• 제목/요약/키워드: superficial velocity

검색결과 129건 처리시간 0.022초

대형교반기의 유지 관리에 관한 연구 (The Study for maintence of heavy duty Agitator)

  • 강문후;양신범;김경표
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2005년도 연구개발 발표회 논문집
    • /
    • pp.425-430
    • /
    • 2005
  • This Study presents to be Agitator maintenance for Water and Wastewater treatment Plant. This procedures offers methods of Design Creteria and performance tests on mixing equipment. These tests may be conducted to determine process performance, mechanical reliability. or suitability of equipment for the intended use. The reasons for conducting performance tests can be varied, but the methods presented should be generally applicable to most situations.

  • PDF

Experimental Study on Two-Phase Flow Parameters of Subcoolet Boiling in Inclined Annulus

  • Lee, Tae-Ho;Kim, Moon-Oh;Park, Goon-Cherl
    • Nuclear Engineering and Technology
    • /
    • 제31권1호
    • /
    • pp.29-48
    • /
    • 1999
  • Local two-phase flow parameters of subcooled flow boiling in inclined annulus were measured to investigate the effect of inclination on the internal flow structure. Two-conductivity probe technique was applied to measure local gas phasic parameters, including void fraction, vapor bubble frequency, chord length, vapor bubble velocity and interfacial area concentration. Local liquid velocity was measured by Pilot tube. Experiments were conducted for three angles of inclination; 0$^{\circ}$(vertical), 30$^{\circ}$, 60$^{\circ}$. The system pressure was maintained at atmospheric pressure. The range of average void fraction was up to 10% and the average liquid superficial velocities were less than 1.3 m/sec. The results of experiments showed that the distributions of two-phase How parameters were influenced by the angle of channel inclination. Especially, the void fraction and chord length distributions were strongly affected by the increase of inclination angle, and flow pattern transition to slug flow was observed depending on the How conditions. The profiles of vapor velocity, liquid velocity and interfacial area concentration were found to be affected by the non-symmetric bubble size distribution in inclined channel. Using the measured distributions of local phasic parameters, an analysis for predicting average void fraction was performed based on the drift flux model and flowing volumetric concentration. And it was demonstrated that the average void fraction can be more appropriately presented in terms of flowing volumetric concentration.

  • PDF

Ejector형 포기장치를 이용한 식품가공폐수를 처리 (Food Processing Wastewater Treatment with Ejector-Type Aerator)

  • 정용현
    • 한국환경과학회지
    • /
    • 제8권2호
    • /
    • pp.221-225
    • /
    • 1999
  • This study was conducted to evaluate the treatment efficiency including reaction kinetics and hydraulic characteristics of food processing wastewater by using an ejector-type aeration system (ETAS) in activated sludge process. The oxygen transfer efficiency in ETAS can be changed in accordance with the depth of reactor. However, the optimum air velocity was found less than 1.82 m/hr at a superficial liquid velocity of 634 m/hr. The ETAS process showed higher organic material removal efficiency than that of the existing activated sludge process under hydraulic detention time 6 to 12 hours. This process, which can maintain MLVSS highly, is able to have high organic material removal efficiency at short HRT and deal with variable organic material loading.

  • PDF

Size Measurements of Droplets Entrained in a Stagnant Bubbling Liquid Column

  • Jeong, Hae-Yong;No, Hee-Cheon;Song, Chul-Hwa;Chung, Moon-Ki
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1996년도 추계학술발표회논문집(1)
    • /
    • pp.254-259
    • /
    • 1996
  • Phase Doppler particle analyze. (PDPA) is a instrument which can be used to obtain simultaneous size and velocity measurements in a multiphase flow. In this study, the size of the water droplets entrained from a bubbling surface of a stagnant liquid column is measured by PDPA with a specially designed transmitter of long focal length and large beam diameter. The test section tube is made of acryle with 18 mm I.D. and 900 mm length. The experimental data are obtained for the air superficial velocity between 0.7 m/s to 3.4 m/s at atmospheric pressure. The experimental results show that there exists large difference in the entrainment mechanism between the churn-turbulent flow and annular flow. Through the present study, the phase Doppler analyzer system is shown to be successfully applied to measure particle sizes larger than $2,000\mu\textrm{m}$ if a transmitter of long focal length is utilized.

  • PDF

순환유동층에서 유동매체량에 따른 수력학적 특성 연구 (Effect of Solid Mass Inventory on Hydrodynamics Characteristics in a Circulating Fluidized Bed)

  • 김은경;신동훈;이종민;김재성;황정호
    • 한국연소학회지
    • /
    • 제7권4호
    • /
    • pp.10-20
    • /
    • 2002
  • This paper discusses effect of solid mass inventory on the hydrodynamic characteristics of circulating fluidized bed(CFB). Operating parameters of solid mass inventory and air flow rates were varied to understand their effects on fludization pattern. Experimental measurements were made in a CFB of which height and diameter are 3m and 0.05m respectively. Black SiC particles ranging from $100{\mu}m\;to\;500{\mu}m$ were employed as the bed material. Superficial gas velocity of riser and J-valve fluidizing velocity were in the ranges of $1.39{\sim}3.24m/s\;and\;0.139{\sim}0.232m/s$, respectively. The axial solid fraction and solid circulation rate of CFB were calculated based on the experimental data and compared with modellings through IEA-CFBC Model and commercial CFD code.

  • PDF

순환유동층에서 Solid Mass Inventory에 따른 수력학적 특성 연구 (Hydrodynamic Characteristics of Circulating Fluidized Bed in Different Mass Inventories)

  • 김은경;신동훈;황정호;이종민;김재성
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2002년도 제25회 KOSCI SYMPOSIUM 논문집
    • /
    • pp.165-172
    • /
    • 2002
  • This paper discusses hydrodynamic characteristics of cold circulating fluidized bed(CFB) in different solid mass inventories. Operating parameters of solid mass inventory, primary air and J-valve fluidizing air were varied to find out the effect on the flow fludization pattern. Experimental measurements were made in a 3m tall CFB that has 0.05m riser diameter and black silica-carbonate of particle sizes from $100{\mu}m$ to $500{\mu}m$ were employed as the bed material. The operating conditions of superficial gas velocity and J-valve fluidizing velocity were in the ranges of 1.39~3.24 m/s and 0.139~0.232 m/s respectively. The axial solid fraction and solid circulation rate of CFB were observed and compared with modelling through IEA-CFBC Model and commercial CFD code.

  • PDF

수직관에서의 이상유동 특성 (Characteristics of Two-Phase Flow in Vertical Pipe)

  • 배병모;심우건
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.879-882
    • /
    • 2004
  • Two-phase flow exists in many industrial components. Characteristics of two-phase flow have been studied by many researchers; however, a further study of the two-phase is required for flow-induced vibration. Characteristics of two-phase flow were measured by force sensor at the end of a vertical pipe. The predominant frequency of fluctuation was obtained for various speeds of flow pattern. A correlation to slug frequency for horizontal flow was obtained by Heywood & Richardson (1979), while Legius et al (1997) for vertical flow. A coefficient based on the correlation is estimated and then compared to the existing ones. The existing empirical formulations for average void fraction were proposed by Wallis (1969), Zuber et al (1967) and Ishii (1970). In the present result, flow parameters, such as flow quality and real velocity, are evaluated with void fraction.

  • PDF

시뮬레이션 데이터와 Spherical Convolution을 통한 준 정적인 수중환경에서의 이동체 속도 및 각도 측정 (Measurement of Moving Object Velocity and Angle in a Quasi-Static Underwater Environment Through Simulation Data and Spherical Convolution)

  • 윤배근;김진현
    • 로봇학회논문지
    • /
    • 제18권1호
    • /
    • pp.53-58
    • /
    • 2023
  • In general, in order to operate an autonomous underwater vehicle (AUV) in an underwater environment, a navigation system such as a Doppler Log (DVL) using a Doppler phenomenon of ultrasonic waves is used for speed and direction estimation. However, most of the ultrasonic sensors in underwater is large for long-distance sensing and the cost is very high. In this study, not only canal neuromast on the fish's lateral lines but also superficial neuromast are studied on the simulation to obtain pressure values for each pressure sensor, and the obtained pressure data is supervised using spherical CNN. To this end, through supervised learning using pressure data obtained from a pressure sensor attached to an underwater vehicle, we can estimate the speed and angle of the underwater vehicle in a quasi-static underwater environment and propose a method for a non-ultrasonic based navigation system.

Effects of Hydrocarbon Additions on Gas-liquid Mass Transfer Coefficients in Biphasic Bioreactors

  • Silva, Teresa Lopes da;Calado, Vitor;Silva, Nadia;Mendes, Rui L.;Alves, Sebastiao S.;Vasconcelos, Jorge M.T.;Reis, Alberto
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • 제11권3호
    • /
    • pp.245-250
    • /
    • 2006
  • The effects of aliphatic hydrocarbons (n-hexadecane and n-dodecane) on the volumetric oxygen mass transfer coefficient $(k_L\;a)$ were studied in flat alveolar airlift reactor and continuous stirred tank reactors (CSTRs). In the flat alveolar airlift reactor, high aeration rates (>2vvm) were required in order to obtain efficient organic-aqueous phase dispersion and reliable $k_La$ measurements. Addition of 1% (v/v) n-hexadecane or n-dodecane increased the $k_La$ 1.55- and 1.33-fold, respectively, compared to the control (superficial velocity: $25.8{\times}10^{-3}m/s$, sparger orifice diameter: 0.5 mm). Analysis of the gas-liquid interfacial area a and the liquid film mass transfer coefficient $k_L$ suggests that the observed $k_La$ increase was a function of the media's liquid film mass transfer. Addition of 1% (v/v) n-hexadecane or n-dodecane to analogous setups using CSTRs led to a $k_La$ increase by a factor of 1.68 and 1.36, respectively (superficial velocity: $2.1{\times}10^{-3}m/s$, stirring rate: 250 rpm). These results propose that low-concentration addition of oxygen-vectors to aerobic microbial cultures has additional benefit relative to incubation in purely aqueous media.

내부 순환 장치의 크기 및 유속 변화에 따른 혼합특성 (Effect of Geometric and Dynamic Parameters on Mixing Characteristic in an Internal-Loop Apparatus)

  • 최윤찬;김동석
    • KSBB Journal
    • /
    • 제11권4호
    • /
    • pp.405-410
    • /
    • 1996
  • 내부 순환 장치를 대규모화함에 따른 혼합특성의 변화를 추적자의 분산실험을 통하여 고찰하였다. 분산특성을 나타내는 무차원수 Bodenstein 수를 5L, 5 50L, 500L 규모의 세 장치에서 공탑기체속도, 액체 순환속도, 포기관의 높이에 대한 직경비의 변화, 빛 반응관의 직경에 대한 포기관의 직경비의 영향에 따 나타내었다. 5L 규모의 장치에서 Bo 수는 공탑 기체속도의 증가에 따라 증가하다 가스 해리 현상의 발생으로 증가폭이 둔해지는 경향을 나타내었으며, 5 50L와 500L 장치에서는 공탑기체속도의 증가에 따라 Eo 수가 감소하였는데, 이는 역혼합의 영향이 크게 나타난 것으로 판단되었다. 또한, 500L 규모 장 치에서 Eo 수의 변화는 50L 장치에서 보다 낮은 공 탑기체속도하에서 변화하는 것으로 보아 대규모화에 따라 흔합이 더욱 빨리 발생함을 알 수 있었다. 차원 해석을 통하여 각 변수틀간의 상관관계를 구하였고, 회귀분석을 통하여 다음과 같은 결과식을 구하였다.

  • PDF