• Title/Summary/Keyword: surface measurements

Search Result 3,046, Processing Time 0.024 seconds

Misconception on the Yellow Sea Warm Current in Secondary-School Textbooks and Development of Teaching Materials for Ocean Current Data Visualization (중등학교 교과서 황해난류 오개념 분석 및 해류 데이터 시각화 수업자료 개발)

  • Su-Ran Kim;Kyung-Ae Park;Do-Seong Byun;Kwang-Young Jeong;Byoung-Ju Choi
    • Journal of the Korean earth science society
    • /
    • v.44 no.1
    • /
    • pp.13-35
    • /
    • 2023
  • Ocean currents play the most important role in causing and controlling global climate change. The water depth of the Yellow Sea is very shallow compared to the East Sea, and the circulation and currents of seawater are quite complicated owing to the influence of various wind fields, ocean currents, and river discharge with low-salinity seawater. The Yellow Sea Warm Current (YSWC) is one of the most representative currents of the Yellow Sea in winter and is closely related to the weather of the southwest coast of the Korean Peninsula, so it needs to be treated as important in secondary-school textbooks. Based on the 2015 revised national educational curriculum, secondary-school science and earth science textbooks were analyzed for content related to the YSWC. In addition, a questionnaire survey of secondary-school science teachers was conducted to investigate their perceptions of the temporal variability of ocean currents. Most teachers appeared to have the incorrect knowledge that the YSWC moves north all year round to the west coast of the Korean Peninsula and is strong in the summer like a general warm current. The YSWC does not have strong seasonal variability in current strength, unlike the North Korean Cold Current (NKCC), but does not exist all year round and appears only in winter. These errors in teachers' subject knowledge had a background similar to why they had a misconception that the NKCC was strong in winter. Therefore, errors in textbook contents on the YSWC were analyzed and presented. In addition, to develop students' and teachers' data literacy, class materials on the YSWC that can be used in inquiry activities were developed. A graphical user interface (GUI) program that can visualize the sea surface temperature of the Yellow Sea was introduced, and a program displaying the spatial distribution of water temperature and salinity was developed using World Ocean Atlas (WOA) 2018 oceanic in-situ measurements of water temperature and salinity data and ocean numerical model reanalysis field data. This data visualization materials using oceanic data is expected to improve teachers' misunderstandings and serve as an opportunity to cultivate both students and teachers' ocean and data literacy.

Review of applicability of Turbidity-SS relationship in hyperspectral imaging-based turbid water monitoring (초분광영상 기반 탁수 모니터링에서의 탁도-SS 관계식 적용성 검토)

  • Kim, Jongmin;Kim, Gwang Soo;Kwon, Siyoon;Kim, Young Do
    • Journal of Korea Water Resources Association
    • /
    • v.56 no.12
    • /
    • pp.919-928
    • /
    • 2023
  • Rainfall characteristics in Korea are concentrated during the summer flood season. In particular, when a large amount of turbid water flows into the dam due to the increasing trend of concentrated rainfall due to abnormal rainfall and abnormal weather conditions, prolonged turbid water phenomenon occurs due to the overturning phenomenon. Much research is being conducted on turbid water prediction to solve these problems. To predict turbid water, turbid water data from the upstream inflow is required, but spatial and temporal data resolution is currently insufficient. To improve temporal resolution, the development of the Turbidity-SS conversion equation is necessary, and to improve spatial resolution, multi-item water quality measurement instrument (YSI), Laser In-Situ Scattering and Transmissometry (LISST), and hyperspectral sensors are needed. Sensor-based measurement can improve the spatial resolution of turbid water by measuring line and surface unit data. In addition, in the case of LISST-200X, it is possible to collect data on particle size, etc., so it can be used in the Turbidity-SS conversion equation for fraction (Clay: Silt: Sand). In addition, among recent remote sensing methods, the spatial distribution of turbid water can be presented when using UAVs with higher spatial and temporal resolutions than other payloads and hyperspectral sensors with high spectral and radiometric resolutions. Therefore, in this study, the Turbidity-SS conversion equation was calculated according to the fraction through laboratory analysis using LISST-200X and YSI-EXO, and sensor-based field measurements including UAV (Matrice 600) and hyperspectral sensor (microHSI 410 SHARK) were used. Through this, the spatial distribution of turbidity and suspended sediment concentration, and the turbidity calculated using the Turbidity-SS conversion equation based on the measured suspended sediment concentration, was presented. Through this, we attempted to review the applicability of the Turbidity-SS conversion equation and understand the current status of turbid water occurrence.

Diagnostic Reference Levels for Patient Radiation Doses in Pelvis and Lumbar spine Radiography in Korea (우리나라의 골반 및 요추 엑스선검사에서의 환자선량 권고량)

  • Lee, Kwang-Yong;Lee, Byung-Young;Lee, Jung-Eun;Lee, Hyun-Koo;Jung, Seung-Hwan;Kim, Byung-Woo;Kim, Hyeog-Ju;Kim, Dong-Sup
    • Journal of radiological science and technology
    • /
    • v.32 no.4
    • /
    • pp.401-410
    • /
    • 2009
  • Purpose : Pelvis and lumbar spine radiography, among various types of diagnostic radiography, include gonads of the human body and give patients high radiation dose. Nevertheless, diagnostic reference levels for patient radiation dose in pelvis and lumbar spine radiography has not yet been established in Korea. Therefore, the radiation dose that patients receive from pelvis and lumbar radiography is measured and the diagnostic reference level on patient radiation dose for the optimization of radiation protection of patients in pelvis and lumbar spine radiography was established. Methods : The conditions and diagnostic imaging information acquired during the time of the postero-anterior view of the pelvis and the postero-anterior and lateral view of the lumbar spine at 125 medical institutions throughout Korea are collected for analysis and the entrance surface dose received by patients is measured using a glass dosimeter. The diagnostic reference levels for patient radiation dose in pelvis and lumbar spine radiography to be recommended to the medical institutes is arranged by establishing the dose from the patient radiation dose that corresponds to the 3rd quartile values as the appropriate diagnostic reference level for patient radiation dose. Results : According to the results of the assessment of diagnostic imaging information acquired from pelvis and lumbar spine radiography and the measurement of patient entrance surface dose taken at the 125 medical institutes throughout Korea, the tube voltage ranged between 60~97 kVp, with the average use being 75 kVp, and the tube current ranged between 8~123 mAs, with the average use being 30 mAs. In the posteroanterior and lateral views of lumbar spine radiography, the tube voltage of each view ranged between 65~100 kVp (average use: 78 kVp) and 70~109 kVp (average use: 87 kVp), respectively, and the tube current of each view ranged between 10~100 mAs(average use: 35 mAs) and between 8.9~300 mAs(average use: 64 mAs), respectively. The measurements of entrance surface dose that patients receive during the pelvis and lumbar spine radiography show the following results: in the posteroanterior view of pelvis radiography, the minimum value is 0.59 mGy, the maximum value is 12.69 mGy and the average value is 2.88 mGy with the 1st quartile value being 1.91 mGy, the median being 0.59 mGy, and the 3rd quartile value being 3.43 mGy. Also, in the posteroanterior view of lumbar spine radiography, the minimum value is 0.64 mGy, the maximum value is 23.84 mGy, and the average value is 3.68 mGy with the 1st quartile value being 2.41 mGy, the median being 3.40 mGy, and the 3rd quartile value being 4.08 mGy. In the lateral view of lumbar spine radiography, the minimum value is 1.90 mGy, the maximum value is 45.42 mGy, and the average value is 10.08 mGy with the 1st quartile value being 6.03 mGy, the median being 9.09 mGy and the 3rd quartile value being 12.65 mGy. Conclusions : The diagnostic reference levels for patient radiation dose to be recommended to the medical institutes in Korea is 3.42 mGy for the posteroanterior view of pelvis radiography, 4.08 mGy for the posteroanterior view of lumbar spine radiography, and 12.65 mGy for the lateral view of lumbar spine radiography. Such values are all lower than the values recommended by 6 international organizations including World Health Organization, where the recommended values are 10 mGy for the posteroanterior view of pelvis radiography, 10 mGy for the posteroanterior view of lumbar spine radiography and 30 mGy for the lateral view of lumbar spine radiography.

  • PDF

Dosimetric Evaluation of a Small Intraoral X-ray Tube for Dental Imaging (치과용 초소형 X-선 튜브의 선량평가)

  • Ji, Yunseo;Kim, YeonWoo;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.26 no.3
    • /
    • pp.160-167
    • /
    • 2015
  • Radiation exposure from medical diagnostic imaging procedures to patients is one of the most significant interests in diagnostic x-ray system. A miniature x-ray intraoral tube was developed for the first time in the world which can be inserted into the mouth for imaging. Dose evaluation should be carried out in order to utilize such an imaging device for clinical use. In this study, dose evaluation of the new x-ray unit was performed by 1) using a custom made in vivo Pig phantom, 2) determining exposure condition for the clinical use, and 3) measuring patient dose of the new system. On the basis of DRLs (Diagnostic Reference Level) recommended by KDFA (Korea Food & Drug Administration), the ESD (Entrance Skin Dose) and DAP (Dose Area Product) measurements for the new x-ray imaging device were designed and measured. The maximum voltage and current of the x-ray tubes used in this study were 55 kVp, and 300 mA. The active area of the detector was $72{\times}72mm$ with pixel size of $48{\mu}m$. To obtain the operating condition of the new system, pig jaw phantom images showing major tooth-associated tissues, such as clown, pulp cavity were acquired at 1 frame/sec. Changing the beam currents 20 to $80{\mu}A$, x-ray images of 50 frames were obtained for one beam current with optimum x-ray exposure setting. Pig jaw phantom images were acquired from two commercial x-ray imaging units and compared to the new x-ray device: CS 2100, Carestream Dental LLC and EXARO, HIOSSEN, Inc. Their exposure conditions were 60 kV, 7 mA, and 60 kV, 2 mA, respectively. Comparing the new x-ray device and conventional x-ray imaging units, images of the new x-ray device around teeth and their neighboring tissues turn out to be better in spite of its small x-ray field size. ESD of the new x-ray device was measured 1.369 mGy on the beam condition for the best image quality, 0.051 mAs, which is much less than DRLs recommended by IAEA (International Atomic Energy Agency) and KDFA, both. Its dose distribution in the x-ray field size was observed to be uniform with standard deviation of 5~10 %. DAP of the new x-ray device was $82.4mGy*cm^2$ less than DRL established by KDFA even though its x-ray field size was small. This study shows that the new x-ray imaging device offers better in image quality and lower radiation dose compared to the conventional intraoral units. In additions, methods and know-how for studies in x-ray features could be accumulated from this work.

The Evaluation of Radiation Dose to Embryo/Fetus and the Design of Shielding in the Treatment of Brain Tumors (임산부의 전뇌 방사선 치료에 있어서의 태아의 방사선량 측정 및 차폐 구조의 설계)

  • Cho, Woong;Huh, Soon-Nyung;Chie, Eui-Kyu;Ha, Sung-Whan;Park, Yang-Gyun;Park, Jong-Min;Park, Suk-Won
    • Journal of Radiation Protection and Research
    • /
    • v.31 no.4
    • /
    • pp.203-210
    • /
    • 2006
  • Purpose : To estimate the dose to the embryo/fetus of a pregnant patient with brain tumors, and to design an shielding device to keep the embryo/fetus dose under acceptable levels Materials and Methods : A shielding wall with the dimension of 1.55 m height, 0.9 m width, and 30 m thickness is fabricated with 4 trolleys under the wall. It is placed between a Patient and the treatment head of a linear accelerator to attenuate the leakage radiation effectively from the treatment head, and is placed 1 cm below the lower margin of the treatment field in order to minimize the dose to a patient from the treatment head. An anti-patient scattering neck supporters with 2 cm thick Cerrobend metal is designed to minimize the scattered radiation from the treatment fields, and it is divided into 2 section. They are installed around the patient neck by attach from right and left sides. A shielding bridge for anti-room scattered radiation is utilized to place 2 sheets of 3 mm lead plates above the abdomen to setup three detectors under the lead sheets. Humanoid phantom is irradiated with the same treatment parameters, and with and without shielding devices using TLD, and ionization chambers with and without a build-up cap. Results : The dose to the embryo/fetus without shielding was 3.20, 3.21, 1.44, 0.90 cGy at off-field distances of 30, 40, 50, and 60 cm. With shielding, the dose to embryo/fetus was reduced to 0.88, 0.60, 0.35, 0.25 cGy, and the ratio of the shielding effect varied from 70% to 80%. TLD results were 1.8, 1.2, 0.8, 1.2, and 0.8 cGy. The dose measured by the survey meter was 10.9 mR/h at the patient's surface of abdomen. The dose to the embryo/fetus was estimated to be about 1 cGy during the entire treatment. Conclusion : According to the AAPM Report No 50 regarding the dose limit of the embryo/fetus during the pregnancy, the dose to the embryo/fetus with little risk is less than 5 cGy. Our measurements satisfy the recommended values. Our shielding technique was proven to be acceptable.

Soluble IL-2R, IFN-$\gamma$ and Neopterin as Immunologic Markers in Patients with Tuberculosis (결핵 환자에서 면역학적 지표로서의 sIL-2R, IFN-$\gamma$, Neopterin에 관한 연구)

  • Ryu, Yon-Ju;Ryu, Kum-Hei;Kim, Su-Hyun;Lee, Jong-Soo;Cheon, Seon-Hee;Seoh, Ju-Young
    • Tuberculosis and Respiratory Diseases
    • /
    • v.53 no.3
    • /
    • pp.294-308
    • /
    • 2002
  • Background : The cell-mediated immune response plays an important role in tuberculosis. After being activated by mycobacterial antigens, T lymphocytes express a high affinity receptor (IL-2R) for interleukin-2 (IL-2) on their own surface and release a soluble fraction of the IL-2 receptor (sIL-2R) from the cell membrane into the circulation. Neopterin is a metabolite of guanosine-triphosphate, which is produced by stimulated macrophages under the influence of IFN-$\gamma$ with a T lymphocyte origin. Therefore, the utility of sIL-2R, IFN-$\gamma$ and the neopterin levels as immunologic indices of the cell-mediated immune response and severity of disease in patients with pulmonary tuberculosis was assessed. Methods : The serum sIL-2R, IFN-$\gamma$ and neopterin levels were measured in 39 patients with pulmonary tuberculosis, 6 patients with tuberculous lymphadenitis prior to treatment and 10 healthy subjects. The serum and pleural sIL-2R, neopterin and ADA levels were measured in 22 patients with tuberculous pleurisy. The patients with pulmonary tuberculosis were divided into a mild, moderate and severe group according to the severity by ATS guidelines. To compare the results from these patients with those of the pretreatment levels, the sIL-2R, IFN-$\gamma$ and neopterin levels were measured in 36 of the 39 patients(1 patient, expired; 2 patients were referred to a sanitarium) with pulmonary tuberculosis after 2 months of treatment. Results : 1) the serum sIL-2R and IFN-$\gamma$ levels were elevated in patients with tuberculosis when compared to those of healthy subjects (p>0.05). The neopterin concentration in the serum was significantly lower in patients with pulmonary tuberculosis($2967{\pm}2132.8$ pg/ml) than in healthy controls($4949{\pm}1242.1$ pg/ml)(p<0.05). 2) In the pulmonary tuberculosis group, the serum sIL-2R and IFN-$\gamma$ levels were higher in patients with severe disease than those in patients with mild and moderate disease. However, the neopterin levels declined as the pulmonary tuberculosis became more severe (p<0.01). 3) The mean serum sIL-2R and IFN-$\gamma$ levels declined from $1071{\pm}1139.4$ U/ml to $1023{\pm}1920.9$ U/ml(p>0.05), $41{\pm}52.8$ pg/ml to $22{\pm}23.9$ gm/ml(p<0.05), respectively, after 2 month of treatment. The mean serum neopterin levels increased from $3158{\pm}2272.6$ pg/ml to $3737{\pm}2307.5$ pg/ml(p>0.05) after a 2 month of treatment. These findings were remarkable in the severe group of pulmonary tuberculosis with a clinical correlation. 4) In the patients with tuberculous pleurisy, the serum sIL-2R and ADA were significantly higher than those in the pleural fluid, However, the neopterin levels in the sera and pleural effusion were similar. Conclusion : On the basis of this study, sIL-2R, IFN-$\gamma$ and neopterin measurements may not only provide an insight into the present state of the cell-mediated immune response, but also serve as parameters monitoring of the prognosis of the disease, particularly in patients with severe pulmonary tuberculosis. In addition, an assay of the pleural sIL-2R levels might signal a stimulated local immunity including T cell activation in the tuberculous pleural effusion.