• Title/Summary/Keyword: supply pipe

검색결과 390건 처리시간 0.03초

Limit Loads for Circular Wall-Thinned Feeder Pipes Considering Bend Angle (굽힘각도를 고려한 원형 감육이 발생한 중수로 피더관의 한계하중)

  • Bae, Kyung-Dong;Je, Jin-Ho;Kim, Jong-Sung;Kim, Yun-Jae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • 제36권3호
    • /
    • pp.313-318
    • /
    • 2012
  • In CANDU, feeder pipes supply heavy water to pressure tube and steam generator. Under service conditions, Flow-Accelerated Corrosion (FAC) produces local wall-thinning in the feeder pipes. The wall-thinning in these pipes affects the integrity of the piping system, as verified in previous research. This paper provides limit loads for wallthinned feeder pipes with $45^{\circ}$ and $60^{\circ}$ bend angles, and proposes an equation that predicts the limit loads for wallthinned feeder pipes with arbitrary bend angles. On the basis of finite element limit analyses, limit loads are obtained for wall-thinned feeder pipes under in-plane bending and internal pressure. There are two cases of in-plane bending: the in-plane closing direction and the in-plane opening direction. The material is considered the effect of the large deformation, so an elastic-perfectly-plastic material is assumed in the calculations.

Implementation of The Fluid Circulation Blood Pressure Simulator (유체 순환 혈압 시뮬레이터의 구현)

  • Kim, C.H.;Lee, K.W.;Nam, K.G.;Jeon, G.R.
    • Journal of Biomedical Engineering Research
    • /
    • 제28권6호
    • /
    • pp.768-776
    • /
    • 2007
  • A new type of the fluid circulation blood pressure simulator was proposed to enhance the blood pressure simulator used for the development and evaluation of automatic sphygmomanometers. Various pressure waveform of fluid flowing in the pipe was reproduced by operating the proportional control valve after applying a pressure on the fluid in pressurized oil tank. After that, appropriate fluid was supplied by operating the proportional control valve, which enabled to reproduce various pressure wave of the fluid flowing in the tube. To accomplish this work, the mathematical model was carefully reviewed in cooperating with the proposed simulator. After modeling the driving signal as input signal and the pressure in internal tube as output signal, the simulation on system parameters such as internal volume, cross-section of orifice and supply pressure, which are sensitive to dynamic characteristic of system, was accomplished. System parameters affecting the dynamic characteristic were analyzed in the frequency bandwidth and also reflected to the design of the plant. The performance evaluator of fluid dynamic characteristic using proportional control signal was fabricated on the basis of obtained simulation result. An experimental apparatus was set-up and measurements on the dynamic characteristic, nonlinearity, and rising and falling response was carried out to verify the characteristic of the fluid dynamic model. Controller was designed and thereafter, simulation was performed to control the output signal with respect to the reference input in the fluid dynamic model using the proposed proportional control valve. Hybrid controller combined with an proportional controller and feed-forward controller was fabricated after applying a disturbance observer to the control plant. Comparison of the simulations between the conventional proportional controller and the proposed hybrid simulator indicated that even though the former showed good control performance.

Performance test and factor analysis on the performance of shutoff units with the research reactor (연구용 원자로의 정지봉 장치 성능에 미치는 인자 분석과 성능 시험)

  • Kim, Kyoung-Rean;Kim, Seoug-Beom;Ko, Jae-Myoung;Moon, Gyoon-Young;Park, Jong-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • 제10권2호
    • /
    • pp.41-45
    • /
    • 2007
  • The shutoff unit was designed to provide rapid insertion of neutron absorbing material into the reactor core to shutdown the reactor quickly and also to withdraw the absorber slowly to avoid a log-rate trip. Four shutoff units were installed on the HANARO reactor but the half-core test facility was equipped with one shutoff unit. The reactor trip or shutdown is accomplished by four shutoff units by insertion of the shutoff rods. The shutoff rod(SOR) is actuated by a directly linked hydraulic cylinder on the reactor chimney, which is pressurized by a hydraulic pump. The rod is released to drop by gravity, when triplicate solenoid valves are de-energized to vent the cylinder. The hydraulic pump, pipe and air supply system are provided to be similar with the HANARO reactor. The shutoff rod drops for 647mm stroke within 1.13 seconds to shut down the reactor and it is slowly inserted to the full down position, 700mm, with a damping. We have conducted the drop test of the shutoff rod in order to show the performance and the structural integrity of operating system of the shutoff unit. The present paper deals with the 647mm drop time and the withdrawal time according to variation of the pool water temperature, the water level and the core flow.

Numerical Study of Land/Channel Flow-Field Optimization in Polymer Electrolyte Fuel Cells (PEFCs) (II) - The Effects of Land/Channel Flow-Field on Temperature and Liquid Saturation Distributions - (고분자전해질형연료전지의 가스 채널 최적화를 위한 수치적 연구 (II) - 가스 채널 치수가 온도와 액체포화 분포에 미치는 영향성 -)

  • Ju, Hyun-Chul;Nam, Jin-Moo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • 제33권9호
    • /
    • pp.688-698
    • /
    • 2009
  • Using the multi-dimensional, multi-phase, nonisothermal Polymer Electrolyte Fuel Cell (PEFC) model presented in Part I, the effects of land/channel flow-field on temperature and liquid saturation distributions inside PEFCs are investigated in Part II. The focus is placed on exploring the coupled water transport and heat transfer phenomena within the nonisothermal and two-phase zone existing in the diffusion media (DM) of PEFCs. Numerical simulations are performed varying the land and channel widths and simulation results reveal that the water profile and temperature rise inside PEFCs are considerably altered by changing the land and channel widths, which indicates that oxygen supply and heat removal from the channel to the land regions and liquid water removal from the land toward the gas channels are key factors in determining the water and temperature distributions inside PEFCs. In addition, the adverse liquid saturation gradient along the thru-plane direction is predicted near the land regions by the numerical model, which is due to the vapor-phase diffusion driven by the temperature gradient in the nonisothermal two-phase DM where water evaporates at the hotter catalyst layer, diffuses as a vapor form and then condenses on the cooler land region. Therefore, the vapor phase diffusion exacerbates DM flooding near the land region, while it alleviates DM flooding near the gas channel.

Performance Improvement of Cross-Flow type Small Hydro Turbine by Air Layer Effect (소수력발전용 횡류수차의 공기층효과에 의한 성능향상)

  • Choi, Young-Do;An, Young-Joon;Shin, Byeong-Rog;Lee, Dong-Yeup;Lee, Young-Ho
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1070_1071
    • /
    • 2009
  • Recently, small hydropower attracts attention because of its clean, renewable and abundant energy resources to develop. Therefore, a cross-flow hydraulic turbine is proposed for small hydropower development in this study. The turbine‘s simple structure and high possibility of applying to the sites of relatively low effective head and large flow rate can be advantages for the introduction of the small hydropower development. The purpose of this study is not only to investigate the effects of air layer in the turbine chamber on the performance and internal flow of the cross-flow turbine, but also to suggest a newly developed air supply method. CFD analysis for the performance and internal flow of the turbine is conducted by an unsteady state calculation using a two-phase flow model in order to embody the air layer effect on the turbine performance effectively. The result shows that air layer effect on the performance of the turbine is considerable. The air layer located in the turbine runner passage plays the role of preventing a shock loss in the runner axis and suppressing a recirculation flow in the runner. The location of air suction hole on the chamber wall is very important factor for the performance improvement. Moreover, the ratio between air from suction pipe and water from turbine inlet is also significant factor of the turbine performance.

  • PDF

Characteristics of Reducing the Water-drainage Noise of Toilet-bowl According to the Composition of Water Drainage Piping Materials of the Bathrooms of Apartment Housing (공동주택 욕실 배수배관 자재 구성에 따른 양변기 배수소음 저감 특성)

  • Jeong, A-Yeong;Kim, Kyoung-woo;Shin, Hye-kyung;Yang, Kwan-seop
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • 제27권1호
    • /
    • pp.114-120
    • /
    • 2017
  • Water supply and drainage noise in the bathroom is recognized as one of the main noises, along with the floor-impact sounds, in apartment housings. Recently, to solve such noise issues, a new construction method of installing the piping on the slab has been adopted. rather than the traditional method of penetrating the piping through the slab between the upper and the lower bathrooms. However, this new method has limitations due to high costs and constructional difficulties. Therefore, this study was conducted to develop noise reducing piping and elbows, where the noise can be reduced simply by replacing the existing pipings. The noise level was measured in a laboratory by installing the horizontal drainage piping (three types) and the elbows (three types) developed in this study. The results showed that the horizontal pipings reduced the noise level in LAmax by 0.3 dB(A)~1.0 dB(A), as compared to the existing pipings (VG2), indicating an insignificant noise reduction effect. The elbow reduced the noise level in LAmax by 5.5 dB(A) ~ 11.5 dB(A), as compared to the existing elbow (DRF elbow), with the result of reducing the noise level at all frequencies evenly. Consequently, it was shown that using the elbows is more effective in reducing the water-drainage noise from the toilet than using the horizontal pipings.

A Safety Improvement for the Design Change of Westinghouse 2 Loop Auxiliary Feedwater System (웨스팅하우스형 원전의 보조급수계통 설계변경 영향 평가)

  • Na, Jang Hwan;Bae, Yeon Kyoung;Lee, Eun Chan
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • 제9권1호
    • /
    • pp.15-19
    • /
    • 2013
  • The auxiliary feedwater is an important to remove the heat from the reactor core when the main feedwater system is unavailable. In most initiating events in Probabilistic Safety Assessment(PSA), the operaton of this system is required to mitigate the accidents. For one of domestic nuclear power plants, a design change of a turbine-driven auxiliary feedwater pump(TD-AFWP), pipe, and valves in the auxiliary system is implemented due to the aging related deterioration by long time operation. This change includes the replacement of the TD-AFWP, the relocation of some valves for improving the system availability, a new cross-tie line, and the installation of manual valves for maintenance. The design modification affects the PSA because the system is critical to mitigate the accidents. In this paper, the safety effect of the change of the auxiliary feedwater system is assessed with regard to the PSA view point. The results demonstrate that this change can supply the auxiliary feedwater from the TD-AFWP in the accident with the motor-driven auxiliary feedwater pump(MD-AFWP) unavailable due to test or maintenance. In addition, the change of MOV's normal position from "close" to "open" can deliver the water to steam generator in the loss of offsite power(LOOP) event. Therefore, it is confirmed that the design change of the auxiliary feedwater system reduces the total core damage frequency(CDF).

A Study on Quantitative Risk Presentation of LNG Station (LNG충전시설의 위험도 표현에 관한 연구)

  • Ko, Jae-Wook;Yoo, Jin-Hwan;Kim, Bum-Su;Lee, Heon-Seok;Kim, Min-Seop
    • Journal of the Korean Institute of Gas
    • /
    • 제13권1호
    • /
    • pp.61-67
    • /
    • 2009
  • There are lots of energy facilities using gas(storage facility, compressed gas pipe, station, tank lorry) on the domestic. These major gas facilities cause major accidents associated with fire, explosion, toxic and etc. With the increased interest in reducing air pollution, supply of natural gas for gas vehicles is increasing. Thus, the number of establishments of LNG (Liquefied Natural Gas) and CNG(Compressed Natural Gas) stations is increasing as well. However, due to major gas accidents such as the fire and explosion accident of a Buchen LPG (Liquefied Petroleum Gas) station, it is difficult to establish a new station. In this research, we present quantitative risk assessment for LCNG;LNG multi-station and compare it result against individual risk criteria of HSE.

  • PDF

Measurement and Analysis of Dust Concentration in a Fattening Pig House Considering Respiratory Welfare of Pig Farmers (비육돈사 작업 종사자의 호흡기 관련 공기 중 분진 농도 측정 및 분석)

  • Kwon, Kyeong-Seok;Lee, In-Bok;Hwang, Hyun-Seob;Ha, Tae-Hwan;Ha, Jung-Soo;Park, Se-Jun;Jo, Ye-Seul
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • 제55권5호
    • /
    • pp.25-35
    • /
    • 2013
  • In swine house, dust generation comes from various sources and is known to be harmful both for the animals and the farmers because the dust contains biological and gaseous matters. When farmers are constantly exposed to the dusts, they can suffer chronic or acute respiratory symptoms and have high probability of manifesting various diseases. To address this problem, understanding of the mechanism of dust generation is very important. In this paper, the dust concentration of inhalable, respirable, TSP and $PM_{10}$ were monitored and analyzed according to the pig-activity level, ventilation quantity and feeding method in fattening pig house. From the measured results, in case of the concentration of TSP, an inverse-linear relation with ventilation rate ($R^2=0.88$) and linear relation with the installation height of feed supply pipe ($R^2=0.73$) were determined. However in case of the concentration of $PM_{10}$, no particular relationship with the variables was observed. Using the concentration of inhalable and respirable dust based on the pig-activity level, multi-variate regression analysis was conducted and results have shown that the movement of pigs can contribute to the dust generation (p<0.05, $R^2=0.71$, 0.61). The relationship determined between dust generation and environmental variables investigated in this study is very significant and useful in conducting dust-reduction researches.

The Component Analysis of Foreign Substance Occurred in Water Distribution Networks (상수관망에서 발생하는 이물질의 성분분석)

  • Choi, Min-Ah;Kim, Do-Hwan;Bae, Chul-Ho;Lee, Doojin;Choi, Doo Yong
    • Journal of Korean Society of Environmental Engineers
    • /
    • 제36권9호
    • /
    • pp.614-623
    • /
    • 2014
  • Customers water quality complaints by foreign substance in local water service can be able to call the main cause bring the distrust for tap water and inhibiting the rate of drinking water. In this study, foreign substances were collected in the target region. Foreign objects were subjected to qualitative and quantitative analysis of compounds and elements components to reveal the cause of detection. Also, resolve the complaints by foreign substance and improve the reliability for tap water providing high quality water supply scheme. Collected substances at the water quality complaint area were included in inorganic compounds due to internal corrosion and aging pipeline, as well as organic compounds containing a large amount of carbon (C) and oxygen (O) component. To decide and reduce for foreign substance, objective assessment of pipe condition in target area was required.