• Title/Summary/Keyword: support parameters

Search Result 1,374, Processing Time 0.033 seconds

Cyclic Loading Test for Exposed Column-base Plate Connections of Small-size Steel Structures (소규모 철골조 노출형 주각부의 반복가력 실험)

  • Lim, Woo-Young;You, Young-Chan;Yoo, Mi-Na
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.2
    • /
    • pp.34-45
    • /
    • 2017
  • Cyclic loading tests for a total of nine test specimens were performed to evaluate the seismic performance of the exposed steel column-base plate connections. From the tests, flexural strength, deformation capacity, energy dissipation, and initial stiffness were investigated. The primary test parameters were the thickness of base-plate, embedment length of anchor bolt, the presence of hook, and rib plates. Test results showed that flexural behavior of column base-plate connection was substantially affected by the base-plate thickness, embedment length and the number of anchor bolts. On the other hand, the effect of rib plates on the increase of the flexural performance was not observed. The initial stiffness of the test specimens was about 15% of the flexural stiffness obtained by assuming that the support is fixed. As a result, even if the exposed column base-plate is designed in accordance with current design recommendations, in case that bond strength between concrete and the anchor bolts is not sufficient, the base-plate connection showed an unaccceptable load-displacement behavior.

Effects of Walking Speeds and Cognitive Task on Gait Variability (보행속도변화와 동시 인지과제가 보행 가변성에 미치는 영향)

  • Choi, Jin-Seung;Kang, Dong-Won;Tack, Gye-Rae
    • Korean Journal of Applied Biomechanics
    • /
    • v.18 no.2
    • /
    • pp.49-58
    • /
    • 2008
  • The purpose of this study was to identify effects of walking speed and a cognitive task during treadmill walking on gait variability. Experiments consisted of 5 different walking speeds(80%, 90%, 100%, 110% and 120% of preferred walking speed) with/without a cognitive task. 3D motion analysis system was used to measure subject's kinematic data. Temporal/spatial variables were selected for this study; stride time, stance time, swing time, step time, double support time, stride length, step length and step width. Two parameters were used to compare stride-to-stride variability with/without cognitive task. One is the coefficient of variance which is used to describe the amount of variability. The other is the detrended fluctuation analysis which is used to infer self-similarity from fluctuation of aspects. Results showed that cognitive task may influence stride-to-stride variability during treadmill walking. Further study is necessary to clarify this result.

Design of Thin Frequency Selective Surface Superstrates for Dual-Band Directivity Enhancement (이중 대역 지향성 증가용 박판 주파수 선택적 표면의 설계)

  • Lee Dong-Hyun;Lee Young-Ju;Yeo Jun-Ho;Mittra Raj;Park Wee-Sang
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.7 s.110
    • /
    • pp.648-658
    • /
    • 2006
  • We propose a thin frequency selective surface(FSS) superstrate etched on a substrate for dual-band directivity enhancement, and present a design method of the superstrate. In the proposed new design, two FSS arrays with the same periodicity, but with different alignments are placed above and below a thin dielectric layer to overcome the problem of conventional superstrates for dual band directivity enhancements. Based on the unit-cell simulation, several important parameters that characterize the thin FSS superstrate are investigated, and the procedure for designing such a superstrate is described. We compare the resonant frequencies and the qualify factors of the unit cell with those of three FSS antenna composites with different quality factors, and identify the quality factors which support similar directivity enhancement at the dual-band directivity enhancement. It was found that there is an optimum FSS array size of a superstrate to enhance the directivity most efficiently. Measured results for a fabricated superstrate show a good agreement with the simulated ones.

The Differences of EEG Coherence between Schizophrenia and Bipolar Disorder (정신분열병과 양극성장애에서 뇌파 동시성의 비교분석)

  • Kim, Yong-Kyu;Shin, Jae-Kong;Park, Chong-Won;Hong, Kyung Sue;Lee, Seung-Yeoun;Oh, Hong-Seok;Lee, Yong-Suk;Kwak, Yong-Tae;Chang, Jae Seung;Lee, Yu-Sang
    • Korean Journal of Biological Psychiatry
    • /
    • v.12 no.2
    • /
    • pp.123-135
    • /
    • 2005
  • Objectives:EEG coherence could imply the connectivity between two different areas of the brain, which is known to be important in the pathophysiology of bipolar I disorder(BPD I) and schizophrenia. The authors investigated EEG coherence in patients with BPD I and schizophrenia to examine the connectivity of the neural circuit. Methods:EEGs were recorded in 15 schizophrenia and 14 bipolar disorder patients, and 14 age-matched normal control subjects from 16 electrodes with linked-ear reference. Spectral parameters and coherence were calculated for the alpha bandwidth(8-13Hz) by a multi-channel autoregressive model using 20 artifact-free 2-seconds epochs and the differences were compared among three groups by two different statistical methods;F-test and Kruskal-Wallis test. Furthermore, when there were significant differences among three groups, Scheffe's multiple comparison tests were provided and Jonckheere-Terpstra tests for the ordered alternative were given. Results:In the intra-hemispheric comparison, left frontal coherence was increased in order of control, BPD I and schizophrenia. In the inter-hemispheric comparison, 1) inter-prefrontal coherence in BPD I was signifi- cantly higher than in normal controls, and 2) inter-prefrontal coherence in schizophrenia was significantly lower than in controls. Conclusion:These results suggest that 1) both schizophrenia and BPD I are diseases having the abnormality of neural circuit connectivity in both frontal and prefrontal lobes, and 2) the abnormality is more severe in schizophrenia than in BPD I. Furthermore, the data support that a common pathogenetic process may reside in both schizophrenia and BPD I.

  • PDF

Evaluation of Nondestructive Evaluation Size Measurement for Integrity Assessment of Axial Outside Diameter Stress Corrosion Cracking in Steam Generator Tubes (증기발생기 전열관 외면 축균열 건전성 평가를 위한 비파괴검사 크기 측정 평가)

  • Joo, Kyung-Mun;Hong, Jun-Hee
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.35 no.1
    • /
    • pp.61-67
    • /
    • 2015
  • Recently, the initiation of outside diameter stress corrosion cracking (ODSCC) at the tube support plate region of domestic steam generators (SG) with Alloy600 HTMA tubes has been increasing. As a result, SGs with Alloy600 HTMA tubes must be replaced early or are scheduled to be replaced prior to their designed lifetime. ODSCC is one of the biggest threats to the integrity of SG tubes. Therefore, the accurate evaluation of tube integrity to determine ODSCC is needed. Eddy current testing (ECT) is conducted periodically, and its results could be input as parameters for evaluating the integrity of SG tubes. The reliability of an ECT inspection system depends on the performance of the inspection technique and abilty of the analyst. The detection probability and ECT sizing error of degradation are considered to be the performance indices of a nondestructive evaluation (NDE) system. This paper introduces an optimized evaluation method for ECT, as well as the sizing error, including the analyst performance. This study was based on the results of a round robin program in which 10 inspection analysts from 5 different companies participated. The analysis of ECT sizing results was performed using a linear regression model relating the true defect size data to the measured ECT size data.

Development of a Design System for Multi-Stage Gear Drives (2nd Report: Development of a Generalized New Design Algorithm) (다단 치차장치 설계 시스템 개발에 관한 연구(제 2보: 일반화된 신설계 알고리즘의 개발))

  • Chong, Tae-Hyong;Bae, In-Ho;Park, Gyung-Jin
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.10
    • /
    • pp.192-199
    • /
    • 2000
  • The design of multi-stage gear drives is a time-consuming process because it includes more complicated problems, which are not considered in the design of single-stage gear drives. The designer has no determine the number of reduction stages and the gear ratios of each reduction stage. In addition, the design problems include not only dimensional design but also configuration design of gear drive elements. There is no definite rule or principle for these types of design problems. Thus the design practices largely depend on the sense and the experiences of the designer, and consequently result in undesirable design solution. A new and generalized design algorithm has been proposed to support the designer at the preliminary phase of the design of multi-stage gear drives. The proposed design algorithm automates the design process by integrating the dimensional design and the configuration design process. The algorithm consists of four steps. In the first step, the user determines the number of reduction stages. In the second step, gear ratios of every stage are chosen using the random search method. The values of the basic design parameters of a gear are chose in the third step by using the generate and test method. Then the values of the dimensions, such as pitch diameter, outer diameter and face width, are calculated for the configuration design in the next step. The strength and durability of each gear is guaranteed by the bending strength and the pitting resistance rating practices by using AGMA rating formulas. In the final step, the configuration design is carried out using simulated annealing algorithm. The positions of gears and shafts are determined to minimize the geometrical volume (size) of a gearbox while avoiding interferences between them. These steps are carried out iteratively until a desirable solution is acquired. The proposed design algorithm is applied to the preliminary design of four-stage gear drives in order to validate the availability. The design solution has considerably good results in both aspects of the dimensional and the configuration design.

  • PDF

Transport behavior of a surfactant tracer(CPC) with Langmuir type adsorption isotherm on NAPL-water interface in a homogeneous porous medium (NAPL-물 계면에서 Langmuir형 흡착특성을 보이는 계면추적자(CPC)의 다공성 균질매질내 유동특성)

  • 김헌기;문희수;이상훈
    • Journal of Soil and Groundwater Environment
    • /
    • v.6 no.2
    • /
    • pp.3-13
    • /
    • 2001
  • It has been known that nonlinear characteristics of sorption affect the transport behavior of water soluble pollutants in soils. However detailed experimental studies have not been performed to verify the effect of non-linearity of adsorption isotherm on transport of chemicals in porous media. In this research, the distortion of breakthrough curves of a cationic surfactant (cetylpyridinium chloride, CPC) in a engineered stainless steel column packed with glass beads were investigated. Glass beads with about 110 $\mu\textrm{m}$diameter coated with a thin n-decane film were used as the media providing the sorption surface for CPC. The CPC adsorption isotherm on the surface of n-decane from aqueous solution was a typical Langmuir type. The breakthrough curve of CPC using step Input showed a late breakthrough on the front side and early breakthrough on the back side accordance to the shape of the isotherm. The retardation factor of CPC was found to be a strong function of the input concentration, which also a manifestation of the non-linearity of the isotherm. The retardation factors for the CPC with step input agreed with those of pulse input that the maximum concentrations are controlled to be the same as the step input concentrations. This results support the validity of the unproven field practices of using hydrogeotracers with non-linear adsorption isotherms to determine the hydrogeological parameters, e.g., NAPL saturation, air-water or NAPL-water interfacial areas.

  • PDF

Efficacy of Pulsatile Hemodialyzer to Experimental Renal Failure in Dog (실험적으로 신부전을 유발시킨 개에서 박동형 혈액투석기의 효능)

  • Ji, Hye-Jung;Yun, Young-Min;Lee, Joo-Myoung;Kang, Tae-Young;Kim, Jae-Hoon;Cheong, Jong-Tae;Choi, Min-Joo;Min, Byung-Goo;Lee, Kyoung-Kap
    • Journal of Veterinary Clinics
    • /
    • v.23 no.3
    • /
    • pp.320-324
    • /
    • 2006
  • The purpose of the present study was to compare pulsatile type(Twin Pulse Life Support; TPLS) with rotary type hemodialyzer(AK95) in order to reduce the dialysis time and to improve dialysis effect. Three healthy dogs(about 30 kg BW) were used. Experimental renal failure was induced by the ligation of bilateral renal artery. A pair of catheters were implanted in jugular vein for dialysis. Daily investigated parameters included clinical signs such as vomiting, fecal appearance and activity, and also laboratory data such as PCV, TP, BUN and creatinine. Hemodialysis was started above 90 mg/100 ml BUN level and, laboratory data were measured every an hour for 4 hours. Heparin was administered 300 IU/Kg before dialysis and 150 IU/Kg via IV route every 90 minutes during dialysis. Clinical signs after induction renal failure were shown severe vomiting, anorexia, diarrhea, mucous feces, ataxia, dilated pupil and episcleral hyperemia. The average of BUN value decreased hourly $99{\pm}12.1,\;84{\pm}12.2,\;72{\pm}8.0,\;58{\pm}7.1,\;48{\pm}5.2,\;and\;39{\pm}3.2mg/100ml$ by hemodialysis. The average of creatinine value decreased $7.8{\pm}0.61,\;6.4{\pm}0.40,\;5.3{\pm}0.42,\;4.5{\pm}0.23,\;4.0{\pm}0.41,\;and\;3.4{\pm}0.42mg/100ml$ according to hemodialysis an hour. There are not significantly differences BUN, creatinine, PCV and TP values between pulsatile and rotary type hemodialysis. These results suggested that effects of hemodialysis with Pulsatile type(TPLS) are not significantly difference as compared with hemodialysis of rotary type(AK95). Further research is needed in order to estimate the influence of cardiovascular and pulmonary system in hemodialysis of pulsatile type.

Study on the Associations of Dietary Variety and Nutrition Intake Level by the Number of Survey Days (식이조사 일수에 따른 식사 다양성과 영양소 섭취 수준과의 관계연구)

  • Lee Ji Eun;Ahn Younjhin;Kimm Kuchan;Park Chan
    • Journal of Nutrition and Health
    • /
    • v.37 no.10
    • /
    • pp.908-916
    • /
    • 2004
  • Due to the common dietary practice of preparing foods in various ways using the same food item, in addition to rather a large number of food items that average Koreans consume, it is difficult to accurately assess the nutritional adequacy. In an effort to identify a reliable means of assessing the nutritional adequacy of Korean adults, we analyzed the association between the scores of dietary diversity (DDS) and dietary variety (DVS), and the quality of nutrient intake as assessed by Nutrient Adequacy Ratio (NAR) and Mean Adequacy Ratio (MAR). A three day-dietary record was obtained from each of 324 inhabitants, aged 40 to 69 years (mean :t SD,52.4 $\pm$ 8.7), of a rural area (Ansung) and a mid-sized city (Ansan) of Korea. These individuals were randomly selected among the participants of the Korean Health and Genome Study. The number of consumed foods and food groups were assesses by DDS (scored 1 to 5) and DVS (ranked 30 $\leq$,31 - 40, 41 - 50, 51 - 60, and 60 <) over three-day period, respectively. As DDS/DVS increased, mean daily food intakes tended to increase, and NARIMAR was improved. Thus, DDS and DVS were significantly correlated with the quality of nutrient intake. Over 95% of the subjects scored less than 2 in DDS for the first one-day period, whilst over 62% recorded 4 during the full three-day period (p < .0001). The mean number of consumed food items increased from 24.9 to 44.4 as a function of days of the record period (p < .0001). We also analyzed the association of DDS and DVS with MAR, using regression analysis, controlling age and sex as covariates. For DDS, the adjusted coefficient determination (adj $R^2$) values were 8.7%,15.8%,23.3% of MAR, also increasing as a function of the record duration, whereas they were 27.3%, 33.3%, 37.6% for DVS, respectively, demonstrating that NAR/MAR has a better correlation with DVS than DDS. Our data show that DDS, and DVS in particular, are useful parameters for evaluating nutrient intake in the Korean population. Our data also support that one day-dietary records are by no means adequate for accurately describing a wide variety of food choices offered for average Koreans, and that dietary assessment at least for 3 days or longer should be obtained for a reliable evaluation of dietary quality using DDS or DVS.

BER Performance of DS/CDMA-BPSK Systemin 3-State Land Mobile Satellite fading Channel (3-상태 육상이동위성 페이딩 채널에서 DS/CDMA-BPSK 시스템의 오율 성능)

  • Cho, Sung-Eon;Cho, Kyung-Ryong;Yeo, Hyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.3 no.4
    • /
    • pp.795-804
    • /
    • 1999
  • The increasing number of users of mobile communication systems and the corresponding need for increased system capacity require the use of a modulation scheme which is both power and spectrally efficient. In this paper, we numerically calculate the BER performance of DS/CDMA-BPSK system in different fading channel (Rayleigh, Rician, Shadow Rician). Also, we calculate BER performance and the channel capacity of DS/CDMA-BPSK system which is constant or nearly constant envelopes in 3-state fading channel model. The Shadow Rician fading model described in this paper apply the parameters of the Canadian Mobile Satellite (MSAT). And we assume that the 3-state fading channel model is consist of Rayleigh fading state, Rician fading state, and shadow Rician fading state. This model can be used as a basis for the simulation of the land mobile satellite channel. The dynamic 3-state fading channel model is considered corresponding to different environments and the transitions between these environments. From the numerically calculate results, the DS/CDMA-BPSK system with MUI-20, PG-511 can not achieve the BER performance ($P_b\leq10^{-5}$). And the channel capacity did not meet the system requirement. Also, we know that the BER performance is depend m the occupancy probability of radio channel and the degree of shadow. From the results, we how that during shadowed time intervals it is necessary to use some form of error control coding and receiver diversity in order to support reliable data communication.

  • PDF