• Title/Summary/Keyword: surface exposure

Search Result 1,374, Processing Time 0.035 seconds

THE EFFECT OF IRRADIATION MODES ON POLYMERIZATION AND MICROLEAKAGE OF COMPOSITE RESIN (광조사 방식이 복합레진의 중합과 누출에 미치는 영향)

  • Park, Jong-Jin;Park, Jeong-Won;Park, Sung-Ho;Park, Ju-Myong;Kwon, Tae-Kyung;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.2
    • /
    • pp.158-174
    • /
    • 2002
  • The aim of this study was to investigate the effect of light irradiation modes on polymerization shrinkage, degree of cure and microleakage of a composite resin. VIP$^{TM}$ (Bisco Dental Products, Schaumburg, IL, USA) and Optilux 501$^{TM}$ (Demetron/Kerr, Danbury, CT, USA) were used for curing Filtek$^{TM}$ Z-250 (3M Dental Products, St. Paul., MN, USA) composite resin using following irradiation modes: VIP$^{TM}$ (Bisco) 200mW/$\textrm{cm}^2$ (V2), 400mW/$\textrm{cm}^2$ (V4), 600mW/$\textrm{cm}^2$ (V6), Pulse-delay (200 mW/$\textrm{cm}^2$ 3 seconds, 5 minutes wait, 600mW/$\textrm{cm}^2$ 30seconds, VPD) and Optilux 501$^{TM}$ (Demetron/Kerr) C-mode (OC), R-mode (OR). Linear polymerization shrinkage of the composite specimens were measured using Linometer (R&B, Daejeon, Korea) for 90 seconds for V2, V4, V6, OC, OR groups and for up to 363 seconds for VPD group (n=10, each). Degree of conversion was measured using FTIR spectrometer (IFS 120 HR, Bruker Karlsruhe, Germany) at the bottom surface of 2 mm thick composite specimens V2, Y4, V6, OC groups were measured separately at five irradiation times (5, 10, 20, 40, 60 seconds) and OR, VPD groups were measured in the above mentioned irradiation modes (n=5 each). Microhardness was measured using Digital microhardness tester (FM7, Future-Tech Co., Tokyo, Japan) at the top and bottom surfaces of 2mm thick composite specimens after exposure to the same irradiation modes as the test of degree of conversion(n=3, each). For the microleakage test, class V cavities were prepared on the distal surface of the ninety extracted human third molars. The cavities were restored with one of the following irradiation modes : V2/60 seconds, V4/40 seconds, V6/30 seconds, VPD , OC and OR. Microleakage was assessed by dye penetration along enamel and dentin margins of cavities. Mean polymerization shrinkage, mean degree of conversion and mean microhardness values for all groups at each time were analyzed using one-way ANOVA and Duncan's multiple range test, and using chi-square test far microleakage values. The results were as follows : . Polymerization shrinkage was increased with higher light intensity in groups using VIP$^{TM}$ (Bisco) : the highest with 600mW/$\textrm{cm}^2$, followed by Pulse-delay, 400mW/$\textrm{cm}^2$ and 200mW/$\textrm{cm}^2$ groups, The degree of polymerization shrinkage was higher with Continuous mode than with Ramp mode in groups using Optilux 501$^{TM}$ (Demetron/Kerr). . Degree of conversion and microhardness values were higher with higher light intensity. The final degree of conversion was in the range of 44.7 to 54.98% and the final microhardness value in the range of 34.10 to 56.30. . Microleakage was greater in dentin margin than in enamel margin. Higher light intensity showed more microleakage in dentin margin in groups using VIP$^{TM}$ (Bisco). The microleakage was the lowest with Continuous mode in enamel margin and with Ramp mode in dentin margin when Optilux 501$^{TM}$ (Demetron/Kerr) was used.

The Effects of Leukocyte Depleted Priming Solution on the Gastric Mucosal $Co_{2}$ Partial Pressure and Serum IL-8 Level during Cardiopulmonary Bypass in Korean Mongrel Dogs (한국산 잡견에서 백혈구 제거 충진액이 체외순환 중 위점막 이산화탄소 농도와 IL-8 수준에 미치는 영향)

  • Park Kuhn;Lee Jong Ho;Kim Jin Ho;Jin Ung;Kwon Jong Bum;Kim Chi Kyeong;Wang Young Pil
    • Journal of Chest Surgery
    • /
    • v.38 no.12 s.257
    • /
    • pp.807-814
    • /
    • 2005
  • Background: Cardiopulmonary bypass is an essential process to maintain circulation for saving life during the cardiac surgery, But it is a process in which systemic inflammation was evoked inevitably because of the exposure of blood to foreign surface. The injuries to distal organs during the cardiopulmonary bypass were resulted from systemic inflammation and the disturbances of micro-circulations in the organs. We designed this study to research the effects of leukocyte depletion from pump-oxygenator priming solution on the systemic inflammation, and the micro-circulation of gastric mucosa that is suggested by the gastric mucosal $CO_{2}$ partial pressure and acidity. Material and Method: The dogs were divided into three groups according to the different pump-oxygenator priming solutions; non-hemic crystalloid solution; leukocyte-depleted homologous blood; and non leukocyte-depleted homo-logous blood. Each priming solution group contained five dogs. In all three groups, 2 hours of cardiopulmonary bypass, and 4 consecutive hours of general anesthesia was maintained on the mechanical ventilation. Each dog was evaluated for the gastric mucosal pH, $CO_{2}$ partial Pressure, arterial pH, $CO_{2}$ partial pressure, the exhaled air $CO_{2}$ partial pressure and the level of IL-8 on before the cardiopulmonary bypass, 1 hour after the cardiopulmonary bypass, 2 hours after the cardiopulmonary bypass, 2 hours after the restoration of normal circulation, and 4 hours after the restoration of normal circulation after the cardiopulmonary bypass. The levels of IL-8 were measured with ELISA (enzyme linked immunosorbent assay) technique. Result: 1. There were significant differences of gastric mucosal $CO_{2}$ partial pressure between the leukocyte-depleted homologous blood group and other two groups(vs non leukocyte-depleted homologous blood group; P=0.02, vs non-hemic crystalloid solution group; P=0,01). 2. The gastric mucosal pH of leukocyte-depleted homologous blood group was significantly different from non leukocyte-depleted homologous blood group (p=0.01). 3. The levels of IL-8, which examine the systemic inflammation, showed signi- ficantly better results in leukocyte-depleted homologous blood group and non-hemic crystalloid solution group than non leukocyte-depleted homologous blood group (p=0.01, 0.01). Conclusion: Based upon these results, we concluded that the leukocyte depletion from the pump-oxygenator priming solution has a beneficial effects in reducing systemic inflammation and the preserving of gastric mucosal micro-circulation.

Study on the Human Influence according to RF Pulse Intensity by use Dental Implant on BRAIN MRI: Using the XFDTD Program (Brain MRI 검사 시 치아 임플란트 시술유무와 RF Pulse 세기에 따른 인체 영향에 관한 연구: XFDTD 프로그램을 이용)

  • Choe, Dea-yeon;Kim, Dong-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.5
    • /
    • pp.361-370
    • /
    • 2017
  • In the Brain MRI, RF Pulse is irradiated on the human body in order to acquire an image. At this time, a considerable part of the irradiated RF Pulse energy is absorbed as it is in our body. This will raise the temperature of the human body, but depending on the extent of exposure, it will affect the human body. The change of the SAR and the temperature of the head according to the change of the magnetic field strength is examined. And to investigate the difference in results depending on the use of dental implant. In the human head model, 64 MHz RF Pulse frequency generated from 1.5 T, 128 MHz RF Pulse frequency generated from 3.0 T, and 298 MHz RF Pulse frequency generated from 7.0 T send a frequency and experiment was performed using dental implant using the XFDTD program, we measured the SAR and body temperature changes around the head. The SAR value showed up to about 5800 times the difference at the RF Pulse frequency of 256 MHz, when with dental implant than without dental implant and as the frequency increased, the use of the dental implant increased difference in the SAR value. The change of the temperature of the head showed a temperature rise nearly 2 to 4 times when with dental implant than without dental implant. As the RF Pulse frequency increase, the SAR value increase, but the change of the temperature of the head decrease. Because of as the frequency increase, wavelength is smaller and the more the amount absorbed by the surface of the human. Physiological and biochemical studies of the human body ar necessary through studies of the presence of dental implant and the cause of reaction caused by change in the RF Pulse frequency.

Suitability Assessment of Domestic Natural Waters as a Culture Medium for Daphnia magna (Daphnia magna의 배양배지로서 국내 자연수의 적절성 평가)

  • Yeom, Dong-Hyuk;Jeon, Chan-Sig
    • Korean Journal of Ecology and Environment
    • /
    • v.45 no.3
    • /
    • pp.271-277
    • /
    • 2012
  • The present study was conducted to assess the suitability of domestic natural waters as a Daphnia magna culture medium. In order to assess survival rate and reproductive output, young female daphnids (parent animals), aged less than 24 hours at the start of the test and produced in the Elendt M4 medium, were exposed to Elendt M4 medium, de-chlorinated tap water, and natural mineral water for 21 days. D. magna cultured in Elendt M4 medium (reference medium) and natural mineral water met the criteria of OECD No. 211, Daphnia magna Reproduction Test Guidelines in terms of percent adult survival, first day of reproduction, and average young production. However, the mortalities of adult daphnids observed in de-chlorinated tap water were more than 20% in two reproduction tests for 21 days. Mortality was observed on exposure days 13, 15, and 18 in de-chlorinated water. The use of D. magna is recommended in water of hardness >80 mg $CaCO_3\;L^{-1}$. However, the hardness of de-chlorinated tap water used in the present study was 50~53 mg $CaCO_3\;L^{-1}$. Therefore, it is judged that the delayed mortalities observed in de-chlorinated tap water were caused by a rapid decreased in hardness when the medium was changed from Elendt M4 to de-chlorinated tap water. When D. magna is cultured using domestic natural waters (underground water, surface water, and de-chlorinated water), the quality-control (QC) data should be maintained through a standardization for health assessment method, toxicity test method using reference chemical, test intervals of reference toxicant toxicity test, and data treatment and interpretation. In the long term, national research programs are needed for the development of test species which are representative of domestic aquatic environmental conditions among indigenous daphnids.

Progress of Composite Fabrication Technologies with the Use of Machinery

  • Choi, Byung-Keun;Kim, Yun-Hae;Ha, Jin-Cheol;Lee, Jin-Woo;Park, Jun-Mu;Park, Soo-Jeong;Moon, Kyung-Man;Chung, Won-Jee;Kim, Man-Soo
    • International Journal of Ocean System Engineering
    • /
    • v.2 no.3
    • /
    • pp.185-194
    • /
    • 2012
  • A Macroscopic combination of two or more distinct materials is commonly referred to as a "Composite Material", having been designed mechanically and chemically superior in function and characteristic than its individual constituent materials. Composite materials are used not only for aerospace and military, but also heavily used in boat/ship building and general composite industries which we are seeing increasingly more. Regardless of the various applications for composite materials, the industry is still limited and requires better fabrication technology and methodology in order to expand and grow. An example of this is that the majority of fabrication facilities nearby still use an antiquated wet lay-up process where fabrication still requires manual hand labor in a 3D environment impeding productivity of composite product design advancement. As an expert in the advanced composites field, I have developed fabrication skills with the use of machinery based on my past composite experience. In autumn 2011, the Korea government confirmed to fund my project. It is the development of a composite sanding machine. I began development of this semi-robotic prototype beginning in 2009. It has possibilities of replacing or augmenting the exhaustive and difficult jobs performed by human hands, such as sanding, grinding, blasting, and polishing in most often, very awkward conditions, and is also will boost productivity, improve surface quality, cut abrasive costs, eliminate vibration injuries, and protect workers from exposure to dust and airborne contamination. Ease of control and operation of the equipment in or outside of the sanding room is a key benefit to end-users. It will prove to be much more economical than normal robotics and minimize errors that commonly occur in factories. The key components and their technologies are a 360 degree rotational shoulder and a wrist that is controlled under PLC controller and joystick manual mode. Development on both of the key modules is complete and are now operational. The Korean government fund boosted my development and I expect to complete full scale development no later than 3rd quarter 2012. Even with the advantages of composite materials, there is still the need to repair or to maintain composite products with a higher level of technology. I have learned many composite repair skills on composite airframe since many composite fabrication skills including repair, requires training for non aerospace applications. The wind energy market is now requiring much larger blades in order to generate more electrical energy for wind farms. One single blade is commonly 50 meters or longer now. When a wind blade becomes damaged from external forces, on-site repair is required on the columns even under strong wind and freezing temperature conditions. In order to correctly obtain polymerization, the repair must be performed on the damaged area within a very limited time. The use of pre-impregnated glass fabric and heating silicone pad and a hot bonder acting precise heating control are surely required.

The usefulness of skin test in evaluation of immunity to varicella (수두에 대한 면역력 평가에 있어서 피부 시험의 유용성)

  • Kim, Ji-Young;Lee, Hye Jeen;Kim, Me Jin;Kim, Young Ho;Jung, Ji A;Yang, Seung;Hwang, Il Tae;Lee, Hae Ran
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.4
    • /
    • pp.377-382
    • /
    • 2008
  • Purpose : The aim of this study is to assess the usefulness of skin test by an inactivated, 1/50 diluted solution of attenuated varicella vaccine in evaluating the immune status to varicella. Methods : Total 41 subjects (22 males, 19 females, aged 1-32 years) were enrolled from July to August, 2005. Past medical history including varicella infection, varicella vaccination were investigated through questionnaires. The skin test solution was prepared from solution of attenuated varicella vaccine(Oka strain) which was inactivated by exposure to room temperature for 10 days and diluted at 1/50 with normal saline. Skin test was done by injecting 0.1 mL of the solution intradermally into the volar surface of the right forearm and sterile normal saline was used as a control on the left forearm. Positive reaction was defined when the transverse diameter of the induration was 5 mm or more. Serum varicella zoster virus specific IgG antibody test by ELISA (enzyme-linked immunosorbent assay) was done. Results : In adults, the sensitivity of the varicella zoster virus skin test compared to ELISA was 94.7% and the positive predictive value was 100%. In children, both the positive predictive value and specificity were 100% but the sensitivity and the negative predictive value were 50% and 30.7% respectively. Children showed smaller skin test reactivity compared to adults. Conclusion : The varicella zoster virus skin test using inactivated, 1/50 diluted solution of attenuated varicella vaccine was proved as one of the useful tools for evaluating the immunity and susceptibility of the varicella zoster virus.

Seasonality of the Biological Activity Factors of the hard clam Meretrix lusoria in the Western Coast of Korea (한국 서해안 백합 Meretrix lusoria의 생물학적 활성요인의 계절성)

  • Song, Jae-Hee;Kim, Chi-Hong;Park, Sung-Woo;Yu, Jin-Ha;Jo, Yeong-Jo
    • Journal of Aquaculture
    • /
    • v.21 no.2
    • /
    • pp.111-122
    • /
    • 2008
  • This study was conducted to assess the usefulness of the temperature characteristics of the tidal flat sediments during low tide as a environmental factor, and burrowing behaviour, fatness, total hemocyte counts(THCs) and differential hemocyte counts(DHCs) of hard clam Meretrix lusoria as biological activity indices for the management of hard clam farms located in Taean(Chungnam province) and Gimje(Jeonbuk province) tidal flat in Korea. Temperature ranges of the sediment at 1cm depth during spring(March to May) and summer(June to August) in Taean(where the exposure time was about $5.5{\sim}6$ hours during low tide) were $8.7{\sim}26.8^{\circ}C\;and\;27.6{\sim}32.8^{\circ}C$, respectively. Even though there was no significant difference(P>0.05), temperatures of the surface sediment where submerged with remained seawater were generally higher than that of uncovered with seawater. Burrowing depths of normally digged hard clams were 0.9{\sim}3.6cm from March to October, 2002. In the field experiment performed at Taean farming ground covered with seawater, burrowing times of the clams under natural water temperatures were $41.6{\pm}10minutes$ in February and $5.4{\pm}1.3minutes$ in August, respectively, and these were influenced by water temperatures. Fatness of hard clams began to decrease from May(at Taean tidal flat) and June(at Gimje tidal flat), showed the lowest level in August and increased again from September. Total hemocytes counts in the hemolymph of the hard clams were decreased to the lowest level in July($24.7{\times}10^4cells/mL$, at Taean tidal flat) and August($28.2{\times}10^4cells/mL$, at Gimje tidal flat), and significantly increased again from September(at Taean tidal flat, P<0.01) and October(at Gimje tidal flat, P<0.001), respectively. We observed three types of hemocytes from the hemolymph of hard clams according to whether hemocytes retain the granules or not and the size of the granules. As a results, we could found that periodical monitoring of the sediment temperatures, clam burrowing behaviour and hemocyte parameters were very helpful for the management of hard clam farming.

The Accuracy of the Digital Imaging System and the Frequency Dependent Type Apex Locator in Root Canal Length Measurement (근관장 측정에 있어서 디지털 영상 처리기와 주파수 의존형 측정기의 정확도)

  • Lee Byaung-Rib;Park Chang-Seo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.28 no.2
    • /
    • pp.435-459
    • /
    • 1998
  • In order to achieve a successful endodontic treatment, root canals must be obturated three-dimensionally without causing any damage to apical tissues. Accurate length determination of the root canal is critical in this case. For this reason, I've used the conventional periapical radiography, Digora/sup (R)/(digital imaging system) and Root ZX/sup (R)/(the frequency dependent type apex locator) to measure the length of the canal and compare it with the true length obtained by cutting the tooth in half and measuring the length between the occlusal surface and the apical foramen. From the information obtained by these measurements, I was able to evaluate the accuracy and clinical usefulness of each systems. whether the thickness of files used in endodontic therapy has any effect on the measuring systems was also evaluated in an effort to simplify the treatment planning phase of endodontic treatment. 29 canals of 29 sound premolars were measured with #15, #20, #25 files by 3 different dentists each using the periapical radiography. Digora/sup (R)/ and Root ZX/sup (R)/. The measurements were then compared with the true length. The results were as follows: 1. In comparing mean discrepancies between measurements obtained by using periapical radiography(mean error: -0.449±0.444 mm), Digora/sup (R)/(mean error: -0.417±0.415 mm) and Root ZX/sup (R)/(mean error: 0.123±0.458 mm) with true length. periapical radiography and Digora/sup (R)/ system had statistically significant differences(p<0.05) in most cases while Root ZX/sup (R)/ showed none(p>0.05). 2. By subtracting values obtained by using periapical radiography, Digora/sup (R)/ and Root ZX/sup (R)/ from the true length and making a distribution table of their absolute values. the following analysis was possible. In the case of periapical film. 140 out of 261<53.6%) were clinically acceptable satisfying the margin of error of less than 0.5 mm. 151 out of 261 (53,6%) were acceptable in the Digora/sup (R)/ system while Root ZX/sup (R)/ had 197 out of 261(75.5%) within the limits of 0.5mm margin of error. 3. In determining whether the thickness of files has any effect on measuring methoths, no statistically significant differences were found(p>0.05). 4. In comparing data obtained from these methods in order to evaluate the difference among measuring methods, there was no statistically significant difference between periapical radiography and Digora/sup (R)/ system(p>0.05), but there was statistically significant difference between Root ZX/sup (R)/ and periapical radiography(p<0.05). Also there was statistically significant difference between Root ZX/sup (R)/ and Digora/sup (R)/ system(p<0.05). In conclusion, Root ZX/sup (R)/ was more accurate when compared with the Digora/sup (R)/ system and periapical radiography and seems to be more effective clinically in determining root canal length. But Root ZX/sup (R)/ has its limits in determining root morphology and number of roots and its accuracy becomes questionable when apical foramen is open due to unknown reasons. Therefore the combined use of Root ZX/sup (R)/ and the periapical radiography are mandatory. Digora/sup (R)/ system seems to be more effective when periapical radiographs are needed in a short period of time because of its short processing time and less exposure.

  • PDF

A marine deep-towed DC resistivity survey in a methane hydrate area, Japan Sea (동해의 메탄 하이드레이트 매장 지역에서의 해양 심부 견인 전기비저항 탐사)

  • Goto, Tada-Nori;Kasaya, Takafumi;Machiyama, Hideaki;Takagi, Ryo;Matsumoto, Ryo;Okuda, Yoshihisa;Satoh, Mikio;Watanabe, Toshiki;Seama, Nobukazu;Mikada, Hitoshi;Sanada, Yoshinori;Kinoshita, Masataka
    • Geophysics and Geophysical Exploration
    • /
    • v.11 no.1
    • /
    • pp.52-59
    • /
    • 2008
  • We have developed a new deep-towed marine DC resistivity survey system. It was designed to detect the top boundary of the methane hydrate zone, which is not imaged well by seismic reflection surveys. Our system, with a transmitter and a 160-m-long tail with eight source electrodes and a receiver dipole, is towed from a research vessel near the seafloor. Numerical calculations show that our marine DC resistivity survey system can effectively image the top surface of the methane hydrate layer. A survey was carried out off Joetsu, in the Japan Sea, where outcrops of methane hydrate are observed. We successfully obtained DC resistivity data along a profile ${\sim}3.5\;km$ long, and detected relatively high apparent resistivity values. Particularly in areas with methane hydrate exposure, anomalously high apparent resistivity was observed, and we interpret these high apparent resistivities to be due to the methane hydrate zone below the seafloor. Marine DC resistivity surveys will be a new tool to image sub-seafloor structures within methane hydrate zones.

Growth and Physiological Characteristics of Five Common Foliage Plant Species Grown under the Influence of Static Magnetic Field (정자기장 처리에 따른 실내 관엽식물의 생육 및 생리적 특성 변화)

  • Lee, Seong Han;Woo, Su Young;Kwak, Myung Ja
    • Horticultural Science & Technology
    • /
    • v.30 no.5
    • /
    • pp.484-492
    • /
    • 2012
  • The present study aimed to investigate the effect of static magnetic field (SMF) on the growth and physiological characteristics of common indoor plant species. Five foliage plant species, Spathiphyllum spp., Ardisia pusilla DC., Syngonium podophyllum, Peperomia pereskiifolia, and Pilea cadierei were potted into plastic pot equipped with round type anisotropic sintered NdFeB permanent magnet inside the pot. The surface magnetic flux density of each magnet was 3,500 G. After 6 months of growth period, the biomass accumulations of Spathiphyllum, A. pusilla, and P. cadierei under SMF were statistically higher than those of controls. Tissue water content also increased under the influence of SMF in most species. The photosynthetic rate of Spathiphyllum under SMF significantly increased but other species showed no significant difference compared with control. Although there was no significant increase in the photosynthetic rates of A. pusilla, and P. cadierei, they showed remarkable increase in total fresh weight under SMF. This suggests that the demand of assimilates for normal metabolism could be decreased under magnetic influence and thereby biomass accumulation could be more favored. But this is not always true for all plant species because P. pereskiifolia in this experiment, showed no changes in both photosynthetic rate and biomass accumulation. Leaf nitrogen and chlorophyll contents were enhanced significantly in most plant species under influence of SMF. Chlorophyll a/b ratio also increased by SMF. Although there might be a limitation depending on plant species, these results suggest that long-term exposure to SMF might allow plant to have an enhanced acclimation capacity against environmental fluctuations and optimal application of SMF could increase the practical use of indoor plants such as an attempt to improve indoor air quality.