• Title/Summary/Keyword: surface pressure deficit

Search Result 17, Processing Time 0.017 seconds

Effects of aspect ratio on laboratory simulation of tornado-like vortices

  • Tang, Zhuo;Zuo, Delong;James, Darryl;Eguch, Yuzuru;Hattori, Yasuo
    • Wind and Structures
    • /
    • v.27 no.2
    • /
    • pp.111-121
    • /
    • 2018
  • Experiments were conducted in a large-scale Ward-type tornado simulator to study tornado-like vortices. Both flow velocities and the pressures at the surface beneath the vortices were measured. An interpretation of these measurements enabled an assessment of the mean flow field as well as the mean and fluctuating characteristics of the surface pressure deficit, which is a manifestation of the flow fluctuation aloft. An emphasis was placed on the effect of the aspect ratio of the tornado simulator on the characteristics of the simulated flow and the corresponding surface pressure deficit, especially the evolution of these characteristics due to the transition of the flow from a single-celled vortex to a two-celled vortex with increasing swirl ratio.

Effects of Air Current Speed on the Microclimates of the Plug Stand under Artificial Light (기류속도가 인공광하에서 공정육묘 개체군의 미기상에 미치는 영향)

  • 김용현;고재풍수
    • Journal of Bio-Environment Control
    • /
    • v.5 no.2
    • /
    • pp.160-166
    • /
    • 1996
  • Objective of this study was to investigate the effects of all current speed on the microclimates above and inside the plug stand under artificial light. Maximum air temperature appeared near the top of the plug stand. Difference in air temperature inside the plug stand increased with the decreasing air current speed. Difference in relative humidity(DRH) to the relative humidity at the Inlet of the main air flow conditioner Inside and above the plug stand decreased with the increasing air current speed. Relative humidity inside the plug stand was 10-15% higher than that above the plug stand. DRH inside a stand of plug at air current speed of 0.3m s$^{-1}$ was about two times as many as that at air current speed of 0.9 m s$^{-1}$ . DRH inside the plug stand was 2.8-6.5% higher at LAI of 2.6 than that at LAI of 0.5. Gradient for the vapour pressure deficit was distinctly appeared at the low air current speed. Direction of vapour pressure flux is from the medium surface upwards. Difference in vapour pressure(DVPD) to the vapour pressure deficit at the inlet of the main air flow conditioner inside and above the plug stand decreased with the increasing height above the medium surface. DVPD inside the plug stand was 0.3-0.4㎪ higher at air current speed of 0.9m s$^{-1}$ than that at air current speed of 0.3m s$^{-1}$ . Results for the effects of air current speed on the relative humidity and vapour pressure deficit indicated that the microclimates above and inside the plug stand at the rear region in plug trays were slightly unfavorable compared to those at middle region.

  • PDF

Drag reduction of a circular cylinder at subcritical flow regime using base shield plates

  • El-Khairy, Nabil A.H.
    • Wind and Structures
    • /
    • v.6 no.5
    • /
    • pp.347-356
    • /
    • 2003
  • Experimental studies on drag reduction of a circular cylinder of diameter D were conducted in the subcritical flow regime at Reynolds numbers in the range $4{\times}10^4{\leq}Re{\leq}10^5$. To shield the cylinder rear surface from the pressure deficit of the unsteady vortex generation in the near wake, two shield plates were attached downstream of the separation points to form a cavity at the base region. The chord of the shield plates, L, ranged from 0.22 to 1.52 D and the cavity width, G, was in the range from 0 to 0.96 D. It is concluded that significant drag reductions from that of a plain cylinder may be achieved by proper sizing of the shield plates and the base cavity. The study shows that using a pair of shield plates at G/D of 0.86 and angular position ${\theta}$ of ${\pm}121^{\circ}$ results in a configuration with percentage drag reduction of 40% for L/D of 0.5, and 55% for L/D of 1.0.

Variation of Vapor Pressure Deficit and Condensation Flux of Air Heating Plastic Greenhouse Installed with Two Layers Thermal Curtain in Winter (이층커튼 온풍난방 플라스틱온실의 겨울철 포차 및 결로량 변화)

  • Lee, Hyun-Woo;Kim, Young-Shik;Sim, Sang-Youn;Lee, Jong-Won
    • Journal of Bio-Environment Control
    • /
    • v.22 no.1
    • /
    • pp.35-41
    • /
    • 2013
  • This study was conducted to provide data necessary for reducing the condensation on greenhouse covering in winter season. The variation of VPD (Vapor Pressure Deficit) and condensation flux was analyzed in experimental tomato greenhouse. VPD values in experimental plastic greenhouse were greater than 0.2 kPa of disease prevention threshold, and lower than 0.5 kPa of threshold for dehumidification. The surface temperature of inside covering was slightly higher than the average temperature of outside and above curtain, and changed according to outside temperature. The humidity above curtain was nearly 100% and good condition for condensation. The humidity below curtain was 75~90% and comparatively stable condition for growing. The condensation flux value in experimental greenhouse corresponded with result of Seginer and Kantz (1986).

Design and Prediction of Three Dimensional Flows in a Low Speed Highly Loaded Axial Flow Fan

  • Liu, Xuejiao;Chen, Liu;Dai, Ren;Yang, Ailing
    • International Journal of Fluid Machinery and Systems
    • /
    • v.6 no.2
    • /
    • pp.94-104
    • /
    • 2013
  • This paper describes the design to increase the blade loading factor of a low speed axial flow fan from normal 0.42 to highly loaded 0.55. A three-dimensional viscous solver is used to model the flows in the highly-loaded and normal loaded stages over its operation range. At the design point operation the static pressure rise can be increased by 20 percent with a deficit of efficiency by 0.3 percent. In the highly loaded fan stage, the rotor hub flow stalls, and separation vortex extends over the rotor hub region. The backflow, which occurs along the stator hub-suction surface, changes the exit flow from the prescribed axial direction. Results in this paper confirm that the limitation of the two dimensional diffusion does not affect primarily on the fan's performance. Highly loaded fan may have actually better performance than its two dimensional design. Three dimensional designing approaches may lead to better highly loaded fan with controlled rotor hub stall.

Effect of cylinder aspect ratio on wake structure behind a finite circular cylinder located in an atmospheric boundary layer (대기경계층 내에 놓인 자유단 원주의 형상비가 후류유동에 미치는 영향에 관한 연구)

  • Park, Cheol-Woo;Lee, Sang-Joon
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.247-252
    • /
    • 2001
  • The flow around free end of a finite circular cylinder(FC) embedded in an atmospheric boundary layer has been investigated experimentally. The experiments were carried out in a closed-return type subsonic wind tunnel with varying aspect ratio of the finite cylinder mounted vertically on a flat plate. The wake structures behind a 2-D cylinder and a finite cylinder located in a uniform flow were also measured for comparison. Reynolds number based on the cylinder diameter was about Re=20,000. A hot-wire anemometer was employed to measure the wake velocity and the mean pressure distributions on the cylinder surface were also measured. The flow past the FC free end shows a complicated three-dimensional wake structure and flow phenomenon is quite different from that of 2-D cylinder. The three-dimensional flow structure was attributed to the downwashing counter rotating vortices separated from the FC free end. As the FC aspect ratio decreases, the vortex shedding frequency is decreased and the vortex formation length is increased compared to that of 2-D cylinder. Due to the descending counter-rotating twin-vortex, in the region near the FC free end, regular vortex shedding from the cylinder is suppressed and the vortex formation region is hardly established. In the wake center region, the mean velocity for the FC located in atmospheric boundary layer has large velocity deficit, compared to that of uniform flow.

  • PDF

Microclimatological Characteristics Observed from the Flux Tower in Gwangneung Forest Watershed (플럭스 타워에서 관측된 광릉 산림 소유역의 미기후학적 특징)

  • Choi Taejin;Lim Jong-Hwan;Chun Jung-Hwa;Lee Dongho;Kim Joon
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.7 no.1
    • /
    • pp.35-44
    • /
    • 2005
  • Microclimate of Gwangneung forest watershed is characterized by analyzing wind, radiation, profiles of air temperature and humidity, soil and bole temperature, precipitation and soil water content measured at and around the flux tower from April 2000 to September 2003. Mountain-valley wind was prevalent due to the topographic effect with dominant wind from east during daytime and relatively weak wind from west during nighttime. Air temperature reaches its peak in July-August whereas monthly-averaged incoming shortwave radiation shows its peak in May due to summer monsoon. Albedo ranges from 0.12 to 0.16 during the growing season. Monthly-averaged bole temperature is in phase with monthly- averaged air temperature which is consistently higher. Monthly-averaged soil temperature lags behind air temperature and becomes higher with leaf fall. With the emergence of leafage in April, maximum temperature level during midday shifts from the ground surface to the crown level of 15-20m in May. Profiles of water vapor pressure show a similar shift in May but the ground surface remains as the major source of water. Vapor pressure deficit is highest in spring and lowest in winter. Monthly averaged surface soil temperatures range from 0 to 20℃ with a maximum in August. Monthly averaged trunk temperatures of the dominant tree species range from -5.8 to 21.6℃ with their seasonal variation and the magnitudes similar to those of air temperature. Annual precipitation amount varies significantly from year to year, of which >60% is from July and August. Vertical profiles of soil moisture show different characteristics that may suggest an important role of lateral movement of soil water associated with rainfall events.

Measurement and Analysis of Free Water Evaporation at HaeNam Paddy Field (해남 농경지에서의 자유 수면 증발 관측과 해석)

  • Han Jin-Su;Lee Bu-Yong
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.7 no.1
    • /
    • pp.91-97
    • /
    • 2005
  • Class A evaporation pan has been used throughout the world to measure free water evaporation mainly by manual observation once a day. In this study, a new automatic water level measurement method is used for understanding of free water evaporation and numerical analysis. This new technique measures the weight of buoyancy bar in water, and does not need calibration because it is not affected by water density change with water temperature. Field observations of evaporation were made near Haenam Meteorological Station over paddy field located in southwestern Korea from 20 April to 30 May 2004 and the data from ten clear days (16 - 25 May) were used for this analysis. The observed total evaporation was about 50.7mm during this period whereas the estimated from an empirical equation was 50.4mm. As expected, the pan evaporation is well correlated with wind speed and the vapor pressure deficit between the water surface and the air.

Effect of Cylinder Aspect Ratio on Wake Structure Behind a Finite Circular Cylinder Located in an Atmospheric Boundary Layer (대기경계층 내에 놓인 자유단 원주의 형상비가 후류유동에 미치는 영향에 관한 연구)

  • Park, Cheol-U;Lee, Sang-Jun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.12
    • /
    • pp.1821-1830
    • /
    • 2001
  • The flow around free end of a finite circular cylinder (FC) embedded in an atmospheric boundary layer has been investigated experimentally. The experiments were carried out in a closed-return type subsonic wind tunnel with varying aspect ratio of the finite cylinder mounted vertically on a flat plate. The wakes behind a 2-D cylinder and a finite cylinder located in a uniform flow were measured for comparison. Reynolds number based on the cylinder diameter was about Re=20,000. A hot-wire anemometer was employed to measure the wake velocity and the mean pressure distributions on the cylinder surface were also measured. The flow past the FC free end shows a complicated three-dimensional wake structure and flow phenomenon is quite different from that of 2-D cylinder. The three-dimensional flow structure was attributed to the downwashing counter rotating vortices separated from the FC free end. As the FC aspect ratio decreases, the vortex shedding frequency decreases and the vortex formation length increases compared to that of 2-D cylinder. Due to the descending counter-rotating twin-vortex, near the FC free end, regular vortex shedding from the cylinder is suppressed and the vortex formation region is hardly distinguished. Around the center of the wake, the mean velocity for the FC located in atmospheric boundary layer has large velocity deficit compared to that of uniform flow.

Effects of Long-term Exposure to Black Carbon Particles on Growth and Gas Exchange Rates of Fagus crenata, Castanopsis sieboldii, Larix kaempferi and Cryptomeria japonica Seedlings

  • Yamaguchi, Masahiro;Otani, Yoko;Takeda, Kenta;Lenggoro, I. Wuled;Ishida, Atsushi;Yazaki, Kenichi;Noguchi, Kyotaro;Sase, Hiroyuki;Murao, Naoto;Nakaba, Satoshi;Yamane, Kenichi;Kuroda, Katsushi;Sano, Yuzou;Funada, Ryo;Izuta, Takeshi
    • Asian Journal of Atmospheric Environment
    • /
    • v.6 no.4
    • /
    • pp.259-267
    • /
    • 2012
  • To clarify the effects of black carbon (BC) particles on growth and gas exchange rates of Asian forest tree species, the seedlings of Fagus crenata, Castanopsis sieboldii, Larix kaempferi and Cryptomeria japonica were exposed to BC particles with sub-micron size for two growing seasons from 1 June 2009 to 11 November 2010. The BC particles deposited after the exposure to BC were observed on the foliar surface of the 4 tree species. At the end of the experiment, the amount of BC accumulated on the foliar surface after the exposure to BC aerosols were 0.13, 0.69, 0.32 and 0.58 mg C $m^{-2}$ total leaf area in F. crenata, C. sieboldii, L. kaempferi and C. japonica seedlings, respectively. In August 2010, the exposure to BC particles did not significantly affect net photosynthetic rate under any light intensity, stomatal diffusive conductance to water vapour ($g_s$), stomatal limitation of photosynthesis, response of $g_s$ to increase in vapour pressure deficit and leaf temperature under light saturated condition in the leaves or needles of the seedlings. These results suggest that the BC particles deposited on the foliar surface did not reduce net photosynthesis by shading, did not increase leaf temperature by absorption of irradiation light, and did not induce plugging of stomata in the leaves or needles of the seedlings. There were no significant effects of BC particles on the increments of plant height and stem base diameter during the experimental period and the whole-plant dry mass at the end of the experiment. These results indicate that the exposure to BC particles with sub-micron size for two growing seasons did not significantly affect the growth and leaf or needle gas exchange rates of F. crenata, C. sieboldii, L. kaempferi and C. japonica seedlings.