• Title/Summary/Keyword: support rotation angle

Search Result 36, Processing Time 0.029 seconds

The Relationship Between Hip Adduction Angle of Ober Test According to Tibial Rotation and Length of the Iliotibial Band (정강뼈 돌림에 따른 오버테스트의 엉덩관절 모음 각도와 엉덩정강뼈 환 길이의 상관관계)

  • Park, Joo-Hee;Lee, Sa-Gyeom
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.12 no.1
    • /
    • pp.43-49
    • /
    • 2017
  • PURPOSE: This study investigated the relationship among hip adduction angle, tibial rotation, and ITB length during an Ober test to determine the most appropriate position for performing the test. METHODS: The study included thirty-nine asymptomatic participants (23 males, 16 females). Their hip adduction angles were measured using the Ober test during three tibial rotation conditions (internal tibial rotation, external rotation, and neutral position). ITB length was calculated by measuring the position of the patella to lateral femoral condyle using ultrasonography (patella-condyle distance; PCD). RESULTS: The relationship among hip adduction angle, tibial rotation, and ITB length was analyzed under the three conditions using the Pearson correlation. The hip adduction angle of the internal tibial rotation, the external rotation, and the neutral position were significantly related to ITB length. Moreover, the hip adduction angle measured during the internal tibial rotation had the highest correlation with ITB length among the three conditions (r=.58, p<.001). CONCLUSION: Internal tibial rotation caused by the Ober test led to increased iliotibial band (ITB) tension and a decreased adduction angle. These findings support that tibial rotation influences the flexibility of ITB. Therefore, therapists should consider the position of the internal tibial rotation when taking measurements using an Ober test.

Effect of Pelvic Compression Belt on Abdominal Muscle Activity, Pelvic Rotation and Pelvic Tilt During Active Straight Leg Raise

  • Jo, Eun-young;An, Duk-hyun
    • Physical Therapy Korea
    • /
    • v.26 no.1
    • /
    • pp.67-74
    • /
    • 2019
  • Background: Uncontrolled lumbopelvic movement leads to asymmetric symptoms and causes pain in the lumbar and pelvic regions. So many patients have uncontrolled lumbopelvic movement. Passive support devices are used for unstable lumbopelvic patient. So, we need to understand that influence of passive support on lumbopelvic stability. It is important to examine that using the pelvic belt on abdominal muscle activity, pelvic rotation and pelvic tilt. Objects: This study observed abdominal muscle activity, pelvic rotation and tilt angles were compared during active straight leg raise (ASLR) with and without pelvic compression belt. Methods: Sixteen healthy women were participated in this study. ASRL with and without pelvic compression belt was performed for 5 sec, until their leg touched the target bar that was set 20 cm above the base. Surface electromyography was recorded from rectus abdominis (RA), internal oblique abdominis (IO), and external oblique abdominis (EO) bilaterally. And pelvic rotation and tilt angles were measured by motion capture system. Results: There were significantly less activities of left EO (p=.042), right EO (p=.031), left IO (p=.039), right IO (p=.019), left RA (p=.044), and right RA (p=.042) and a greater right pelvic rotation angle (p=.008) and anterior pelvic tilt angle (p<.001) during ASLR with pelvic compression belt. Conclusion: These results showed that abdominal activity was reduced while the right pelvic rotation angle and anterior pelvic tilt angle were increased during ASLR with a pelvic compression belt. In other words, although pelvic compression belt could support abdominal muscle activity, it would be difficult to control pelvic movement. So pelvic belt would not be useful for controlled ASLR.

Kinematic Skill Analysis of the Turn Motion and Release Phase in Female Hammer Throw (여자해머던지기 턴 동작과 투사국면에 대한 운동학적 기술 요인 분석)

  • Chung, Nam-Ju;Kim, Jae-Pil;Song, Ok-Heung
    • Korean Journal of Applied Biomechanics
    • /
    • v.20 no.4
    • /
    • pp.429-436
    • /
    • 2010
  • The purpose of this study was to analyze the kinematic factors and throwing variables for the 3-turn and 4-turn techniques and for release as well as to provide technical advice for improving athletic performance in hammer throwing. Data analysis led to the following conclusions: To increase the rotation speed for the 3-turn and 4-turn techniques, the time elapsed during the 1-foot support period should be decreased the distance between the rotating foot and the rotation axis should be small and the height of the hip joint should be increased at the times of release The throwing angle at the moment of release should be more than 40 degrees, and the throwing position should be taken vertically high at the shoulder joints. To accelerate the motion of the hammer, the speed should not be reduced during the 1-foot support period but should be increased during the 2-foot support period for much greater acceleration. In the 3-turn technique, the angles of the shoulder axis and hummer string should be dragged angle at the maximum point and lead angle at the minimum point, and dragged angle at the maximum and minimum points in the 4-turn at the time of relase The upper body should be quickly bent backward, the knee angle should be extended, and the angles of the shoulder axis and hammer string should be dragged angle close to 90 degrees.

Direction Dependence of the Perception of the Support Rotation While Quiet Standing (정적서기 상태에서 지지면 회전 인지능력의 방향별 차이)

  • Jeon, H.J.;Heo, J.H.;Jeon, H.M.;Yun, J.S.;Kweon, Y.R.;Eom, G.M.
    • Journal of Biomedical Engineering Research
    • /
    • v.38 no.2
    • /
    • pp.57-61
    • /
    • 2017
  • The purpose of this study was to investigate the effect of direction (pitch and roll) on the perception of support surface rotation while standing. Thirty young healthy subjects participated in this study. Support surface was rotated at an unexpected instant in a very slow speed (0.2 deg/s). The direction of support surface rotation was randomly chosen among pitch (forward and backward) and roll (right and left) directions. The experiment was performed with eyes open and closed. Perception performance was evaluated by the perception threshold, defined as the rotation angle of the surface at the instant when a subject recognized that the support surface was moving. Results showed that the perception threshold was smaller for roll directions than pitch directions irrespective of vision and gender (p < 0.01). This indicates that the perception of support surface rotation is more sensitive in roll direction than in pitch direction. Among three sensory functions related to postural perception, the effect of vestibular and visual functions on the direction difference of the perception should be little because of the very slow surface rotation and independence on visual conditions. Therefore, the direction dependence of perception would have been affected mainly by the somatosensory function.

Simple P-I diagram for structural components based on support rotation angle criteria

  • Kee, Jung Hun;Park, Jong Yil
    • Advances in concrete construction
    • /
    • v.10 no.6
    • /
    • pp.509-514
    • /
    • 2020
  • In the preliminary design phase of explosion-proof structures, the use of P-I diagram is useful. Based on the fact that the deformation criteria at failure or heavy damage is significantly larger than the yield deformation, a closed form solution of normalized P-I diagram is proposed using the complete plastic resistance curve. When actual sizes and material properties of RC structural component are considered, the complete plasticity assumption shows only a maximum error of 6% in terms of strain energy, and a maximum difference of 9% of the amount of explosives in CWSD. Thru comparison with four field test results, the same damage pattern was predicted in all four specimens.

The Three Dimensional Analysis of the Upper Body's Segments of the Elderly during Walking (보행 시 노인의 상체 움직임에 대한 3차원적 분석)

  • Kim, Hee-Su;Yoon, Hee-Joong;Ryu, Ji-Seon;Kim, Tae-Sam
    • Korean Journal of Applied Biomechanics
    • /
    • v.14 no.3
    • /
    • pp.1-15
    • /
    • 2004
  • The purpose of this study was to investigate the kinematic variables of the upper part of the body for 8 elderly men during walking. For this study, kinematic data were collected using a six-camera (240Hz) Qualisys ProReflex system. The room coordinate system was right-handed and fixed in space, with righted orthogonal segment coordinate systems defined for the head, trunk, and pelvis. Based on a rigid body model, reflective marker triads were attached on the 3 segments. Three-dimensional Cartesian coordinates for each marker were determined at the time of recording using a nonlinear transformation(NLT) technique with ProReflex software (Qualisys, Inc.). Coordinate data were low-pass filtered using a fourth-order Butterworth with cutoff frequency of 6Hz. Three-dimensional angles of the head, trunk, and pelvis segment were determined using a Cardan method. On the basis of each segment angle, angle-angle plot used to estimated the movement coordinations between segments. The conclusions were as follows; (1) During the support phase of walking, the elderly people generally kept their, head the flexional and abductional posture. Particularly, the elderly displayed little internal/external rotation. (2) The elderly people showed extensional and external rotation postures in the trunk movement. Particularly, It showed the change from adduction into abduction at the heel contact event of the stance phase. (3) The elderly people showed almost same pelvis movement from the flexion into extension, from the abduction into adduction, and from internal rotation into external rotation at the mid stance and toe off of the stance phase.

Multi-View Image Parking Assistant System using Vehicle Data (차량 정보를 이용한 멀티뷰 영상 주차 보조 시스템)

  • Lee, Min-Goo;Jung, Kyung-Kwon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.2
    • /
    • pp.266-272
    • /
    • 2012
  • This paper presents a parking assistant system of multi-view using vehicle data. Proposed system provides the driver with three direction of the scenes surrounding vehicle. Depending on the handle rotation, the proposed system displays views from multiple wide-angle CCD cameras on the laptop screen to reduce blind spots, support smooth parallel or garage parking, and support comfortable and safe driving. The handle angle and gear position are obtained from ABS ECU through OBD-II port. The performance of proposed system is validated by vehicle experiments.

Motion Change of the Trunk and Upper Extremity Segment to Putting the Wrist Support on Throwing in Bowling (볼링 투구 동작 시 손목 지지대 착용에 따른 몸통과 상지 분절의 움직임 변화)

  • Kim, Tae-Sam;Lee, Hoon-Pyo;Han, Hee-Chang
    • Korean Journal of Applied Biomechanics
    • /
    • v.16 no.3
    • /
    • pp.33-41
    • /
    • 2006
  • This study was to analysis three dimension angle of the upper extremity segment and trunk to putting the protector in women bowlers. For this study, the subjects selected 4 players of national and university team. All subjects putted in the same wrist support to satisfy the experiment conditions. To get three dimensions position coordination of swing motion used for 6 ProReflex MCU 240 camera produced by Qualisys. After position coordination calculation, Three dimension angle of the trunk and the upper extremity segment calculated for Matlab 6.5. the result is following; In the trunk motion, there were little differences among the subjects in a flexion and extension change. There were a lot of differences in motion change of the abduction-adduction and internal-external rotation, but the motion types translated to the adduction-abduction-adduction and from the internal rotation toward the external rotation. In the upper arm segment the Flexion and extension showed a consistent motion in the down swing and up swing phase. And the motion change of abduction-adduction and pronation-supination showed a abduction-adduction-abduction and pronation-supination change during swing phase. In the forearm segment changes, it showed a lot of differences among the subjects and a similar change with the upper arm segment. Especially, the hand segment showed a supination motion from the backswing apex to release phase, but for increasing a rotation velocity of ball, the hand segment translated toward pronation in follow throw phase.

Experimental Study on Characteristics of Deformation for Concrete Track on Railway Bridge Deck End induced by Bridge End Rotation (철도교량 단부 회전에 따른 콘크리트 궤도의 변형특성에 관한 실험적 연구)

  • Lim, Jongil;Song, Sunok;Choi, Jungyoul;Park, Yonggul
    • Journal of the Korean Society for Railway
    • /
    • v.16 no.3
    • /
    • pp.217-225
    • /
    • 2013
  • In this study, by considering the rail fastening support distance and the distance between the bridge and the abutment, the behavior of concrete track installed on a railway bridge end deck and the bridge end rotation were analyzed. In order to analyze the track-bridge interaction, bridge and abutment specimens with concrete track structures were designed and used in laboratory testing. At a constant fastening support distance, an increase in the bridge end rotation caused an increase in the displacement of the rail. Therefore, the displacement of the rail directly affects the rail and clip stress. Further, it is inferred that the results of multiple regression analysis obtained using measured data such as angle of bridge end rotation and fastening support distance can be used to predict the track-bridge interaction forces acting on concrete track installed on railway bridge deck ends.

Research on the cable-driven endoscopic manipulator for fusion reactors

  • Guodong Qin;Yong Cheng;Aihong Ji;Hongtao Pan;Yang Yang;Zhixin Yao;Yuntao Song
    • Nuclear Engineering and Technology
    • /
    • v.56 no.2
    • /
    • pp.498-505
    • /
    • 2024
  • In this paper, a cable-driven endoscopic manipulator (CEM) is designed for the Chinese latest compact fusion reactor. The whole CEM arm is more than 3000 mm long and includes end vision tools, an endoscopic manipulator/control system, a feeding system, a drag chain system, support systems, a neutron shield door, etc. It can cover a range of ±45° of the vacuum chamber by working in a wrap-around mode, etc., to meet the need for observation at any position and angle. By placing all drive motors in the end drive box via a cable drive, cooling, and radiation protection of the entire robot can be facilitated. To address the CEM motion control problem, a discrete trajectory tracking method is proposed. By restricting each joint of the CEM to the target curve through segmental fitting, the trajectory tracking control is completed. To avoid the joint rotation angle overrun, a joint limit rotation angle optimization method is proposed based on the equivalent rod length principle. Finally, the CEM simulation system is established. The rationality of the structure design and the effectiveness of the motion control algorithm are verified by the simulation.