Study of Drinking water pipeline Corrosion Mechanism by using Scale Analysis (부식 생성물 분석법을 이용한 상수도 금속관의 부식거동에 관한 연구)

  • 황상용;송호봉
    • Journal of environmental and Sanitary engineering
    • /
    • v.17 no.1
    • /
    • pp.57-62
    • /
    • 2002
  • Carbon cast iron and Zinc coated steel were the most widely used portable water of supply and distribution Pipeline system. The leaching of red water in portable water could produce sericus environmental sanitary problems. Due to the red water was the most alternative to inner scale of metal pipeline. So this study was conducted the impact of red water on scale products, and was evaluated by the corrosive metal contaminants of 20 fears over. Surface tests, metal surface composition measurements of samples XRF, XRD, and SEM(EDS), analysis were used to investigate the corrosion characteristies of carbon cast iron and Zinc coated steel. As the contaminants of Fe increased the red water of carbon castiron pipe increased due to the scale products amount of $Fe_2O_3$ (Hemite).

A study on the device introduction of wastewater reclamation system a treated sewage (하수처리수를 활용한 중수도의 도입방안 연구)

  • Park, Rho-Sam;Park, Sang-Hyun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.2 no.2
    • /
    • pp.23-33
    • /
    • 1999
  • After studying several methods of the application a device of a treated sewage in anticipation of the future shortage of the duty of water, we could have some conclusion as the following : Advanced treatment systems arc essential prerequisites in reusing a treated sewage. And in a short term, the application of reusing a treated sewage should go first to new building areas near the sewage but for the long run, it should cover the whole area of Taegu, it is desirable that the pipe line networks which include dual water systems as well as water supply should be spread throughout the whole city. The city authorities have to make every effort to step up publicity activities on this plan to all the citizens and building owners to steadily carry out this project and encourage private constructors to participate with the help of SOC. And for the long run, it is desirable that the application of reusing a treated sewage should be obligatory.

  • PDF

Performance Analysis of a Panel Type Latent Heat Storage Equipment for Solar Thermal Storage (태양열저장(太陽熱貯藏)을 위한 평판형잠열축열장치(平板形潛熱蓄熱裝置)의 성능분석(性能分析))

  • Kim, Y.B.;Ju, E.S.;Yun, Y.D.;La, W.J.
    • Journal of Biosystems Engineering
    • /
    • v.16 no.3
    • /
    • pp.290-297
    • /
    • 1991
  • For the efficient utilization of the solar thermal energy to overcome the time gap between to supply and demand, an efficient heat storage technique, especially high density-latent-heat storage system, is necessary. In this study, the performance of a panel type latent heat storage equipment during heat discharging process was analyzed theoretically and experimentally. In order to find out the performance of the system, computer simulation programs were developed by finite difference method. The governing equations were constructed by two dimensional heat conduction model with moving boundary. The results of the experimental and the theoretical analysis were reasonably well agreed. The efficiencies of the double pipe type and the panel type latent heat storage equipment were compared.

  • PDF

A STUDY ON DEGREASING DETERGENT AND METHOD FOR THE IPP TEST FACILITY

  • Kim Yong-Wook;Lee Jung-Ho;Kang Sun-Il;Kim Sang-Heon;Oh Seung-Hyub
    • Bulletin of the Korean Space Science Society
    • /
    • 2004.10b
    • /
    • pp.262-265
    • /
    • 2004
  • As a cryogen, LOx is a light blue, odorless, transparent liquid. Also it is not shock sensitive and does not decompose. However, it is a strong oxidizer and will vigorously support combustion. Therefore all harmful contaminants (such as grease, oil, fingerprint and organic materials) that could cause malfunctions, fires, or explosions in a oxygen environments must be completely removed prior to the introduction of oxygen. Especially, grease ingredient located inside of the LOx supply line, pipe and PHS (Pneumo-Hydraulic System) part can make drastic chemical reaction with oxygen. Therefore, to protect rapid reaction such as explosion, grease ingredient must be surely eliminated by a regular and irregular degreasing. Study on the availability, effectiveness and selection of degreasing detergents and method is described in this paper, and it will be useful for the construction and management of IPP test facility.

  • PDF

Conceptual Design of Penumatic System Routing for Liquid Rocket Engine (액체로켓엔진의 공압류 라우팅 개념 설계)

  • Kim, Okkoo;Park, Soonyoung;Jung, Eunhwan
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.1112-1114
    • /
    • 2017
  • The liquid rocket engine determines the routing of the component placement and layout by adapted the cycle method, the hardware configuration, the gimbal type on the functional implementation, and so on. In this paper, the conceptual routing of major pneumatic lines such as helium (He) supply pneumatic line for driving, many purge pneumatic line and main ignition line based on the main components installed in the liquid rocket engine was performed.

  • PDF

The System Improvement of the Individual Sewage Treatment System (개인하수처리시설의 제도개선에 관한 연구)

  • Jang, Hyo-Ju;Lee, Jang-Hown;Kang, Seon-Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.1
    • /
    • pp.33-40
    • /
    • 2010
  • Individual sewage treatment system is classified into a sewage treatment system which treats all the domestic sewage and a water-purifier tank which treats only effluent flushing from the toilet. The number of registered manufacturers has increased rapidly since 2001. As a result, price competition has increased among the manufacturers and has caused the problems such as the inappropriate production of individual sewage treatment system, the unreasonable permit for building completion and the shortage of the professional technology of the community's public officials in charge. This study collected the problem cases that are related with existing individual sewage treatment system and operation. Efficient improvement plan for the stable supply, installation, maintenance of individual sewage treatment system were suggested.

Pipe Network Analysis by Using Frontal Solution Method (Frontal 기법을 이용한 상수관망의 흐름해석 모형)

  • 박재홍;한건연
    • Water for future
    • /
    • v.29 no.1
    • /
    • pp.141-150
    • /
    • 1996
  • Steady state analysis of pressure and flow in water supply piping systems is a problem of great importance in hydraulic engineering. The basic equations consist of continuity equation and energy equation. The network equations are solved iteratively by using linear solution method. The resulting linear simultaneous equations are solved by frontal method. Frontal method, which is suitable to sparse matrix, gathers only non-zero entries in coefficient matrix. The suggested methodology can analyze faster than the existing routines by using smaller computer memory. The model presented in this study shows accurate and efficient results for various piping systems.

  • PDF

A Study on Hydraulic Pressure Change Characteristics of Water Distribution Networks in Large Cities (대도시 급배수관망의 수압변화 특성에 관한 연구)

  • Oh, Chang-Ju;Kim, Tae-Kyoung;Rhee, Kyoung-Hoon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.3
    • /
    • pp.279-287
    • /
    • 2005
  • In this study, I suggest an effective operation of waterwork facilities in large cities and a scientific method for utilizing water in water distribution systems. To achieve this goal, my simulation were carried out on data from Kwangju City using Pipenet '98, a pipe-network program. From this simulation, I examine the possibilities of application the system in large cities, comparing data measured at 33 hydraulic pressure monitoring places from waterwork enterprises. The result is coincident with that of waterwork enterprises, with about a 12.5% average error rate and $0.32kg/cm^2$ average deviation. The method and program I use here can be helpful in cities where there is a need to extend the waterwork facilities, or where there is a need to suspend the water supply, and/or there is an accident. The simulation shows how to expand waterwork facilities effectively, how to prevent accidents, and how to estimate the hydraulic pressure even in the areas without monitoring places.

A study on earthquake damage prediction system of gas facilities (도시가스시설물의 조기 지진피해평가시스템 구축을 위한 기초연구)

  • Kim, Ick-Hyun;Jung, Hyo-Soon;Jeong, Hyeok-Chang;Lee, Jong-Seok
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2006.03a
    • /
    • pp.366-373
    • /
    • 2006
  • In order to reduce the secondary earthquake disaster resulting from the damage of gas facilities it is indispensable to establish an early response system on the basis of damage prediction. In this study the procedure of damage prediction for gas facilities is proposed and applied to the gas supply model area. Model area is divided into several little blocks. The soil condition and the characteristics of facilities were investigated at each block. Using fragility curves of facilities the damage level was analyzed under various seismicities. It is confirmed that the exposure gas pipe line in several blocks is damaged seriously by the collapse of building structures.

  • PDF

Study on Bandwidth Frequency of Servovalve based on Metering Cylinder (실린더를 이용한 서보 밸브 대역폭 주파수의 측정에 관한 연구)

  • Kim, S.D.;An, Wen-Long;Jeon, S.H.
    • Journal of Drive and Control
    • /
    • v.12 no.3
    • /
    • pp.44-51
    • /
    • 2015
  • In this study, a metering cylinder was constructed, and the velocity obtained from the linear velocity transducer (LVT) of the cylinder piston was used to evaluate the dynamic performance of an electro-hydraulic servovalve. Frequency response experiments involving the spool displacement and piston velocity (LVT signal) were conducted with different input signal amplitudes, hydraulic pipe diameters, and supply pressures. The spool displacement signal accurately reflected the performance of the servovalve. Meanwhile, the -3 dB bandwidth frequency of the LVT signal was similar to the spool displacement signal, except for a small-amplitude input signal, and the $-90^{\circ}$ phase lag bandwidth frequency showed some differences.