Diagnosis of Cast Resin Transformer Using Analysis of Surface Temperature Distribution (표면온도분포 분석을 이용한 몰드 변압기 진단)

  • Lim, Yong-Bae;Chun, Jong-Chul
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07a
    • /
    • pp.444-447
    • /
    • 2003
  • All objects with some temperature above absolute zero radiate in the infrared. The intensity of the infrared radiated from a object defends on the condition and temperature on the surface of the one. The present, these techniques are frequently adopted into diagnosis for electricity equipments. Simply, however, the applied techniques are passive thermal testing for the detection of loosened terminals and overcurrent. In this paper, a infrared thermal imager was applied to high voltage windings of cast resin transformers, and the accumulated value of the result temperatures was used for evaluating remained lifetime of them. At each aging level, dielectric loss tangent test was carried out. The results offered capabilities for deciding the condition of the transformers suffering difficulties to diagnose.

  • PDF

A Study on the High Temperature Tensile Properties of Hyderiedrided Zircaloy-4 (수소화시킨 지르칼로이-4의 고온인장성질에 관한 연구)

  • 조열래;정해용;김인배
    • Journal of the Korean institute of surface engineering
    • /
    • v.23 no.1
    • /
    • pp.44-51
    • /
    • 1990
  • Effects of temperature on the tensile properties of annealed and hydirded Zircaloy-4 plate in which hydrides are precitated paralled to the rolling direction were investigated. The main results obtained are as follows : 1) In annealed Zircaloy-4, yield point phenomenon was found in the temperature range of $200-550^{\circ}C$, while in hydrided alloy the phenomenon was found in the range of $200-400^{\circ}C$. 2) The dynamic strain aging behavior was occurd in the temperature interval of 400-$550^{\circ}C$in both annealed and hydrided Zircaloy-4. 3) The nearly values of yield strength, tensile stength and elongation are obtained in both annealed and hydried Zircaloy-4. From this result, we are led to conclude that the hydrides which are preiptated parallel to the circumferenial direction of nucler fuel are not so harmful for tensile properties of the clad.

  • PDF

Wettability and Water Repellency of Polyester Fabrics Treated by Low Temperture Plasma (저온플라즈마처리에 의한 폴리에스테르직물의 흡수성 및 발수성 변화)

  • 권영아
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.19 no.2
    • /
    • pp.317-328
    • /
    • 1995
  • The objective of this study was to determine the effects of low temperature plasma on the surface properties of polyester fabric with respect to wettability and water repellency. Highly wettable polyester fabric surfaces were obtained by oxygen treatment. The improved wettabililty of oxygen plasma treated fabrics decreased with aging time up to 30 days, and then the wettability remained relatively constant and still exhibited significant improvement compared to that of untreated polyester. Water repellency was significantly improved by tetratfluorocarbon plasma treatment. Such an improvement appears due to introduced fluo\ulcornerrine atoms or a thin fluorocarbon film on the fiber surface. Water repellency remained constant in fact, even after 150 days.

  • PDF

A Study of Intermetetallic Compound Growth in the Sn/Ni Couples(I) : Intermetallic Compound Formation and Growth Kineties (Sn/Cu 및 Sn/Ni 계면에서 금속간화합물의 형성 및 성장에 관한 연구(I) : 금속간화합물의 생성, 성장반응 및 속도론)

  • 김용혁;이성래
    • Journal of the Korean institute of surface engineering
    • /
    • v.22 no.1
    • /
    • pp.3-9
    • /
    • 1989
  • The intermetallic compount formation, growth rections, and growth kinetices as functions of the aging temperaturess, time, and the condition of substarte have invedtigted in the Sn/Cu and Sn/Ni bimetal couples. The η'-phase (Cu6Sn5) and $\delta$-phase (Ni3Sn4) were only found to grow at 20 and $70^{\circ}C$in the Sn/Cu and Sn/Ni bimetallic coples repectively. Above that temperatures, all other compounds were formed in sequence of high Sn content plase and the metastable Cu41Sn11 was formed at agend $200^{\circ}C$. The ectivation energy for the growth of intermetallic compounds was 14.7Kxal/mole in the Sn/Cu interface and 26.7Kcal/mole in the Sn/Ni interface.

  • PDF

Manufacturing Technique of Suspension Insulator far Distribution Lines Using Composite materials (배전급 고분자 현수애자의 제조기술 개발)

  • 홍진영;김영성;지응서;김영찬;백주흠;김동욱
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1996.11a
    • /
    • pp.306-310
    • /
    • 1996
  • In this paper a series of developing process for an insulator which can be employed in overhead distribution lines, using polymeric composite materials, is introduced. In order to design an insulator for heavily polluted area, weathershed of alternating type was adopted, which could have longer leakage distance. Modified EVA was used as surface material which has good electrical and mechanical characteristics as well as superior chemical stability. FRP core was covered with above surface material through heat shrinking process. By standardization of each process, higher productivity and lower production cost could be ensured. The developed insulator has been put under various tests including long-term field test and artificial aging test and satisfactory results were obtained.

  • PDF

Study on Rapid Removal of Suspended Solid by Modified Magnetite Powder (마그네타이트 분말의 표면개질화에 의한 부유물질의 고속 제거)

  • 이혁희;박상원
    • Journal of Environmental Science International
    • /
    • v.12 no.9
    • /
    • pp.1017-1023
    • /
    • 2003
  • The high speed elimination process of suspended solid was investigated to treat the pulp waste water by using surface modified magnetite particle and magnetic power. The effects of the various aluminum salts such as Al(NO$_3$)$_3$ㆍ9$H_2O$, AlC1$_3$ㆍ6$H_2O$, $Al_2$(SO$_4$)$_3$ㆍ13∼14 on the COD, BOD and suspended solid were systematically studied. It has been found that the 2.0 wt% of Al was most effective for the modification of Fe$_3$O$_4$ powder and then best for the treatment of pulp waste water, Optimum quantity of modified magnetite in this study was 12 wt%, and aging time was found to be 12 hours. Comparing with the conventional process, the required time for SS removal was drastically decreased. BOB and COD were also effectively removed when applied to the pulp wastewater.

Flashover Failure of Polymer Insulator in Distribution Lines (배전용 폴리머애자의 섬락고장)

  • 한재홍;이병성;김찬영;윤태상
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.767-770
    • /
    • 2000
  • This study was investigated for searching a cause of flashover failure of polymer insulator and preparing countermeasures. Hydrophobicity, microstructure and chemical structural change of polymer weathershed were studied by polymer characterization methods. In addition, the electrical properties such as power frequency dry flashover voltage/impulse voltage tests, contamination characteristics were carried out. The hydrophobicity of polymer weathershed was decreased significantly and cracks were observed on the surface. Also, the electrical characteristics did not satisfy the KEPCO specification. The failed polymer insulators showed the more leakage current than 4 years service-aged ones. From the result, it can be concluded that the flashover failure of polymer insulator was attributed to the surface aging and severe contamination.

  • PDF

Temperature Distribution of Tracking Degradation Using IRR-Camera (적외선방사카메라를 이용한 트래킹열화 온도분포)

  • Jeong, Seung-Chun;Lim, Jang-Seob;Chen, Jong-Cheol;Jung, Woo-Seong;Lee, Jin
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.05a
    • /
    • pp.59-63
    • /
    • 2000
  • The conventional tracking testing as IEC-60587 is widely used in surface aging measurement of outside insulator because those testing can carry out very short time in Lab testing. Also IEC-60587 testing is able to offer the standard judgement of relative degradation level of outside HV machine. Therefore it is very useful method compare to previous conventional tracking testing method and effective Lab testing method. But surface discharges(SD) have very complex characteristics of discharge pattern so it is required estimation research to development of precise analysis method. In recent, the study of IIR-camera is carrying out discover of temperature of power equipment through condition diagnosis and system development of degradation diagnosis. In this study, SD occurred from IEC-60587 is measured with partial temperature distribution in real time, the degradation grade of SD is analyzed through produced patterns in IEC-60587 according to applied time.

  • PDF

Analysis of Insulation Aging in Operating High Voltage Motors (운전중인 고압전동기에서 절연열화 분석)

  • Kim, Hee-Dong;Ju, Young-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2175-2178
    • /
    • 2005
  • During normal machine operation, partial discharge(PD) measurements were performed with turbine generator analyzer(TGA) in five high voltage motors(rated 6.6kV). These high voltage motors were installed with 80pF capacitive couplers at the terminal box. The PD patterns were displayed two dimensional and three dimensional. TGA summarizes each plot with two quantities such as the normalized quantity number(NQN) and the peak PD magnitude(Qm). Off-line PD measurements were conducted on five motors. These motors were energized to 3.81kV. The PD levels in pC were measured with a conventional digital PD detector. The comparison of positive to negative PD indicates whether the defect elements of PD are within the insulation or on the insulation surface. Internal discharges were generated in phase A, B and C of COP-B and pulv.-B, in phase B of Pulv. C and in phase C of Pulv.-D motor. Discharge at conductor surface was discovered in phase A of Pulv. D motor. Slot discharges occurred in three phases of Pulv. E motor.

  • PDF

The Analysis of Weibull Distribution on the Monitoring of IRR Camera (적외선 모니터링 관측의 와이블 분포해석)

  • Lim, Jang-Seob;Kim, Jin-Gook;Lee, Hack-Hyun;Lee, Jin;Lee, Woo-Sun
    • Proceedings of the KIEE Conference
    • /
    • 2004.11a
    • /
    • pp.264-267
    • /
    • 2004
  • The conventional testing as IEC-60587 is widely used in surface aging measurement of outside insulator those testing can carry out very short time in Lab testing. Also IEC-60587 testing is able to offer the standard judgement of relative degradation level of out side HV machine. Therefore it is very useful method compare to previous conventional tracking testing method and effective Lab testing method, But surface discharges(SD) have very complex characteristics of discharge pattern so it is required estimation research to development of precise analysis method. In recent, the study of IRR Camera is carrying out discover of temperature of power equipment through condition diagnosis and system development of degradation diagnosis.