• Title/Summary/Keyword: surfaces

Search Result 9,417, Processing Time 0.042 seconds

Shear bond strength of ceramic and resin brackets used with visible light-cured adhesives (도재 및 레진 브라켓에 대한 광중합 접착제의 전단 접착 강도)

  • Hwang, Yu-Sun;Row, Joon;Hwaang, Chung-Ju
    • The korean journal of orthodontics
    • /
    • v.26 no.2 s.55
    • /
    • pp.233-244
    • /
    • 1996
  • The purpose of this study was to compare the shear bond strength obtained from ceramic and plastic brackets bonded with various light-cured adhesives and to evaluate their debonded failure sites. Plastic brackets, Transcend 6000, Signature and Starflre TMB brackets were bonded with Orthobond, Light Bond and Transbond on one hundred forty extracted human premolar teeth as manufacturer's descriptions. After thermocycling the brackets were debonded with an Instron universal testing machine and the debonded bracket base surfaces were inspected under stereoscope to evaluate the failure sites. Also the shear bond strength and failure patterns with different curing time and with two different source of light were compared. The results were as follows. 1. There were no statistically significant differences among the mean shear bond strength of Orthobond, Light Bond and Transbond in a same bracket group except Plastic bracket group(p<0.05). 2. The mean shear bond strength of each adhesive with different bracket groups showed statistically significant differences. Stafire TMB showed the highest shear bond strenght among the brackets in this study, but there was no statistically singnificant difference with Transcend 6000 while there was statistically significant difference with Signature.(p<0.05) 3. The various bonding failure patterns were occurred among different bracket groups but most of failure sites were bracket base -adhesive interfaces. 4. There were no statistically significant differences in shear bond strength between the groups with curing time of 10 second and 20 second, and between the groups with two different sources of light as long as sufficient light intensity(above $400mWcm^2$) were provided(p<0.05). According to the result, it should be considered in clinical use of ceramic bracket with light-cured adhesives that the shear strengths of ceramic brackets were influenced by the retention from of bracket base as well as the composition of bracket and there was no difference in the shear bond strenght among various light-cured adhesives used in this study.

  • PDF

A histomorphometric study on the effect of surface treatment on the osseointegration (티타늄 임플란트의 표면처리가 골유착에 미치는 영향에 관한 조직형태계측학적 연구)

  • Choi, Woong-Jae;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.4
    • /
    • pp.445-456
    • /
    • 2009
  • Statement of problem: Many studies have been conducted to improve the primary stability of implants by providing bioactive surfaces via surface treatments. Increase of surface roughness may increase osteoblast activity and promote stronger bonding between bone and implant surface and it has been reported that bioactive surface or titanium can be obtained through alkali and heat treatment. Purpose: The purpose of this study was to evaluate the stability of alkali and heat treated implants via histomorphometric analysis. Material and methods: Specimens were divided into three groups; group 1 was the control group with machined surface, the other groups were treated for 24 hours in 5 M NaOH solution and heat treated for 1 hour at $600^{\circ}C$ in the atmosphere (group 2) and vacuum (group 3) conditions respectively. Surface characteristics were analyzed and fixtures were implanted into rabbits. The specimens were histologically and histomorphometrically compared according to healing periods and change in bone composition were analyzed with EPMA (Electron Probe Micro Analyzer). Results: 1. Groups treated with alkali and heat showed increase of oxidization layer and Na ions. Groups 2 which was heat treated in atmosphere showed significant increase of surface roughness (P<.05). 2. Histomorphometric analysis showed significant increase in BIC (bone to implant contact) according to increase in healing period and there was significant increases in groups 2 and 3 (P<.05). 3. BA(bone area) ratio showed similar results as contact ratio, but according to statistical analysis there was significant increase according to increase in healing period in group 2 only (P<.05). 4. EPMA analysis revealed no difference in gradation of bone composition of K, P, Ca, Ti in surrounding bone of implants according to healing periods but groups 2 and 3 showed increase of Ca and P in the initial stages. Conclusion: From the results above, it can be considered that alkali and heat treated implants in the atmosphere have advantages in osseointegration in early stages and may decrease the time interval between implantation and functional adaptation.

EFFECT OF LASER IRRADIATION AND FLUORIDE APPLICATION ON REMINERALIZATION OF ERODED PRIMARY DENIAL ENAMEL (침식된 유치 법랑질에 대한 레이저 조사 및 불소도포의 재광화 효과)

  • Yang, Young-Sook;Kim, Dae-Eup;Ra, Ji-Young;Lee, Kwang-Hee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.2
    • /
    • pp.262-268
    • /
    • 2006
  • The purpose of this in vitro study was to evaluate the remineralizing effects of Nd : YAG laser irradiation and fluorides application on primary tooth enamel eroded by acidic drink. The materials were 30 sound primary teeth with intact smooth enamel surfaces. They were demineralized with Coca-cola at $37^{\circ}C$ for 12 hours and then irradiated by Nd: YAG laser with 6W power, $50mJ/cm^2$ energy density. and 20Hz pulse repetition. After laser irradiation, teeth were treated by three kinds of fluorides : (1) 0.05% NaF solution, (2) 1.23% APF gel and (3) 0.1% fluoride varnish. Diagnodent scores and microhardness (VHN) were measured before and after the each treatment. The results were as follows: 1. Diagnodent scores decreased to 23.51% from the initial after demineralization, and then increased to 37.37% after laser irradiation, and to 51.34% after fluoride treatment. There were significant differences between the total scores of initial, demineralization, laser irradiation and fluoride treatment (P<0.05). There was no significant difference between scores after fluoride treatment according to fluoride types. 2. Microhardness(VHN) decreased to 33.58% from the initial after demineralization and then increased to 43.99% after laser irradiation, and to 51.38% after fluoride treatment. There were significant differences between the total scores of initial, demineralization, laser irradiation and fluoride treatment (P<0.05). There was no significant difference between scores after fluoride treatment according to fluoride types.

  • PDF

A STUDY OF THE EFFECT OF CHEMO-MECHANICAL CARIES REMOVAL SYSTEM ON THE REMOVAL OF CARIOUS DENTIN AND RESIN ADHESION TO DENTIN (화학제재를 이용한 우식상아질 제거효과 및 레진과의 결합강도에 관한 연구)

  • Kang, Dug-Il;Park, In-Chon;Lee, Nan-Young;Lee, Sang-Ho;Lee, Chang-Seop
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.4
    • /
    • pp.581-592
    • /
    • 2003
  • The aim of this study was to evaluate the effect of chemo-mechanical caries removal system($Carisolv^{TM}$, Medi Team, Sweden) for resin adhesion to carious primary and permanent dentin compared with conventional drilling method. The buccal surface of 92 primary molars and 92 permanent molars were used. Exposed dentins were occurred artificial caries. 32 tooth of primary molars and 32 tooth of permanent molars were prepared to observe treated dentin surface with $Carisolv^{TM}$ and conventional drilling method by SEM. Other tooth were prepared to measure resin-dentin shear bonding strength according to caries removal methods and dentin adhesive system. Two adhesive systems and a composite resin were used; single bonding agent(Scotchbond Multi-Purpose Plus, 3M) and self-etching bonding system(Prompt L-pop, 3M ESPE), and a composite resin (Z-250, 3M). The results were as follows : 1. The removal effect of carious dentin on $Carisolv^{TM}$ was stronger on the primary dentin than that to permanent dentin, and dentin surface became rougher with treated $Carisolv^{TM}$ than drilling method. 2. Acid-etched dentin surfaces were showed smoothening without smear layer. 3. In specimen applied single bonding system hybrid layer and adhesive layer were $2-4{\mu}m$ and $10-15{\mu}m$ in thickness, whereas self-etching bonding system were showed only thin hybrid layer($1-2{\mu}m$). 4. The shear bonding strength of group applied single bonding agent was higher than that applied self-etching priming system(P<0.05). 5. The shear bonding strength of group applied $Carisolv^{TM}$ and self-etching priming system were slightly higher than that applied conventional drilling method and self-etching priming system(P>0.05).

  • PDF

THE INFLUENCE OF SALIVARY CONTAMINATION ON SHEAR BOND STRENGTH OF PIT AND FISSURE SEALANT BY USE OF SEVERAL BONDING AGENTS (타액오염이 치면열구전색제의 전단결합강도에 미치는 영향)

  • Park, So-Yeon;Choi, Sung-Chul;Choi, Young-Chul;Kim, Kwang-Chul;Park, Jae-Hong
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.39 no.2
    • /
    • pp.153-159
    • /
    • 2012
  • The objective of this study was to assess the effect of salivary contamination on shear bond strength of pit and fissure sealant using several bonding agents by means of applying saliva at different stages of treatment. 56 teeth were randomly divided into one of seven groups (8 per group): (Group A, B) acid etching; (Group C, D, E) Adper$^{TM}$ Single Bond after acid-etching; (Group F, G) Adper$^{TM}$ Prompt L-pop. Saliva was applied to teeth surface of B, D, E, and G groups for 10 seconds. Especially, group D was contaminated after acid-etching and group E was contaminated with saliva after adhesive application. After light curing, all of the specimens were thermocycled and the shear bond strength tests were performed. The results were as follows. 1. In generally performed pit and fissure sealant group, shear bonding strength significantly differently reduced when was contaminated by saliva (p<0.05). However the group that was applied with bonding agent during pit and fissure sealant procedure, there were no significant differences in the kind of bonding agents nor the stage of contamination. 2. In group that was not contaminated by saliva during pit and fissure sealant treatment, Adper$^{TM}$ Single Bond yielded the highest bonding strength but there were no significant differences. 3. The failure pattern on the debonded surfaces shows that most specimens from groups using bonding agents showed cohesive failures while most specimens from groups that didn't use bonding agents showed adhesive failures.

AN EXPERIMENTAL STUDY ON THE MICROTENSILE BONDING STRENGTH OF DENTIN TREATED BY $CARISOLV^{TM}$ ($Carisolv^{TM}$ 에 의한 우식제거후 Microtensile Bonding Strength에 관한 연구)

  • Baik, Byeong-Ju;Kwon, Byoung-Woo;Kim, Jae-Gon;Cheon, Cheol-Wan
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.29 no.3
    • /
    • pp.389-396
    • /
    • 2002
  • The purpose of this study was to compare the microtensile bonding strength of chemomechanically excavated dentin($Carisolv^{TM}$) to conventional caries removal(bur). The following adhesive systems were used; AB: All-Bond 2(3M, USA), PB: Prime & Bond 2.1(Dentsply, DE), AQ: AQ Bond(sun medical, Japan). 42 human molars with occlusal caries were assigned to 6 groups. Sequential caries removal was controlled with laser fluorescence. Each group was devided as follows; group A, B, C were $Carisolv^{TM}$ applied, group D,E,F were bur used. In group A and D, AB was used as a dentin adhesive. group B,E and group C,F was AQ and AQ was used each. The cavity was filled with composite resin(Z-100). The specimens were sectioned vertically into multiple serial 0.7 mm thick slabs. And then those slabs were sectioned into rectangular parts under 0.7 mm width. Finally 0.7-1.0 mm a right hexahedron shape stick become. Microtensile bonding test was carried out with testing apparatus at cross-head speed of $0.5\;mm/min^{-1}$ and fractured surfaces were observed with scanning electron microscope(JSM-6400, Jeol, Japan). The obtained results were summarized as follows ; 1. In the group of caries removal with $Carisolv^{TM}$, micro-tensile bonding strength decreased to $75.8{\sim}80$ percent of bur used group. 2. In the group of caries removal with $Carisolv^{TM}$, decreased degree of micro-tensile bonding strength is not so different in 3 kinds of dentin adhesives(p<0.05). 3. In the group of caries removal with $Carisolv^{TM}$, microtensile bonding strength of AB, PB, AQ was 32.6MPa(2.4), 30.1Mpa (1.8), 21.2Mpa(1.9). 4. In the group of caries removal with Bur and $Carisolv^{TM}$, microtensile bonding strength of AQ was significantly lower than that of AB and PB(p<0.01).

  • PDF

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2013 (설비공학 분야의 최근 연구 동향 : 2013년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.12
    • /
    • pp.605-619
    • /
    • 2014
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2013. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of fluid machinery, pipes and relative parts including orifices, dampers and ducts, fuel cells and power plants, cooling and air-conditioning, heat and mass transfer, two phase flow, and the flow around buildings and structures. Research issues dealing with home appliances, flows around buildings, nuclear power plant, and manufacturing processes are newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for general analytical model for desiccant wheels, the effects of water absorption on the thermal conductivity of insulation materials, thermal properties of Octadecane/xGnP shape-stabilized phase change materials and $CO_2$ and $CO_2$-Hydrate mixture, effect of ground source heat pump system, the heat flux meter location for the performance test of a refrigerator vacuum insulation panel, a parallel flow evaporator for a heat pump dryer, the condensation risk assessment of vacuum multi-layer glass and triple glass, optimization of a forced convection type PCM refrigeration module, surface temperature sensor using fluorescent nanoporous thin film. In the area of pool boiling and condensing heat transfer, researches on ammonia inside horizontal smooth small tube, R1234yf on various enhanced surfaces, HFC32/HFC152a on a plain surface, spray cooling up to critical heat flux on a low-fin enhanced surface were actively carried out. In the area of industrial heat exchangers, researches on a fin tube type adsorber, the mass-transfer kinetics of a fin-tube-type adsorption bed, fin-and-tube heat exchangers having sine wave fins and oval tubes, louvered fin heat exchanger were performed. (3) In the field of refrigeration, studies are categorized into three groups namely refrigeration cycle, refrigerant and modeling and control. In the category of refrigeration cycle, studies were focused on the enhancement or optimization of experimental or commercial systems including a R410a VRF(Various Refrigerant Flow) heat pump, a R134a 2-stage screw heat pump and a R134a double-heat source automotive air-conditioner system. In the category of refrigerant, studies were carried out for the application of alternative refrigerants or refrigeration technologies including $CO_2$ water heaters, a R1234yf automotive air-conditioner, a R436b water cooler and a thermoelectric refrigerator. In the category of modeling and control, theoretical and experimental studies were carried out to predict the performance of various thermal and control systems including the long-term energy analysis of a geo-thermal heat pump system coupled to cast-in-place energy piles, the dynamic simulation of a water heater-coupled hybrid heat pump and the numerical simulation of an integral optimum regulating controller for a system heat pump. (4) In building mechanical system research fields, twenty one studies were conducted to achieve effective design of the mechanical systems, and also to maximize the energy efficiency of buildings. The topics of the studies included heating and cooling, HVAC system, ventilation, and renewable energies in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment is mostly focused on indoor environment and building energy. The main researches of indoor environment are related to infiltration, ventilation, leak flow and airtightness performance in residential building. The subjects of building energy are worked on energy saving, operation method and optimum operation of building energy systems. The remained studies are related to the special facility such as cleanroom, internet data center and biosafety laboratory. water supply and drain system, defining standard input variables of BIM (Building Information Modeling) for facility management system, estimating capability and providing operation guidelines of subway station as shelter for refuge and evaluation of pollutant emissions from furniture-like products.

Ultrastructural Changes of the Vas Deferens Epithelium by Season in a Slug Incilaria fruhstorferi (산민달팽이(Incilaria fruhstorferi) 수정관 내강 상피조직의 계절에 따른 미세구조적 변화)

  • 장남섭;정계현;한종민
    • The Korean Journal of Zoology
    • /
    • v.39 no.4
    • /
    • pp.400-409
    • /
    • 1996
  • A study on the ultrastructural changes In the epithellum of the vas deferens by season was conducted for the spdng and summer specimens of a slug Incilarfa fruhstoiferl. The vas deferens of the spdng spedmen was muscular tube about 0.4mm in diameter. Its lumen was divided into three flat grooves and the each groove was subdivided into two subbranches. The luminal epithellal celis of the Vas deferens which were irregular In shape showed strong methylenophilla in a double stain of methylene blue and basic fuchsln. The lumen of the vas deferens was filled with components strongly stained by methylene blue. The circular muscle layers surrounding the luminal epithellum of the vas deferens contained numerous granules arranged at regular intervals. The vas deferens of the summer specimen also was a thick muscular tube showing 0.4 mm in diameter. Its lumen was divided into four grooves but, the each of the grooves was not subdivided to form certain branclees unlikely to the spdng spedmen. The lining epfthelium of the lumen was consisted of simple ciliated columnar cells, irregular columnar cells and conical cells. The histological features were quiet different from those of the spring spedmen which showed irregular cell arrangement. According to electron microscopy the epithelium of the vas deferens in the spring specimen was composed of irregular columnar cells which had irregular shaped nuclei. The nuclei of the epitheilal cells were relatively large in comparison to their cytoplasm. The overall electric density of the cytoplasm was relatively high. The lumen of the vas deferens in the summer specimen was lined by a epfthelium with tail ciliated columnar cells and irregular cells. The unclei of the epithellal cells were long ellipsoid or irregular in shape. Both of the cytoplasm and the nuclei were showed low electric density. in consideration with the observable cell organelles were only ndoplasmic reticulum, lysosomes and microtutules, the cell organelles were poorly developed. The apical surfaces of the epithelial cells possessed brush borders with numerous microvilli and cilia with 9+2 arrangement of microtubules. The circular muscle layers surrounding the epithelium are usually thick and the degree of development of the circular muscle layers seems to be even in the both of the spring and summer specimens.

  • PDF

Epidermal Structure and Stomatal Types in Some Species of Korean Crassulaceae (한국산 돌나물과(Crassulaceae) 수종의 표피구조와 기공유형)

  • Jeong, Woo-Gyu;Sung, Min-Wung
    • Journal of Plant Biology
    • /
    • v.28 no.2
    • /
    • pp.105-118
    • /
    • 1985
  • This study was carried out to investigate the epidermal structure and types of stomata on the upper and lower surfaces of the leaves in six species and one variety belonging to Korean Crassulaceae. The shape of epidermal cells was polygonal, isodiametric, or elongated. The cell wall was thick, sinuous or deeply sinuous. The subsidiary cell wall was thin or mostly arched. The cytolith-containing cells were found in Orostachys japonicus. The distribution of stomata was more on the upper surface than on the lower surface in the leaves of O. japonicus and Sedum sarmentosum. The stomata in the other species were less on the upper surface than on the lower surface, and stomatal size was different in each species. The great majority of stomatal types was the helico-eumesogenous type. This type was subdivided into two, parahelico-eumesogenous type and diahelico-eumesogenous type by us on the basis of the angle of division of guard mother cell and the long axis of the last-formed subsidiary cells. Sometimes allelo-eumesogenous type as well as aniso-eumesogenous type was found. The tetra-eumesogenous type with four mesogenous subsidiary cells was rarely observed. It was observed that the varieties of aniso-eumesogenous type with one to three subsidiary cells and one helix of subsidiary cells were developed by the secondary division of subsidiary cells of aniso-eumesogenous stoma. The compound shape of helico-eumesogenous stomata was found. Five new kinds of stomatal types were observed as follows; the helico-tetra-eumesogenous type, the coallelohelico-eumesogenous type, the cohelico-allelo-eumesogenous type, the duplotetra-eumesogenous type, and the aniso-euperigenous type. These types were reported here in the vascular plants for the first time.

  • PDF

ORTHODONTIC BRACKET SHEAR BOND STRENGTH TO Nd:YAG LASER Er:YAG LASER IRRADIATED ENAMEL (Nd : YAG 및 Er : YAG 레이저로 치아표면 조사시 브라켓 전단접착강도에 관한 실험적 연구)

  • Choi, Seung-Hoon;Yang, Won-Sik
    • The korean journal of orthodontics
    • /
    • v.27 no.1
    • /
    • pp.141-155
    • /
    • 1997
  • The purpose of this study was to evaluate the effectiveness of the Nd:YAG laser and the Er:YAAG laser on etching enamel for direct bonding of orthodontic bracket. The advantages of laser etching rather than conventional acid etching are to reduce the subsurface demineralization rate, to inhibit the spillage of acid onto uninvolved ""its of enamel, and to save the clinical manipulation time involving drying, trashing and drying again. 189 freshly extracted human premolars were prepared for this research. 165 out of them were divided into 11 groups of 15 teeth. One group was acid etching and the rest groups were irradiated with Nd:YAG laser by four different energy levels(100mj 10pps, 100mj 20pps, 150mj 20pps, 200mj 20pps) and with Er:YAG laser by six different energy levels(60mj 5pps, 60mj 10pps, 100mj 10pps. 200mj 10pps, 200mj l5pps, 400mj 10pps). Shear bond strength was tested with Instron after 24 hours, one week, and three weeks. Twenty-four out of 189 teeth were divided into twelve groups untreated control, acid etching, and ten laser irradiation subgroups. And the ultrastructural enamel surfaces of each group were observed with scanning electron microscope. The results were as follows; 1. The means and the standard deviations of shear bond strength of Nd:YAG and Er:YAU laser irradiation by different energy levels were obtained. 2. Shear bond strengths of Er:YAG laser irradiation groups were higher than those of Nd:YAG laser irradiation groups at the identical energy level. 3. Maximum bond strengths was achieved at the energy of I50mj, 20pps in Nd:YAG laser irradiation groups or 60mj, 10pps in Er:YAG laser irradiation groups. 4. It was acceptible for direct bonding to irradiate lb0mj 20pps with Nd:YAG laser or to irradiate 60mj 10pps with Er:YAG laser considering the results of shear bond strength tests and SEM obsesvation.

  • PDF