Choi, Yoo Min;Kim, Jong Uk;Kim, Lak Hyung;Yook, Tae Han
Journal of Acupuncture Research
/
v.34
no.2
/
pp.75-82
/
2017
Objectives : The purpose of this study was to determine the electrical properties of the buccal area using facial surface electromyography (sEMG). Methods : This research was conducted on 44 healthy participants irrespective of their sex. Surface electrodes were attached to the midpoints of three imaginary lines connecting ST4 (Dicang) to ST6 (Jiache), ST4 to SI18 (Quanliao), and ST4 to the center point of SI18 and ST6. Then, the participants were trained in the movement that included a comprehensive action of buccal area. While the participants were performing the motion, sEMG values ($E_1$, $E_2$, $E_3$) and the distance change of the three imaginary lines ($D_1$, $D_2$, $D_3$) were measured. The data were statistically analyzed using SPSS ver. 22.0. Results : Significant differences were observed in the distance changes ($D_1$>$D_3$, $D_2$>$D_3$) and sEMG values ($E_1$<$E_2$<$E_3$). Moreover, there were positive correlations between $D_1$ and $E_1$, $D_2$ and $E_2$. Conclusion : We suggest that the measurement at ST4 to the center point of ST6 and SI18 with this motion would be adequate to check the electrical characteristics of the buccal area.
The Journal of Korea Institute of Information, Electronics, and Communication Technology
/
v.2
no.1
/
pp.17-22
/
2009
In this paper, we extract well-known parameters such as zero crossing rate(ZCR), low band energy(Band) and median frequency(MDF) from surface electromyogram (EMG), and compare to evaluate themselves as measures for fatigue. In experiments, 3 males and 3 females volunteered to participate in surface EMG recordings placed on the biceps brachii and each recording experiment continued until exhaustion.
The purpose of this study was to investigate the effects of vibration exercise using surface electromyography. Seven male collegiate wrestlers were participated in this study. Each subject stood on the platform and the vibration was induced for 1min. WEMG8 EMG system was used to record muscle activity from Vastus lateralis, Biceps Femoris, Tibialis Anterior, and Gastrocnemius. The EMG data were sampled for 30 sec. during non-vibration and vibration half squat position, respectively. The raw data were band pass filtered to remove noise and full wave rectified Paired sample t-test were performed to see the differences of maximum and average EMG between non-vibration and vibration trials. The results indicated that vibration produced much more muscle contraction than that of non-vibration trial for all selected muscles even though the significant difference was found only from Biceps Femoris. This phenomenon was due to the individual differences so care must be taken to evaluate vibration intensity and position before personal training.
Fall detection and prevention technologies play a pivotal role in ensuring the well-being of individuals, particularly those living independently, where falls can result in severe consequences. This paper addresses the challenge of accurate and quick fall detection by proposing a Bayesian probability-based measure applied to surface electromyography (sEMG) signals. The proposed algorithm based on a Bayesian filter that divides the sEMG signal into transient and steady states. The ratio of posterior probabilities, considering the inclusion or exclusion of the transient state, serves as a scale to gauge the dominance of the transient state in the current signal. Experimental results demonstrate that this approach enhances the accuracy and expedites the detection time compared to existing methods. The study suggests broader applications beyond fall detection, anticipating future research in diverse human-robot interface benefiting from the proposed methodology.
Journal of the Korea Institute of Information and Communication Engineering
/
v.10
no.10
/
pp.1779-1785
/
2006
This paper presents a method of virtual robot arm control by EMG pattern recognition using the proposed hybrid system. The proposed hybrid system is composed of the LVQ and the SOFM, and the SOFM is used for the preprocessing of the LVQ. The SOFM converts the high dimensional EMG signals to 2-dimensional data. The EMG measurement system uses three surface electrodes to acquire the EMG signal from operator. Six hand gestures can be classified sufficiently by the proposed hybrid system. Experimental results are presented that show the effectiveness of the virtual robot arm control by the proposed hybrid system based classifier for the recognition of hand gestures from EMG signal patterns.
Purpose: This study examined the muscle activity of the trunk muscles during weight shifting exercises on a stable and unstable surface. Methods: Ten healthy young subjects (4 males, 6 females) with no medical history of lower-extremity or lumbar spine disease were enrolled in this study. The muscle activity was recorded using surface electromyography (EMG) electrodes from the both sides of the external obliques and erector spinae muscles. Results: The EMG activities of the both rectus abdominalis, both external obliques and erector spinae muscles were significantly higher when the weight shifting exercise was performed on a firm surface than when a balance pad with a balance ball was used. In weight shifting exercises, the EMG activity of the contralateral external obliques and erector spinae muscles was significantly higher than that of the ipsilateral external obliques and erector spinae muscles under all three support surface conditions. Conclusion: Performing weight shifting exercise using an unstable surface is a useful method for facilitating the trunk-muscle strength and trunk stability.
Kim, Su-Jeong;Weon, Jong-Hyuck;Oh, Jae-Seop;Kwon, Oh-Yun
Physical Therapy Korea
/
v.13
no.3
/
pp.102-110
/
2006
To improve trunk stability, various exercise protocols were introduced into the clinical field. Trunk and lumbar stability exercises on unstable surfaces are especially recommended to improve lumbar stability. The purpose of this study was to compare abdominal oblique muscle activity during leg raising in hook-lying position among 3 different type of surface conditions (on floor (F), vestibular board (VB), and foam roll (FR)). Sixteen able-bodied volunteers, who had no medical history of lower extremity or lumbar spine disease, were recruited for this study. Surface electromyography (EMG) activity was recorded from the internal and external oblique muscles of both sides. The normalized EMG activity was compared using a one-way repeated ANOVA. The results showed that the EMG activities of the internal oblique and external oblique of the lifted leg side during straight leg raising significantly increased under the FR condition when compared to the F condition. There was no significant difference of the EMG activity in abdominal oblique muscles between the VB and the FR conditions. The EMG activity of the internal oblique of supported leg side during the straight leg raising was significantly greater under the FR condition than the VB and F conditions (p<.05). The composition ratio of EMG activity of internal oblique muscles during straight leg raising was significantly increased under the FR condition. Therefore, straight leg raising exercise on foam roll in hook lying position could be beneficial to improve trunk and lumbar stability.
The aim of this study was to examine the characteristics in duration and amplitude of the submental muscle activities during dry and wet swallowing. We examined the middle suprahyoid muscle activities in 32 normal adult women during three swallowing conditions, that is, dry as well as 5 mL & 10 mL water swallowings, using a surface EMG. From the results, there were significant differences in duration: the longest in dry swallowing and shortest in 5 mL water swallowing. However, the mean amplitude per msec increased as the duration decreased. This may imply motor equivalence in swallowing stating that duration and amplitude are complementary in order to achieve a given swallowing goal.
A need exists for the accurate identification of time series models having time varying parameters, as is important in the case of real time identification of nonstationary EMG signal. Thls paper describes real time identification and muscle fatigue monitoring method of nonstationary EMG signal. The method is composed of the efficient identifier which estimates the autoregressive parameters of nonstationary EMG signal model, and its real time implementation by using T805 parallel processing computer. The method is verified through experiment with real EMG signals which are obtained from surface electrode. As a result, the proposed method provides a new approach for real time Implementation of muscle fatigue monitoring and the execution time is 0.894ms/sample for 1024Hz EMG signal.
We selected six kinds of stretching exercises that can be easily acquired and put to practical use by back pain patients and arranged the practicing order of the exercising method after measuring the % MlVC of the muscle power when a normal person was exercising with a surface EMG. Among the patients complaining of back pain, 20 case groups were given the selected exercise and physical therapy, and 20 control groups were only given a physical therapy. Before and 2 weeks, 4weeks, 6 weeks and 8 weeks after the exercise therapy, a muscle power was measured with a fitness machine and the effectiveness of the exercise was compared. After six weeks difference of the muscle power between the case group and control group was shown, and after 8weeks the case group manifested the stronger muscle power than that of the control group in both male and female. Exercising therapy clearly seems to be helpful in strengthening the muscle power of the back pain patients.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.