• 제목/요약/키워드: surface anatomy

검색결과 254건 처리시간 0.026초

Effects of silanation time on shear bond strength between a gold alloy surface and metal bracket

  • Jung, Min-Ho;Shon, Won-Jun;Park, Young-Seok;Chung, Shin-Hye
    • 대한치과교정학회지
    • /
    • 제43권3호
    • /
    • pp.127-133
    • /
    • 2013
  • Objective: We aimed to investigate the effects of silanation time on the shear bond strength (SBS) of metal brackets on gold alloy in a silicoating procedure and compare the SBS of metal brackets on gold alloy and enamel. Methods: Type III gold alloy plates were sandblasted with 30-${\mu}m$ silicon dioxide. Excess particles were removed with gentle air after silica coating, and silane was applied. Maxillary central-incisor metal brackets were bonded to each conditioned alloy surface with a light curing resin adhesive for 1 s, 30 s, 60 s, or 120 s after applying silane. The brackets were also bonded to 36 upper central incisors with the same adhesive. All samples were cured for 40 s with a light emitting diode curing light. The SBS was tested after 1 h and after 24 h. The adhesive remnant index (ARI) of the samples was also compared. Results: The 60-s and 120-s silanation time groups showed a higher SBS than the other groups (p < 0.05). Samples tested after 24 h showed a significantly higher SBS than did the samples tested after 1 h (p < 0.05). The 1-s group showed higher ARI scores. The one-way analysis of variance and Student-Newman-Keuls test showed that the SBS values of the 60-s and 120-s silanation time groups were not significantly different from the SBS values of enamel. Conclusions: Adequate silanation time is required to produce sufficient bond strength during silicoating.

낙우송(落羽松)(Taxodium distichum Rich.) 지재(枝材)의 압축이상재(壓縮理想材) 및 대응재(對應材)에 관한 해부학적(解剖學的) 특성(特性) (Cellular Anatomy of Compression Wood and Opposite Wood in a Branch of Taxodium distichum Rich.)

  • 이필우;정연집;권미
    • 한국산림과학회지
    • /
    • 제80권3호
    • /
    • pp.296-302
    • /
    • 1991
  • 본 연구(硏究)는 압축이상재가 현저하게 발달되어 있는 낙우송(落羽松)(Taxodium distichum Rich.)의 기재(技材)로부터 압축이상재율과 편심율 변이에 따른 압축이상재와 대응재의 해부학적(解剖學的) 특성(特性)을 비교(比較)하고자 실시하였다. 압축이상재의 조직학적(組織學的) 특성(特性)은 가도관의 둥근형태, 춘재로부터 추재로의 매우 점진적인 가도관 이행(移行), 가도관 선단부의 뒤얽힘 및 나선강(螺旋腔)과 세포간극의 존재 등에 있어 대응재와 다른 특성(特性)을 나타내었으며, 이러한 조직학적(組織學的) 특성(特性)은 압축이상재율과 편싱심률에 관계없이 유지하는 경향을 보였다. 수량적(數量的) 특성에 있어서도 압축이상재는 가도관장(假導管長)이 대응재보다 짧은 특성을 보였으나 방사조직(放射組織) 밀도(密度)와 단열방사조직(單列放射組織)의 수(數)는 압축이상재가 대응재보다 많았다. 그리고 단열방사조직의 세포고(細胞高)는 대응재가 압축이 상재보다 더 큰 특성(特性)을 나타내었다.

  • PDF

Micro-computed tomographic assessment of the shaping ability of the One Curve, One Shape, and ProTaper Next nickel-titanium rotary systems

  • Tufenkci, Pelin;Orhan, Kaan;Celikten, Berkan;Bilecenoglu, Burak;Gur, Gurkan;Sevimay, Semra
    • Restorative Dentistry and Endodontics
    • /
    • 제45권3호
    • /
    • pp.30.1-30.11
    • /
    • 2020
  • Objectives: This micro-computed tomographic (CT) study aimed to compare the shaping abilities of ProTaper Next (PTN), One Shape (OS), and One Curve (OC) files in 3-dimensionally (3D)-printed mandibular molars. Materials and Methods: In order to ensure standardization, 3D-printed mandibular molars with a consistent mesiobuccal canal curvature (45°) were used in the present study (n = 18). Specimens were instrumented with the OC, OS, or PTN files. The teeth were scanned pre- and post-instrumentation using micro-CT to detect changes of the canal volume and surface area, as well as to quantify transportation of the canals after instrumentation. Two-way analysis of variance was used for statistical comparisons. Results: No statistically significant differences were found between the OC and OS groups in the changes of the canal volume and surface area before and after instrumentation (p > 0.05). The OC files showed significantly less transportation than the OS or PTN systems for the apical section (p < 0.05). In a comparison of the systems, similar values were found at the coronal and middle levels, without any significant differences (p > 0.05). Conclusions: These 3 instrumentation systems showed similar shaping abilities, although the OC file achieved a lesser extent of transportation in the apical zone than the OS and PTN files. All 3 file systems were confirmed to be safe for use in mandibular mesial canals.

근위부 경골 노출을 동반한 벗겨진 손상의 장딴지 근육 피판을 이용한 조기 피복 치험례 (Early Resurfacing Using Gastrocnemius Muscle Flap Transposition for Degloving Injury with Exposure of Proximal Tibia)

  • 정희선;이혜경
    • Journal of Trauma and Injury
    • /
    • 제21권2호
    • /
    • pp.140-143
    • /
    • 2008
  • Degloving injuries result from the tangential force against the skin surface, with resultant separation of the skin and the subcutaneous tissue from the rigid underlying muscle and fascia. These injuries are associated with extensive soft tissue loss and occasionally with exposure of bone, and they require reconstructive modality for resurfacing and successful rehabilitation that considers the vascular anatomy and the timing of the operation. A 19-year-old male patient was transferred to our facility with degloving injury extending from the lower third of the right thigh to the malleolar area. The tibial bone was exposed to a size of $2{\times}3.5cm^2$ on the upper third of the lower leg at the posttraumatic third day. The exposed soft tissue was healthy, and the patient did not have any other associated disease. At the posttraumatic sixth day, one-stage resurfacing was performed with a medial gastrocnemius muscle flap transposition for the denuded bone and a split-thickness skin graft for the entire raw surface. The transposed gastrocnemius muscle attained its anatomical shape quickly, and the operating time was relatively short. No transfusion was needed. This early reconstruction prevented the accumulation of chronic granulation tissue, which leads to contracture of the wound and joint. The early correction of the gastrocnemius muscle flap transposition made early rehabilitation possible, and the patient recovered a nearly full range of motion at the injured knee joint. The leg contour was almost symmetric at one month postoperatively.

Effects of dentin surface preparations on bonding of self-etching adhesives under simulated pulpal pressure

  • Chantima Siriporananon;Pisol Senawongse;Vanthana Sattabanasuk;Natchalee Srimaneekarn;Hidehiko Sano;Pipop Saikaew
    • Restorative Dentistry and Endodontics
    • /
    • 제47권1호
    • /
    • pp.4.1-4.13
    • /
    • 2022
  • Objectives: This study evaluated the effects of different smear layer preparations on the dentin permeability and microtensile bond strength (µTBS) of 2 self-etching adhesives (Clearfil SE Bond [CSE] and Clearfil Tri-S Bond Universal [CTS]) under dynamic pulpal pressure. Materials and Methods: Human third molars were cut into crown segments. The dentin surfaces were prepared using 4 armamentaria: 600-grit SiC paper, coarse diamond burs, superfine diamond burs, and carbide burs. The pulp chamber of each crown segment was connected to a dynamic intra-pulpal pressure simulation apparatus, and the permeability test was done under a pressure of 15 cmH2O. The relative permeability (%P) was evaluated on the smear layer-covered and bonded dentin surfaces. The teeth were bonded to either of the adhesives under pulpal pressure simulation, and cut into sticks after 24 hours water storage for the µTBS test. The resin-dentin interface and nanoleakage observations were performed using a scanning electron microscope. Statistical comparisons were done using analysis of variance and post hoc tests. Results: Only the method of surface preparation had a significant effect on permeability (p < 0.05). The smear layers created by the carbide and superfine diamond burs yielded the lowest permeability. CSE demonstrated a higher µTBS, with these values in the superfine diamond and carbide bur groups being the highest. Microscopic evaluation of the resin-dentin interface revealed nanoleakage in the coarse diamond bur and SiC paper groups for both adhesives. Conclusions: Superfine diamond and carbide burs can be recommended for dentin preparation with the use of 2-step CSE.

Quantification of Pancreas Surface Lobularity on CT: A Feasibility Study in the Normal Pancreas

  • Riccardo Sartoris;Alberto Calandra;Kyung Jin Lee;Tobias Gauss;Valerie Vilgrain;Maxime Ronot
    • Korean Journal of Radiology
    • /
    • 제22권8호
    • /
    • pp.1300-1309
    • /
    • 2021
  • Objective: To assess the feasibility and reproducibility of pancreatic surface lobularity (PSL) quantification derived from abdominal computed tomography (CT) in a population of patients free from pancreatic disease. Materials and Methods: This retrospective study included 265 patients free from pancreatic disease who underwent contrast-enhanced abdominal CT between 2017 and 2019. A maximum of 11 individual PSL measurements were performed by two abdominal radiologists (head [5 measurements], body, and tail [3 measurements each]) using dedicated software. The influence of age, body mass index (BMI), and sex on PSL was assessed using the Pearson correlation and repeated measurements. Inter-reader agreement was assessed using the intraclass correlation coefficient (ICC) and Bland Altman (BA) plots. Results: CT images of 15 (6%) patients could not be analyzed. A total of 2750 measurements were performed in the remaining 250 patients (143 male [57%], mean age 45 years [range, 18-91]), and 2237 (81%) values were obtained in the head 951/1250 (76%), body 609/750 (81%), and tail 677/750 (90%). The mean ± standard deviation PSL was 6.53 ± 1.37. The mean PSL was significantly higher in male than in female (6.89 ± 1.30 vs. 6.06 ± 1.31, respectively, p < 0.001). PSL gradually increased with age (r = 0.32, p < 0.001) and BMI (r = 0.32, p < 0.001). Inter-reader agreement was excellent (ICC 0.82 [95% confidence interval 0.72-0.85], with a BA bias of 0.30 and 95% limits of agreement of -1.29 and 1.89). Conclusion: CT-based PSL quantification is feasible with a high success rate and inter-reader agreement in subjects free from pancreatic disease. Significant variations were observed according to sex, age, and BMI. This study provides a reference for future studies.

악관절의 자기공명영상과 시상단층 방사선촬영상에 관한 비교연구 (A COMPARATIVE STUDY ONMAGNETIC RESONANCE IMAGE AND SECTOGRAPH OF HUMAN TNJ)

  • 이성복;최대균;최부병
    • 대한치과보철학회지
    • /
    • 제31권2호
    • /
    • pp.249-270
    • /
    • 1993
  • For understanding of anatomy, physiology, and diseases of human TMJ, it is required to evaluate quantitatively the movement of the disc and condyle head of mandible. The histologic section of cadaver TMJ were examined, and the magnification of the MR image and its details of anatomy were evaluated. And then a quantitative analytic method, by comparing the Sectograph and the MR image of vital human TMJ, was proposed. For this study, 15 subjects(Male, 24~35years) were selected from a prosthodontic examination randomly, and each subject’s five interocclusal rubber registration records were made on the ICP, and 5, 10, 15, and 20mmjaw opening positions. All subjects were radiographed with a Denar Quint Sectograph Image System(Denar Corp., USA), and imaged with a MRP-20EX MR Image System(0.2T, Permanent Magnet Type, Hitachi Medical Corp., Japan) using an 100mm diameter bilateral type surface coil. These images were traced on the acetate tracing paper, and analyzed In this study, the findings led to the following conclusions. 1. In comparison of the histologic section of autopsy specimen with the MR image at the same section, the size(dimension) of MR image was 70% of the real one. It was possible to recognize the shape of articular disc, anterior and posterior attachments, and adjacent soft tissues, because of the excellent reproducibility of anatomical structure. 2. When we compared the amount of joint space on MR image with that of joint space on sectograph, the amount of joint space on sectograph was significantly greater than that of joint space on MR image, except at the top of condylar head. 3. The position of minimum joint space on sectograph at intercuspal position didn't coincide with the middle position of articular disc on MR image, and was approximately in the anterior third of posterior band of articular disc. 4. The amount of condylar movement on MR image at opening movement was greater than that of articular disc movement. From Intercuspal position to 5mm jaw-opening movement, the condylar movement showed hinge one, and over the range 5mm jaw-opening it suggested hinge & translatory one. 5. In terms of area variation of articular disc measured on MR image in sagittal plane, the area of posterior band increased with increasing the amount of Jaw opening, but the area of anterior band decreased conversely.

  • PDF

의생물 연구 분야에서 집속이온빔장치의 응용 (Applications of Focused Ion Beam for Biomedical Research)

  • 김기우;백생글;박병준;김현욱;류임주
    • Applied Microscopy
    • /
    • 제40권4호
    • /
    • pp.177-183
    • /
    • 2010
  • 집속이온빔장치(focused ion beam, FIB)는 전자보다 무거운 양이온빔을 이용하여 시료를 10~100 nm 정도로 깎아 낼 수 있는 장비로 주로 재료분야에서 활용되어 왔다. 최근 세계적으로 의생물 분야에서의 활용이 점차 늘어나고 있는 추세에 있어 국내연구자들의 이해를 돕기 위해 간단히 기기의 메커니즘과 그 활용예를 기술 하고자 한다. FIB에 주로 사용되는 갈륨(Ga)빔의 특성 때문에 시료의 표면을 효과적으로 쳐 낼 수 있고, 전계 방사형 주사전자현미경(FESEM)을 이용하면 그 표면의 영상을 얻을 수 있다. 이 두 가지 시스템을 하나의 시스템으로 묶어낸 것을 dual beam system이라고 한다. 최근 이러한 시스템을 이용하여 효모, 병원균에 감염된 식물 등이 소개되었으며, 통상적으로 경도가 높아 처리하기 힘든 상아나 어패류의 껍질 등의 시료를 효과적으로 분석한 연구도 있다. 또한 FIB를 이용한 밀링과 FESEM을 이용한 절단면 촬영을 반복하여 얻는 영상을 이용하여 신경계의 연결망을 재구성하려는 연구가 활발하게 진행되고 있다. FIB/FESEM dual beam은 의생물학 분야의 다양한 연구에 활용될 수 있는 유용한 도구며, 의생물 시료의 3차원 연구에 크게 기여할 수 있을 것으로 판단된다.

부신 제거 백서에 티타늄 임플랜트 매식후 주위 골형성에 관한 연구 (The Study of Bone Formation around Titanium Implants Placed in Adrenalectomized Rat's Tibia)

  • 최갑림;김종렬;박봉수;성일용
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제22권3호
    • /
    • pp.274-287
    • /
    • 2000
  • The use of dental implants has increased tremendously in recent years and is expected to increase even more in the future. The successful outcome of any implant procedure is surely dependent on interrelationship of the various components of an equation that includes biocompatibility of implant material, macroscopic and microscopic nature of the implant surface, the status of implant bed, surgical technique, undisturbed healing phase and subsequent prosthetic design and long-term loading phase. The purpose of this study was to clarify the effects of adrenalectomy on the osseointegration of pure titanium implants. Seventy rats, 11 weeks of age, were divided into two groups : an adrenalectomized group and a control group. Titanium screw implant(diameter, 2.0mm; length, 3.5mm) was placed into left tibia of 70 rats, 35 in control group and 35 in the experimental group. The rats were sacrificed at different time interval (1, 2, 3, 4, 6, 8, and 12 weeks after implantation) for histopathologic observation, histomorphometric analysis and immunohistochemistry with fibronectin and CD44 antibody. The results obtained from this study were as follows: 1. Histopathogically, findings, newly formed bone was seen at 3 weeks control group and became lamellar bone at 12 weeks. At 6 weeks, lipocytes were observed in bone marrow space. Thickness of regenerated trabecular bone increased till 6 weeks after then, that decreased gradually. 2. By histomorphometric analysis, marrow bone density and contact ratio of marrow bone to implant decreased significantly from 8 to 12 weeks in experimental group compared to control group and also total bone to implant contact ratio decreased significantly from 4 to 12 weeks in experimental group compared to control group. 3. Fibronectin immunoreactivity was very strong at 3 and 4 weeks control group. And after that reduced gradually. But it was continuously strong from 1 to 12 weeks experimental group. 4. CD44 immunoreactivity was very strong in the newly formed osteoblasts at 3 and 4 weeks control group. But it reacted minimally later. However, it reacted continuously strong from 3 to 12 weeks experimental group. From these results, bone to implant contact ratio decreased gradually from 4 weeks in adrenalectomized group compared to control group. CD44 and fibronectin immunoreactivities were strong at all times in adrenalectomized rats. Therefore, it could be stated that immature bone remained continuously for a long time and not readily proceeded into mature status.

  • PDF

수궐음 심포경근의 해부학적 고찰 (Study on the Anatomical Pericardium Meridian Muscle in Human)

  • 박경식
    • Korean Journal of Acupuncture
    • /
    • 제22권1호
    • /
    • pp.67-74
    • /
    • 2005
  • Objectives : This study was carried to identify the component of the Pericardium Meridian Muscle in human. Methods : The regional muscle group was divided into outer, middle, and inner layer. The inner part of body surface were opened widely to demonstrate muscles, nerve, blood vessels and to expose the inner structure of the Pericardium Meridian Muscle in the order of layers. Results We obtained the results as follows; He Perfcardium Meridian Muscle composed of the muscles, nerves and blood vessels. In human anatomy, it is present the difference between terms (that is, nerves or blood vessels which control the muscle of the Pericardium Meridian Muscle and those which pass near by the Pericardium Meridian Muscle). The inner composition of the Pericardium Meridian Muscle in human is as follows ; 1) Muscle P-1 : pectoralis major and minor muscles, intercostalis muscle(m.) P-2 : space between biceps brachialis m. heads. P-3 : tendon of biceps brachialis and brachialis m. P-4 : space between flexor carpi radialis m. and palmaris longus m. tendon(tend.), flexor digitorum superficialis m., flexor digitorum profundus m. P-5 : space between flexor carpi radialis m. tend. and palmaris longus m. tend., flexor digitorum superficialis m., flexor digitorum profundus m. tend. P-6 : space between flexor carpi radialis m. tend. and palmaris longus m. tend., flexor digitorum profundus m. tend., pronator quadratus m. H-7 : palmar carpal ligament, flexor retinaculum, radiad of flexor digitorum superficialis m. tend., ulnad of flexor pollicis longus tend. radiad of flexor digitorum profundus m. tend. H-8 : palmar carpal ligament, space between flexor digitorum superficialis m. tends., adductor follicis n., palmar interosseous m. H-9 : radiad of extensor tend. insertion. 2) Blood vessel P-1 : lateral cutaneous branch of 4th. intercostal artery, pectoral br. of Ihoracoacrornial art., 4th. intercostal artery(art) P-3 : intermediate basilic vein(v.), brachial art. P4 : intermediate antebrachial v., anterior interosseous art. P-5 : intermediate antebrarhial v., anterior interosseous art. P-6 : intermediate antebrachial v., anterior interosseous art. P-7 : intermediate antebrachial v., palmar carpal br. of radial art., anterior interosseous art. P-8 : superficial palmar arterial arch, palmar metacarpal art. P-9 : dorsal br. of palmar digital art. 3) Nerve P-1 : lateral cutaneous branch of 4th. intercostal nerve, medial pectoral nerve, 4th. intercostal nerve(n.) P-2 : lateral antebrachial cutaneous n. P-3 : medial antebrachial cutaneous n., median n. musrulocutaneous n. P-4 : medial antebrachial cutaneous n., anterior interosseous n. median n. P-5 : median n., anterior interosseous n. P-6 : median n., anterior interosseous n. P-7 : palmar br. of median n., median n., anterior interosseous n. P-8 : palmar br. of median n., palmar digital br. of median n., br. of median n., deep br. of ulnar n. P-9 : dorsal br. of palmar digital branch of median n. Conclusions : This study shows some differences from already established study on meridian Muscle.

  • PDF