• Title/Summary/Keyword: surface hydrophobicity

Search Result 419, Processing Time 0.036 seconds

Kinetics of Denaturation of Human and Chicken Hemoglobins in the Presence of Co-solvents

  • Ajloo, Davood;Moosavi-Movahedi, Ali A.
    • BMB Reports
    • /
    • v.36 no.4
    • /
    • pp.367-372
    • /
    • 2003
  • The stability of four hemoglobins (Hb) in dimer forms (low concentration) were investigated by the kinetics of denaturation. The rate constants of denaturation were obtained by variation of 280 nm absorption versus time in 10 mM Tris-HCl, 10 mM EDTA, pH 8.0 at $45^{\circ}C$ in the absence and presence of 0.5 M ethanol, dimethyl sulfoxide (DMSO), formamide, and glycerol. The results show the trend of rate constants in different co-solvents in the following order: chicken hemolysate < human hemolysate and chicken Hb D < chicken Hb A. The buried surface area was calculated for Hb samples in the absence of cosolvents. Accordingly, the trend points out that: chicken Hb D > chicken Hb A > human Hb A. These results suggest that both chicken hemolysate and chicken Hb D are relatively more stable than human and chicken Hb A, respectively. However, the denaturation rate constants of Hb in different co-solvents have designated the following order: ethanol > DMSO > formamide > glycerol. As a matter of fact, this phenomenon is an indication of an increase in the denaturation capacity (DC) and hydrophobicity, and a decrease in the surface tension of the solution in the preceding co-solvents.

Rapid Fabrication of Micro-nano Structured Thin Film for Water Droplet Separation using 355nm UV Laser Ablation (355 nm UV 레이저 어블레이션을 이용한 마이크로-나노 구조의 액적 분리용 박막 필터 쾌속 제작)

  • Shin, Bo-Sung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.29 no.7
    • /
    • pp.799-804
    • /
    • 2012
  • Recently micro-nano structures has widely been reported to improve the performance of waterproof, heat isolation, sound and light absorption in various fields of electric devices such as mobiles, battery, display and solar panels. A lot of micro-sized holes on the surface of thin film provide excellent sound, or heat, or light transmission efficiency more than solid film and simultaneously nano-sized protrusions around micro hole increase the hydrophobicity of the surface of thin film because of lotus leaf effects as generally known previously. In this paper new rapid fabrication process with 355 nm UV laser ablation was proposed to get micro-nano structures on the surface of thin film, which have only been observed at higher laser fluence. Developed thin micro-nano structured film was also investigated the hydrophobic property by measuring the contact angle and demonstrated the possibility to apply to water droplet separation.

Antibacterial and Antibiofilm Effect of Cell-Free Supernatant of Lactobacillus brevis KCCM 202399 Isolated from Korean Fermented Food against Streptococcus mutans KCTC 5458

  • Kim, Jong Ha;Jang, Hye Ji;Lee, Na-Kyoung;Paik, Hyun-Dong
    • Journal of Microbiology and Biotechnology
    • /
    • v.32 no.1
    • /
    • pp.56-63
    • /
    • 2022
  • This study aims to determine the antibiofilm effect of cell-free supernatant (CFS) of Lactobacillus brevis strains against Streptococcus mutans strains. To study the antibiofilm mechanism against S. mutans strains, antibacterial effects, cell surface properties (auto-aggregation and cell surface hydrophobicity), exopolysaccharide (EPS) production, and morphological changes were examined. The antibiofilm effect of L. brevis KCCM 202399 CFS as morphological changes were evaluated by scanning electron microscopy (SEM) and confocal laser scanning microscopy (CLSM), compared with the control treatment. Among the L. brevis strains, L. brevis KCCM 202399 showed the highest antibiofilm effect on S. mutans KCTC 5458. The antibacterial effect of L. brevis KCCM 202399 against S. mutans KCTC 5458 was investigated using the deferred method (16.00 mm). The minimum inhibitory concentration of L. brevis KCCM 202399 against S. mutans KCTC 5458 was 25.00%. Compared with the control treatment, L. brevis KCCM 202399 CFS inhibited the bacterial adhesion of S. mutans KCTC 5458 by decreasing auto-aggregation, cell surface hydrophobicity, and EPS production (45.91%, 40.51%, and 67.44%, respectively). L. brevis KCCM 202399 CFS inhibited and eradicated the S. mutans KCTC 5458 biofilm. Therefore, these results suggest that L. brevis KCCM 202399 CFS may be used to develop oral health in the probiotic industry.

Hydrophobicity Evaluation of Oblique Micro-asperities Structures (경사 돌기 표면의 젖음 특성 평가)

  • Sung Ik Beak;Tae Wan Kim
    • Tribology and Lubricants
    • /
    • v.39 no.2
    • /
    • pp.56-60
    • /
    • 2023
  • In this study, we evaluate the anisotropic flow of droplets according to the directionality of asperities. We manufacture a mold with an inclined hole by adjusting the jig angle using a high-power diode laser. Using the manufactured mold, we prepare specimens for wettability studies by the micro molding technique. We fabricate twelve kinds of surfaces with micro-asperities inclined at 0°, 15°, 30°, and 45° for asperity pitches of 100 ㎛, 200 ㎛, and 300 ㎛. We evaluate the static and dynamic behaviors of the droplets as a function of the asperities pitch and inclination angles. The anisotropic effect increases as the pitch increases between asperities, and the anisotropic flow characteristics increase as the inclination angle of the asperities increases. On the surface with hole pitches of 100 ㎛ and 200 ㎛, the contact angle of the droplet shows high hydrophobicity at approximately 160°, but on the surface with the 300-㎛ hole pitch, the contact angle is approximately 110°, indicating that the hydrophobic effect rapidly reduces. Additionally, when the inclination angle of the asperities is approximately 30°, the left and right contact angle deviations of the droplet are the lowest, showing that the roll-off angle is relatively low.

Fabrication of Hierarchical Nanostructures Using Vacuum Cluster System

  • Lee, Jun-Young;Yeo, Jong-Souk
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.389-390
    • /
    • 2012
  • In this study, we fabricate a superhydrophobic surface made of hierarchical nanostructures that combine wax crystalline structure with moth-eye structure using vacuum cluster system and measure their hydrophobicity and durability. Since the lotus effect was found, much work has been done on studying self-cleaning surface for decades. The surface of lotus leaf consists of multi-level layers of micro scale papillose epidermal cells and epicuticular wax crystalloids [1]. This hierarchical structure has superhydrophobic property because the sufficiently rough surface allows air pockets to form easily below the liquid, the so-called Cassie state, so that the relatively small area of water/solid interface makes the energetic cost associated with corresponding water/air interfaces smaller than the energy gained [2]. Various nanostructures have been reported for fabricating the self-cleaning surface but in general, they have the problem of low durability. More than two nanostructures on a surface can be integrated together to increase hydrophobicity and durability of the surface as in the lotus leaf [3,5]. As one of the bio-inspired nanostructures, we introduce a hierarchical nanostructure fabricated with a high vacuum cluster system. A hierarchical nanostructure is a combination of moth-eye structure with an average pitch of 300 nm and height of 700 nm, and the wax crystalline structure with an average width and height of 200 nm. The moth-eye structure is fabricated with deep reactive ion etching (DRIE) process. $SiO_2$ layer is initially deposited on a glass substrate using PECVD in the cluster system. Then, Au seed layer is deposited for a few second using DC sputtering process to provide stochastic mask for etching the underlying $SiO_2$ layer with ICP-RIE so that moth-eye structure can be fabricated. Additionally, n-hexatriacontane paraffin wax ($C_{36}H_{74}$) is deposited on the moth-eye structure in a thermal evaporator and self-recrystallized at $40^{\circ}C$ for 4h [4]. All of steps are conducted utilizing vacuum cluster system to minimize the contamination. The water contact angles are measured by tensiometer. The morphology of the surface is characterized using SEM and AFM and the reflectance is measured by spectrophotometer.

  • PDF

Tracking Performance Test of Polymer Insulator with Salt Solution which is added Surface Active Agent (계면활성제가 첨가된 염수용액에 따른 폴리머 애자의 트래킹 성능 평가)

  • Cho, Han-Goo;Lee, Un-Yong;Han, Dong-Hee;Kang, Sung-Hwa;Choi, In-Hyuk;Lim, Kee-Joe
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.18 no.1
    • /
    • pp.62-67
    • /
    • 2005
  • Recently, polymer insulators that are used for high voltage applications have some advantages such as light weight, small size, vandalism resistance, hydrophobicity and easy making process. During outdoor service of polymer insulators, the surface of the insulating material is frequently subjected to moisture and contamination that lead to dry band arcing. Their tracking resistance, erosion resistance, end sealing and shed design are very important because dry band arcing causes degradation of polymer surface. Aging test to estimate life property of polymer insulator is executed through several international standard such as IEC 61109 and CEA tracking wheel test, but is not getting clear conclusion yet. There are two methods in the diagnosis method of polymer insulator such as off-line and on-line. The diagnosis methods in off-line are external condition analysis by the eye, contaminant analysis on surface, surface analysis, pollution withstand voltage test, power frequency flashover voltage test, lightning impulse flashover test, tensile fracture load test and flexural load test. Polymer material is also investigated it's tracking resistance by adding surface active agent in IEC 587. In this paper, the tracking performance of polymer insulator with salt solution which is added surface active agent. The diagnosis of insulator sample has been analyzed by leakage current and visual examination, STRI guide and thermal image camera.

Characterization of Acetylene Plasma-Polymer Films: Recovery of Surface Hydrophobicity by Aging

  • Kim, Jeong-Ho;Kim, Tae-Hyung;Oh, Jung-Geun;Noh, Seok-Hwan;Lee, Jeong-Soo;Park, Kyu-Ho;Ha, Sam-Chul;Kang, Heon
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.11
    • /
    • pp.2589-2594
    • /
    • 2009
  • Aging phenomena of plasma polymer films were studied by using the surface analysis techniques of contact angle measurement, X-ray photoelectron spectroscopy (XPS), time-of-flight secondary ion mass spectrometry (TOFSIMS), and atomic force microscopy (AFM). The polymer films were grown on an aluminum substrate by using a plasma polymerization method from a gas mixture of acetylene and helium, and the films were subsequently modified to have a hydrophilic surface by oxygen plasma treatment. Aging of the polymer films was examined by exposing the samples to water and air environments. The aging process increased the hydrophobicity of the surface, as revealed by an increase in the advancing contact angle of water. XPS analysis showed that the population of oxygen-containing polar groups increased due to the uptake of oxygen during the aging, whereas TOF-SIMS analysis revealed a decrease in the polar group population in the uppermost surface layer. The results suggest that the change in surface property from hydrophilic to hydrophobic nature results from the restructuring of polymer chains near the surface, rather than compositional change of the surface. Oxidative degradation may enhance the mobility and the restructuring process of polymer chains.

Effect of Sub-minimal Inhibitory Concentration of Chlorhexidine on Biofilm Formation and Coaggregation of Early Colonizers, Streptococci and Actinomycetes

  • Lee, So Yeon;Lee, Si Young
    • International Journal of Oral Biology
    • /
    • v.41 no.4
    • /
    • pp.209-215
    • /
    • 2016
  • Chlorhexidine has long been used in mouth washes for the control of dental caries, gingivitis and dental plaque. Minimal inhibitory concentration (MIC) is the lowest concentration of an antimicrobial substance to inhibit the growth of bacteria. Concentrations lower than the MIC are called sub minimal inhibitory concentrations (sub-MICs). Many studies have reported that sub-MICs of antimicrobial substances can affect the virulence of bacteria. The aim of this study was to investigate the effect of sub-MIC chlorhexidine on biofilm formation and coaggregation of oral early colonizers, such as Streptococcus gordonii, Actinomyces naeslundii and Actinomyces odontolyticus. The biofilm formation of S. gordonii, A. naeslundii and A. odontolyticus was not affected by sub-MIC chlorhexidine. However, the biofilm formation of S. mutans increased after incubation with sub-MIC chlorhexidine. In addition, cell surface hydrophobicity of S. mutans treated with sub-MIC of chlorhexidine, decreased when compared with the group not treated with chlorhexidine. However, significant differences were seen with other bacteria. Coaggregation of A. naeslundii with A. odontolyticus reduced by sub-MIC chlorhexidine, whereas the coaggreagation of A. naeslundii with S. gordonii remained unaffected. These results indicate that sub-MIC chlorhexidine could influence the binding properties, such as biofilm formation, hydrophobicity and coaggregation, in early colonizing streptococci and actinomycetes.

Performance Evaluation of Polymer Insulator using Tracking Wheel and Multi-Aging Test (트래킹 휠과 복합열화시험에 의한 폴리머 애자의 성능 평가)

  • 조한구;안명상;한세원;허종철;이운용
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.119-122
    • /
    • 2000
  • Recently polymer insulators are being used for outdoor high voltage applications. Polymer insulators for transmission line have significant advantages over porcelain and glass insulators, especially for ultra-high voltage transmission lines. Their advantages are light weight, vandalism resistance and hydrophobicity. Polymer insulators are a relatively new technology, but their expected life is still unknown. Therefore these estimating technique are very important. Their life time is related to weathering and operating condition. Multi-aging test is requested because aging factor is occurred by multi-aging than unique aging. The aging test about polymer insulators have mainly carried out by IEC 61109. This paper presents multi-stress chamber experiments and tracking wheel test to examine the tracking and erosion performance of polymer insulator for transmission. Multi-stress testing is able to demonstrate deficiencies of polymer insulator materials and designs, including the nature of interfaces in insulation design. We have investigated IEC 61109 Annex C (5000h aging test) and CEA tracking wheel test as test methods of artificial accelerated aging. The aging degree of polymer insulator is estimated by leakage current, measurement of hydrophobicity degree, damage conditions of insulator surface, withstand voltage test etc.

  • PDF

Effects of Extracting Conditions on the Properties of Pish Meal Protein Isolates and the Permeability of Protein Film for Ester Compounds (추출조건이 어분단백질 물성과 필름의 ester 화합물 투과율에 미치는 영향)

  • YOU Byeong-Jin;SHIM Jae-Man
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.34 no.4
    • /
    • pp.320-326
    • /
    • 2001
  • To obtain the basic data for preparing edible or biodegradable film, fish meal protein isolates (FMPI) were prepared through alkaline extraction. And FMPI's properties and the ester compounds permeability of FMPI film were measured. FMPI were extracted under various extracting time with 0.2 N NaOH solution at $60^{\circ}C$, Recovery ratios of FMPI extracted from fish meal were increased with extracting time increasing. Surface hydrophobicity of FMPI extracted for 1 hr showed highest value. Emulsifying activity index (EAI) was increased with the increasement of extracting time but its emulsifying stability index (ESI) showed an inverse results. Viscosity of FMPI solution showed the highest value at pH 2 but showed the lowest value at pH 4, The higher concentration of sorbitol as plasticizer showed the higher ethyl acetate permeability of FMPI film, Ethyl acetate permeability of FMPI films according to kind of plasticizers showed different degree and increased in order as follow: polyethylene glycol, glycerol and sorbitol. Ester compounds having the lower molecular weight showed the higher permeability. Increment of temperature increased the ethyl acetate permeability of FMPI film. FMPI haying higher surface hydrophobicity made FMPI film be higher tensile strength. On elongation of FMPI films, kinds of plasticizer were more effective than surface hydrophobicity of FMPI.

  • PDF