• 제목/요약/키워드: support structure tomography

검색결과 4건 처리시간 0.022초

Carved Merocel®을 이용한 비골골절의 고정 (Fixation of Nasal Bone Fracture with Carved Merocel®)

  • 공정식;정재아;강소라;김양우;전영우
    • 대한두개안면성형외과학회지
    • /
    • 제12권2호
    • /
    • pp.93-96
    • /
    • 2011
  • Purpose: In most cases of nasal bone fracture, closed reduction with internal or external splint fixation approach is selected. However, because of indiscriminate insertion of the internal splint without considering of anatomical difference or deformity, insufficient fixation happens frequently that need additional fixation. Therefore, we suggest a new method for providing adequate support in reduced nasal bone by carving $Merocel^{(R)}$ that is fixed for the anatomical structure. Method: Closed reduction and internal fixation with carved $Merocel^{(R)}$ was performed in 15 nasal bone fracture patients from March, 2010 to July, 2010. Each patient was evaluated by physical examination, facial photographic check, simple X-ray, and computerized tomography. On the first day post-operation, location of packing and amount of reduction were checked by follow up X-ray and computerized tomography. In addition, patients' symptoms were evaluated. During the 3-month post-op follow up at out-patient clinic, operator, 2 doctors in training and one assistant performed the objective evaluations by physical examination on nasal dorsal hump, nasal deviation, nasal depression, nasal breath difficulty, and nasal airway obstruction. A survey of subjective patients' satisfaction in 4-stages was also performed. Results: The results of follow-up computerized tomography of the 15 patients revealed that 11 patients had good reduced state. Three patients with combined maxillary frontal process fracture had over reductions. A survey performed on the first day post-operation showed that 14 of 15 patients answered that their current symptoms were more than tolerable. At the 3-month follow-up physical exam, one case had a dorsal hump. However, there were no nasal deviations, nasal depressions, nasal breath difficulties, or nasal airway obstructions. Twelve of the 15 patients answered more than moderate on the 3-month survey. Conclusion: Intranasal packing after carving the $Merocel^{(R)}$ considering anatomical structure is a new effective method to promote proper-reduction, maintain stability, and minimize patients' symptoms by addition of a simple procedure.

슬러리 코팅 공정으로 제조된 Fe 폼의 기공 특성에 미치는 Fe 및 Fe2O3 분말의 혼합 비율의 영향 (The Effect of Fe and Fe2O3 Powder Mixing Ratios on the Pore Properties of Fe Foam Fabricated by a Slurry Coating Process)

  • 최진호;정은미;박다희;양상선;한유동;윤중열
    • 한국분말재료학회지
    • /
    • 제21권4호
    • /
    • pp.266-270
    • /
    • 2014
  • Metal foams have a cellular structure consisting of a solid metal containing a large volume fraction of pores. In particular, open, penetrating pores are necessary for industrial applications such as in high temperature filters and as a support for catalysts. In this study, Fe foam with above 90% porosity and 2 millimeter pore size was successfully fabricated by a slurry coating process and the pore properties were characterized. The Fe and $Fe_2O_3$ powder mixing ratios were controlled to produce Fe foams with different pore size and porosity. First, the slurry was prepared by uniform mixing with powders, distilled water and polyvinyl alcohol(PVA). After slurry coating on the polyurethane(PU) foam, the sample was dried at $80^{\circ}C$. The PVA and PU foams were then removed by heating at $700^{\circ}C$ for 3 hours. The debinded samples were subsequently sintered at $1250^{\circ}C$ with a holding time of 3 hours under hydrogen atmosphere. The three dimensional geometries of the obtained Fe foams with an open cell structure were investigated using X-ray micro CT(computed tomography) as well as the pore morphology, size and phase. The coated amount of slurry on the PU foam were increased with $Fe_2O_3$ mixing powder ratio but the shrinkage and porosity of Fe foams were decreased with $Fe_2O_3$ mixing powder ratio.

A real-time sorting algorithm for in-beam PET of heavy-ion cancer therapy device

  • Ke, Lingyun;Yan, Junwei;Chen, Jinda;Wang, Changxin;Zhang, Xiuling;Du, Chengming;Hu, Minchi;Yang, Zuoqiao;Xu, Jiapeng;Qian, Yi;She, Qianshun;Yang, Haibo;Zhao, Hongyun;Pu, Tianlei;Pei, Changxu;Su, Hong;Kong, Jie
    • Nuclear Engineering and Technology
    • /
    • 제53권10호
    • /
    • pp.3406-3412
    • /
    • 2021
  • A real-time digital time-stamp sorting algorithm used in the In-Beam positron emission tomography (In-Beam PET) is presented. The algorithm is operated in the field programmable gate array (FPGA) and a small amount of registers, MUX and memory cells are used. It is developed for sorting the data of annihilation event from front-end circuits, so as to identify the coincidence events efficiently in a large amount of data. In the In-Beam PET, each annihilation event is detected by the detector array and digitized by the analog to digital converter (ADC) in Data Acquisition Unit (DAQU), with a resolution of 14 bits and sampling rate of 50 MS/s. Test and preliminary operation have been implemented, it can perform a sorting operation under the event count rate up to 1 MHz per channel, and support four channels in total, count rate up to 4 MHz. The performance of this algorithm has been verified by pulse generator and 22Na radiation source, which can sort the events with chaotic order into chronological order completely. The application of this algorithm provides not only an efficient solution for selection of coincidence events, but also a design of electronic circuit with a small-scale structure.

요추부 협착에서의 피질골 궤도 나사못 고정의 초기 실패 사례에 대한 고찰 (Early Failure of Cortical-Bone Screw Fixation in the Lumbar Spinal Stenosis)

  • 권지원;김진규;하중원;문성환;이환모;박융
    • 대한정형외과학회지
    • /
    • 제55권5호
    • /
    • pp.405-410
    • /
    • 2020
  • 목적: 퇴행성 요추부 척추 질환에 대한 수술적 치료로 척추 경 나사못(pedicle screw) 삽입술이 전통적으로 사용되어왔다. 이에 대한 대안으로 제시된 피질골 궤도 나사못(cortical-bone trajectory screw)은 덜 침습적인 후방 요추부 고정이 가능한 점과 몇몇의 생체 역학 연구에서 보고한 우수한 기계적 안정성을 장점으로 가지고 있다. 본 연구의 목적은 후방 감압술 후 후방 고정술 및 유합을 시행한 환자에 있어 피질골 궤도 나사못 고정술의 초기 실패에 관한 사례의 임상적 및 방사선적 결과를 알아보고자 함에 있다. 대상 및 방법: 요추의 퇴행성 척추 협착 및 척추 전방 전위에 대한 전통적인 척추 경 나사못 고정을 대안하여 피질골 궤도 나사못을 사용하여 2013년부터 2018년까지 수술적 치료를 시행한 311명의 환자를 대상으로 하였다. 수술 후 조기 고정 실패는 수술 후 6개월째, 외래 추시에서 시행한 컴퓨터 단층촬영(computed tomography) 및 방사선 사진상 나사못의 이완, 이탈 및 파손과 같은 고정 실패가 일어날 시로 정의하였다. 결과: 조기 고정 실패는 311예 중 46예(14.8%), 나사못 이완이 46예(14.8%), 이탈이 12예(3.9%), 파손이 4예(1.3%)에서 발생하였다. 해당 고정 실패가 일어난 부위 분석 시, L1이 7예(15.2%), L2가 3예(6.5%), L3가 4예(8.7%), L4가 4예(8.7%), L5가 4예(8.7%), 그리고 S1이 24예(52.2%)였다. 주로 말단 피질골 궤도 나사못 중에서도 S1 나사못에서 이완, 이탈 및 파손과 같은 고정 실패가 주로 발생하였다. 결론: 피질골 궤도 나사못 고정은 기존의 척추 경 나사못 고정과 비교했을 때 동등한 임상 결과 또는 적은 합병증을 나타낼 수 있는 하나의 대안이 될 수 있으나 골다공증이 있거나 특히 L5-S1 유합부위에서 전방지지구조가 되지 않는 조건일 때, 이완, 이탈, 파손 등의 조기 고정 실패가 나타나는 결과가 있었다.