information management practice program was studied and presented in order to understand the EMR certification standards implemented by the Korea Health and Medical Information Service. In the practice program, the certification standard function for patient information management was added to the health information management education system to practice and understand patient information management that corresponds to the functional standard of the EMR certification system. The EMR certification standard practice program for patient information management is composed of the following certification standards. registration number and personal information management, treatment reservation schedule management, personal information revision history management, identification of people with the same name, integrated management of multiple registration numbers, patient search by identification information, patient search by health care type, surgical procedure consent record and inquiry, record/inquiry of consent form for personal information use, display of life-sustaining medical decision information, registration/inquiry of external medical institution documents, registration and inquiry of external examination results. In this way, by operating and practicing the functions of the health information system according to the certification standards, it is possible to understand and practice the certification standards and details of patient information management in the functional area of the certification standards. In addition, since the function of the EMR certification standard can be checked, it will be possible to improve the management ability of the electronic medical record system of the health information manager in the medical institution.

Computer-Assisted Navigation in Total Knee Arthroplasty (내비게이션 장치를 이용한 슬관절 전치환술)

  • Jeong, Hwa-Jae;Park, Yong-Beom;Lee, Han-Jun
    • Journal of the Korean Orthopaedic Association
    • /
    • v.53 no.6
    • /
    • pp.478-489
    • /
    • 2018
  • Total knee arthroplasty has become a standard procedure for advanced knee arthritis to relieve pain and improve function. Computer-assisted navigation systems have been used in total knee arthroplasty to improve the mechanical axis of the limb as well as the alignment and position of the components. A computer-assisted navigation system has the advantage of real-time feedback during surgery, such as mediolateral balance in extension and flexion gap, alignment of the lower limb, and components. On the other hand, the computer-assisted navigation system requires an additional stab wound for tracker fixation, which can increase the likelihood of superficial wound infection and stress fractures and increase the operation time and cost of surgery. The clinical efficacy of computer-assisted navigation in total knee arthroplasty is also controversial. Compared to the conventional technique, computer navigation improves the accuracy of the postoperative mechanical axis within outliers of $3^{\circ}$ varus or $3^{\circ}$ valgus. This paper reviews the surgical technique, pitfalls, clinical and radiological outcomes, useful clinical cases, and future perspectives in computer-assisted navigation total knee arthroplasty.

Risk Factors of Allogenous Bone Graft Collapse in Two-Level Anterior Cervical Discectomy and Fusion

  • Woo, Joon-Bum;Son, Dong-Wuk;Lee, Su-Hun;Lee, Jun-Seok;Lee, Sang Weon;Song, Geun Sung
    • Journal of Korean Neurosurgical Society
    • /
    • v.62 no.4
    • /
    • pp.450-457
    • /
    • 2019
  • Objective : Anterior cervical discectomy and fusion (ACDF) is commonly used surgical procedure for cervical degenerative disease. Among the various intervertebral spacers, the use of allografts is increasing due to its advantages such as no harvest site complications and low rate of subsidence. Although subsidence is a rare complication, graft collapse is often observed in the follow-up period. Graft collapse is defined as a significant graft height loss without subsidence, which can lead to clinical deterioration due to foraminal re-stenosis or segmental kyphosis. However, studies about the collapse of allografts are very limited. In this study, we evaluated risk factors associated with graft collapse. Methods : We retrospectively reviewed 33 patients who underwent two level ACDF with anterior plating using allogenous bone graft from January 2013 to June 2017. Various factors related to cervical sagittal alignment were measured preoperatively (PRE), postoperatively (POST), and last follow-up. The collapse was defined as the ratio of decrement from POST disc height to follow-up disc height. We also defined significant collapses as disc heights that were decreased by 30% or more after surgery. The intraoperative distraction was defined as the ratio of increment from PRE disc height to POST disc height. Results : The subsidence rate was 4.5% and graft collapse rate was 28.8%. The pseudarthrosis rate was 16.7% and there was no association between pseudarthrosis and graft collapse. Among the collapse-related risk factors, pre-operative segmental angle (p=0.047) and intra-operative distraction (p=0.003) were significantly related to allograft collapse. The cut-off value of intraoperative distraction ${\geq}37.3%$ was significantly associated with collapse (p=0.009; odds ratio, 4.622; 95% confidence interval, 1.470-14.531). The average time of events were as follows: collapse, $5.8{\pm}5.7months$; subsidence, $0.99{\pm}0.50months$; and instrument failure, $9.13{\pm}0.50months$. Conclusion : We experienced a higher frequency rate of collapse than subsidence in ACDF using an allograft. Of the various preoperative factors, intra-operative distraction was the most predictable factor of the allograft collapse. This was especially true when the intraoperative distraction was more than 37%, in which case the occurrence of graft collapse increased 4.6 times. We also found that instrument failure occurs only after the allograft collapse.

Validity and reliability of the Korean version of the Quality of Recovery-40 questionnaire

  • Lee, Jun Ho;Kim, Deokkyu;Seo, Donghak;Son, Ji-seon;Kim, Dong-Chan
    • Korean Journal of Anesthesiology
    • /
    • v.71 no.6
    • /
    • pp.467-475
    • /
    • 2018
  • Background: The Quality of Recovery-40 (QoR-40) is a widely-used, self-rated, and self-completed questionnaire for postoperative patients. The questionnaire is intended to elicit information from each patient regarding the quality of recovery during the postoperative period. It is noteworthy, however, that an official Korean version of the QoR-40 (QoR-40K) has not been established. The purpose of this study was to develop the QoR-40K by translation and cultural adaptation process and to evaluate the validity and reliability of the QoR-40K. Methods: After pre-authorization from the original author of the QoR-40, the translation procedure was established and carried out based upon Beaton's recommendation to create a QoR-40K model comparable to the original English QoR-40. Two hundred surgical patients were enrolled, and each completed the questionnaire during the preoperative period, on the third day, and 1 month after surgery. The QoR-40K was compared with the visual analogue scale (VAS) and another health-related questionnaire, the Short-form Health Survery-36 (SF-36). The method of validation for QoR-40K included test-retest reliability, internal consistency, and level of responsiveness. Results: Spearman's correlation coefficient for test-retest reliability was 0.895 (P < 0.001), and Cronbach's alpha of the global QoR-40K on the third day after surgery was 0.956. A positive correlation was obtained between the QoR-40K and the mental component summary of SF-36 (${\rho}=0.474$, P < 0.001), and a negative correlation was observed between QoR-40K and VAS (${\rho}=-0.341$, P < 0.001). The standardized responsive mean of the total QoR-40K was 0.71. Conclusions: The QoR-40K was found to be as acceptable and reliable as the original English QoR-40 for Korean patients after surgery, despite the apparent differences in the respective patients' cultural backgrounds.

Intraoperative Neurophysiological Monitoring and Neuromuscular Anesthesia Depth Monitoring (수술 중 신경계 추적 감시 검사와 근 이완 마취 심도의 측정)

  • Kim, Sang-Hun;Park, Soon-Bu;Kang, Hyo-Chan;Park, Sang-Ku
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.52 no.4
    • /
    • pp.317-326
    • /
    • 2020
  • Deep blocking of consciousness alone does not prevent a reaction to severe stimuli, and copious amounts of pain medication do not guarantee unconsciousness. Therefore, anesthesia must satisfy both: the loss of consciousness as well as muscle relaxation. Muscle relaxants improve the intra-bronchial intubation, surgical field of vision, and operating conditions, while simultaneously reducing the dose of inhalation or intravenous anesthesia. Muscle relaxants are also very important for breathing management during controlled mechanical ventilation during surgery. Excessive dosage of such muscle relaxants may therefore affect neurological examinations during surgery, but an insufficient dosage will result in movement of the patient during the procedure. Hence, muscle relaxation anesthesia depth and neurophysiological monitoring during surgery are closely related. Using excessive muscle relaxants is disadvantageous, since neurophysiological examinations during surgery could be hindered, and eliminating the effects of complete muscle relaxation after surgery is challenging. In the operation of neurophysiological monitoring during the operation, the anesthesiologist administers muscle relaxant based on what standard, it is hoped that the examination will be performed more smoothly by examining the trends in the world as well as domestic and global trends in maintaining muscle relaxant.

Treatment Methods for Functional Recovery after Total Knee Arthroplasty (슬관절 전치환술 후 기능 회복을 위한 치료법)

  • Kim, Young-mo;Joo, Yong-bum;Park, Il-young
    • Journal of the Korean Orthopaedic Association
    • /
    • v.55 no.2
    • /
    • pp.117-126
    • /
    • 2020
  • Total knee arthroplasty is performed widely in degenerative arthritis of the knee joint, and the frequency of use is increasing. Efforts should be made to achieve functional recovery, such as returning to daily life, and the recovery of strength and range of motion after surgery. The procedure should be approached from a range of perspectives, such as patient factors, surgical technique and rehabilitation. The patient's age, degree of obesity, sex, and strength of the quadriceps muscle can affect the functional recovery after surgery. In addition, the patient's mental state, such as expectation value and satisfaction, can also have an effect. For functional recovery, patient education, pain control, and strengthening of the quadriceps muscle can be performed prior to surgery. Postoperative physiotherapy, such as icing and compression, transcutaneous electrical nerve stimulation therapy, neuromuscular electrical stimulation therapy, low frequency low intensity magnetic field therapy, strengthening of quadriceps muscle, and range of motion exercise can also be applied. In recent years, hydrotherapy, which restores the strength and balance of the leg, is being performed increasingly. These treatments are not only performed shortly after surgery, but are also performed continuously. In addition, the surgeon should apply it appropriately considering the patient's condition, compliance, and social and psychological conditions.

Periimplant bone change after alveolar ridge preservation: radiographic retrospective study (발치와 치조제 보존술 후 식립한 임플란트 주위 골 변화: 후향적 방사선학적 분석)

  • Shim, Da-Eun;Pang, Eun-Kyoung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.3
    • /
    • pp.281-290
    • /
    • 2021
  • Purpose. The aim of this study is to evaluate bone change around the implant in patients who underwent alveolar ridge preservation for implantation in the posterior teeth using radiographic data measuring changes of mesial, distal crestal bone level according to post-implantation, post-final prosthesis delivery and follow-up periods. Materials and methods. In total, 36 implants were placed in 32 patients. The mesial and distal crestal bone level of all the areas where alveolar ridge preservation was performed uses panoramic images taken post-implantation, post-final prosthesis delivery, and follow-up period each was measured and evaluated as a vertical value. The following factors were analyzed: associations between changes of crestal bone level and factors (e.g., age, sex, systemic diseases, dentist, implant location, tooth, bone type, membrane). The statistical analysis was performed using the mean, standard deviation and independent t-test, paired t-test (P < .05). Results. Analysis of crestal bone level differences between periods shows statistically significant differences (P < .05). There was no statistically significant difference when the changes of crestal bone level between post-implantation, post-final prosthesis delivery and follow-up periods were correlated with each factors. Conclusion. After alveolar ridge preservation, bone around the implant remained stable during the maintenance period without being affected by the patient and surgical factors, and alveolar ridge preservation is considered a clinically usable procedure.

Prophylactic Intraoperative Nasolacrimal Duct Intubation in Surgical Treatment of Facial Fractures-Is There a Role?

  • Teoh, Ryan Liang Wei;Fong, Pei Yuan;Cai, Elijah Zhengyang;Yap, Yan Lin;Hing, Eileen Chor Hoong;Lee, Han Jing;Nallathamby, Vigneswaran;Ong, Wei Chen;Lim, Jane;Sundar, Gangadhara;Lim, Thiam Chye
    • Archives of Plastic Surgery
    • /
    • v.49 no.2
    • /
    • pp.195-199
    • /
    • 2022
  • Nasolacrimal duct (NLD) damage is associated in the majority of type II and III naso-orbito-ethmoid (NOE) fractures. Our study aims to investigate the efficacy and safety of prophylactic NLD intubation in the setting of facial fractures, by comparing incidence of postoperative epiphora and wound infection. A retrospective matched control study was conducted on all patients with surgically treated facial fractures from 2008 to 2013 (n=280) (IRB ref number: DSRB 2013/01198). Patients with the following fracture types were included: NOE (n=16), frontal sinus (n=2), Le Fort II/III (n=8), and > 1 type (n=48). All patients in this study were included with the intention to treat. The study group comprised patients who were intubated, while the control group patients were not intubated. Each group had 37 patients matched for age, gender, fracture type, and injury type. A single oculoplastic surgeon skilled in lacrimal surgery performed the procedure for all intubated patients. Patients with more severe and complex facial fractures were intubated with bicanalicular Crawford stents. Postoperative epiphora and infective complications (both facial wound and dacryocystitis) were assessed at 1, 3, 6, and 12 months. There was no significant difference in incidence of either postoperative epiphora (p=0.152) or wound infection (p=0.556) comparing both groups. Reduced incidence of postoperative epiphora in the study group is statistically not significant and does not support the need for prophylactic intubation. If radiographic evidence of NLD disruption or regurgitation seen on syringing on the NLD intraoperatively is present, intubation is safe and efficacious only if performed by an expert.

The impact of polydeoxyribonucleotide on early bone formation in lateral-window sinus floor elevation with simultaneous implant placement

  • Dongseob Lee;Jungwon Lee;Ki-Tae Koo;Yang-Jo Seol;Yong-Moo Lee
    • Journal of Periodontal and Implant Science
    • /
    • v.53 no.2
    • /
    • pp.157-169
    • /
    • 2023
  • Purpose: The aim of this study was to evaluate the impact of polydeoxyribonucleotide (PDRN) on histologic outcomes when implant placement and lateral sinus floor elevation are performed simultaneously. Methods: Three bimaxillary premolars (P2, P3, and P4) were extracted from 4 beagle dogs 2 months before lateral sinus floor elevation. After lateral elevation of the sinus membrane, each sinus was allocated to either the test or control group. Sinuses underwent either 1) collagenated synthetic bone graft with PDRN following lateral sinus floor elevation (test group) or 2) collagenated synthetic bone graft without PDRN after lateral sinus floor elevation (control group). Eight weeks after the surgical procedure, all animals were euthanised for a histologic and histomorphometric assessment. Augmented height (AH), protruding height (PH), and bone-to-implant contact in pristine (BICp) and augmented (BICa) bone were measured. The composition of the augmented area, which was divided into 3 areas of interest located in coronal, middle and apical areas (AOI_C, AOI_M, and AOI_A), was calculated with 3 parameters: the area percentage of new bone (pNB), residual bone graft particle (pRBP), and fibrovascular connective tissue (pFVT). Results: AH, PH, BICp, BICa total, BICa coronal, and BICa middle values were not significantly different between sinuses in the control and test groups (all P>0.05). The BICa apical of sinuses in the test group (76.7%±9.3%) showed statistically higher values than those of sinuses in the control group (55.6%±22.1%) (P=0.038). pNB, pRBP, and pFVT showed statistically significant differences between the 2 groups in AOI_A (P=0.038, P=0.028, and P=0.007, respectively). pNB, pRBP, and pFVT in AOI_C and AOI_M were not significantly different between samples in the control and test groups (all P>0.05). Conclusions: The histologic findings revealed that lateral sinus floor elevation with PDRN might improve early new bone formation and enable higher bone-to-implant contact.