• Title/Summary/Keyword: surface ozone concentration

Search Result 129, Processing Time 0.029 seconds

Simple Forecasting of Surface Ozone through a Statistical Approach

  • Ma, Chang-Jin;Kang, Gong-Unn
    • Journal of Environmental Health Sciences
    • /
    • v.44 no.6
    • /
    • pp.539-547
    • /
    • 2018
  • Objectives: Ozone ($O_3$) advisories are issued by provincial/prefectural and city governments in Korea and Japan when oxidant concentrations exceed the criteria of the related country. Advisories issued only after exposure to high $O_3$ concentrations cannot be considered ideal measures. Forecasts of $O_3$ would be more beneficial to citizens' health and daily life than real-time advisories. The present study was undertaken to present a simplified forecasting model that can predict surface $O_3$ concentrations for the afternoon of the day of the forecast. Methods: For the construction of a simple and practical model, a multivariate regression model was applied. The monitored data on gases and climate variables from Japan's air quality networks that were recorded over nearly one year starting from April 2016 were applied as the subject for our model. Results: A well-known inverse correlation between $NO_2$ and $O_3$ was confirmed by the monitored data for Iksan, Korea and Fukuoka, Japan. Typical time fluctuations for $O_3$ and $NO_x$ were also found. Our model suggests that insolation is the most influential factor in determining the concentration of $O_3$. $CH_4$ also plays a major role in our model. It was possible to visually check for the fit of a theoretical distribution to the observed data by examining the probability-probability (P-P) scatter plot. The goodness of fit of the model in this study was also successfully validated through a comparison (r=0.8, p<0.05) of the measured and predicted $O_3$ concentrations. Conclusions: The advantage of our model is that it is capable of immediate forecasting of surface $O_3$ for the afternoon of the day from the routinely measured values of the precursor and meteorological parameters. Although a comparison to other approaches for $O_3$ forecasting was not carried out, the model suggested in this study would be very helpful for the citizens of Korea and Japan, especially during the $O_3$ season from May to June.

Electrical and Structural Properties of ZnO:Pt Films Prepared by Ultrasonic Spray Pyrolysis (초음파분무열분해법으로 제조한 ZnO:Pt막의 전기적 및 구조적 특성)

  • Ma, Tae-Young;Park, Ki-Cheol
    • Journal of Sensor Science and Technology
    • /
    • v.13 no.1
    • /
    • pp.66-71
    • /
    • 2004
  • Pt-doped zinc oxide (ZnO:Pt) films were deposited by ultrasonic spray pyrolysis. Resistivity variation with Pt concentration was measured. The Pt distribution in ZnO:Pt films was studied through Auger Electron Spectroscopy (AES). The ZnO:Pt films were annealed in the ambient of air, water vapor and ozone, respectively. The variation in crystallographic properties and surface morphologies with respect to the annealing condition was observed by X-Ray Diffraction (XRD) and Scanning Electron Microscopy (SEM). The resistivity variation of the films with the annealing condition was measured. Finally, Atomic Force Microscopy (AFM) measurements were carried out to study the effects of the annealing on the roughness of ZnO:Pt films.

A study on non-thermal plasma reactor for generation of negative ions (음이온 발생을 위한 저온 플라즈마 반응기 개발에 관한 연구)

  • Yu, Guang-Xun;Chae, Jae-Ou;Kim, Woo-Hyung;Wei, Wei;Wang, Hui
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2344-2347
    • /
    • 2007
  • To generate negative ion, a small dielectric barrier discharge (DBD) plasma reactor was used in this study and operated by high AC voltage. With increasing of voltage, we can get more negative ions. However unfortunately, if the input voltage is too high, it will also cause formation of ozone which is very harmful to human being health. So the work of finding out the best condition of Voltage and frequency was carried out firstly. After several times of measurement, operating at 20 kHz frequency is the best condition generating high ion concentration without ozone. For the purpose of finding out the best reactor structure, two types of surface dielectric barrier discharge (DBD) reactors were examined to produce negative oxygen ions at the conditions of 20 kHz frequency. The results indicated that the surface DBD reactor with several small tips showed better characteristics for generation of negative oxygen ions at the same condition.

  • PDF

Air Quality Modeling of Ozone Concentration According to the Roughness Length on the Complex Terrain (복잡지형에서의 지표면 거칠기에 따른 오존 농도 수치모의)

  • Choi, Hyun-Jung;Lee, Hwa-Woon;Sung, Kyoung-Hee
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.23 no.4
    • /
    • pp.430-439
    • /
    • 2007
  • The objective of this work is the air quality modeling according to the practical roughness length using the building information as surface boundary conditions. As accurate wind and temperature field are required to produce realistic urban air quality modeling, comparative simulations by various roughness length are discussed. The prognostic meteorological fields and air quality field over complex areas of Seoul, Korea are generated by the PSU/NCAR mesoscale model (MM5) and the Third Generation Community Multi-scale Air Quality Modeling System (Models-3/CMAQ), respectively. The simulated $O_3$ concentration on complex terrain and their interactions with the weak synoptic flow had relatively strong effects by the roughness length. A comparison of the three meteorological fields of respective roughness length reveals substantial localized differences in surface temperature and wind folds. Under these conditions, the ascended mixing height and weakened wind speed at night which induced the stable boundary stronger, and the difference of simulated $O_3$ concentration is $2{\sim}6\;ppb$.

Filler-Elastomer Interactions. 10. Ozone Treatment on Interfacial Adhesion of Carbon Blacks/NBR Compounds (충전재-탄성체 상호작용. 10. 카본블랙/NBR 복합재료의 계면 접착에 미치는 오존처리의 영향)

  • Cho, Ki-Sook;Zaborski, M.;Slusarski, L.;Park, Soo-Jin
    • Elastomers and Composites
    • /
    • v.38 no.2
    • /
    • pp.139-146
    • /
    • 2003
  • In this work, the influence of ozone treatment on surface properties of carbon black is investigated in terms of X-ray photoelectron spectroscopy (XPS) and contact angles. And their mechanical interfacial properties of the carbon black/acrylonitrile butadiene rubber (NBR) compounds are studied by the crosslink density and composite tearing energy ($G_{IIIC}$). As a result, it is found that the increasing of the ozone concentration leads to an increase of the introduction rate of oxygen-containing functional groups onto carbon black surfaces and to an increase of the surface free energy, resulting in improving both crosslink density and tearing energy ($G_{IIIC}$) of the compounds. The results can be explained by the fact that the oxygen-containing functional groups of carbon black surfaces make an increase of the degree of adhesion at interfaces between carbon blacks and rubber matrix.

Toluene Removal Using Surface Discharge Induced Plasma Chemical Process (연면방전 플라즈마를 이용한 톨루엔 처리에 관한 연구)

  • 부문자;봉춘근;김신도
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.13 no.4
    • /
    • pp.297-305
    • /
    • 1997
  • The experimental study by use of SPCP was fulfilled to remove toluene emitted from various industrial processes. First of all, discharge characteristic was experimented as the change of applied voltage and frequency. Then toluene removal characteristic was tested with the analysis of by-products. As a result, optimum electrical discharge condition was from 20.0 kHz to 25.0 kHz of frequency and from 3.5 kV to 4.0 kV of voltage range. The variation of applied voltage had a more important effect on the removal characteristic of toluene than the frequency variation. The toluene removal efficiency was proportioned to ozone concentration and retention time on discharge plate. It was dropped as increase of toluene concentration, but total treated volume of tolene per power consumption was high. The decomposed toluene was transformed to $CO, CO_2$ and particulates, and the rate of transformation to particulates was higher than CO and $CO_2$ at high toluene concentration. Particulates were increased from 0.017 $\mum$ to 0.3 $\mum$ range of size distribution.

  • PDF

The Role of the Surface Oxide Layer on Ru Nanoparticles in Catalytic Activity of CO Oxidation

  • Kim, Sun-Mi;Qadir, Kamran;Jin, Sook-Young;Jung, Kyeong-Min;Reddy, A. Satyanarayana;Joo, Sang-Hoon;Park, Jeong-Young
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.304-304
    • /
    • 2010
  • The study on the catalytic oxidation of carbon monoxide (CO) to carbon dioxide ($CO_2$) using the noble metals has long been the interest subject and the recent progress in nanoscience provides the opportunity to develop new model systems of catalysts in this field. Of the noble metal catalysts, we selected ruthenium (Ru) as metal catalyst due to its unusual catalytic behavior. The size of colloid Ru NPs was controlled by the concentration of Ru precursor and the final reduction temperatures. For catalytic activity of CO oxidation, it was found that the trend is dependent on the size of Ru NPs. In order to explain this trend, the surface oxide layer surrounding the metal core has been suggested as the catalytically active species through several studies. In this poster, we show the influence of surface oxide on Ru NPs on the catalytic activity of CO oxidation using chemical treatments including oxidation, reduction and UV-Ozone surface treatment. The changes occurring to UV-Ozone surface treatment will be characterized with XPS and SEM. The catalytic activity before and after the chemical modification were measured. We discuss the trend of catalytic activity in light of the formation of core-shell type oxide on nanoparticles surfaces.

  • PDF

Comparative Study on Photochemical Reactions of Aromatic Hydrocarbons in Indoor and Outdoor Smog Chambers (실내/외 스모그 챔버에서의 방향족계 탄화수소의 광화학 반응 비교 연구)

  • Dong Jong-In;Ahn Heung-Soon
    • Journal of Environmental Science International
    • /
    • v.14 no.2
    • /
    • pp.231-240
    • /
    • 2005
  • The number of cases exceeding environmental standards of atmospheric ozone in the major cities in Korea has steadily increased during the past decades. In order to understand and analyze the atmospheric reactions in the atmosphere, especially the secondary photochemical reactions, smog chambers studies have been performed very actively by many research groups worldwide. However, these studies have focused on the mechanism of photochemical reactions in high concentration conditions, not at the ambient levels. Therefore, in-depth studies in these conditions are essentially needed to realize exact mechanism in the atmosphere near the earth surface, especially at Korean atmospheric conditions. In this experiment, the mechanism of photochemical smog was examined through a comparative experiment of smog chambers under sun light and black light conditions. The results of our study indicated that concentrations of ozone, aldehyde, and PAN increased as the radiation of light source increases. Photochemical reaction patterns can be considered quite similar for both black light and sun light experiments. Based on our experiments using toluene as a reactant which is present at significant high levels in ambient air relative to other VOCs, it was found that toluene could contribute notably to oxidize NO to $NO_2$, this reaction can eventually generate some other photochemical oxidants such as ozone, aldehyde, and PAN. The results of simulation and experiments generally showed a good agreement quite well except for the case of $O_3$. The restriction of oxidization of NO to $NO_2$ seems to cause this difference, which is mainly from the reaction of peroxy radical itself and other reactants in the real gas.

Nocturnal Inversion Layer observed by Tethersonde and AWS System and its Relation to Air Pollution at Ulsan (Tethersonde와 기상탑 관측 자료를 이용한 울산지역 야간 역전에 따른 대기오염도 변화와의 관계)

  • Lim Yun-Kyu;Kim Yoo-Keun;Oh In-Bo;Song Sang-Keun
    • Journal of Environmental Science International
    • /
    • v.14 no.6
    • /
    • pp.555-563
    • /
    • 2005
  • This study presents the characteristics of nocturnal inversion layer and their effect on the concentration variations of surface air pollutants using tethersonde and automatic weather station (AWS, 2 layer tower) system in Ulsan during 2003, The method for the distinction of inversion intensity was decided based on the sum of nocturnal temperature gradient. As the results, there was a close correlation (correlation coefficient of 0,76) between the maximum inversion height obtained from tethersonde and the sum of nocturnal temperature gradient. The air pollutant concentration was also directly proportional to the inversion intensity. When the inversion intensity was strong in the nighttime, ozone $(O_3)$ concentration was lower, while nitrogen dioxide $(NO_2)$ concentration was higher. The carbon monoxide (CO) concentration was gradually higher according to the nocturnal inversion intensity, whereas sulfur dioxide $(SO_2)$ concentration was relatively constant. In addition, we found that there was no correlation between the inversion intensity and TSP concentration.

Influence of Refrigeration Oil on Evaporation Heat Transfer of R-134a in a Horizontal Micro-Fin Tube (냉동유가 수평 마이크로 핀관내 R-134a의 증발열전달에 미치는 영향)

  • 배상철;강태욱;김정훈;정찬영;김종수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.8 no.1
    • /
    • pp.140-150
    • /
    • 1996
  • CFC-12, which has been used most widely in automobile air conditioners and household refrigerators is scheduled to be phased out soon because of its high ozone depletion potential. Now HFC-134a is suggested as an alternative refrigerant for CFC-12. In this Study, we intended to investigate how PAG oil influence evaporation heat transfer and flow pattern, using R-134a and PAG oil influences evaporation heat transfer and flow pattern, using R-134a and PAG oil in the horizontal miro-fin evaporation tube. Experiments were conducted under the flowing est conditions : mass velocity 86-250kg/$m^2$s, heat flux 5-30 ㎾/$m^2$, oil concentration 0-21 wt.% and saturation temperature 5$^{\circ}C$. Local evaporation heat transfer coefficients were found to be higher at the top, side and bottom of the tube in this order. Average heat transfer coefficients turned out to increase with oil concentration increment up to 3 wt.% oil concentration, whereas heat transfer coefficients gradually decreased over 3 wt.% oil concentration, because of oil-rich liquid film was formed on the heat transfer surface. Flow patterns were rapidly transitioned to annular regimes up to 3 wt.% oil concentration. In case of pure refrigerant, measured heat transfer coefficients in the experiments were similar to those of Kandlikar's correlation.

  • PDF