• Title/Summary/Keyword: surface electromyography

Search Result 494, Processing Time 0.028 seconds

A Review of Studies Comparing of Surface Electromyography Values between the Low-back Pain Group and Healthy Controls (요통환자군과 정상대조군 사이의 표면근전도값 비교에 관한 연구문헌 고찰)

  • Yoo, Duk-Joo;Cho, Jae-Heung;Chung, Seok-Hee
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.23 no.4
    • /
    • pp.83-93
    • /
    • 2013
  • Objectives To present reviews of studies comparing surface-electromyography (SEMG) values between low back pain group and control group. Methods We searched 8 databases including KoreaMed, Google, KISS (Korean studies Information Service System), RISS (Research Information Sharing Service), OASIS (Oriental medicine Advanced Searching Integrated System), Pubmed, Ovid-MEDLINE and EMBASE. After searching, we conducted study selection by using inclusion and exclusion criteria and quality-assessment. We reviewed the selected studies concerning about the subject's measuring position, findings, sensitivities and specificities. Results 27 Studies were searched and reviewed. In static surface electromyography, more muscle activities observed in low back pain subjects than in controls. In dynamic surface electromyography, the low back pain subjects showed more muscle activites during flexion, while the control group showed more muscle activities during extension. Faster muscle fatigue observed in isometric muscle analysis. Conclusions Surface electromyography values will be able to be objective marker for evaluating low back pain. Further research is needed to determine additional unified protocol such as the type of SEMG and its directions.

Evaluation of Treatment Outcomes in Oromandibular Dystonia Using Surface Electromyography: A Case Series

  • Im, Yeong-Gwan;Kim, Jae-Hyung;Kim, Byung-Gook
    • Journal of Oral Medicine and Pain
    • /
    • v.46 no.4
    • /
    • pp.143-149
    • /
    • 2021
  • Purpose: Oromandibular dystonia is a neurological disorder that affects the jaw and lower face muscles, often resulting in abnormal repetitive movement of the jaw and perioral structures. The purpose of this study was to assess the effectiveness of surface electromyography (EMG) in evaluating the treatment outcome of oromandibular dystonia. Methods: Based on a retrospective review of medical records, we analyzed the data of four patients who received medication or botulinum toxin injection, as well as surface EMG of the jaw muscles before and after treatment. We assessed the patients' clinical characteristics and the results of surface EMG before and after treatment. Results: The case series included one female and three males, and the age range was 65-78 years. Based on the clinical features, two subjects were classified as jaw deviation and the remaining two were as jaw closing. Dystonic patterns revealed by surface EMG varied, including phasic, tonic, and mixed contraction patterns. EMG amplitude after treatment was lower than pre-treatment value in all four subjects, suggesting improved clinical signs and symptoms. One subject who received clonazepam and another who received botulinum toxin injection showed a remarkable reduction in EMG amplitude within a normal range. Conclusions: Surface EMG can be used to effective evaluate treatment outcomes in patients with oromandibular dystonia. It could be considered as an adjunctive diagnostic tool in managing patients with dystonia.

Quantitative Analysis of Myofascial Pain Syndrome in Trapezius Muscle Using Pressure Algometer and Surface Electromyography

  • Kim, Shin-Hye;Ko, Yu-Min;Park, Ji-Won;Youn, Jong-In
    • The Journal of Korean Physical Therapy
    • /
    • v.33 no.5
    • /
    • pp.258-263
    • /
    • 2021
  • Purpose: Myofascial syndrome is a chronic muscle pain caused by repetitive motions with stress-related muscle tension. This study aimed to investigate the validity and reliability of the evidence for diagnosing myofascial pain syndrome in trapezius muscle using a pressure algometer and surface electromyography. Methods: The experiments were performed using a total of 10 subjects, and the target locations were determined by means of a pressure algometer in the right upper trapezius muscle. The part with the lowest pain value as the trigger point and the part with the highest pain value as the non-pain trigger point were selected for measuring the locations. The median frequency and average frequency were measured in those locations with electromyography. To check the muscle fatigue, the upper trapezius muscle was moved up and down for 2 seconds at 5-second intervals in 30 seconds. The measured values were evaluated using the independent paired t-test and MannWhitney U-test. Results: The median frequency at the non-trigger point (13.7) was significantly higher than that at the trigger point (7.3). Furthermore, the mean frequency (14.7) at the non-trigger point was significantly higher than that at the trigger point (6.3). Conclusion: The results showed the correlations between the trigger points of the muscle pain and frequency analysis of surface electromyography. Thus, this study may be possible to use as a diagnostic tool for myofascial pain syndrome.

Estimation of Shoulder Flexion Torque and Angle from Surface Electromyography for Physical Human-Machine Interaction (물리적 인간-기계 상호작용을 위한 표면 근전도 신호 기반의 어깨 굴곡 토크 및 각도 추정)

  • Park, Ki-Han;Lee, Dong-Ju;Kim, Jung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.6
    • /
    • pp.663-669
    • /
    • 2011
  • This paper examines methods to estimate torque and angle in shoulder flexion from surface electromyography(sEMG) signals for intuitive and delicate control of robotic assistance device. Five muscles on the upper arm, three for shoulder flexion and two for shoulder extension, were used to offer favorable sEMG recording conditions in the estimation. The methods tested were the mean absolute value (MAV) with linear regression and the artificial neural network (ANN) method. An optimal condition was sought by varying combination of muscles used and the parameters in each method. The estimation performance was evaluated using the correlation values and normalized root mean square error values. In addition, we discussed their possible use as an estimation of motion intent of a user or as a command input in a physical human-machine interaction system.

Comparative Review on Oriental Medicine Study Utilized Surface Electromyography in Korea, China, Japan (표면근전도를 이용한 한국.중국.일본의 한의학연구 경향)

  • Lee, Hyung Geol;Im, Jeong Gyun;Jung, Da Jung;Kim, Jong Uk;Kim, Lak Hyung;Yook, Tae Han
    • Journal of Acupuncture Research
    • /
    • v.30 no.1
    • /
    • pp.23-34
    • /
    • 2013
  • Background or Objectives : The purpose of this study is to review oriental medicine journal that have been utilize Surface EMG in Korea, China, Japan and compare each country's trend in studies. Methods : We investigated studies in relation to surface EMG through 10 articles in Korea from OASIS, 74 articles in China from CAJ, 6 articles in Japan from J-stage. Results : Of 90 articles, 6 articles in Korea, 7 article in China, 6 articles in Japan, totally 19 articles selected. There was no big differences number of articles, type of articles among three countries. There was differences topic of articles, treatment method of articles among three countries. Conclusion : The result of this study could provide useful information of field of Surface EMG is used in Oriental medicine. Studies about Surface EMG performed in different way in Korea, China, Japan.

Laryngeal Evoked Electromyography with a Noninvasive Technique (비침습적 방법에 의한 후두유발근전도 검사)

  • 정성민;조선희;박기덕
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.10 no.1
    • /
    • pp.30-36
    • /
    • 1999
  • Background and Objectives : Laryngeal Evoked Electromyography(EEMG) is a objective, quantitative technique to determine innervation status of larynx. The possible applications of this technique are to confirm the etiology of impaired vocal fold motion and monitor perioperative vagus nerve trauma. The purpose of this study is to develop a novel method for determining the amount of reinnervation of recurrent laryngeal nerve with accurate, inexpensive, and minimally invasive technique in human. Materials and Methods : Laryngeal EEMG was performed for 16 adults with intact vocal folds motion and 2 patients diagnosed as unilateral vocal fold paralysis. for the purpose of searching what is the optimal and noninvasive technique for laryngeal EEMG, we used 2 types of stimulation configurations(transcutaneous vs percutaneous) and 2 types of recording configurations(intramuscular vs. surface). Results and Conclusions : Percutaneous needle stimulation and surface recording of laryngeal EEMG was reliable and comparable to standard needle stimulation and invasive intramuscular needle recording. But the laryngeal EEMG by the surface recording and transcutaneous surface stimulation was not reliable and repeatable. Therefore we recommended that laryngeal EEMG by surface recording and percutaneous needle stimulation would be minimally invasive, reliable technique to know the status of reinnervation in e patients with vocal fold paralysis.

  • PDF

Human-Machine Interaction based on a Real-time Upper Limb Motion Prediction using Surface Electromyography (표면 근전도 신호를 이용한 실시간 상지부 동작 예측을 통한 인간-기계 상호작용)

  • Kwon, Sun-Cheol;Kim, Jung
    • 한국HCI학회:학술대회논문집
    • /
    • 2009.02a
    • /
    • pp.418-421
    • /
    • 2009
  • This paper presents a human-machine interaction based on a realtime upper limb motion prediction method using surface electromyography (sEMG). The motions were predicted using an artificial neural network algorithm and sEMG signals which are acquired from five muscles, and then a manipulator was controlled to follow after the predicted motions. Upper limb motions were restricted to 2D vertical plane with the contact condition between a user and an end-effector of manipulator. In order to demonstrate the feasibility of the proposed method, experiments using developed method and using a goniometer were performed. The results showed that the proposed real-time motion prediction method can be implemented a human-machine interaction system.

  • PDF

Changes of Surface Temperature and Electromyography Activities by Local Heat and Cold (온열과 냉의 국소적용에 의한 체표면 온도와 근전도 활동의 변화)

  • Choi, Seok-Ju;Lim, Sang-Wan;Kim, Su-Hyon;Mun, Dal-Ju
    • Journal of the Korean Academy of Clinical Electrophysiology
    • /
    • v.5 no.2
    • /
    • pp.61-72
    • /
    • 2007
  • INTRODUCTION: Local heat and cold application has been frequently used as means of muscle relaxation and blood circulation or reinforcing muscle strength, relaxing muscle tension in clinical situation. In particular, it has been known that long-term heat and cold application for relaxing muscle tension inhibits muscle spasticity or tension. But, it has been rarely reported that what influences of heat and cold application on activation of muscle action potential. Therefore, this study aims to analyze surface temperature and electromyography activities according to the heat and cold application. METHODE: Subjects of this research were 10 normal men and women (5 men, 5 women). Hot pack and cold pack was applied to vastus medialis muscle of thigh and rectus femoris muscle for 20 min. Surface temperature of vastus medialis muscle and rectus femoris muscle was measured, knee joint of subjects was in $45^{\circ}$ flexion, sitting on a chair, maximal isometric contraction was induced, surface electromyography (sEMG) signals were collected and root mean square (RMS) and median frequency (MOF) were analyzed. All measurements were conducted before and immediately after experiment, 10 min., 20 min. and 30 min. after experiment. Data were analyzed with SPSS 12.0 program, comparison of changes in superficial temperature and sEMG signals through repeated measurement was conducted with repeated measures ANOVA and significance level $\alpha$ was 0.05. RESULTS: Changes of surface temperature of vastus medialis muscle according to cold application were radically decreased immediately after application, but it was recovered after 30 min. of application and it showed significant difference (F4. 36=72.216, P<0.001). Surface temperature of rectus femoris also showed radical decrease immediately after application, but it was recovered after 30 min. of application and showed significant difference (F4. 36=88.930, P<0.001). Changes of surface temperature of vastus medialis muscle according to heat application were radically increased immediately after application, but it was recovered after 30 min. of application and it showed significant difference (F4. 36=27.267, P<0.001). Surface temperature of rectus femoris also showed radical decrease immediately after application, but it was recovered after 30 min. of application and showed significant difference (F4. 36=19.774, P<0.001). Changes of sEMG by heat and cold application were no statistical difference. Surface temperature of skeletal muscle after heat and cold application showed significant change for 30 min., but it was found that increase or decrease of surface temperature had not great influence on sEMG activities.

  • PDF