• 제목/요약/키워드: superconducting fault current limiter (SFCL)

검색결과 377건 처리시간 0.033초

배전계통에서 리클로져-퓨즈 협조동작시 초전도한류기 적용에 의한 순간전압강하 분석에 관한 연구 (Analysis of Bus Voltage Sag Caused by Recloser-Fuse Coordination in a Power Distribution System with SFCL)

  • 김명후;김진석;유일경;왕순욱;문종필;임성훈;김재철
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제12권1호
    • /
    • pp.22-27
    • /
    • 2010
  • This paper analyzed bus voltage sag caused by recloser-fuse coordination in a power distribution system with SFCL. Generally, the recloser is installed to upstream of fuse to clear against both permanent and temporary faults appropriately, when the fault happened and to block expansion of the fault area. Furthermore, when the fault occurred, bus voltage sag is caused by increased fault currents. However, in a power distribution system with SFCL, the fault current could be decreased by the effect of the impedance value of the SFCL and place to install one as long as it could improve bus voltage sag. Therefore, to analyze the effect of the improvement of bus voltage sag caused by recloser-fuse coordination in a power distribution system with SFCL, we used PSCAD/EMTDC about a permanent fault at the place behind the fuse.

22.9kV 초전도케이블/한류기의 국내 배전계통 적용을 위한 설계사양 고찰 (Specifications for Korean Power system application of 22.9kV HTS cable and FCL)

  • 이승렬;박종영;윤재영;양병모;이승엽;원영진;이병준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.266_267
    • /
    • 2009
  • 22.9kV HTS(High Temperature Superconducting) cable and SFCL(Superconducting Fault Current Limiter) will be installed to Icheon 154kV substation for real distribution power system operation in 2010. This paper proposes CLR (Current Limiting Resistance) specification of the SFCL and fault current condition fo the HTS cable for applying to Korean power system.

  • PDF

22.9kV 초전도 한류기 실계통 적용을 위한 절연협조 검토 (The Study on Insulation Coordination on 22.9kV SFCL for Applying to Real Grid)

  • 김태훈;강지원;강연욱;박진우;이한상;양병모
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제14권1호
    • /
    • pp.20-24
    • /
    • 2012
  • This paper proposes an insulation coordination and surge arrester design for superconducting power system with SFCL(Superconducting Fault Current Limiter) in Icheon substation. In the aspect of the economic analysis, since the superconducting devices are very expensive, the insulation coordination to prevent the dielectric breakdown caused by the lightning surge should be considered carefully. In this paper, the insulation coordination for real grid including SFCL and the design of the protection devices against lightning surge is verified using PSCAD/EM TDC.

개선된 자속구속형의 2차 측 권선 방향과 1차 권선수와 2차 권선수의 변화에 따른 사고전류제한 특성 (Current Limiting Characteristics of Improved Flux-Lock Type SFCL According to Winding Direction of Coil 2 and Variable Number of Coil 1 and Coil 2)

  • 김용진;두호익;이동혁;한병성
    • 한국전기전자재료학회논문지
    • /
    • 제23권9호
    • /
    • pp.714-717
    • /
    • 2010
  • The improved flux-lock type superconducting fault current limiter (SFCL) is composed of a series transformer and superconducting unit of the yttrium-barium-copper-oxide (YBCO) coated conductor. In this paper, we investigated current limiting characteristics through winding direction of coil 2 and variable number of coil 1 and coil 2 in improved flux-lock type SFCL. The better fault current characteristics and the burden of YBCO coated conductor can be confirmed from the experimental result in the higher turn ratio of coil 1 and coil 2 in the additive conditions. In case of subtractive condition, we can confirm a similar result in the same case of experimental conditions. but the burden of YBCO coated conductor has been increased from an increase in winding numbers of coil 2.

삼상 분리형 자속커플링 전류제한기의 2차 권선의 턴 수 및 결선 방향에 따른 전류제한 특성 (Current Limiting Characteristics of Separated Three-phase Flux-coupling Type SFCL according to Winding Number of Coil 2 and Winding Direction)

  • 김용진;두호익;두승규;김민주;이동혁;한병성
    • 한국전기전자재료학회논문지
    • /
    • 제22권8호
    • /
    • pp.694-697
    • /
    • 2009
  • The separated three-phase flux-coupling type superconducting fault current limiter(SFCL) is composed of a series transformer and superconducting unit of the YBCO coated conductor. The primary and secondary coils in the transformer were wound in series each other through an iron core and the YBCO coated conductor was connected with secondary coil in parallel. In this paper, we investigated the current limiting characteristics through winding number of coil 2 and winding direction in the flux-coupling type SFCL. Through the analysis, it was shown that additive polarity condition and lower winding number of coil 2 have advantaged from the point of view of fault current limiting and burned of YBCO coated conductor.

저항형 한류기 운전조건에서의 과냉각 액체질소 특성 실험 (Experimental Investigation of the Subcooled Liquid Nitrogen for Resistive Superconducting Fault Current Limiter)

  • 조승연;김동락;양형석;정원묵;김도형;김혜림;현옥배
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 추계학술대회 논문집
    • /
    • pp.332-334
    • /
    • 2003
  • A subcooled liquid nitrogen cryostat is required for the cooling of a 6.6 ㎸, 200 A resistive type superconductive fault current limiter (SFCL). To help understand and design an appropriate cryostat for SFCL a prototype cryostat was fabricated and tested. Several states of subcooled liquid nitrogen were obtained by using cryocooler and helium gas. The temperature was uniformly distributed inside the liquid nitrogen vessel within the range of 0.4 K proving the effectiveness of the conduction cylinder.

  • PDF

DC 리액터형 고온초전도한류기의 전력계통 연계를 위한 자기철심리액터의 설계 (Design of the Magnetic Core Reactor for the connection to the Power System of DC Reactor Type High Temperature Superconducting Fault Current Limiter)

  • 임대준;배덕권;김호민;이찬주;윤경용;윤용수;고태국
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2002년도 학술대회 논문집
    • /
    • pp.322-325
    • /
    • 2002
  • In this paper, the power-linking device connecting the high-Tc super-conducting(HTS) coil to the power system in the DC reactor type three-phase high-Tc superconducting fault current limiter (SFCL) has been designed. This design was triggered from the concept that the magnetic energy could be exchanged into the electrical energy each other. Ferromagnetic material is used as the path of magnetic flux. The device mentioned above was named Magnetic Core Reactor(MCR). MCR was designed to minimize the voltage drop caused by copper loss. The current density of the conductor was 1.3 A/mm$^2$ and % voltage drop was 2%.

  • PDF

병렬연결된 두 코일을 가진 자속구속형 초전도 전류제한기의 공극유무에 따른 전류제한 특성 분석 (Analysis on Fault Current Limiting Characteristics Dependent on Air-Gap in a Flux-Lock Type SFCL with parallel connection of two coils)

  • 임성훈;김재철
    • 조명전기설비학회논문지
    • /
    • 제23권2호
    • /
    • pp.77-81
    • /
    • 2009
  • 병렬연결된 두 코일을 가진 자속구속형 초전도 전류제한기의 사고발생시 철심의 포화를 억제하기 위한 방안으로 공극을 도입하였다. 하지만, 공극의 도입으로 인해 자화전류가 증가하게 되어 자속구속형 초전도 전류제한기의 임피던스 감소를 초래하게 된다. 본 논문에서는 공극유무에 따른 병렬연결된 두 코일을 가진 자속구속형 초전도 전류제한기의 전류제한 특성을 등가회로와 실험결과에 대한 비교분석을 통해 공극도입의 장.단점을 확인하였다.

Cooling Characteristics of Sub-cooled Nitrogen Cryogenic System for 6.6kV/200A Inductive Fault Current Limiter

  • Hyoungku Kang;Bae, Duck-Kweon;Ahn, Min-Cheol;Kim, Hyung-Jin;Chang, Ho-Myung;Ko, Tae-Kuk
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제5권3호
    • /
    • pp.57-61
    • /
    • 2003
  • In this investigation, the 6.6kV/200A Inductive Superconducting Fault Current Limiter (SFCL) was designed and fabricated. The type of DC reactor for Inductive SFCL was determined as solenoid type during the period of $1${st}$ year research. The 5 bobbins for DC reactor were fabricated and each bobbin was wound with 4 stacked High-Tc superconducting (HTS) tapes and the 5 bobbins were connected in series. The critical current and inductance of DC reactor were simulated by Finite Element method (FEM) and compared with the measured results. The characteristics of DC reactor were enhanced in sub-cooled nitrogen system rather than in liquid nitrogen system. The procedures to accomplish the sub-cooled nitrogen system and the experimental results were introduced in detail. Moreover, the design of sub-cooled nitrogen cryogenic system for next year research was introduced in brief.

Brief review of the field test and application of a superconducting fault current limiter

  • Hyun, Ok-Bae
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제19권4호
    • /
    • pp.1-11
    • /
    • 2017
  • This article reviews the recent activities of field testing and application of superconducting fault current limiters (SFCL) based on high-temperature superconductors (HTS). The review particularly focuses on the trends in the field tests in terms of the technical aspects and commercial activities of the SFCLs. Stimulated by the discovery of HTS, numerous research and development activities have been conducted worldwide for SFCLs operating from distribution voltages to transmission voltages. Different types of SFCLs have been developed and field-tested. Consequently, more than 20 field tests and applications have been performed on real grids worldwide while supplying electric power to the customers. These field tests have not only provided the track records of the operation experiences including the problems and maintenance during operation, but also proved their current limiting capabilities against real faults, rendering this new technology highly viable. Through these activities, the following trends in the status of field testing and application are observed. Resistive-type SFCLs with HTS-coated conductors were dominantly used in the most recent field tests. This implies that the resistive type is technically more mature than the other types. Bus-bar coupling and transformer feeders were the major application locations. It is of importance that most of the field applications were conducted as R&D projects. A relevant change from the R&D stage to the application stage is shown as recently deployed SFCLs are expected to be under long-term operation and commercial service. Here, we review the installation of these SFCLs by substation. This review also discusses the recent activities for their commercial applications.