• Title/Summary/Keyword: surgical instrument

Search Result 122, Processing Time 0.02 seconds

손동작 영상획득을 이용한 최소침습수술로봇 무구속 마스터 인터페이스 (Non-restraint Master Interface of Minimally Invasive Surgical Robot Using Hand Motion Capture)

  • 장익규
    • 대한의용생체공학회:의공학회지
    • /
    • 제37권3호
    • /
    • pp.105-111
    • /
    • 2016
  • Introduction: Surgical robot is the alternative instrument that substitutes the difficult and precise surgical operation; should have intuitiveness operationally to transfer natural motions. There are limitations of hand motion derived from contacting mechanical handle in the surgical robot master interface such as mechanical singularity, isotropy, coupling problems. In this paper, we will confirm and verify the feasibility of intuitive Non-restraint master interface which tracking the hand motion using infra-red camera and only 3 reflective markers without the hardware handle for the surgical robot master interface. Materials & methods: We configured S/W and H/W system; arranged 6 infra-red cameras and attached 3 reflective markers on hands for measuring 3 dimensional coordinate then we find the 7 motions of grasp, yaw, pitch, roll, px, py, pz. And we connected Virtual-Master to the slave surgical robot(Laparobot) and observed the feasibility. To verify the result of motion, we compare the result of Non-restraint master and that of clinometer (and protractor) through measuring 0~180 degree, 10degree interval, 1000 samples and recorded standard deviation stands for error rate of the value. Results: We confirmed that the average angle values of Non-restraint master interface is accurately corresponds to the result of clinometer (and protractor) and have low error rates during motion. Investigation & Conclusion: In this paper, we confirmed the feasibility and accuracy of 3D Non-restraint master interface that can offer the intuitive motion of non-contact hardware handle. As a result, we can expect the high intuitiveness, dexterousness of surgical robot.

Development of Tissue-Tool Interaction Simulation Algorithms for Rotator Cuff Surgery Scenario in Arthroscopic Surgery Training Simulator

  • Jo, Kyungmin;Bae, Eunkyung;You, Hyeonseok;Choi, Jaesoon
    • 대한의용생체공학회:의공학회지
    • /
    • 제41권4호
    • /
    • pp.154-164
    • /
    • 2020
  • Various simulator systems for surgery training have been developed and recently become more widely utilized with technology advancement and change in medical education adopting actively simulation-based training. The authors have developed tissue-instrument interaction modeling and graphical simulation algorithms for an arthroscopic surgery training simulator system. In this paper, we propose algorithms for basic surgical techniques, such as cutting, shaving, drilling, grasping, suturing and knot tying for rotator cuff surgery. The proposed method constructs a virtual 3-dimensional model from actual patient data and implements a real-time deformation of the surgical object model through interaction between ten types of arthroscopic surgical tools and a surgical object model. The implementation is based on the Simulation Open Framework Architecture (SOFA, Inria Foundation, France) and custom algorithms were implemented as pulg-in codes. Qualitative review of the developed results by physicians showed both feasibility and limitations of the system for actual use in surgery training.

VOSKIN 125+® instrument, a landmark in the history of massage; painkiller

  • Chang, Tae-soun
    • 셀메드
    • /
    • 제6권3호
    • /
    • pp.18.1-18.4
    • /
    • 2016
  • Patients often suffer from continuous pain negatively affecting their daily life despite a surgical operation. Various studies on complementary therapies against pain have been accumulated as patient with pain desires the improvement in quality of life. Massage therapy as a complementary therapy has been applied widely to decrease the pain and promote relaxation. Thermotherapy with massage is also useful for the treatment of musculoskeletal disorders. Here, the author reports that VOSKIN 125+®, a new massage instrument, was designed directly to be adjusted from 38-50 degrees Celsius depending on the individual symptoms by lifting the skin and muscles with a negative compression in illness area for alleviating all pain. It transfers pressure and heat to area of illness and eases the pain. In addition, it has significant anti-inflammatory effects and promotes metabolism activity. VOSKIN 125+® can be therapeutic for pain of musculoskeletal patients. Therefore, I suggest that VOSKIN 125+® can be useful for a great number of patients suffering from persisting pain.

Single-Port Thoracic Surgery: A New Direction

  • Ng, Calvin S.H.
    • Journal of Chest Surgery
    • /
    • 제47권4호
    • /
    • pp.327-332
    • /
    • 2014
  • Single-port video-assisted thoracic surgery (VATS) has slowly established itself as an alternate surgical approach for the treatment of an increasingly wide range of thoracic conditions. The potential benefits of fewer surgical incisions, better cosmesis, and less postoperative pain and paraesthesia have led to the technique's popularity worldwide. The limited single small incision through which the surgeon has to operate poses challenges that are slowly being addressed by improvements in instrument design. Of note, instruments and video-camera systems that are narrower and angulated have made single-port VATS major lung resection easier to perform and learn. In the future, we may see the development of subcostal or embryonic natural orifice translumenal endoscopic surgery access, evolution in anaesthesia strategies, and cross-discipline imaging-assisted lesion localization for single-port VATS procedures.

임상가를 위한 특집 1 - 컴퓨터 기반 악골 종양의 절제 및 재건술 (Computer-aided Maxillofacial ablation and reconstruction Surgery)

  • 문성용;임성훈
    • 대한치과의사협회지
    • /
    • 제52권10호
    • /
    • pp.596-601
    • /
    • 2014
  • Computer-aided surgery is popular and useful in the field of oral and maxillofacial surgery, because of the possibility of simulation with a high accuracy. In all aspects of surgery, proper planning facilitates more predictable operative results, however before the use of virtual planning, much of this relied on 2-dimensional (2-D) imaging for treatment planning on a 3-dimensional (3-D) object and surgical trial and error. With real-time instrument positioning and clear anatomic identification, a computer-assisted navigation system (CANS) is exceptionally helpful in maxillofacial surgery. These techniques enable performing precise bony ablation and reconstruction, and also decrease surgical time and donor site defect.

복강경 수술 로봇의 힘 반향을 위한 임피던스 모델 기반의 양방향 제어 (Impedance Model based Bilateral Control for Force reflection of a Laparoscopic Surgery Robot)

  • 윤성민;김원재;이민철
    • 제어로봇시스템학회논문지
    • /
    • 제20권8호
    • /
    • pp.801-806
    • /
    • 2014
  • LAS (Laparoscopy Assisted Surgery) has been substituted alternatively for traditional open surgery. However, when using a commercialized robot assisted laparoscopic such as Da Vinci, surgeons have encountered some problems due to having to depend only on information by visual feedback. To solve this problem, a haptic function is required. In order to realize the haptic teleoperation system, a force feedback and bilateral control system are needed. Previous research showed that the perturbation value estimated by a SPO (Sliding Perturbation Observer) followed a reaction force that loaded on the surgical robot instrument. Thus, in this paper, the force feedback problem of surgical robots is solved through the reaction force estimation method. This paper then introduces the possibility of the haptic function realization of a laparoscopic surgery robot using a bilateral control system. For bilateral control, the master uses an impedance control and the slave uses a SMC (Sliding Mode Control). The experiment results show that a torque and force sensorless teleoperation system can be implemented using a bilateral control structure.

위해사건 예방을 위한 수술 환자 교육용 스마트폰 애플리케이션의 효과 (The Effects of Smartphone Application to Educate Patient on Patient Safety in Hospitalized Surgical Patients)

  • 최효진;이은주
    • 성인간호학회지
    • /
    • 제29권2호
    • /
    • pp.154-165
    • /
    • 2017
  • Purpose: This study was designed to evaluate a patient safety application in the prevention of adverse event among surgical patients. Seventy three surgical patients with thirty six of them using the patient safety application and the rest (N=37) were provided educational booklet. Further, the instrument would measure patients' right to know, knowledge about patient safety, and attitude toward patient safety. Methods: The patient safety application was developed by the ADDIE along with input from experts, patients and an extensive literature review. Data were collected from 7 September through 20 October 2015. Results: The experimental group had significantly higher scores in patients' right to know (t=2.01, p=.024), knowledge on patient safety (t=3.80, p<.001) and attitude toward patient safety (t=2.74, p=.004) than those of the control group. Conclusion: The patient safety application developed using Smartphone could be an effective tool enhancing patient involvement in preventing adverse events that may occur to patients. Further studies are recommended with diverse subjects with varying medical conditions.

설소대단축증의 수술적 방법에 따른 비교 (A Comparison Study of the Surgical Outcome According to the Surgical Technique)

  • 홍원표;서용석;송미현;양해동;김성수
    • 대한후두음성언어의학회지
    • /
    • 제14권1호
    • /
    • pp.10-15
    • /
    • 2003
  • Background and Objectives : Ankyloglossia, commonly known as tongue-tie, is the result of a short, fibrous lingual frenulum or highly attached geioglossus muscle. This condition may cause sucking and swallowing problems, articulation disorders, interference with the tongue's cleansing action, increased the potential for caries, and inability to lick the lips, play a wind instrument, and 'french kiss' Treatment is surgical procedure. In the most cases, horizontal sectioning and mucosal suture(the conventional procedure) is preferred, but in some cases, the Z-plastic procedure is effective. This study is aimed to compare the result of the two procedures. Materials and Methods : Twenty tongue-tie patients underwent operation. Ten patients were treated with the Z-plastic procedure and ten patients were treated with the conventional method randomly. We checked preoperative mobile tongue length, postoperative mobile tongue length, operation time and postoperative wound states. Results : Among the 20 cases of tongue-tie, 2 cases are excepted due to pre-operative state, thus we compared 18 cases of tongue-tie patients. There is no statistically significant difference between the two procedures except in operation time. The Z-plastic procedure apparently needs a little more operating time. Conclusion : Patients treated with the Z-plastic procedures appeared to have better outcomes, but the data shows no statistical significance except in operating time. Consequently, the Z-plastic procedure is indicated in a limited amount of cases.

  • PDF

Minimally traumatic extraction of fractured bilateral maxillary canine teeth using a piezoelectric surgical unit in an African lion (Panthera leo)

  • Se Eun Kim;Yoocheol Jeong
    • Journal of Veterinary Science
    • /
    • 제25권4호
    • /
    • pp.50.1-50.6
    • /
    • 2024
  • Importance: Canine extraction of large carnivores can pose significant risk due to extensive tissue damage during aggressive bone reduction. This report highlights a rare instance in which the use of a piezoelectric surgical unit (PSU) for maxillary canine extraction in a large carnivore resulted in successful outcomes with minimal tissue damage. Case presentation: A 10-year-old male African lion presented with decreased appetite because of bilateral maxillary canine fractures. Intraoral radiographs revealed enlarged root canals and periapical radiolucency of the fractured canines, leading to a diagnosis of periapical periodontitis and pulpitis. To extract the right maxillary canine, conventional method using hand instrument failed to achieve adequate luxation, necessitating the use of the flat blade of the PSU to sever the periodontal ligament. The left maxillary canine was extracted using PSU from the beginning, and the extraction time was markedly shortened by using PSU without additional alveolar bone damage or bleeding. Conclusion and Relevance: This case demonstrated that utilizing PSU for canine extraction in a lion resulted in periodontal ligament separation, reducing damage to the alveolar bone and shortening surgical time. It suggests the promising application of PSU in tooth extraction for large wild animals, indicating its potential significance in veterinary dentistry.

Fracture incidence of Reciproc instruments during root canal retreatment performed by postgraduate students: a cross-sectional retrospective clinical study

  • Liliana Machado Ruivo;Marcos de Azevedo Rios;Alexandre Mascarenhas Villela;Alexandre Sigrist de Martin;Augusto Shoji Kato;Rina Andrea Pelegrine;Ana Flavia Almeida Barbosa;Emmanuel Joao Nogueira Leal Silva;Carlos Eduardo da Silveira Bueno
    • Restorative Dentistry and Endodontics
    • /
    • 제46권4호
    • /
    • pp.49.1-49.8
    • /
    • 2021
  • Objectives: To evaluate the fracture incidence of Reciproc R25 instruments (VDW) used during non-surgical root canal retreatments performed by students in a postgraduate endodontic program. Materials and Methods: From the analysis of clinical record cards and periapical radiographs of root canal retreatments performed by postgraduate students using the Reciproc R25, a total of 1,016 teeth (2,544 root canals) were selected. The instruments were discarded after a single use. The general incidence of instrument fractures and its frequency was analyzed considering the group of teeth and the root thirds where the fractures occurred. Statistical analysis was performed using the χ2 test (p < 0.01). Results: Seven instruments were separated during the procedures. The percentage of fracture in relation to the number of instrumented canals was 0.27% and 0.68% in relation to the number of instrumented teeth. Four fractures occurred in maxillary molars, 1 in a mandibular molar, 1 in a mandibular premolar and 1 in a maxillary incisor. A greater number of fractures was observed in molars when compared with the number of fractures observed in the other dental groups (p < 0.01). Considering all of the instrument fractures, 71.43% were located in the apical third and 28.57% in the middle third (p < 0.01). One instrument fragment was removed, one bypassed, while in 5 cases, the instrument fragment remained inside the root canal. Conclusions: The use of Reciproc R25 instruments in root canal retreatments carried out by postgraduate students was associated with a low incidence of fractures.