• Title/Summary/Keyword: supply delay

Search Result 298, Processing Time 0.02 seconds

A Non-Calibrated 2x Interleaved 10b 120MS/s Pipeline SAR ADC with Minimized Channel Offset Mismatch (보정기법 없이 채널 간 오프셋 부정합을 최소화한 2x Interleaved 10비트 120MS/s 파이프라인 SAR ADC)

  • Cho, Young-Sae;Shim, Hyun-Sun;Lee, Seung-Hoon
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.9
    • /
    • pp.63-73
    • /
    • 2015
  • This work proposes a 2-channel time-interleaved (T-I) 10b 120MS/s pipeline SAR ADC minimizing offset mismatch between channels without any calibration scheme. The proposed ADC employs a 2-channel SAR and T-I topology based on a 2-step pipeline ADC with 4b and 7b in the first and second stage for high conversion rate and low power consumption. Analog circuits such as comparator and residue amplifier are shared between channels to minimize power consumption, chip area, and offset mismatch which limits the ADC linearity in the conventional T-I architecture, without any calibration scheme. The TSPC D flip-flop with a short propagation delay and a small number of transistors is used in the SAR logic instead of the conventional static D flip-flop to achieve high-speed SAR operation as well as low power consumption and chip area. Three separate reference voltage drivers for 4b SAR, 7b SAR circuits and a single residue amplifier prevent undesirable disturbance among the reference voltages due to each different switching operation and minimize gain mismatch between channels. High-frequency clocks with a controllable duty cycle are generated on chip to eliminate the need of external complicated high-frequency clocks for SAR operation. The prototype ADC in a 45nm CMOS technology demonstrates a measured DNL and INL within 0.69LSB and 0.77LSB, with a maximum SNDR and SFDR of 50.9dB and 59.7dB at 120MS/s, respectively. The proposed ADC occupies an active die area of 0.36mm2 and consumes 8.8mW at a 1.1V supply voltage.

Study on the Consequence Effect Analysis & Process Hazard Review at Gas Release from Hydrogen Fluoride Storage Tank (최근 불산 저장탱크에서의 가스 누출시 공정위험 및 결과영향 분석)

  • Ko, JaeSun
    • Journal of the Society of Disaster Information
    • /
    • v.9 no.4
    • /
    • pp.449-461
    • /
    • 2013
  • As the hydrofluoric acid leak in Gumi-si, Gyeongsangbuk-do or hydrochloric acid leak in Ulsan, Gyeongsangnam-do demonstrated, chemical related accidents are mostly caused by large amounts of volatile toxic substances leaking due to the damages of storage tank or pipe lines of transporter. Safety assessment is the most important concern because such toxic material accidents cause human and material damages to the environment and atmosphere of the surrounding area. Therefore, in this study, a hydrofluoric acid leaked from a storage tank was selected as the study example to simulate the leaked substance diffusing into the atmosphere and result analysis was performed through the numerical Analysis and diffusion simulation of ALOHA(Areal Location of Hazardous Atmospheres). the results of a qualitative evaluation of HAZOP (Hazard Operability)was looked at to find that the flange leak, operation delay due to leakage of the valve and the hose, and toxic gas leak were danger factors. Possibility of fire from temperature, pressure and corrosion, nitrogen supply overpressure and toxic leak from internal corrosion of tank or pipe joints were also found to be high. ALOHA resulting effects were a little different depending on the input data of Dense Gas Model, however, the wind direction and speed, rather than atmospheric stability, played bigger role. Higher wind speed affected the diffusion of contaminant. In term of the diffusion concentration, both liquid and gas leaks resulted in almost the same $LC_{50}$ and ALOHA AEGL-3(Acute Exposure Guidline Level) values. Each scenarios showed almost identical results in ALOHA model. Therefore, a buffer distance of toxic gas can be determined by comparing the numerical analysis and the diffusion concentration to the IDLH(Immediately Dangerous to Life and Health). Such study will help perform the risk assessment of toxic leak more efficiently and be utilized in establishing community emergency response system properly.

Seed Viability and Growth Characteristics of Eclipta prostrata (L.) L. (한련초의 종자생존력(種子生存力) 및 생장특성(生長特性))

  • Lee, H.K.;Moody, K.
    • Korean Journal of Weed Science
    • /
    • v.8 no.3
    • /
    • pp.309-316
    • /
    • 1988
  • Several experiments were conducted to investigate the achene viability and growth characteristics of Eclipta prostrata (L.) L. No dormancy and no after-ripening requirement were found for E. prostrata achenes. When achenes were stored at room temperature, germination did not decrease with up to 5 months storage. Large differences in loss of viability of E. prostrata achenes occurred when different dehydration methods were used. Immediate dehydration resulted in high viability, but slow dehydration resulted in severe loss of viability. Achene viability at shallow burial depths (5 and 10 cm deep) was lower under upland soil conditions than under lowland soil conditions. Seedling growth was greatly reduced when flooding to a depth of 10 cm occurred at or before the 4-leaf stage. Flooding after the 4-leaf stage stimulated stem elongation. Branching started from the second week and usually terminated at the tenth week. Leaf size was determined by the branch which are related to the assimilate supply. Flowering of E. prostrata started during the fifth week after emergence, and mature achenes were produced from the sixth week. Ten to 14 days were needed for the achenes to mature. About 14,000 achenes were produced on each plant. Achene production per week increased from the sixth week to the tenth week and thereafter it declined. The average number of achenes per inflorescence decreased with delay in flowering.

  • PDF

A Study on the Application of Bushings Fire Prevent Structure to Prevent Fire Spread of Transformer (변압기의 화재확산 방지를 위한 부싱 방화구조체 적용에 관한 연구)

  • Kim, Do-Hyun;Cho, Nam-Wook;Yoon, Choung-Ho;Park, Pil-Yong;Park, Keun-Sung
    • Fire Science and Engineering
    • /
    • v.31 no.5
    • /
    • pp.53-62
    • /
    • 2017
  • Electric power which is the energy source of economy and industries requires long distance transportation due to regional difference between its production and consumption, and it is supplied through the multi-loop transmission and distribution system. Prior to its actual use, electric power flows through several transformations by voltage transformers in substations depending on the characteristics of each usage, and a transformer has the structure consisting of the main body, winding wire, insulating oil and bushings. A transformer fire that breaks out in substations entails the primary damage that interrupts the power supply to houses and commercial facilities and causes various safety accidents as well as the secondary economic losses. It is considered that causes of such fire include the leak of insulating oil resulting from the destruction of bottom part of bushings, and the chain reaction of fire due to insulating oil that reaches its ignition point within 1 second. The smoke detector and automatic fire extinguishing system are established in order to minimize fire damage, but a difficulty in securing golden time for extinguishing fire due to delay in the operation of detector and release of gas from the extinguishing system has become a problem. Accordingly, this study was carried out according to needs of active mechanism to prevent the spread of fire and block the leak of insulating oil, in accordance with the importance of securing golden time in extinguishing a fire in its early stage. A bushings fireproof structure was developed by applying the high temperature shape retention materials, which are expanded by flame, and mechanical flame cutoff devices. The bushings fireproof structure was installed on the transformer model produced by applying the actual standards of bushings and flange, and the full scale fire test was carried out. It was confirmed that the bushings fireproof structure operated at accurate position and height within 3 seconds from the flame initiation. It is considered that it could block the spread of flame effectively in the event of actual transformer fire.

Heating Effect by Electric Radiator in Greenhouse of Chrysanthemum Cultivation (전기 방열기가 국화재배온실의 난방에 미치는 영향)

  • Suh, Won-Myung;Leem, Jae-Woon;Kim, Young-Ju;Min, Young-Bong;Kim, Hyeon-Tae;Huh, Moo-Ryong;Yoon, Yong-Cheol
    • Journal of agriculture & life science
    • /
    • v.44 no.4
    • /
    • pp.79-85
    • /
    • 2010
  • An analysis in heating effects of an electric radiator located in a 1-2W type chrysanthemum (3 cultivars) cultivation greenhouse installed in Gyeongsang National University drew the following conclusions. During the experiment period, the highest, average, and the lowest outside temperatures were in the ranges of $-3.8{\sim}21.3^{\circ}C$, $-5.2{\sim}16.1^{\circ}C$ and $-12.5{\sim}14.4^{\circ}C$, respectively, and the average relative humidity inside and outside the greenhouses were in the ranges of 43.5~98.6% and 35.2~100%, respectively. From mid-December to early February, the lowest outside temperature was recorded as approximately $-5.0{\sim}-10.0^{\circ}C$, which showed that it tended to be relatively lower than the temperatures recorded at the Jinju Meteorological Observatory. During the night, the leaf temperature measured directly under the radiator tended to be higher by $2{\sim}3^{\circ}C$ than that those at the middle point of the radiator, or higher by a negligible amount. In the case of root zone temperature, it was found that there was almost no difference between temperatures of the part directly under and the middle point, and the time when the highest temperature of root zone and other highest temperatures took place showed that there was about a 2-hour delay phenomenon. The total electricity consumption, energy supply and total heating cost during the experiment period were 2,800 kWh, 2,408,000 kcal and 112,000 won, respectively. When diesel, a kind of fossil fuel, was used as heating oil, the total heating cost was around 224,500 won. It was estimated that the total heating cost could be reduced by around 50% if a radiator was used.

A Study on the Establishment and Operation of a Regulatory Response Framework in connection with the Regulatory Strength of the Licensing Policy for New Medical Devices -Focusing on the Application of FMEA- (의료기기 신제품의 인허가정책 규제강도에 연계한 규제대응 프레임워크 수립 및 운영에 관한 연구 - FMEA 적용을 중심으로 -)

  • Kim, Gyosu;Ru, Gyuha;Kim, Yeonhee
    • Journal of Technology Innovation
    • /
    • v.28 no.4
    • /
    • pp.1-26
    • /
    • 2020
  • Due to the spread of Corona 19 around the world, Infectious Disease Medicine and New Medical Devices such as Diagnostic Agent are being rapidly developed and launched, and for the fast supply and demand of these, each country has eased import regulations or has implemented policies for fast approval(NIDS, 2020). On the other hand, New Developed Medical Devices that are not related to New Infectious Diseases, they are still entering the market through strict licensing and licensing regulations, such as delay and cancellation in the test inspection process, etc. Therefore, This Study specialized in the government-managed laws encountered when New Medical Devices enter the market, derive Factors influencing the Strength of Regulations, analyzes the Strength of Regulations, and proposes a Regulatory Response Framework. The Research Method was conducted by Literature Research, was applied by Failure Mode and Effects Analysis(FMEA) Method, Expert Interview(1st): Idea Collection, Expert Interview(2nd): Validation, and Priority through the Application Process of FMEA Method. A Method of Quantifying the Intensity of Regulation was proposed by multiplying the Impact of the Influencing Factors for each stage of regulation and the Burden Impact for each type of Regulatory Affairs to find the Importance of the Regulatory Factors and multiplying the Severity of the Regulatory Impact. The Implications are that major overseas countries and the Korean government are actively responding with Special Regulatory Policies and Mitigation Policies for fast licensing of New Developed Medical Devices in accordance with Corona 19. It is expected that the direction for improvement of regulations and measures to respond to regulations will be implemented so that a more proactive and preemptive response to the regulatory process of the licensing policy for New Devices can be achieved.

Analysis of Causality of the Increase in the Port Congestion due to the COVID-19 Pandemic and BDI(Baltic Dry Index) (COVID-19 팬데믹으로 인한 체선율 증가와 부정기선 운임지수의 인과성 분석)

  • Lee, Choong-Ho;Park, Keun-Sik
    • Journal of Korea Port Economic Association
    • /
    • v.37 no.4
    • /
    • pp.161-173
    • /
    • 2021
  • The shipping industry plummeted and was depressed due to the global economic crisis caused by the bankruptcy of Lehman Brothers in the US in 2008. In 2020, the shipping market also suffered from a collapse in the unstable global economic situation due to the COVID-19 pandemic, but unexpectedly, it changed to an upward trend from the end of 2020, and in 2021, it exceeded the market of the boom period of 2008. According to the Clarksons report published in May 2021, the decrease in cargo volume due to the COVID-19 pandemic in 2020 has returned to the pre-corona level by the end of 2020, and the tramper bulk carrier capacity of 103~104% of the Panamax has been in the ports due to congestion. Earnings across the bulker segments have risen to ten-year highs in recent months. In this study, as factors affecting BDI, the capacity and congestion ratio of Cape and Panamax ships on the supply side, iron ore and coal seaborne tonnge on the demand side and Granger causality test, IRF(Impulse Response Function) and FEVD(Forecast Error Variance Decomposition) were performed using VAR model to analyze the impact on BDI by congestion caused by strengthen quarantine at the port due to the COVID-19 pandemic and the loading and discharging operation delay due to the infection of the stevedore, etc and to predict the shipping market after the pandemic. As a result of the Granger causality test of variables and BDI using time series data from January 2016 to July 2021, causality was found in the Fleet and Congestion variables, and as a result of the Impulse Response Function, Congestion variable was found to have significant at both upper and lower limit of the confidence interval. As a result of the Forecast Error Variance Decomposition, Congestion variable showed an explanatory power upto 25% for the change in BDI. If the congestion in ports decreases after With Corona, it is expected that there is down-risk in the shipping market. The COVID-19 pandemic occurred not from economic factors but from an ecological factor by the pandemic is different from the past economic crisis. It is necessary to analyze from a different point of view than the past economic crisis. This study has meaningful to analyze the causality and explanatory power of Congestion factor by pandemic.

Considerable Aspects for Technical and Vocational Training in Forestry (임업기술(林業技術) 및 직업훈련(職業訓練)에 고려(考慮)되어야 할 사항(事項))

  • Ma, Sang Kyu
    • Journal of Korean Society of Forest Science
    • /
    • v.51 no.1
    • /
    • pp.56-65
    • /
    • 1981
  • The training of forest ranger level and forest worker level to push the sound forest management and to increase the employment effects in forestry will be done without delay as soon as possible. So several opinions to be considered are here discussed. 1. The ranger level will be at first completely trained with the technics developed and modernized, to process really the sound forest management based on the concept of ecological and economical technic. 2. The organization of vocational training and it's systematical training method will be newly adopted to increase the labour efficiency in forestry. The case of fulltime worker level should be more intensively trained and part-time worker or forest famer level should be trained by the forest ranger and skilled worker with visiting circularly their working place. And the daily employed workers and village people for working should be done by the skilled workers. 3. The training subjects for them at the beginning step will be exploited by the instructors and concerned experts with studying their current conditions. Their practical training is more reasonable to do in the practically managing forest and to carry out under the responsible of leader of this forest. 4. The instructors included rangers of training forest will get specially certain intensive training through the aids of outside experts or through the group instruction with them. 5. The training fields and their reasons to be learned by them are discussed in this paper from the basic knowledge to the skill technics. 6. In oder to systematize and mordernize more rapidly our forest technics that need for training them and also applying directly in the forest management, a total effort of certain type by scientists and technicians scattered individually all over the country is now earnestly demanded to synthesize their knowledge, technic and experience. So to do like this, the establishment of certain organization through which can do their total efforts together will be considered and assisted by the concerned authority. 7. For better lieving of full-time workers, the whole-round year working amount have to be supplied though the work technic-and working plan development. And under the conditions that the timber harvesting work is still not so enough and it has a bad climatic season, the in-side working system and side - job aids will be developed for their sound lieving. 8. The organization of labour management will be soon introduced in the concerning administrativ authority to solve the forest labour problems and to increase the employing effects in forestry in future. 9. The supply programm of improved and trained tools and maschines for forest work is also considered to use by the trained persons. If not to do so, the training results will return to the original condition and will get nothing any more.

  • PDF