• 제목/요약/키워드: surge characteristics

검색결과 460건 처리시간 0.037초

ZnO 나노분말로 제조한 Bi계 바리스터의 써지내량 특성 (Characteristics on the Surge Capability of Bi-based Varistor Fabricated with ZnO Nano-powder)

  • 왕민성;박춘배
    • 한국전기전자재료학회논문지
    • /
    • 제19권9호
    • /
    • pp.862-867
    • /
    • 2006
  • Bi-based nano-varistors and micro-varistors fabricated with each ZnO nano-powder and micro-powder were studied about characteristics on the surge capability in this study. ZnO nano-varistors were sintered in air at $1050^{\circ}C$ for 2 hr. The voltage-current and residual voltage properties of ZnO nano-varistor were compared with their of ZnO micrio-varistor. As a result of these properties, our ZnO nano-varistor has about 3 times at operating voltage as compared with conventional ZnO varistor fabricated with micro-powder and the residual voltage was 8.06 kV at nominal discharge current 101kA in the lighting impulse current test. And then the residual voltage rate 1.72 of our nano-varistor has had better performance than the 1.79 of micro-varistor because ZnO nano-varistor has shown much quick response property because of increasing effective cross-section area. Also, to analysis surge capability took thermal images for pyrexia temperature distribution with each of the varistors after operating varistors. Nano-varistor doesn't have shown local overheating and can confirm accurate temperature grade on the surface of its.

배전급 피뢰기(18kV, 5kA)용 ZnO 바리스터 소자 개발 (Development of ZnO Varistor for Distribution Surge Arrester (18kV, 5kA))

  • 박춘현;윤관준;조이곤;정세영;서형권
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 추계학술대회 논문집
    • /
    • pp.212-216
    • /
    • 2000
  • ZnO varistors for distribution surge arrester (18kV, 5kA) were developed and tested microstructure and electrical characteristics. Microstructure of ZnO varistor was consisted of ZnO grain, spinel phase and Bi-rich phase. Average grain size of ZnO varistor was $\mu\textrm{m}$ Reference voltage and lightning impulse residual voltage of ZnO varistor exhibited a good haracteristics above 5.5kV and below 11.56kV, respectively. Consequently, discharge capacity which is the most important characteristics of ZnO varistor for surge arrester exhibited excellent properties above 70kA at twice high-current impulse test. Moreover, variation rate of reference voltage and lightning impulse residual voltage showed below 5% and 2% after high-current impulse test, respectively. Leakage current and watt loss of ZnO varistor will not increase during accelerated aging test at stress condition, such as 3.213kV/$115^{\circ}C$/1000h.

  • PDF

대형 자동차 하이브리드 유압 구동시스템의 회로구성과 특성해석에 관한 연구 (A Study on the Circuit Composition and Characteristics Analysis for Heavy-Duty Vehicular Hybrid Hydraulic Driving System)

  • 이재구;이재천;한문식
    • 한국자동차공학회논문집
    • /
    • 제12권2호
    • /
    • pp.197-204
    • /
    • 2004
  • An accumulator in hydraulic systems stores kinetic energy during braking action, and then that controls hasty surge pressure. An energy recovery system using accumulator seems to be advantageous for ERBS due to its high energy density. This study suggests a method to decide suitable accumulator volume for ERBS. The method is based upon energy conservation between kinetic energy of moving inertia and elastic energy of accumulator. The energy conversion was analyzed and a simple formula was derived. Also accumulator tests were conducted for different load mass and motor speed. A series of test work were carried out in the laboratory and the dynamic characteristics of the hydraulic motor system, such as the surge pressure and response time, were investigated in both brake action and acceleration action and these results show that the proposed design is effective for decision accumulator volume in ERBS.

가스절연송전선로의 서지특성 분석에 관한 연구 (A Study on Analysis of Surge Characteristics on Gas Insulated Transmission Lines)

  • 정채균;박흥석;강지원;장태인;윤종건;김양상;석광현;김형호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.371_372
    • /
    • 2009
  • This paper describes surge characteristics on 345kV combined transmission system mixed overhead line and GIL(Gas Insulated Transmission Line). Then, it is compared with the results of the system mixed overhead line and XLPE power cables. Finally the lightning overvoltages are also discussed according to surge arrester installation in two kinds of combined transmission systems when the lighting strikes on the phase conductor.

  • PDF

ZnO 세라믹 바리스터의 미세구조에 미치는 $TiO_2$의 영향 (Influence of $TiO_2$ Addition on Microstructure of ZnO Ceramic Varistor)

  • 소병문;홍진웅
    • 한국전기전자재료학회논문지
    • /
    • 제11권3호
    • /
    • pp.214-220
    • /
    • 1998
  • ZnO varistors are characterized by the features of excellent nonlinearity and surge withstand capability. In this paper, in order to investigate the use of ZnO varistor as surge absorption device in low voltage, metal oxide material($TiO_2$) was selected as control material of grain growth. Samples of ZnO varistors were fabricated with varying the contents, and then the microstructures and V-I characteristics were measured. It was observed by SEM that the mean grain size increased with the increase of the additive. From the measurement of V-I characteristics, it was observed that according to the increase of the quantity of $TiO_2$ as additive, the operating voltage was lowered.

  • PDF

인공위성 추력기 작동에 따른 배관 내 유동해석 (A Fluid Analysis for Propellant Feed System as Thruster Valve Operation)

  • 유명종;김수겸;이균호;최준민
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2006년 제4회 한국유체공학학술대회 논문집
    • /
    • pp.45-46
    • /
    • 2006
  • Usual LEO satellite for earth observation use a blowdown hydrazine monopropellant propulsion system for attitude hold and orbit maintenance. For precision control, thruster valve has very short closing time, but this can cause water hammering and pressure surge. Since water hammering and pressure surge can cause damage of propulsion system and ununiform thrust, Thruster valve closing is one of the special concern during satellite propulsion system design. In this paper, an analysis for propellant feed system is conducted using the method of characteristics. The results represent water hammer effect is negligible even at the worst case and pressure surge can be decreased effectively with a trim orifice.

  • PDF

송전선로 피뢰기 적용 및 외부 갭형과 갭레스형의 동작특성 비교 (Comparison on Characteristics between air-gap type and gapless In transmission LA)

  • 유희영;김종채;김병헌;박윤석;이봉희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.347-348
    • /
    • 2008
  • This paper presents the use of Line Surge Arresters on 154kV double circuit lines. The ouatge rate which is highly related to the tower footing resistance is showed during the last a few year. The general methods that have been adopted at lines also are introduced. Lightning performance of lines without and with line surge arrester is studied and compared. The characteristics between air-gap type and gapless type LSA also compared. Line surge arrester installation strategy is presented.

  • PDF

발변전급 피뢰기용 산화아연소자의 AC 가속열화특성 (AC Accelerated Ageing Characteristics of Zinc Oxide Varistors for the Station Class Lightning Surge Arresters)

  • 조한구;윤한수;김석수;한동희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 추계학술대회 논문집 Vol.18
    • /
    • pp.315-316
    • /
    • 2005
  • This paper describes the AC accelerated ageing characteristics of zinc oxide varistors for the station class lightning surge arresters. ZnO varistors whose rated voltage were 3.27kV, 4.00kV, and 6.00kV were manufactured with general ceramic production methods. The power loss of sample A varistors rapidly increased and eventually showing the thermal run-away, but sample B and sample C varistors exhibited negative creep phenomena in power losses during the test.

  • PDF

밀림곡관 맞대기 용접부의 잔류응력 특성 평가 (Evaluation of Welding Residual Stress Characteristics of a Surge Line Elbow)

  • 한창기;장윤석;김만원;이경수
    • 한국압력기기공학회 논문집
    • /
    • 제11권1호
    • /
    • pp.45-52
    • /
    • 2015
  • Even though a lot of efforts have been devoted to evaluate welding residual stress characteristics of nuclear components, from the view point of accuracy, there are still some arguments in application of engineering estimation schemes. In this paper, three-dimensional finite element analyses (FEA) were carried out to predict residual stress distributions in butt welds of a typical surge line piping. Mesh optimization was conducted and subsequent analysis results such as the axial and hoop stress components along the weld center line and inner wall. Moreover, alternative evaluation was conducted by using three representative equations and their results were compared to those of FEA. Thereby, key parameters affecting to temperature profiles and residual stress distributions were derived as well as an optimum engineering estimation scheme was recommended.

인버터에 의한 가변속 구동장치의 스위칭 써지 특성 분석 (The Analysis for the Characteristics of Switching Surge of Adjustable Speed Drive by Inverter)

  • 송승엽;김재철;이도훈;신중은;임태훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.241-243
    • /
    • 2003
  • By development of power electronics technology, the increasing of inverter's switching frequency lead to the development of speed control technology of induction motor. But the surge voltage including harmonic component in output waveform can cause the motor to generate power losses, torque ripple, acoustic noise and oscillation. This paper is analyzed the characteristics for switching surge of adjustable speed drive and is presented the problem by inverter.

  • PDF