• 제목/요약/키워드: supplying water

검색결과 317건 처리시간 0.028초

수열에너지 입지 선정을 위한 계층화분석법의 적용 (Application of analytic hierarchy process technique for selecting a hydrothermal energy site)

  • 안주현;박수완;오창현
    • 상하수도학회지
    • /
    • 제38권2호
    • /
    • pp.69-81
    • /
    • 2024
  • In this study, an evaluation system that can be used to evaluate the feasibility of developing and supplying hydrothermal energy for the operation of large-scale complex facilities was developed. To this end, this study derived factors to be considered when selecting a location for the use of hydrothermal energy using raw water from multi-purpose dams and regional water supply systems through literature survey and expert interviews. The evaluation indicators derived from this study are divided into four sectors: hydrothermal energy utilization factors, location factors, planning factors, and disaster safety factors, and are composed of 10 mid-level indicators and 34 detailed planning indicators. The relative importance of all factors was derived using the Analytic Hierarchy Process (AHP) technique, and the developed evaluation indicators and relative importance were applied to four multi-purpose dam regions in the country. As a result, it was found that in the development and use of hydrothermal energy utilizing regional raw water supply line the urban planning conditions of the supply site can have a greater impact on the location selection results than the hydrothermal energy development itself. Due to the characteristics of the evaluation indicators developed in this study and their nature as comprehensive indicators, it is believed that the results should be applied to determine the overall adequacy of site selection in the early stages of hydrothermal energy development. In the future, it is believed that it will be necessary to analyze the problems in supplying and operating hydrothermal energy using raw water from multi-purpose dams and regional water resources. Based on the analysis the evaluation system developed in this study is expected to be improved and supplemented.

SOB(Sulfur Oxidizing Bacteria) Media가 정화조의 수중황화수소 제거에 미치는 영향에 관한 연구 (A study on the Effect of SOB(Sulfur-Oxidizing Bacteria) Media on the Removal of Hydrogen Sulfide in Water of Septic Tank)

  • 송호면;조정일;김택수;권수철;유형식
    • 상하수도학회지
    • /
    • 제27권1호
    • /
    • pp.59-67
    • /
    • 2013
  • The odor occurring in the sewage system induces the displeasure, the disgust such as the headache, the vomit, etc. and increases the spiritual stress and disturbs the pleasant life of residents. These odors occur mainly in the area of combined sewage system treatment, being created in the personal sewage treatment plant such as septic tank and are incoming to sewage pipes and emitted to the outside through the manhole and the receiver, etc.; and this causes odors to the people. The Hydrogen Sulfide, the Methyl Mercaptan, the Ammonia, etc. are materials causing the odor, the more serious issue of odor is occurring since the septic tank of degradation process is being applied. The primary cause of odor is the decomposition of human feces in the septic tanks and sewage disposal facilities. The purpose of this study is reduction of hydrogen sulfide using air supplying and SOB(Sulfur-Oxidizing Bacteria). As a result of this study of the air supply system and the SOB media equipment by air supply, in case the air is injected to SOB media compared to the injection of air only, the removal efficiency the hydrogen sulfide was average 3.4 times higher.

급기가 되는 이중바닥 구조체의 열 성능 평가 (Estimation of the thermal performance on the double slab floor with supplying air)

  • 차광석;박명식;이대우;남우동
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.866-871
    • /
    • 2006
  • Recently according to the fashion of well-being, the case study of under floor heating system type for residential space is increasing. Specially double slab floor system can make several roles as reducing the acoustic noises and also supplying fresh air through the gap. So in present study floor heating performance was examined with various location of the space in the case of floor supply air and ceiling supply air. In both cases return air went out through ceiling opening. As one of the result is that when using the heat pipe type floor heating system the temperature difference between supply and return water was $15.2^{\circ}C$, but in case of commercial type floor heating system the temperature difference was $5.3^{\circ}C$ when the supply water temperature was $50^{\circ}C$.

  • PDF

울산시 도심하천의 자연형 하천 조성에 따른 식생 변화 (Change of Vegetation Based on Nature-friendly River of Urban Streams in Ulsan)

  • 강호선;조홍제
    • 한국수자원학회논문집
    • /
    • 제47권7호
    • /
    • pp.657-670
    • /
    • 2014
  • 수질개선과 하천개수를 통한 자연형하천 조성으로 주민들의 친수공간으로 이용되고 있는 울산시의 5개 도시하천에 대해 식생을 조사하였다. 하천의 기하학적 특성이나 수질 및 제내지 및 제외지 등 주변여건과 식생의 활성화 등과의 상관관계를 조사하였다. 각 하천의 자연형하천 조성시기가 다르고 일천한 관계로 뚜렷한 정량적 상관관계를 얻을 수는 없었으나, 식생의 활성화 정도가 현하천의 수질과 제내지 및 제외지 등 주변 여건에 의한 차이점은 어느 정도 확인할 수 있었다. 자연상태에 가까운 척과천은 식생종류가 다양하였고, 수질과 주변 여건이 좋은 무거천과 명정천은 인위적 유지용수 공급과 개수공사에 의한 인공물이 많지만 식생의 활성화 정도가 좋았다. 반면에 수질이 나쁘거나 하폭과 둔치가 좁은 데도 무리하게 산책로 등을 조성하였던 여천천과 약사천은 식생의 종류가 다양하지 못하였고 활성화도 낮은 것으로 나타났다.

아파트단지의 급수량 및 오수발생량에 대한 조사 연구 (A Study on the Water Supplies and Sewage Amount in the Apartment Complexes)

  • 윤여진;최명수;방기웅
    • 한국수자원학회논문집
    • /
    • 제31권2호
    • /
    • pp.155-165
    • /
    • 1998
  • 생활수준 향상과 식생활 변화로 인하여 생활용수 소비량이 증가함에 따라 일상생활에서 배출되는 오수의 양도 증가할 것으로 예측된다. 아파트 단지내 오수정화시설 및 하수처리장의 설계를 위해서는 먼저 인구에 근거한 오수량의 발생원단위를 알아야 한다. 이러한 자료는 하수처리의 운전이나 수질관리 계획 수립을 위해서도 꼭 필요한 것이다. 따라서 본 연구에서는 주택공사의 123개 관리소에 2년간의 급수량을 취합하여 거주인구에 따른 급수량을 분석하였고 그 중에 수도권 1개 단지와 지방권 1개 단지를 선정하여 시간별, 일별, 요일별, 계절별의 오수유입량을 직접 실측함으로써 실제 급수량과 비교를 통하여 오수유입 총량 및 거주인구에 따른 원단위를 계산하였다.

  • PDF

선택취수 수심에 따른 취수탑 유입유동 특성 (Inflow Patterns Around a Water Intake Tower for Selective Withdrawal Depth)

  • 조용;김용열
    • 한국유체기계학회 논문집
    • /
    • 제13권6호
    • /
    • pp.63-70
    • /
    • 2010
  • Shallow water withdrawal systems have been replaced with a selected withdrawal system to keep stable raw water quality in spite of occurrence of algae and muddy inflow. Before reconstruction of the water intake tower in Yongdam reservoir supplying water to Gosan water treatment facility, we have predicted flow patterns of inflowing water into the water intake tower for various withdrawal conditions. It has been predicted that the water in the withdrawal layer is significantly inflowed from the front with fast velocity into the water intake tower irrespective of withdrawal depth, while the water away from the withdrawal layer is withdrawed a little from the side with slow velocity.

호우발생시 저수지 유입 부유사농도의 변화특성 연구 (A Study on the Variation of Suspended Sediment Concentration in the Reservoir due to a Rainstorm)

  • 장수형;박무종;윤용남
    • 한국수자원학회논문집
    • /
    • 제37권1호
    • /
    • pp.43-54
    • /
    • 2004
  • 본 연구의 목적은 호우시에 저수지로 유입되는 토사유출량을 산정하고 저수지내 부유사 농도의 변화특성을 분석하여 저수지의 정량적 관리를 위한 자료를 제안하기 위한 것이다. 연구는 탐진댐에 적용되었으며 강우유출관계는 Huff의 강우분포와 Clark의 유역추적법을 사용하였으며, 저수지 추적은 Puls방법을 이용하였다. 토사유출량의 산정은 범양토양손실공식을 분포형 개념을 이용 단일호우에 대해 적용하여, 적정 빈도에 대해서도 적용가능하도록 하였다. 또한, 저수지내에서의 부유사 농도는 2차원 수리모형인 RMA-4를 이용하였다. 연구 수행결과 호우발생시 저수지에서의 취수가능기간에 대한 계산이 가능하며, 이를 이용하여 재현기간 및 강우량에 따른 여러 측면에서 용수공급에 따른 일정 수질 유지를 위한 자료를 제시하였다. 이는 강우시 저수지 수질관리를 위한 기초자료로 사용 가능하다.

볼록한 바닥면 설계를 통한 소방용수 저장탱크의 수직 벽면에서의 동수력 저감 연구 (Reduction of Hydrodynamic Force Acting on the Vertical Wall of a Portable Water Storage Tank by Convex bottom Design)

  • 소수현;박진수;성홍근;장택수
    • 한국화재소방학회논문지
    • /
    • 제32권6호
    • /
    • pp.69-73
    • /
    • 2018
  • 본 연구에서는 볼록한 바닥면을 가진 이동형 소방용수 저장탱크의 수직 벽면에 작용하는 동수력을 계산하고 그 결과를 바탕으로 볼록한 바닥면 설계를 통한 동수력의 감소 효과를 확인하고자 하였다. 수치 모의 실험하기 위해 바닥의 형태를 볼록하게 한 수치 해석 영역을 구성하였으며, 특정 위치와 높이에 용수 공급 노즐을 위치시켜 용수를 낙하시켰다. 용수 낙하에 의한 자유 수면의 출렁임과 수직 벽면에서의 유체 벽 오름을 선형 Peregrine 방정식을 이용하여 수치 모사하고 동수력을 계산하였으며, 그 결과를 오목한 바닥면 및 동일한 해석 조건에서 얻은 동수력과 서로 비교 분석하였다. 결과적으로 오목한 바닥면 설계에 비해 볼록한 바닥면 설계를 통해 수직 벽면에서의 동수력이 더 작아짐을 확인할 수 있었다. 본 연구 결과는 이동형 소방용수 저장탱크의 안정적인 구조 설계 및 운용에 기여할 수 있을 것으로 사료된다.

25BAR급 바이오가스 고압 압축공급시스템 상세설계 (Detailed Design for 25bar-class Biogas Compression Supplying System)

  • 허광범;박정극;윤은영;이정빈
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 춘계학술대회 초록집
    • /
    • pp.173.1-173.1
    • /
    • 2011
  • The high fuel flexibility of gas turbine power system has boosted their use in a wide variety of applications. Recently, the demand for biogas generated from the digestion of organic wastes and sewage waste water as a fuel for gas turbines has increased. We investigated the performance of high pressure biogas compression system and operating conditions for supplying biogas. The total flow per minute of biogas from food waste water digestion tank is $54Nm^3$. The main type of biogas compression system is the reciprocating system and screw type system. The target of biogas mechanical data is the as belows; inlet pressure 0.045bar, supplying biogas temperature is $30{\sim}60^{\circ}C$, and final pressure is above the 25 bar. Also, inlet conditions of biogas consist of CH4 48.5%~83%, $H_2S$ Max. 500ppm, $NH_3$ Max. 1,500ppm and Siloxane 2.7~4.6ppm. The boosting Blower system raises a pressure from 0.045bar to 1bar before main compressor. The main system lay out of reciprocating consisits of compressor driver, filter, cooling system, blowdown vessel, control system and ESD(Emergency Shut Down) system. And an enclosure package needs to be installed for reducing noise up to 75dB. The system driver is the electronic motor of explosion proof type. Forthe compressor system reliable operation, the cleaning system something like particulate filter needs to be set up in the inlet of compressor and Coalescing Filter in the outlet of compressor. Particulate Filter has to be removed above $10{\mu}m$ size of the particles in biogas. The coalescing filter(Micofine Borosilicate Glass Fibers Filter treated phenol acid) also removes moisture and oil of above $0.3{\mu}m$ to be involved in high pressure biogas up to 90%~98%.

  • PDF

생활 오배수를 이용한 중수처리 공급장치의 기술성 고찰 (Technical Considerations of Recycling Water Treatment/Supply Apparatus using Living Waste Water)

  • 조정식;이희완;김홍민
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.493-498
    • /
    • 2008
  • The several water resources are showed recently the various pollution types due to the industrialization and the disarranged district development. The living waste water, plant waste water and so are contaminated continuously and the recycling water is concerned highly to save the cost and to improve the environment as the general people. The dust and the heavy metal in the air and the acid rain are contaminating the river water and the underground water. The clean environment is on the rise to the general people and is to be the social problems. There is going to complement and repair the water supplying and fire extinguishing pipeline to save the construction cost and improve the environment in the construction facilities parts. Therefore, in this paper the recycling water treatment/supply apparatus using the living waste water is considerated technically and is raised on the practical uses.

  • PDF